Page 1 of Square D L140 Series L1442M Cable Pull Limit Switch Product Data Sheet

Spec sheet · Square D

Square D L140 Series L1442M Cable Pull Limit Switch Product Data Sheet

Spec sheet2 pagesPDF 105 KB

Both pages are below, each with its text.

What this file really is

The old site listed this file as a spec sheet for the Schneider APL100WS2M1 and Square D APL100WS2M1. The sheet is for the L1442M cable switch; APL100WS2M1 is not named.

Download the PDF105 KB

Filed with · 2 models

Also filed with these models on the old site

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

Schneider Electric product data sheet (October 2018) for the L1442M, a cable pull limit switch of the L140 severe duty mill range. The sheet does not name the APL100WS2M1 that the site files it under. It lists contacts, ratings, actuation, wiring, dimensions and environmental data for the L1442M.

What it is
L1442M cable pull limit switch, L140 range, severe duty mill series, 600VAC 10A p. 1
Contacts
2 poles, 1 NC + 1 NO, DPDT-DB, Form Zb, snap action p. 1
AC ratings
A600: 5 A at 600 V, 6.25 A at 480 V, 12.5 A at 240 V, 20 A at 120 V p. 1
DC ratings
P600: 0.2 A at 600 V, 1 A at 250 V, 5 A at 120 V p. 1
Thermal current
20 A; rated insulation voltage 600 V p. 1
Actuation
Rotary head, spring return without operating lever, CCW from right; tripping angle 17 ° for cable operated stop switch; maximum displacement 80 ° p. 1
Torque
208 ozf.in minimum to trip; 112 ozf.in minimum to reset p. 1
Wiring
Screw-clamp terminals (AWG 22...AWG 12); 1 entry for 1/2" - 14 NPT p. 1
Short-circuit protection
20 A Bussmann class CC KTK-R-20 fuse with non-time delay p. 2
Dimensions and weight
2.25 in wide, 4.95 in high, 3.41 in deep; 1.5 lb(US) p. 2
Body
Cast aluminium, base plate style 2, corrosion resistant gray paint p. 1, 2
Enclosure
The data sheet states NEMA 1, 2, 4, 12 and 13 (Nema type 250) and IP67 (IEC 60529) p. 2
Temperature
-20...120 °F for operation and storage p. 2
Contact material
90/10 AgCdO on copper (stationary); silver on steel (moveable) p. 1

What this sheet walks you through

  • Electrical ratings of the L1442M contacts p. 1
  • Environmental data and protection of the L1442M p. 2

Good to know

  • The sheet says the switch has no positive opening. p. 1
  • The sheet marks the product as not RoHS compliant. p. 2
  • The sheet says it is not to be used to decide whether the product suits a specific application. p. 1

Questions this sheet answers

What is the Square D L1442M?

A cable pull limit switch in the L140 severe duty mill series, rated 600VAC 10A. p. 1

What contacts does the L1442M cable switch have?

One normally closed and one normally open snap action contact (1 NC + 1 NO, DPDT-DB). p. 1

What fuse protects the L1442M?

A 20 A Bussmann class CC KTK-R-20 fuse with non-time delay. p. 2

What conduit entry does the L1442M take?

One 1/2" - 14 NPT entry conforming to ANSI B1.20.1. p. 1

The file

Size and text

Pages2
PDF105 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Square D L140 Series L1442M Cable Pull Limit Switch Product Data Sheet

The text of page 1, from the PDF itself

Product data sheet Characteristics

L1442M

CABLE SWITCH 600VAC 10A T-L

Range of productL140Series nameSevere duty mill

Product or component type

Limit switch

Product specific application

Cable pull switchDevice short nameL140Body typeFixedHead typeRotary head

Sale per indivisible quantity

1

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.

Main

Complementary Base plate style

Style 2Body materialCast aluminiumFixing modeBy the bodyType of operator

Spring return without operating lever

Function available-Switch actuationCCW From rightType of approachVertical approachElectrical connection

Screw-clamp terminals (AWG 22...AWG 12)

Cable entry

1 entry for 1/2" - 14 NPT conforming to ANSI B1.20.1

Number of poles

2

Contacts type and composition

1 NC + 1 NOContacts styleASwitch functionDPDT-DBContact formForm ZbContacts material

90/10 AgCdO on copper backing stationary contact Silver on steel backing moveable contact

Contacts usage-Contact operationSnap actionPositive openingWithout

Minimum torque for tripping

208 ozf.in

Minimum torque for resetting

112 ozf.in

Tripping angle

17 ° - for cable operated stop switch

Maximum displacement angle

80 °Repeat accuracy+/- 0.03 %

Contact code designation

A600 , AC (Ue = 600 V, Ie = 5 A) conforming to NEMA rating designation A600 , AC (Ue = 480 V, Ie = 6.25 A) conforming to NEMA rating designation A600 , AC (Ue = 240 V, Ie = 12.5 A) conforming to NEMA rating designation A600 , AC (Ue = 120 V, Ie = 20 A) conforming to NEMA rating designation P600 , DC (Ue = 600 V, Ie = 0.2 A) conforming to NEMA rating designation P600 , DC (Ue = 250 V, Ie = 1 A) conforming to NEMA rating designation P600 , DC (Ue = 120 V, Ie = 5 A) conforming to NEMA rating designation

[Ithe] conventional enclosed thermal current

20 A

[Ui] rated insulation voltage

600 V (degree of pollution: 3) conforming to UL 508 600 V (degree of pollution: 3) conforming to CSA C22.2 No 14 600 V (degree of pollution: 3) conforming to IEC 60947-1

Oct 18, 2018

1

Page 2 of Square D L140 Series L1442M Cable Pull Limit Switch Product Data Sheet

The text of page 2, from the PDF itself

[Uimp] rated impulse withstand voltage

2.5 kV AC for 1 minute conforming to CE 2.2 kV AC for 1 minute conforming to UL 2.64 kV AC for 1 minute conforming to CSA

Short-circuit protection

20 A Bussmann class CC KTK-R-20 fuse with non-time delay

Width2.25 inHeight4.95 inDepth3.41 inProduct weight1.5 lb(US)

Environment Shock resistance

30 gn for 9 ms conforming to IEC 60068-2-27

Vibration resistance

10 gn (f = 10...55 Hz) conforming to IEC 60068-2-6

NEMA degree of protection

NEMA 1 Nema type 250 NEMA 2 Nema type 250 NEMA 4 Nema type 250 NEMA 12 Nema type 250 NEMA 13 Nema type 250

IP degree of protection

IP67 conforming to IEC 60529

Electrical shock protection class

Class 0 conforming to IEC 61140

Ambient air temperature for operation

-20...120 °F

Ambient air temperature for storage

-20...120 °F

Protective treatment

Corrosion resistant gray paint

Offer Sustainability RoHS (date code: YYWW)

Will not be compliant

REACh

Reference not containing SVHC above the threshold

Product environmental profile

Available

Product end of life instructions

Need no specific recycling operations

Contractual warranty Warranty period

2

18 months