Spec sheet · Square D
Square D L140 Series L1442M Cable Pull Limit Switch Product Data Sheet
Spec sheet2 pagesPDF 105 KB
Both pages are below, each with its text.
What this file really is
The old site listed this file as a spec sheet for the Schneider APL100WS2M1 and Square D APL100WS2M1. The sheet is for the L1442M cable switch; APL100WS2M1 is not named.
Filed with · 2 models
Also filed with these models on the old site
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
Schneider Electric product data sheet (October 2018) for the L1442M, a cable pull limit switch of the L140 severe duty mill range. The sheet does not name the APL100WS2M1 that the site files it under. It lists contacts, ratings, actuation, wiring, dimensions and environmental data for the L1442M.
- What it is
- L1442M cable pull limit switch, L140 range, severe duty mill series, 600VAC 10A p. 1
- Contacts
- 2 poles, 1 NC + 1 NO, DPDT-DB, Form Zb, snap action p. 1
- AC ratings
- A600: 5 A at 600 V, 6.25 A at 480 V, 12.5 A at 240 V, 20 A at 120 V p. 1
- DC ratings
- P600: 0.2 A at 600 V, 1 A at 250 V, 5 A at 120 V p. 1
- Thermal current
- 20 A; rated insulation voltage 600 V p. 1
- Actuation
- Rotary head, spring return without operating lever, CCW from right; tripping angle 17 ° for cable operated stop switch; maximum displacement 80 ° p. 1
- Torque
- 208 ozf.in minimum to trip; 112 ozf.in minimum to reset p. 1
- Wiring
- Screw-clamp terminals (AWG 22...AWG 12); 1 entry for 1/2" - 14 NPT p. 1
- Short-circuit protection
- 20 A Bussmann class CC KTK-R-20 fuse with non-time delay p. 2
- Dimensions and weight
- 2.25 in wide, 4.95 in high, 3.41 in deep; 1.5 lb(US) p. 2
- Body
- Cast aluminium, base plate style 2, corrosion resistant gray paint p. 1, 2
- Enclosure
- The data sheet states NEMA 1, 2, 4, 12 and 13 (Nema type 250) and IP67 (IEC 60529) p. 2
- Temperature
- -20...120 °F for operation and storage p. 2
- Contact material
- 90/10 AgCdO on copper (stationary); silver on steel (moveable) p. 1
What this sheet walks you through
Good to know
- The sheet says the switch has no positive opening. p. 1
- The sheet marks the product as not RoHS compliant. p. 2
- The sheet says it is not to be used to decide whether the product suits a specific application. p. 1
Questions this sheet answers
What is the Square D L1442M?
A cable pull limit switch in the L140 severe duty mill series, rated 600VAC 10A. p. 1
What contacts does the L1442M cable switch have?
One normally closed and one normally open snap action contact (1 NC + 1 NO, DPDT-DB). p. 1
What fuse protects the L1442M?
A 20 A Bussmann class CC KTK-R-20 fuse with non-time delay. p. 2
What conduit entry does the L1442M take?
One 1/2" - 14 NPT entry conforming to ANSI B1.20.1. p. 1
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
Product data sheet Characteristics
L1442M
CABLE SWITCH 600VAC 10A T-L
Range of productL140Series nameSevere duty mill
Product or component type
Limit switch
Product specific application
Cable pull switchDevice short nameL140Body typeFixedHead typeRotary head
Sale per indivisible quantity
1
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Main
Complementary Base plate style
Style 2Body materialCast aluminiumFixing modeBy the bodyType of operator
Spring return without operating lever
Function available-Switch actuationCCW From rightType of approachVertical approachElectrical connection
Screw-clamp terminals (AWG 22...AWG 12)
Cable entry
1 entry for 1/2" - 14 NPT conforming to ANSI B1.20.1
Number of poles
2
Contacts type and composition
1 NC + 1 NOContacts styleASwitch functionDPDT-DBContact formForm ZbContacts material
90/10 AgCdO on copper backing stationary contact Silver on steel backing moveable contact
Contacts usage-Contact operationSnap actionPositive openingWithout
Minimum torque for tripping
208 ozf.in
Minimum torque for resetting
112 ozf.in
Tripping angle
17 ° - for cable operated stop switch
Maximum displacement angle
80 °Repeat accuracy+/- 0.03 %
Contact code designation
A600 , AC (Ue = 600 V, Ie = 5 A) conforming to NEMA rating designation A600 , AC (Ue = 480 V, Ie = 6.25 A) conforming to NEMA rating designation A600 , AC (Ue = 240 V, Ie = 12.5 A) conforming to NEMA rating designation A600 , AC (Ue = 120 V, Ie = 20 A) conforming to NEMA rating designation P600 , DC (Ue = 600 V, Ie = 0.2 A) conforming to NEMA rating designation P600 , DC (Ue = 250 V, Ie = 1 A) conforming to NEMA rating designation P600 , DC (Ue = 120 V, Ie = 5 A) conforming to NEMA rating designation
[Ithe] conventional enclosed thermal current
20 A
[Ui] rated insulation voltage
600 V (degree of pollution: 3) conforming to UL 508 600 V (degree of pollution: 3) conforming to CSA C22.2 No 14 600 V (degree of pollution: 3) conforming to IEC 60947-1
Oct 18, 2018
1
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
[Uimp] rated impulse withstand voltage
2.5 kV AC for 1 minute conforming to CE 2.2 kV AC for 1 minute conforming to UL 2.64 kV AC for 1 minute conforming to CSA
Short-circuit protection
20 A Bussmann class CC KTK-R-20 fuse with non-time delay
Width2.25 inHeight4.95 inDepth3.41 inProduct weight1.5 lb(US)
Environment Shock resistance
30 gn for 9 ms conforming to IEC 60068-2-27
Vibration resistance
10 gn (f = 10...55 Hz) conforming to IEC 60068-2-6
NEMA degree of protection
NEMA 1 Nema type 250 NEMA 2 Nema type 250 NEMA 4 Nema type 250 NEMA 12 Nema type 250 NEMA 13 Nema type 250
IP degree of protection
IP67 conforming to IEC 60529
Electrical shock protection class
Class 0 conforming to IEC 61140
Ambient air temperature for operation
-20...120 °F
Ambient air temperature for storage
-20...120 °F
Protective treatment
Corrosion resistant gray paint
Offer Sustainability RoHS (date code: YYWW)
Will not be compliant
REACh
Reference not containing SVHC above the threshold
Product environmental profile
Available
Product end of life instructions
Need no specific recycling operations
Contractual warranty Warranty period
2