The text of a spec sheet · part 5 of 5
Precision Regulator Series IR1000/2000/3000: Series IR12/22/3200-A, Regulator, pages 44 to 53
Pages 44 to 53 of 53, from Precision Regulator Series IR1000/2000/3000
The original document is the PDF (9.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the SMC IR3000-N04
Page 44
Regulator Series IR1200-A/2200-A/3200-A Construction Basic type (Knob): IR22 0-A r r Knob r
IN side passage r
Pressure regulator spring
OUT side passage q Flapper Nozzle diaphragm w
Nozzle e t y
Supply diaphragm u
Exhaust diaphragm
Valve i Outlet (OUT)
Inlet (IN)
o
Working principle
When the knob is rotated, the flapper is pushed through the spring, and a gap is generated between the nozzle and flapper. The supply pressure flows to the inlet passes through the path between the nozzle and flapper and acts on the supply diaphragm as nozzle back pressure. The force generated by the diaphragm pushes down the valve, and the supply pressure flows to the outlet. The discharged air pressure acts on the exhaust diaphragm, and counteracts against the force generated by the supply diaphragm. The air pressure acts on the nozzle diaphragm at the same time, and counteracts against the compression force of the spring to adjust the set pressure. When the set pressure increases too much, the nozzle diaphragm is pushed up, and a gap is generated between the flapper and nozzle diaphragm after the flapper is closed. The balance of the supply diaphragm and exhaust diaphragm is lost when the nozzle back pressure flows into the atmosphere. The exhaust valve is open after the valve is closed, and excess pressure on the outlet is released to the air. Due to this pilot mechanism, pressure variations are detected and pressure adjustment is possible.
Component Parts No.
Description
1
Bonnet
2
Nozzle diaphragm assembly
3
Seal
4
Seal
5
Diaphragm spacer
6
Supply diaphragm
7
Exhaust diaphragm assembly
8
Valve assembly
9
Body
Material
IR1200-A
IR2200-A
IR3200-A
Aluminum die-casted Aluminum, Weather resistant NBR HNBR NBR Polyacetal Weather resistant NBR, Steel, Aluminum, Weather resistant NBR
Aluminum, Weather resistant NBR, HNBR
Stainless steel, Aluminum, HNBR
Aluminum, HNBR
Aluminum die-casted
10
Page 45
Series IR1200-A/2200-A/3200-A Construction Basic type (Knob): IR12 0-A r r r r q w IN side passage e y t u IN i
OUT side passage
OUT o
Basic type (Knob): IR32 0-A e e r r w IN side passage e t
IN i
Basic type (Knob): IR32
1 2 q OUT side passage u
OUT o
-A e e r r w IN side passage q e
OUT side passage t u IN i 11
OUT o
Page 46
Regulator Series IR1200-A/2200-A/3200-A Dimensions Basic type (Knob): IR12 0-01 -A 0.5
ø1 1.6
42
Bracket
25
Mounting hole for hexagon panel nut
42
Max. 4
25
Bracket (Option)
28
M10 x 1
31 7.5
Mounting hole
4.5
34
Panel
8.4
Pressure gauge (Option)
25
1.6
OUT
EXH
2 x 1/8 Pressure gauge port
43.5
90.5
9.8
ø30
IN
37.6
45.9
2 x 1/8 Port size
53.5
4.5
M28 x 1.5
EXH
When connecting to the EXH port, contact your SMC sales representative separately.
With digital pressure switch: IR12 0-01 E -A 42 M10 x 1
31
25
7.5 M28 x 1.5
1.6
57 EXH
90.5
9.8
OUT
IN
37.6
45.9
2 x 1/8 Port size
53.5
4.5
Mounting hole
EXH
2 x 1/8 Pressure gauge port
12
Page 47
Series IR1200-A/2200-A/3200-A Dimensions Basic type (Knob): IR22 0-02 -A .5
ø12
2
48
30
48
Max. 4
Bracket (Option)
Pressure gauge (Option)
Panel
36
32
17.4
28
30
9.5
5.5
30
Bracket Mounting hole for hexagon panel nut
M12 x 1 Mounting hole 5.5
2
OUT
EXH
72 14
ø43
IN
45.6
63
2 x 1/4 Port size
113.3
M28 x 1.5
2 x 1/8 Pressure gauge port
60.5
EXH
When connecting to the EXH port, contact your SMC sales representative separately.
