Spec sheet · SMC
SMC VS3115/3110 3 Port Direct Operated Solenoid Valve Spec Sheet
Spec sheet4 pagesPDF 259 KB
All 4 pages are below, each with its text.
Filed with · 1 model
Also filed with these models on the old site
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
A four-page spec sheet for the Series VS3115/3110 three-port direct operated solenoid valves with metal seal, body ported (VS3115) or base mounted (VS3110), plus the VS3114-00 manifold valve. It gives the specifications, the ordering code, replacement parts, the manual override and dimensions. The site files it under NVS3115-025D, a code the sheet itself does not print.
- What it is
- 3 port direct operated solenoid valve, metal seal, body ported or base mounted (Series VS3115/3110) p. 1
- Fluid
- Air or inert gas p. 1
- Pressure
- Operating 0 to 1.0 MPa; proof 1.5 MPa p. 1
- Standard coil voltages
- 100 or 200 VAC (50/60 Hz), or 24 VDC p. 1
- Optional coil voltages
- 220, 110, 48 or 24 VAC (50/60 Hz); 100, 48 or 12 VDC p. 1
- Electrical entry
- Grommet or DIN terminal p. 1
- Temperature
- Ambient and fluid -20 to 60°C, no freezing p. 1
- Response time
- 10 ms or less (AC), 45 ms or less (DC) p. 1
- Max. frequency
- 1,500 c.p.m. (AC), 180 c.p.m. (DC) p. 1
- DC power
- 5.5 W p. 1
- Port sizes
- Rc 1/8, Rc 1/4 or Rc 3/8; threads Rc, NPT, NPTF or G p. 2
- Lubrication
- Not required; if lubricated, turbine oil Class 1 ISO VG32 p. 1
- Mounting parts
- Bracket AXT338-11 (body ported only); sub-plate assembly VS3110-S-02 or -03 p. 1, 2
What this sheet walks you through
- Building the ordering code for a VS3115/3110 valve p. 2
- Identifying replacement parts and component materials p. 2
- Fitting, using and locking the optional manual override p. 2
- Mounting dimensions of body ported and base mounted valves p. 3
- Ordering a manifold and working out its length and weight p. 4
Good to know
- The valve should be operated at least once every 30 days. p. 1
- Unlock the manual override before energizing the valve electrically. p. 2
- The bracket fits only the body ported style. p. 2
- The sub-plate assembly comes without mounting bolts and gaskets. p. 2
Questions this sheet answers
What coil voltages does the VS3115 come in?
Standard coils are 100 or 200 VAC at 50/60 Hz, or 24 VDC; 220, 110, 48 and 24 VAC and 100, 48 and 12 VDC are options. p. 1
Does the VS3115 valve need lubrication?
No. If it is lubricated, the sheet calls for turbine oil Class 1 ISO VG32. p. 1
What pressure can the VS3115/3110 handle?
The operating pressure range is 0 to 1.0 MPa, and the proof pressure is 1.5 MPa. p. 1
How do I lock the manual override?
Push the override with a screwdriver until the valve shifts, then turn it 90 degrees right or left to lock it. p. 2
How much does a VS3114 manifold weigh?
The sheet gives M = 0.16n + 0.1 kg, where n is the number of stations (up to 10). p. 4
The file
Size and text
Every page · 4
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 4
Open in the PDF
The text of page 1, from the PDF itself
1
3 Port Direct Operated Solenoid Valve Metal Seal, Body Ported/Base Mounted
VS3115/3110 Standard Specifications
Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the system life or operation.
No-lubrication and dry-air operation possible.
Body ported
Air/Inert gas Fluid 0 to 1.0 MPa Operating pressure range 1.5 MPa Proof pressure –20 to 60°C (No freezing) Ambient and fluid temperature 10 ms or less (AC), 45 ms or less (DC) Response time (1) 1,500 c.p.m. (AC), 180 c.p.m. (DC) Max. operating frequency (2) Non-locking Manual override Not required (Use turbine oil Class 1 ISO VG32, if lubricated.) Lubrication Dustproof [Degrees of protection 0] (4) Enclosure 150/50 (5) Shock/Vibration resistance (m/s2) Electrical entry Grommet, DlN terminal Standard 100, 200 VAC, 50/60 Hz; 24 VDC Coil rated voltage 220, 110, 48, and 24 VAC (50/60 Hz) Option 100, 48, and 12 VDC –15 to –10% of rated voltage Allowable voltage fluctuation Class B or equivalent (130°C) (6) Coil insulation type 51 50 Hz Inrush 45 Apparent power (VA) 60 Hz AC (Power consumption (W)) 17 (5.3) 50 Hz Holding 11 (2.9) 60 Hz Power consumption (W) DC 5.5 Bracket (AXT338-11)/For body ported type Indicator light Accessory (Option) Manual override Note 1) Based on JIS B 8375-1981. (at 0.5 MPa, without surge voltage suppressor) Note 2) Minimum operating frequency is once in 30 days. (Based on JIS B 8375.) Note 3) “Note 1)” and “Note 2)” are with controlled clean air. Note 4) Based on JIS C 0920. Note 5) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial direction and at the right angles to the main valve and armature in both energized and de-energized states every once for each condition. (Values at the initial period) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed at both energized and de-energized states in the axial direction and at the right angles to the main valve and armature. (Values at the initial period)
Base mounted
Flow Characteristics/Weight Body type
Valve model
Base mounted
For manifold use Body ported
JIS Symbol
Flow characteristics Port size
Rc C [dm3/(s·bar)] b Cv C [dm3/(s·bar)] b 18 14 14 38
3.3 3.8 4.0 4.00.36 0.19 0.12 0.150.86 0.86 0.93 0.942.5 3.6 3.2 3.6Without sub-plate0.39 0.34 0.31 0.18
Weight (kg) Cv 0.66 0.88 0.76 0.82
AC 0.34 0.34 0.40 0.40 0.32
DC 0.46 0.46 0.52 0.52 0.44
Caution For Safety Instructions and Solenoid Valve Precautions, refer to pages 4-18-2 to 4-18-6.
