For the SMC IR3000-N04

Page 24

Precision Regulator Series IR1000-A/2000-A/3000-A Construction Basic type (Knob): IR20 0-A r r Knob r

IN side passage r

Pressure regulator spring

OUT side passage q Flapper Nozzle diaphragm w

Nozzle e t y

Supply diaphragm u

Exhaust diaphragm

Valve i Outlet (OUT)

Inlet (IN)

o

Working principle

When the knob is rotated, the flapper is pushed through the spring, and a gap is generated between the nozzle and flapper. The supply pressure flows to the inlet passes through the path between the nozzle and flapper and acts on the supply diaphragm as nozzle back pressure. The force generated by the diaphragm pushes down the valve, and the supply pressure flows to the outlet. The discharged air pressure acts on the exhaust diaphragm, and counteracts against the force generated by the supply diaphragm. The air pressure acts on the nozzle diaphragm at the same time, and counteracts against the compression force of the spring to adjust the set pressure. When the set pressure increases too much, the nozzle diaphragm is pushed up, and a gap is generated between the flapper and nozzle diaphragm after the flapper is closed. The balance of the supply diaphragm and exhaust diaphragm is lost when the nozzle back pressure flows into the atmosphere. The exhaust valve is open after the valve is closed, and excess pressure on the outlet is released to the air. Due to this pilot mechanism, fine pressure variations are detected and precise pressure adjustment is possible.

Component Parts No.

Description

1

Bonnet

2

Nozzle diaphragm assembly

3

Seal

4

Seal

5

Diaphragm spacer

6

Supply diaphragm

7

Exhaust diaphragm assembly

8

Valve assembly

9

Body

Material

IR1000-A

IR2000-A

IR3000-A

Aluminum die-casted Aluminum, Weather resistant NBR HNBR NBR Polyacetal Weather resistant NBR, Steel, Aluminum, Weather resistant NBR

Aluminum, Weather resistant NBR, HNBR

Stainless steel, Aluminum, HNBR

Aluminum, HNBR

Aluminum die-casted

10

Page 25

Series IR1000-A/2000-A/3000-A Construction Basic type (Knob): IR10 0-A r r r q r w IN side passage e y t u IN i

OUT side passage

OUT o

Basic type (Knob): IR30 0-A e e r r w IN side passage e t

IN i

Basic type (Knob): IR30

1 2 q OUT side passage u

OUT o

-A e e r r w IN side passage q e

OUT side passage t u IN i 11

OUT o

Page 26

Precision Regulator Series IR1000-A/2000-A/3000-A Dimensions Basic type (Knob): IR10 0-01 -A 0.5

ø1 1.6

42

Bracket

25

Mounting hole for hexagon panel nut

42

Max. 4

25

Bracket (Option)

28

M10 x 1

31 7.5

Mounting hole

4.5

34

Panel

8.4

Pressure gauge (Option)

25

1.6

OUT

EXH

90.5

53.5

BLEED

2 x 1/8 Pressure gauge port

43.5

9.8

ø30

IN

2 x 1/8 Port size

37.6

45.9

4.5

M28 x 1.5

EXH

When connecting to the EXH port, contact your SMC sales representative separately.

With digital pressure switch: IR10 0-01 E -A 42 M10 x 1

31

25

7.5 M28 x 1.5

1.6

37.6 57

EXH

9.8

OUT

IN

53.5

BLEED

45.9

2 x 1/8 Port size

90.5

4.5

Mounting hole

EXH

2 x 1/8 Pressure gauge port

12

Page 27

Series IR1000-A/2000-A/3000-A Dimensions Basic type (Knob): IR20 0-02 -A .5

ø12

2

48

30

48

Max. 4

Bracket (Option)

Pressure gauge (Option)

Panel

36

32

17.4

28

30

9.5

5.5

30

Bracket Mounting hole for hexagon panel nut

M12 x 1 Mounting hole 5.5

2

OUT

EXH

72 14

ø43

IN

BLEED 45.6

63

2 x 1/4 Port size

113.3

M28 x 1.5

2 x 1/8 Pressure gauge port

60.5

EXH

When connecting to the EXH port, contact your SMC sales representative separately.