With digital pressure switch: IR22 0-02 E -A 48 32
30
9.5 Mounting hole 5.5
M12 x 1
45.6 14
OUT
72
2 x 1/4 Port size
64.5 EXH
13
2 x 1/8 Pressure gauge port
EXH
113.3
M28 x 1.5
63 IN
2
Page 48
Regulator Series IR1200-A/2200-A/3200-A Dimensions Basic type (Knob): IR32 0-0
-A
2.3
76
.5
ø12
Mounting hole for hexagon panel nut Max. 4
48
Bracket (Option)
Bracket 76
Panel
48
Pressure gauge (Option) 68.5
53 16
48
M12 x 1 2.3
Mounting hole M28 x 1.5
48.1
65.3
76.1
91.7
ø43
2 x 1/8 Pressure gauge port
OUT 42
IN
161
9
46
10.8
9
60
2 x 1/4 to 1/2 Port size EXH
EXH
With digital pressure switch: IR32 0-0
1/2 Port size
E -A
76
72.5
53 16
M12 x 1 Mounting hole
2 x 1/8 Pressure gauge port
161
OUT 42
IN
65.3
48.1
76.1
91.7
9
M28 x 1.5
2 x 1/4 to 1/2 Port size
EXH
1/2 EXH Port size
14
Page 49
Series IR1200-A/2200-A/3200-A Dimensions Basic type (Knob): IR32
1 2
-0
-A 2.5
ø1
2.3
76 Bracket (Option)
48
Bracket 76
Max. 4
48
Mounting hole for hexagon panel nut
Pressure gauge (Option)
Panel 60
9 53
68.5
48
16 M12 x 1 Mounting hole
2.3
91.7
141 141
65.3 EXH
OUT
22
IN
91.7
48.1
76.1
2 x 1/8 Pressure gauge port
ø43
9
M28 x 1.5
2 x 1/4 to 1/2 Port size
2 x 1/2 Port size
With digital pressure switch: IR32
1 2
-0
E -A
76 72.5
53
48
16 M12 x 1 Mounting hole
2.3
2 x 1/8 Pressure gauge port
OUT
EXH 22
IN
65.3
48.1
76.1
9
M28 x 1.5
15
2 x 1/2 Port size
2 x 1/4 to 1/2 Port size
10.8
46
Page 50
Series IR1200-A/2200-A/3200-A
Specific Product Precautions 1
Be sure to read this before handling. Refer to the back cover for Safety Instructions. For F.R.L. Units Precautions, refer to “Handling Precautions for SMC Products” and the Operation Manual on SMC website, http://www.smcworld.com
Piping
Piping
Warning
1. Screw piping together with the recommended proper torque while holding the side with the female threads. Looseness or faulty sealing will occur if tightening torque is insufficient, while thread damage will result if the torque is excessive. Furthermore, if the side with the female threads is not held while tightening, excessive force will be applied directly to piping brackets, etc., causing damage or other problems.
Recommended Proper Torque Connection thread Torque
1/8 5.2 to 6.6 [7 to 9]
Caution 2. Wrapping of sealant tape When screwing piping or fittings into ports, ensure that metal chips from the pipe threads or sealing material do not enter the piping. Also, when the sealant tape is used, leave 1.5 to 2 thread ridges exposed at the end of the threads. Wrapping direction lbf·ft [N·m]
Note) Tightening force for connecting to the EXH port of IR32 5.9 to 7.4 lbf·ft (8 to 10 N·m).
1 2
-A is
Sealant tape
Ex 2 t pos hr e a ea ds ppro x
1/4 3/8 1/2 Note) 8.9 to 10.3 16.2 to 17.7 20.7 to 22.1 [28 to 30] [12 to 14] [22 to 24]
.
Operating Environment
Warning
2. Do not allow twisting or bending moment to be applied other than the weight of the equipment. Provide separate support for external piping, as damage may otherwise occur.
1. Do not use in an atmosphere having corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these. 2. Do not operate in locations where vibration or impact occurs. 3. In locations which receive direct sunlight, provide a protective cover, etc. 4. In locations near heat sources, block off any radiated heat. 5. In locations where there is contact with spatter from water, oil or solder, etc., implement suitable protective measures.
Air Supply
Warning 1. Please consult with SMC when using the product in applications other than compressed air. 2. Do not use compressed air which includes chemicals, synthetic oils containing organic solvents, salt or corrosive gases, etc., as this can cause damage or malfunction. 3. If condensate in the drain bowl is not emptied on a regular basis, the bowl will overflow and allow the condensate to enter the outlet side. This will cause a malfunction of pneumatic equipment.
3. Piping materials without flexibility such as steel tube piping are prone to be effected by excess moment load and vibration from the piping side. Use flexible tubing in between to avoid such an effect.
Caution 1. Preparation before piping Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe.
When removing drain is difficult, use of a filter with an auto drain is recommended.
Caution 1. Condensate or dust, etc. in the supply pressure line can cause malfunctions. In addition to an air filter (SMC Series AF, etc.), please use a mist separator (SMC Series AM, AFM) depending on the conditions. Refer to “Air Preparation Equipment Model Selection Guide” (Best Pneumatics No. 5) for air quality.