How to Calculate the Flow Rate For obtaining the flow rate, refer to page 4-1-6.
4-16-1
V100 SY SYJ VK VZ VT VP VG VP S070 VQ VKF VQZ VZ VS VFN
Page2of 4
Open in the PDF
The text of page 2, from the PDF itself
2
Series VS3115/3110 How to Order
VS311 5
01 5 D
L Thread type Accessory (Option) Mounting
Piping 5Body ported0Base mounted4Manifold
Port size 01 02 02 03 00
Electrical entry
Rc 1 8 Rc 1 4 Rc 1 4 Rc 3 8 Without sub-plate
Nil BGrommet DIN terminalG DL P
Without bracket With bracket
Nil N∗ T∗ E∗
With indicator light With manual override
∗ Bracket is available only on body ported style.
Rc NPT NPTF G
∗ Option
∗ DC: DL (With indicator light)
Coil rated voltage 1 2 5 9
Construction
100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC Other
Body ported
Base mounted De-energized
De-energized
Component Parts
Sub-plate Assembly Part No.: VS3110-S- 02 03 ∗ Mounting bolts and gaskets are not attached.
No. Description Material Aluminum die-casted q Body Stainless steel w Spool/Sleeve Aluminum die-casted e Sub-plate
r t BG-VS3010Platinum silverReplacement Parts No.
Part No. for Mounting Bolt and Gasket
Note Platinum silvery u iPart no.
AC Solenoid capsule assembly
DC AXT338-6 AC Piano Spring wire DC AZ832-16 AXT333-14 AXT338-15 NBR Gasket Plug for cap AXT333-16 Resin AXT333-7-11 AC Stopper Resin AXT333-32-8 DC Enter the operating voltage. Description
Material
Accessory (Option) Indicator light When solenoid is energized, indicator light illuminates, thus the electrical state of the solenoid can be seen from the outside. AC
DC
Manual override Remove the rubber plug on the top of the solenoid cap to mount the manual override. Push the override with a screwdriver to the required stroke and the valve will shift. Turn to the right or left at 90 degrees to lock it. Be sure to unlock the override before energizing the valve electrically. Part no. AC DC Manual override PB0111-3 (With lock) (PB0111) PB0111-1 Description
Note) There is polarity of (1) +, (2) –.
4-16-2
Manual override (Non-locking)
PB0101
PB0101-1
( ): With indicator light
Page3of 4
Open in the PDF
The text of page 3, from the PDF itself
3
Series VS3115/3110 Dimensions Body ported
2-ø6 mounting hole 2-ø6 mounting hole
V100 SY SYJ
G 1/2 (Cable ø8 to ø10)
Manual override Manual override
3-Rc 1 8, 1 4[92.5]VZ89.5 (114) [92.5]3-Rc 1 8, 1 4VKVT VPBracket
Bracket 2-M5, Depth 7 For mounting
VG
2-M5, Depth 7 For mounting
VP S070 VQ
( ): DC [ ]: AC, with indicator light
Base mounted
VKF VQZ
VZ VS 2-ø4.5 Mounting hole 87.5 (111.5) [90.5] 2-ø4.5 Mounting hole Manual override
Manual override ≅300 (Lead wire length)
87.5 (111.5) [90.5] G 1/2 (Cable ø8 to ø10)
3-Rc 1 4 , 3 8
3-Rc 1 4 , 3 8
( ): DC [ ]: AC, with indicator light
4-16-3
VFN
Page4of 4
Open in the PDF
The text of page 4, from the PDF itself
4
Series VS3115/3110
Manifold Specifications Specifications Manifold type Max. number of stations
B mount 10 stations
Port location/Port size P A E Base Base Base
Exhaust type Common38Accessory
Port direction P A E Side Side Side 14 38 Side Bottom Side Blanking plate (With gaskets and screw)
Applicable valve modelAXT338-17AHow to order manifoldVVS31 0051 Thread type···055 stations∗ Option···
P A E Side Side Side Side Bottom Side
Nil N∗ T∗ F∗···0 1···
EXH port type Valve stations
1Common EXHRc NPT NPTF G10 10 stations65 (89.5) [68]91 (115.5) [94]Dimensions2-ø7 Mounting holen-Rc 1 44-Rc 3 8
( ): DC [ ]: AC, with indicator light
n 2 3 4 5 L1 87 125 163 201 L2 100 138 176 214 L1 = 38n + 11, L2 = 38n + 24 n: Station Formula for manifold weight M = 0.16n + 0.1 (kg) L
4-16-46 239 2527 277 2908 315 3289 353 36610 391 404