With digital pressure switch: IR20 0-02 E -A 48 32

30

9.5 M12 x 1

5.5

Mounting hole

45.6 14

OUT

72

BLEED 2 x 1/4 Port size

64.5 EXH

13

2 x 1/8 Pressure gauge port

EXH

113.3

M28 x 1.5

63 IN

2

Page 28

Precision Regulator Series IR1000-A/2000-A/3000-A Dimensions Basic type (Knob): IR30 0-0

-A

2.3

76

.5

ø12

Mounting hole for hexagon panel nut Bracket

Max. 4

48

Bracket (Option)

76

Panel 48

Pressure gauge (Option) 68.5

53 16

48

M12 x 1 2.3

60 46

9

9

M28 x 1.5

10.8

Mounting hole

91.7

ø43

65.3

76.1 48.1 OUT

42

IN

161

BLEED

2 x 1/8 Pressure gauge port

2 x 1/4 to 1/2 Port size EXH

EXH

With digital pressure switch: IR30 0-0

1/2 Port size

E -A

76

72.5

53 16

M12 x 1 Mounting hole 9

M28 x 1.5

2 x 1/8 Pressure gauge port

161

OUT 42

IN

65.3

48.1

76.1

91.7

BLEED

2 x 1/4 to 1/2 Port size

EXH

1/2 EXH Port size

14

Page 29

Series IR1000-A/2000-A/3000-A Dimensions Basic type (Knob): IR30

1 2

-0

-A 2.5

ø1

2.3

76 Bracket (Option)

48

Bracket 76

Max. 4

48

Mounting hole for hexagon panel nut

Pressure gauge (Option)

Panel 60

9 53

68.5

48

16 M12 x 1 Mounting hole

2.3

9

M28 x 1.5

91.7

141 141

65.3 EXH

OUT

22

IN

91.7

48.1

76.1

ø43

BLEED

2 x 1/8 Pressure gauge port

2 x 1/4 to 1/2 Port size

2 x 1/2 Port size

With digital pressure switch: IR30

1 2

-0

E -A

76 53

72.5

48

16 M12 x 1 Mounting hole

2.3

9

M28 x 1.5

2 x 1/8 Pressure gauge port

OUT

EXH 22

IN

65.3

48.1

76.1

BLEED

15

2 x 1/2 Port size

2 x 1/4 to 1/2 Port size

10.8

46

Page 30

Series IR1000-A/2000-A/3000-A

Specific Product Precautions 1

Be sure to read this before handling. Refer to the back cover for Safety Instructions. For F.R.L. Units Precautions, refer to “Handling Precautions for SMC Products” and the Operation Manual on SMC website, http://www.smcworld.com

Piping

Piping

Warning

1. Screw piping together with the recommended proper torque while holding the side with the female threads. Looseness or faulty sealing will occur if tightening torque is insufficient, while thread damage will result if the torque is excessive. Furthermore, if the side with the female threads is not held while tightening, excessive force will be applied directly to piping brackets, etc., causing damage or other problems.

Recommended Proper Torque Connection thread Torque

1/8 5.2 to 6.6 [7 to 9]

Caution

2. Wrapping of sealant tape When screwing piping or fittings into ports, ensure that metal chips from the pipe threads or sealing material do not enter the piping. Also, when the sealant tape is used, leave 1.5 to 2 thread ridges exposed at the end of the threads.

Wrapping direction

Sealant tape

Ex 2 t pos hr e a ea ds ppro x

.

lbf·ft [N·m]

1/4 3/8 1/2 Note) 8.9 to 10.3 16.2 to 17.7 20.7 to 22.1 [28 to 30] [12 to 14] [22 to 24]

Note) Tightening force for connecting to the EXH port of IR30 5.9 to 7.4 lbf·ft (8 to 10 N·m).

1 2

-A is

Operating Environment

Warning 1. Do not use in an atmosphere having corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these. 2. Do not operate in locations where vibration or impact occurs. 3. In locations which receive direct sunlight, provide a protective cover, etc. 4. In locations near heat sources, block off any radiated heat. 5. In locations where there is contact with spatter from water, oil or solder, etc., implement suitable protective measures.

Air Supply 2. Do not allow twisting or bending moment to be applied other than the weight of the equipment. Provide separate support for external piping, as damage may otherwise occur.

3. Piping materials without flexibility such as steel tube piping are prone to be effected by excess moment load and vibration from the piping side. Use flexible tubing in between to avoid such an effect.

Caution 1. Preparation before piping Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe.

Warning 1. Please consult with SMC when using the product in applications other than compressed air. 2. Do not use compressed air which includes chemicals, synthetic oils containing organic solvents, salt or corrosive gases, etc., as this can cause damage or malfunction. 3. If condensate in the drain bowl is not emptied on a regular basis, the bowl will overflow and allow the condensate to enter the outlet side. This will cause a malfunction of pneumatic equipment. When removing drain is difficult, use of a filter with an auto drain is recommended.

Caution 1. Condensate or dust, etc. in the supply pressure line can cause malfunctions. In addition to an air filter (SMC Series AF, etc.), please use a mist separator (SMC Series AM, AFM) depending on the conditions. Refer to “Air Preparation Equipment Model Selection Guide” (Best Pneumatics No. 5) for air quality.

