Page 1
see more at SORInc.com
Request Quote
Dual Hi-Lo Pressure Switches Dual Hi-Lo pressure switches are rugged, field-mounted instruments. The pressure sensing assemblies are conventional Static “O” Ring type. The main difference is that two sensing assemblies share a common process pressure port, housing and electrical conduit connection. Two discrete sensing assemblies provide independently adjustable, fine resolution Set Points that can be calibrated to the same actuation point, or split to the full span of the adjustable range without interaction.
Application Information
The Dual Hi-Lo pressure switches in this catalog consolidate control, alarm and safety shutdown applications into one instrument.
V1: Non-Hazardous Locations
For hazardous locations, a hermetically sealed explosion-proof, stainless steel, switching element capsule (DPDT or SPDT) is provided for each sensing assembly. Explosion-proof capsules are UL Listed and CSA Certified. The housing can be opened for field calibration without interrupting electrical service. For non-hazardous locations, a UL Recognized and CSA Certified DPDT or SPDT switching element is provided for each sensing assembly. The NEMA 4, 4X & IP65 housing also includes a standard terminal strip for ease of wiring. The Static “O” Ring type sensing assemblies provide a wide selection of wetted materials for process compatibility and containment. With a locally provided external relay, the Dual Hi-Lo can function as an on/off or lock-in/ lockout adjustable dead band instrument. For wide adjustable dead band without an external relay, see Form 281. V2: Hazardous Locations
Form 217 (05.17) ©SOR Inc.
SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001
1/16
Page 2
Features and Benefits
Dual Hi-Lo Pressure Switches
Robust Construction • High cycle rate tolerance, long life, not critical to vibration. Instrument Quality • High resolution of Set Points, high repeatability, narrow dead band, negligible temperature effect, high overrange and proof pressures, exceptionally long service life. Field Adjustable Set Points • Full range adjustability. No-charge factory calibration. Cost Effective • Simple, fast installation without special tools, long service life, no required periodic service or spare parts. Installation of one Dual Hi-Lo provides two pressure switches in the time normally required for the installation of one pressure switch. Agency Listings/Certifications • Rostechnadzor (RTN) standard (certificate available upon request)
2/16
Features
Safety Certified to IEC 61508 (SIL) • SOR products are certified to IEC 61508 for non-redundant use in SIL1 and SIL2 Safety Instrumented Systems for most models. For more details or values applicable to a specific product, see the Safety Integrity Level Quick Guide (Form 1528). Built-in Quality • Rigid quality standards maintained from raw material to finished product. Delivery • Routine shipments 7 to 10 working days. Emergency shipments via air within one day. Service • Factory service engineers and area factory representatives provide effective and prompt worldwide service. Warranty • 3 years from date of manufacture
Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com
Form 217 (05.17) ©SOR Inc.
Page 3
Dual Hi-Lo Pressure Switches
Principle
V1 Housing for Non-Hazardous Service
3/4” NPT(F) Electrical Connection
V2 Housing for Hazardous Service
Factory Sealed Electrical Leads Terminal Strip
3/4” NPT(F) Electrical Connection
Explosion Proof Hermetically Sealed Switching Element Capsules
Piston Shafts Set Point Adjusting Nuts
Range Springs
Set Point Adjusting Nuts
*Diaphragms *O-Rings *Pressure Port
Pressure applied to the Dual Hi-Lo pressure switch is routed to two separate pressure sensing assemblies, thereby eliminating Set Point interaction associated with mechanical linkage. Each pressure sensing element of the Dual Hi-Lo Static “O” Ring Pressure Switch is a force-balanced, piston-actuated assembly sealed by a flexible diaphragm and an o-ring that is static. The only wetted parts are the single pressure port, the two diaphragms and the two o-rings. (See asterisks * in the illustration above.) A wide selection of wetted materials is available.
Form 217 (05.17) ©SOR Inc.
Media pressure on the areas of the pistons counteracts the forces of the range springs (each adjustable by a separate and independent nut), and moves the respective piston shaft only a few thousandths of an inch to directly actuate the respective electrical snap-action switching element. This design virtually eliminates friction and its resultant wear.
SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001
3/16
Page 4
Dual Hi-Lo Pressure Switches
Principle
Model Number System
66 V1-K2-N4-C1A-PP Piston housing switching range element spring diaphragm O-Ring pressure port accessories
Quick Selection Guide
Basic Dual Hi-Lo pressure switches with standard wetted parts are normally suitable for air, oil, water and non-corrosive process applications in hostile environments. Refer to the Quick Selection Guide section on page 5 for a basic model number. Corrosive service and particular customer requirements may require optional components. Refer to the How to Order section to build a customized model number or the dedicated page to locate optional components, such as: switching elements, diaphragm systems, pressure ports and accessories. Each position in the model number, except Accessories, must have a designator. Design and specifications are subject to change without notice. For latest revision, see www.sorinc.com.
Applications The Dual Hi-Lo pressure switches in this catalog are suitable for a wide variety of process applications. Specific application requirements can normally be met by selecting optional components, such as switching elements and diaphragm systems. Certain applications may require customized specials. Consult your area SOR representative or the factory. Weathertight and hermetically sealed, explosion-proof models are presented in this catalog. High-pressure, fluid-power (hydraulic) applications where high shock pressure and high cycle rates are expected normally require pivot seal type pressure switches. Refer to Form 219.
How To Order
Information and data in this catalog are formatted to provide a convenient guide to assist instrument engineers, plant engineers and end users in selecting pressure switches for their unique applications. Steps 1 through 5 are required. Step 6 is optional. Orders must have complete model numbers, i.e. each component must have a designator. Step 1: Step 2: Step 3: Step 4: Step 5: Step 6:
Select Piston-Spring adjustable range/Set Point from specifications (pages 6 and 7). (Piston/spring combination determines adjustable range.) Select Housing. Weathertight or explosion proof/weathertight (page 8). Select electrical Switching Element for electrical service (page 9). Select Diaphragm and O-Ring for process compatibility and containment (page 10). Select Pressure Port for process compatibility and connection (page 11). Select Accessories required for service (page 11).
If Agency Listed, pressure switches are required, see page 12 for components that must be specified.
4/16
Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com
Form 217 (05.17) ©SOR Inc.
Page 5
Dual Hi-Lo Pressure Switches
Quick Selection Guide
Basic Dual Hi-Lo pressure switches with standard wetted parts are normally suitable for air, oil, water and non-corrosive processes in hostile environments. The Set Point must be within the adjustable range. Refer to the How to Order section on page 4 to locate optional components. Each position in the model number, except Accessories, must have a designator.
Pressure Switches Model Number Non-Hazardous Locations NEMA 4, 4X, IP65
Typical Dead Band
Model Number Hazardous Locations Class I, Groups A, B, C, & D; Class II, Groups E, F, & G; Divisions 1 & 2
Adjustable Range (increasing pressure) psi
K Switch psi
EF Switch psi
44V1- K2 - N4 - B1A
2 to 8
0.2
0.6
44V2 - EF2 - N4 - B1A
44V1- K4 - N4 - B1A
2 to 25
0.3
0.9
44V2 - EF4 - N4 - B1A
44V1- K5 - N4 - B1A
3 to 50
0.4
1.2
44V2 - EF5 - N4 - B1A
44V1- K45 - N4 - B1A
4 to 75
0.5
1.5
44V2 - EF45 - N4 - B1A
66V1- K2 - N4 - B1A
7 to 30
0.5
1.5
66V2 - EF2 - N4 - B1A
66V1- K3 - N4 - B1A
12 to 100
0.9
2.7
66V2 - EF3 - N4 - B1A
66V1- K5 - N4 - B1A
20 to 180
1.4
4.2
66V2 - EF5 - N4 - B1A
66V1- K45 - N4 - B1A
25 to 275
1.9
5.7
66V2 - EF45 - N4 - B1A
55V1- K3 - N4 - B1A
25 to 240
2.2
6.6
55V2 - EF3 - N4 - B1A
55V1- K5 - N4 - B1A
35 to 375
3.1
9.3
55V2 - EF5 - N4 - B1A
55V1- K45 - N4 - B1A
45 to 550
3.9
11.7
55V2 - EF45 - N4 - B1A
99V1- K4 - N4 - B1A
100 to 500
5.3
15.9
99V2 - EF4 - N4 - B1A
99V1- K5 - N4 - B1A
200 to 1000
9.2
27.6
99V2 - EF5 - N4 - B1A
99V1- K45 - N4 - B1A
200 to 1750
15
45
99V2 - EF45 - N4 - B1A
11V1- K45 - N4 - C1A
500 to 4000
98
294
11V2 - EF45 - N4 - C1A
Vacuum Switches Typical Dead Band
Model Number Hazardous Locations Class I, Groups A, B, C, & D; Class II, Groups E, F, & G; Divisions 1 & 2
Model Number Non-Hazardous Locations NEMA 4, 4X, IP65
(Vacuum-0-Pressure)
in. Hg.