2. When a lubricator is used at the supply side of the product, it can cause malfunctions. Do not use a lubricator at the supply side of the product. If lubrication is required for terminal devices, connect a lubricator on the output side of the regulator.
16
Page 51
Series IR1200-A/2200-A/3200-A
Specific Product Precautions 2
Be sure to read this before handling. Refer to the back cover for Safety Instructions. For F.R.L. Units Precautions, refer to “Handling Precautions for SMC Products” and the Operation Manual on SMC website, http://www.smcworld.com
Maintenance
Operation
Warning
Caution
1. When the product is removed for maintenance, reduce the set pressure to “0” and shut off the supply pressure completely beforehand. 2. When a pressure gauge is to be mounted, remove the plug after reducing the set pressure to “0”. 3. When using the regulator between a solenoid valve and an actuator, check the pressure gauge periodically. Sudden pressure fluctuations may shorten the durability of the pressure gauge. A digital pressure gauge is recommended for such situation or as deemed necessary.
Handling
Caution 1. When the regulator with pressure gauge is used, do not apply impact to the product by dropping it, etc. during transportation or installation. This may cause misalignment of the pressure gauge pointer.
Operation
Caution 1. Do not use a regulator outside the range of its specifications as this can cause failure. (Refer to the specifications.) 2. When mounting is performed, make connections while confirming port indications. 3. When mounting the bracket or tightening the hexagon panel nut on the panel, tighten them to the recommended proper torque. Looseness or faulty sealing will occur if tightening torque is insufficient, while thread damage will result if the torque is excessive.
Recommended Proper Torque lbf·ft (N·m) Set nut (for bracket) IR12 0-A
IR22 0-A
IR32
-A
IR32
-A
1.5±0.15 (2.0±0.2)
Hexagon panel nut (for knob type only) IR12 0-A
IR22 0-A 2.6±0.37 (3.5±0.5)
17
4. To set the pressure using the knob, turn the knob in the direction that increases pressure and be sure to tighten the lock nut after the pressure is adjusted. When tightening the nut, tighten so that the knob does not move due to friction caused by tightening. 5. If the pressure is set in the direction that decreases pressure, the pressure may drop from the original set pressure. Turning the knob clockwise increases the outlet pressure, and turning it counterclockwise reduces the pressure. 6. When pressure is applied to the inlet of a regulator, make sure that the output is connected to the circuit. Air blow occurs from the outlet and it depends on the operating conditions. 7. The set pressure may vary depending on the elapsed time and change in ambient temperature after pressure setting. If the setting value varies, adjust with the knob. 8. If the directional control valve (solenoid valve, mechanical valve, etc.) is mounted and ON-OFF is repeated for a long time, the set pressure may vary. If the setting value varies, adjust with the knob. 9. There may be pulsation or noise depending on the pressure conditions, piping conditions and ambient environment. In this case, it is possible to improve the problem by changing the pressure conditions and piping conditions. If the problem is not improved, contact your SMC sales representative.
10. The capacity of the output side is large, and when used for the purpose of a relief function, the exhaust sound will be loud when being relieved. Therefore, operate with a silencer (SMC Series AN, etc.) mounted on the exhaust port (EXH port). When using the IR1200-A and 2200-A series, contact your SMC sales representative.
11. When installing a pressure gauge to the product, do not apply pressure more than the maximum display pressure. This will cause a malfunction.
Page 52
Safety Instructions
These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC)∗1), and other safety regulations.
indicates a hazard with a low level of risk which, Caution: ifCaution not avoided, could result in minor or moderate injury. indicates a hazard with a medium level of risk which, Warning: ifWarning not avoided, could result in death or serious injury.
∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems. ISO 4413: Hydraulic fluid power – General rules relating to systems. IEC 60204-1: Safety of machinery – Electrical equipment of machines. (Part 1: General requirements) ISO 10218-1: Manipulating industrial robots – Safety. etc.
indicates a hazard with a high level of risk which, Danger : Danger if not avoided, will result in death or serious injury.
Warning 1. The compatibility of the product is the responsibility of the person who designs the equipment or decides its specifications. Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment.
2. Only personnel with appropriate training should operate machinery and equipment. The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced.
3. Do not service or attempt to remove product and machinery/ equipment until safety is confirmed. 1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2. When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the power from any appropriate source is cut, and read and understand the specific product precautions of all relevant products carefully. 3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.
4. Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions. 1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight. 2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalog. 3. An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation.
Caution 1. The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch.
Limited warranty and Disclaimer/ Compliance Requirements
The product used is subject to the following “Limited warranty and Disclaimer” and “Compliance Requirements”. Read and accept them before using the product.