2. When a lubricator is used at the supply side of the product, it can cause malfunctions. Do not use a lubricator at the supply side of the product. If lubrication is required for terminal devices, connect a lubricator on the output side of the regulator.

16

Page 31

Series IR1000-A/2000-A/3000-A

Specific Product Precautions 2

Be sure to read this before handling. Refer to the back cover for Safety Instructions. For F.R.L. Units Precautions, refer to “Handling Precautions for SMC Products” and the Operation Manual on SMC website, http://www.smcworld.com

Maintenance

Operation

Warning

Caution

1. When the product is removed for maintenance, reduce the set pressure to “0” and shut off the supply pressure completely beforehand. 2. When a pressure gauge is to be mounted, remove the plug after reducing the set pressure to “0”. 3. When using the regulator between a solenoid valve and an actuator, check the pressure gauge periodically. Sudden pressure fluctuations may shorten the durability of the pressure gauge. A digital pressure gauge is recommended for such situation or as deemed necessary.

Handling

Caution 1. When the precision regulator with pressure gauge is used, do not apply impact to the product by dropping it, etc. during transportation or installation. This may cause misalignment of the pressure gauge pointer.

Operation

1. Do not use a precision regulator outside the range of its specifications as this can cause failure. (Refer to the specifications.) 2. When mounting is performed, make connections while confirming port indications. 3. When mounting the bracket or tightening the hexagon panel nut on the panel, tighten them to the recommended proper torque. Looseness or faulty sealing will occur if tightening torque is insufficient, while thread damage will result if the torque is excessive.

Recommended Proper Torque lbf·ft (N·m) Set nut (for bracket) IR20 0-A

IR30

-A

IR30

-A

1.5±0.15 (2.0±0.2)

Hexagon panel nut (for knob type only) IR10 0-A

IR20 0-A 2.6±0.39 (3.5±0.5)

4. After pressure adjustment, be sure to tighten the lock nut. When tightening the nut, tighten so that the knob does not move due to friction caused by tightening.

17

If the problem is not improved, contact your SMC sales representative.

9. The capacity of the output side is large, and when used for the purpose of a relief function, the exhaust sound will be loud when being relieved. Therefore, operate with a silencer (SMC Series AN, etc.) mounted on the exhaust port (EXH port). When using the IR1000-A and 2000-A series, contact your SMC sales representative.

Caution

IR10 0-A

5. When pressure is applied to the inlet of a regulator, make sure that the output is connected to the circuit. Air blow occurs from the outlet and it depends on the operating conditions. 6. The set pressure may vary depending on the elapsed time and change in ambient temperature after pressure setting. If the setting value varies, adjust with the knob. 7. If the directional control valve (solenoid valve, mechanical valve, etc.) is mounted and ON-OFF is repeated for a long time, the set pressure may vary. If the setting value varies, adjust with the knob. 8. There may be pulsation or noise depending on the pressure conditions, piping conditions and ambient environment. In this case, it is possible to improve the problem by changing the pressure conditions and piping conditions.

10. When installing a pressure gauge to the product, do not apply pressure more than the maximum display pressure. This will cause a malfunction.

Page 32

Safety Instructions

These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC)∗1), and other safety regulations.

indicates a hazard with a low level of risk which, Caution: ifCaution not avoided, could result in minor or moderate injury. indicates a hazard with a medium level of risk which, Warning: ifWarning not avoided, could result in death or serious injury.

∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems. ISO 4413: Hydraulic fluid power – General rules relating to systems. IEC 60204-1: Safety of machinery – Electrical equipment of machines. (Part 1: General requirements) ISO 10218-1: Manipulating industrial robots – Safety. etc.

indicates a hazard with a high level of risk which, Danger : Danger if not avoided, will result in death or serious injury.

Warning 1. The compatibility of the product is the responsibility of the person who designs the equipment or decides its specifications. Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment.

2. Only personnel with appropriate training should operate machinery and equipment. The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced.

3. Do not service or attempt to remove product and machinery/ equipment until safety is confirmed. 1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2. When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the power from any appropriate source is cut, and read and understand the specific product precautions of all relevant products carefully. 3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.

4. Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions. 1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight. 2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalog. 3. An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation.

Caution 1. The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch.

Limited warranty and Disclaimer/ Compliance Requirements

The product used is subject to the following “Limited warranty and Disclaimer” and “Compliance Requirements”. Read and accept them before using the product.

Limited warranty and Disclaimer 1. The warranty period of the product is 1 year in service or 1.5 years after the product is delivered, whichever is first.∗2) Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch. 2. For any failure or damage reported within the warranty period which is clearly our responsibility, a replacement product or necessary parts will be provided. This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure of the product. 3. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products. ∗2) Vacuum pads are excluded from this 1 year warranty. A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of rubber material are not covered by the limited warranty.