K Switch in. Hg.
EF Switch in. Hg.
74V1- K117 - N4 - B1A
15 - 0 - 15
0.4
1.2
74V2 - EF117 - N4 - B1A
74V1- K118 - N4 - B1A
30 - 0
0.6
1.8
74V2 - EF118 - N4 - B1A
Adjustable
Piston Disignator
Overrange (psi)
Proof (psi)
44, 74
750
1000
66, 55
1500
2500
99
2500
3900
11
4600
4600
Standard Construction
1. Housing: V1, V2-Copper-free aluminum. See housing (page 8) and dimensions (pages 14 & 15) for details. 2. Switching element: K-SPDT 15a 250 VAC; EF-SPDT 5a 250 VAC. See switching element (page 9) for optional switching elements. 3. Diaphragm & o-ring: N4-Primary (wetted) diaphragm TCP; o-ring (wetted) Buna-N. See diaphragm and o-ring (page 10) for optional diaphragm and o-ring systems. Form 217 (05.17) ©SOR Inc.
4. Pressure port: B1A-Aluminum 1/4” NPT(F). See pressure port (page 11) for optional pressure ports. 5. Note that the typical dead band column is divided to show different values for the K switching element in the V1 housing and the EF switching element in the V2 housing. 6. Ambient temperature range: -30 to 180oF (-34 to 80oC). Check page 9 for optional electrical switching elements and page 10 for optional diaphragm systems.
SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001
5/16
Page 6
Dual Hi-Lo Pressure Switches
Step 1: Specification Pressure
66V1-K2-N4-C1A-PP This table lists piston/spring combinations for corresponding adjustable ranges, dead bands, overranges and proof pressures. Adjustable range is expressed for increasing pressure; the Set Point must be within the adjustable range. Dead band is expressed as typical. See dead band considerations at the bottom of page 8.
6/16
Piston Spring
Adjustable Range
Typical Dead Band psi bar [mbar] psi bar [mbar]
44-2
2 to 8
[140 to 550]
0.2
[15]
44-4
2 to 25
0.14 to 1.7
0.3
[20]
44-5
3 to 50
0.2 to 3.5
0.4
[30]
44-45
4 to 75
0.3 to 5
0.5
[35]
66-2
7 to 30
0.5 to 2
0.5
[35]
66-3
12 to 100
0.8 to 7
0.9
[60]
66-5
20 to 180
1.4 to 12
1.4
[95]
66-45
25 to 275
1.7 to 19
1.9
0.15
55-3
25 to 240
1.7 to 16
2.2
0.15
55-5
35 to 375
2.4 to 26
3.1
0.2
55-45
45 to 550
3.1 to 38
3.9
0.25
99-4
100 to 500
7 to 35
5.3
0.4
99-5
200 to 1000
14 to 70
9.2
0.5
99-45
200 to 1750
14 to 120
15
1
11-45
500 to 4000
35 to 275
98
7
Overrange Pressure
Proof Pressure psi bar psi bar
750
50
1000
70
1500
100
2500
170
2500
170
3900
270
4600
320
4600
320
Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com
Form 217 (05.17) ©SOR Inc.