Limited warranty and Disclaimer 1. The warranty period of the product is 1 year in service or 1.5 years after the product is delivered, whichever is first.∗2) Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch. 2. For any failure or damage reported within the warranty period which is clearly our responsibility, a replacement product or necessary parts will be provided. This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure of the product. 3. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products. ∗2) Vacuum pads are excluded from this 1 year warranty. A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of rubber material are not covered by the limited warranty.
Compliance Requirements 1. The use of SMC products with production equipment for the manufacture of weapons of mass destruction (WMD) or any other weapon is strictly prohibited. 2. The exports of SMC products or technology from one country to another are governed by the relevant security laws and regulations of the countries involved in the transaction. Prior to the shipment of a SMC product to another country, assure that all local rules governing that export are known and followed.
Caution SMC products are not intended for use as instruments for legal metrology.
Measurement instruments that SMC manufactures or sells have not been qualified by type approval tests relevant to the metrology (measurement) laws of each country. Therefore, SMC products cannot be used for business or certification ordained by the metrology (measurement) laws of each country.
Safety Instructions Be sure to read “Handling Precautions for SMC Products” (M-E03-3) before using.
18
Page 53
Global Manufacturing, Distribution and Service Network Worldwide Subsidiaries EUROPE AUSTRIA SMC Pneumatik GmbH (Austria) BELGIUM SMC Pneumatics N.V./S.A. BULGARIA SMC Industrial Automation Bulgaria EOOD CROATIA SMC Industrijska Automatika d.o.o. CZECH SMC Industrial Automation CZ s.r.o. DENMARK SMC Pneumatik A/S ESTONIA SMC Pneumatics Estonia FINLAND SMC Pneumatics Finland OY FRANCE SMC Pneumatique S.A. GERMANY SMC Pneumatik GmbH GREECE SMC Hellas EPE HUNGARY SMC Hungary Ipari Automatizálási Kft. IRELAND SMC Pneumatics (Ireland) Ltd. ITALY SMC Italia S.p.A.
LATVIA SMC Pneumatics Latvia SIA LITHUANIA SMC Pneumatics Lietuva, UAB NETHERLANDS SMC Pneumatics BV NORWAY SMC Pneumatics Norway A/S POLAND SMC Industrial Automation Polska Sp.z.o.o. ROMANIA SMC Romania S.r.l. RUSSIA SMC Pneumatik LLC. SLOVAKIA SMC Priemyselná Automatizáciá, s.r.o. SLOVENIA SMC Industrijska Avtomatika d.o.o. SPAIN / PORTUGAL SMC España, S.A. SWEDEN SMC Pneumatics Sweden AB SWITZERLAND SMC Pneumatik AG UK SMC Pneumatics (U.K.) Ltd.
ASIA
NORTH AMERICA
CHINA SMC (China) Co., Ltd. HONG KONG SMC Pneumatics (Hong kong) Ltd. INDIA SMC Pneumatics (India) Pvt. Ltd. JAPAN SMC Corporation MALAYSIA SMC Pneumatics (S.E.A.) Sdn. Bhd. PHILIPPINES SMC Pneumatics (Philippines), Inc. SINGAPORE SMC Pneumatics (S.E.A.) Pte. Ltd. SOUTH KOREA SMC Pneumatics Korea Co., Ltd. TAIWAN SMC Pneumatics (Taiwan) Co., Ltd. THAILAND SMC Thailand Ltd.
CANADA SMC Pneumatics (Canada) Ltd. MEXICO SMC Corporation (Mexico) S.A. DE C.V. USA SMC Corporation of America
SOUTH AMERICA ARGENTINA SMC Argentina S.A. BOLIVIA SMC Pneumatics Bolivia S.R.L. BRAZIL SMC Pneumaticos do Brazil Ltda. CHILE SMC Pneumatics (Chile) S.A. PERU SMC Corporation Peru S.A.C. VENEZUELA SMC Neumatica Venezuela S.A.
OCEANIA AUSTRALIA SMC Pneumatics (Australia) Pty. Ltd. NEW ZEALAND SMC Pneumatics (N.Z.) Ltd.
U.S. & Canadian Sales Offices WEST
EAST
Austin Dallas Los Angeles Phoenix Portland San Francisco
Atlanta Birmingham Boston Charlotte Nashville New Jersey Rochester Tampa
CENTRAL
Chicago Cincinnati Cleveland Detroit Indianapolis Milwaukee Minneapolis St. Louis
CANADA
Montreal Toronto Vancouver Windsor
Toronto
Montreal
Detroit
Livermore
Indianapolis
Sales Branches Regional Distribution Centers Central warehouse
Austin
© 2015 SMC Corporation of America, All Rights Reserved. All reasonable efforts to ensure the accuracy of the information detailed in this catalog were made at the time of publishing. However, SMC can in no way warrant the information herein contained as specifications are subject to change without notice.
TT-RRD-5M