Compliance Requirements 1. The use of SMC products with production equipment for the manufacture of weapons of mass destruction (WMD) or any other weapon is strictly prohibited. 2. The exports of SMC products or technology from one country to another are governed by the relevant security laws and regulations of the countries involved in the transaction. Prior to the shipment of a SMC product to another country, assure that all local rules governing that export are known and followed.

Caution SMC products are not intended for use as instruments for legal metrology.

Measurement instruments that SMC manufactures or sells have not been qualified by type approval tests relevant to the metrology (measurement) laws of each country. Therefore, SMC products cannot be used for business or certification ordained by the metrology (measurement) laws of each country.

Safety Instructions Be sure to read “Handling Precautions for SMC Products” (M-E03-3) before using.

18

Page 33

Global Manufacturing, Distribution and Service Network Worldwide Subsidiaries EUROPE AUSTRIA SMC Pneumatik GmbH (Austria) BELGIUM SMC Pneumatics N.V./S.A. BULGARIA SMC Industrial Automation Bulgaria EOOD CROATIA SMC Industrijska Automatika d.o.o. CZECH SMC Industrial Automation CZ s.r.o. DENMARK SMC Pneumatik A/S ESTONIA SMC Pneumatics Estonia FINLAND SMC Pneumatics Finland OY FRANCE SMC Pneumatique S.A. GERMANY SMC Pneumatik GmbH GREECE SMC Hellas EPE HUNGARY SMC Hungary Ipari Automatizálási Kft. IRELAND SMC Pneumatics (Ireland) Ltd. ITALY SMC Italia S.p.A.

LATVIA SMC Pneumatics Latvia SIA LITHUANIA SMC Pneumatics Lietuva, UAB NETHERLANDS SMC Pneumatics BV NORWAY SMC Pneumatics Norway A/S POLAND SMC Industrial Automation Polska Sp.z.o.o. ROMANIA SMC Romania S.r.l. RUSSIA SMC Pneumatik LLC. SLOVAKIA SMC Priemyselná Automatizáciá, s.r.o. SLOVENIA SMC Industrijska Avtomatika d.o.o. SPAIN / PORTUGAL SMC España, S.A. SWEDEN SMC Pneumatics Sweden AB SWITZERLAND SMC Pneumatik AG UK SMC Pneumatics (U.K.) Ltd.

ASIA

NORTH AMERICA

CHINA SMC (China) Co., Ltd. HONG KONG SMC Pneumatics (Hong kong) Ltd. INDIA SMC Pneumatics (India) Pvt. Ltd. JAPAN SMC Corporation MALAYSIA SMC Pneumatics (S.E.A.) Sdn. Bhd. PHILIPPINES SMC Pneumatics (Philippines), Inc. SINGAPORE SMC Pneumatics (S.E.A.) Pte. Ltd. SOUTH KOREA SMC Pneumatics Korea Co., Ltd. TAIWAN SMC Pneumatics (Taiwan) Co., Ltd. THAILAND SMC Thailand Ltd.

CANADA SMC Pneumatics (Canada) Ltd. MEXICO SMC Corporation (Mexico) S.A. DE C.V. USA SMC Corporation of America

SOUTH AMERICA ARGENTINA SMC Argentina S.A. BOLIVIA SMC Pneumatics Bolivia S.R.L. BRAZIL SMC Pneumaticos do Brazil Ltda. CHILE SMC Pneumatics (Chile) S.A. PERU SMC Corporation Peru S.A.C. VENEZUELA SMC Neumatica Venezuela S.A.

OCEANIA AUSTRALIA SMC Pneumatics (Australia) Pty. Ltd. NEW ZEALAND SMC Pneumatics (N.Z.) Ltd.

U.S. & Canadian Sales Offices WEST

EAST

Austin Dallas Los Angeles Phoenix Portland San Francisco

Atlanta Birmingham Boston Charlotte Nashville New Jersey Rochester Tampa

CENTRAL

Chicago Cincinnati Cleveland Detroit Indianapolis Milwaukee Minneapolis St. Louis

CANADA

Montreal Toronto Vancouver Windsor

Toronto

Montreal

Detroit

Livermore

Indianapolis

Sales Branches Regional Distribution Centers Central warehouse

Austin

© 2015 SMC Corporation of America, All Rights Reserved. All reasonable efforts to ensure the accuracy of the information detailed in this catalog were made at the time of publishing. However, SMC can in no way warrant the information herein contained as specifications are subject to change without notice.

TT-RRD-5M