Page 7
Dual Hi-Lo Pressure Switches
Step 1: Specification Compound/Vacuum
74V1-K117-N4-C1A-PP This table lists piston-spring combinations for corresponding adjustable ranges, dead bands, overrange and proof pressures. Dual Hi-Lo vacuum switches are compound; they will operate in either vacuum or pressure modes. Adjustable range is expressed from maximum vacuum decreasing to zero gauge and increasing to maximum pressure. The Set Point must be within the adjustable range. Dead band is expressed as typical. See dead band considerations on the bottom of page 8. A vacuum switch is generally better suited than a pressure switch for Set Points very near zero gauge. Adjustable Range
Typical Dead Band in. Hg bar in. Hg
[mbar]
15 - 0 - 15
0.5 - 0 - 0.5
0.4
[14]
1.0 - 0
0.6
[20]
PistonSpring
(Vacuum-0 Pressure)
74 - 117 74 - 118
30 - 0
(Vacuum Mode)
Notes 1. Dead band values are expressed as typical expected at mid-range with the standard K switching element assembly installed. When optional switching elements are specified, corresponding dead band multipliers shown on page 8 must be applied. 2. Dual Hi-Lo pressure switches can be provided with mixed adjustable ranges. (Requires Accessory Option TT.) For example:
Left adjustable range: 7 to 30 psi
Right adjustable range: 25 to 275 psi Consult factory for special model number.
Form 217 (05.17) ©SOR Inc.
Overrange
Proof psi bar psi bar
750
50
1000
70
3. Diaphragm may have an additional effect on dead band. Consult factory. See Notes on page 9. 4. Metric bar (mbar) values are practical equivalents of the reference English values, not necessarily exact mathematical conversions. This data appears on the product nameplate when metric engineering units are specified.
SORInc.com | 913-888-2630 | Registered Quality System to ISO 9001
7/16
Page 8
Dual Hi-Lo Pressure Switches
Step 2: Housing
66V1-K2-N4-C1A-PP Service
Non-Hazardous Locations
Hazardous Locations UL Listed CSA Certified SAA Approved Snap Switch (Note 2)
Description
Designator
Electrical conduit connection 3/4” NPT(F) NEMA 4, 4X IP65 Material: Alloy 356 copper-free aluminum
V1
Housing contains UL Listed, CSA Certified and SAA Approved snap switch for hazardous locations and hostile environments. See details in Note 2, page 8. Electrical conduit connection 3/4” NPT(F). NEMA 4, 4X, & IP65. Material: Alloy 356 copper-free aluminum.
V2
Notes 1. Check switching element group-housing compatibility below before selecting element. See page 9 for switching element details. 2. Consult the factory for availability of SAA Approved units.
Housing Compatibility Switching Element Group Housing Designator V1
Switching Element Group Housing Designator V2
A, AA, B, BB, C, E, EE, G, J, JJ, K, KA, L, S, T, W, Y
AF, AG, EF, EG, JF, JG
Dead Band Considerations 1. Dead band values are expressed as typical expected at mid-range using the standard K switching element. When optional switching elements are specified, corresponding dead band multipliers must be applied. 2. Dead bands are fixed (nonadjustable), except when the T switching element is used. 3. Dead band can be adjustable by selecting the T switching element. (Not available when piston designator is 11 or 99.) 4. Dead band multipliers must be applied to the typical dead band values shown in the specification tables whenever optional switching elements other than K, KA or W are used. 5. Dead band can be widened by selecting an optional switching element with a multiplier greater than 1.0. Example: Model 66V1-G5-N4-C1A-PP
Typical standard dead band 1.4 psi
G-Switching element multiplier = 3.0
Corrected typical dead band 1.4(3) = 4.2 psi
8/16
Registered Quality System to ISO 9001 | 913-888-2630 | SORInc.com
Switching Element Designators
Dead Band Multiplier
K, KA, W
1.0
E, J, Y
1.5
A, B, EF, G
3.0
JF, L
3.5
AF, EE
4.0
C, JJ, S
5.0
EG
5.5
AA, BB, JG
6.0
AG
8.5
T adjustable
2.5 to 6.5