Page 1 of Schneider XCS-B713, Square D XCS-B713 and Telemecanique XCS-B713 Spec Sheet

Spec sheet · Schneider

Schneider XCS-B713, Square D XCS-B713 and Telemecanique XCS-B713 Spec Sheet

Spec sheet3 pagesPDF 71 KB

All 3 pages are below, each with its text.

Download the PDF71 KB

Covers · 3 models

The models it covers

From the sheet · read page by page

Key facts from this sheet

Each line names its page in the PDF.

Schneider Electric product data sheet (March 2016) for the XCSB713, a Preventa XCSB metal safety switch with a key operated turret head and actuator locking. It lists the contacts, electrical ratings, locking and signalling, dimensions, environment and standards.

What it is
Preventa XCSB metal safety switch with key operated turret head p. 1
Contacts
2 NC + 1 NO, 3 poles, slow-break, break before make; positive opening with NC contact p. 1
Locking
Locking of actuator, unlocking by pushbutton; 1 orange LED on opening of NC contacts, 24/48 V AC/DC signalling circuit p. 1
AC ratings
AC-15, A300: 3 A at 240 V, 6 A at 120 V; thermal current 10 A p. 1
DC ratings
DC-13, Q300: 0.27 A at 250 V, 0.55 A at 125 V p. 1
Wiring
1 entry tapped 1/2" NPT; terminals take 1 x 0.5...2 x 1.5 mm² with or without cable end p. 1
Dimensions
2.05 in (52 mm) wide, 4.49 in (114 mm) high, 1.73 in (44 mm) deep p. 2
Weight
1.05 lb(US) (0.475 kg) p. 2
Material
Zamak body and head p. 2
Temperature
Operating -13...158 °F (-25...70 °C); storage -40...158 °F (-40...70 °C) p. 2
Durability
600000 cycles mechanical; 10 cyc/mn for maximum durability p. 1
Actuation speed
0.03 ft/s (0.01 m/s) to 1.64 ft/s (0.5 m/s) p. 1
Short circuit protection
10 A cartridge fuse type gG (gl) p. 1
Safety level
The data sheet states it can reach SIL 3, PL = e and category 4 with the appropriate monitoring system and correct wiring p. 1

What this sheet walks you through

  • Electrical ratings by utilisation category p. 1
  • Environment, standards and certifications p. 2

Good to know

  • The safety levels apply only with the appropriate monitoring system and correct wiring. p. 1
  • The sheet says it is not to be used to decide whether the product suits a specific application. p. 1

Questions this sheet answers

What contacts does the XCSB713 safety switch have?

Two normally closed and one normally open contact (2 NC + 1 NO), slow-break, break before make. p. 1

How is the XCSB713 actuator released?

The actuator is locked and is unlocked by pushbutton. An orange LED lights on opening of the NC contacts. p. 1

What current can the XCSB713 switch at 120 V AC?

6 A at 120 V, utilisation category AC-15 (A300); 3 A at 240 V. p. 1

What temperature range does the XCSB713 handle?

-13 to 158 °F (-25 to 70 °C) in operation. p. 2

The file

Size and text

Pages3
PDF71 KB
TextText from the PDF itself.

Every page · 3

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Schneider XCS-B713, Square D XCS-B713 and Telemecanique XCS-B713 Spec Sheet

The text of page 1, from the PDF itself

Product data sheet Characteristics

XCSB713

metal safety switch XCSB - 2 NC + 1 NO - slow break - 1 entry tapped 1/2" NPT

Product availability: Stock - Normally stocked in distribution facility

Commercial StatusCommercialisedRange of product

Preventa Safety detection

Product or component type

Safety switchComponent nameXCSBDesignIndustrialMaterialMetalHead type

Key operated turret head

Contacts type and composition

2 NC + 1 NO

Contacts operation

Slow-break, break before make

Cable entry

1 entry tapped 1/2" NPT

Electrical connection

Terminal, 1 x 0.5...2 x 1.5 mm² with or without cable end

Number of poles

3

Locking options description

With locking of actuator, unlocking by pushbutton

Local signalling

1 LED orange (on opening of NC contacts)

Signalling circuit voltage

24/48 V

Complementary Positive opening

With NC contact

Signalling circuit type

AC/DCMechanical durability600000 cycles

Minimum actuation speed

0.03 ft/s (0.01 m/s)

Maximum actuation speed

1.64 ft/s (0.5 m/s)

[Ie] rated operational current

0.27 A at 250 V utilisation category DC-13, Q300 conforming to EN/IEC 60947-5-1 0.55 A at 125 V utilisation category DC-13, Q300 conforming to EN/IEC 60947-5-1 3 A at 240 V utilisation category AC-15, A300 conforming to EN/IEC 60947-5-1 6 A at 120 V utilisation category AC-15, A300 conforming to EN/IEC 60947-5-1

[Ithe] conventional enclosed thermal current

10 A

[Ui] rated insulation voltage

300 V conforming to CSA C22.2 No 14 500 V conforming to EN/IEC 60947-1 300 V conforming to UL 508

[Uimp] rated impulse withstand voltage

6 kV conforming to EN/IEC 60947-5-1

Short circuit protection

10 A cartridge fuse type gG (gl)

Actutr forcible withdrawal rtc

1500 N

Actuator force for extraction

>= 20 N

Operating rate

10 cyc/mn for maximum durability

Safety level

Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508 Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1

Safety reliability data

B10d = 5000000 (value given for a life time of 20 years limited by mechanical or contact wear)

Mar 1, 2016

1

The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.

Main

Page 2 of Schneider XCS-B713, Square D XCS-B713 and Telemecanique XCS-B713 Spec Sheet

The text of page 2, from the PDF itself

Body materialZamakHead materialZamakDepth1.73 in (44 mm)Height4.49 in (114 mm)Width2.05 in (52 mm)Product weight1.05 lb(US) (0.475 kg)Environment Standards

EN 1088/ISO 14119 EN/IEC 60204-1 EN/IEC 60947-5-1 EN/ISO 12100 UL 508 CSA C22.2 No 14

Product certificationsCSA ULProtective treatmentTC

Ambient air temperature for operation

-13...158 °F (-25...70 °C)

Ambient air temperature for storage

-40...158 °F (-40...70 °C)

Vibration resistance

5 gn (f = 10...500 Hz) conforming to IEC 60068-2-6

Shock resistance

10 gn for 11 ms conforming to IEC 60068-2-27

Class of protection against electric shock

Class I conforming to EN/IEC 60536

IP degree of protection

IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1

Ordering and shipping details Category

22411 - LIMIT SWITCHES,IEC,XCKJ

Discount ScheduleTGTIN00785901238096Nbr. of units in pkg.1Package weight(Lbs)0.50Product availability

Stock - Normally stocked in distribution facility

ReturnabilityYCountry of originFR

Offer Sustainability Sustainable offer status RoHS

Green Premium product Compliant - since 1103 -

Schneider Electric declaration of conformity

REACh

Reference not containing SVHC above the threshold

Product environmental profile

Available

Product end of life instructions

Need no specific recycling operations

Contractual warranty Period

2

18 months

Download Product Environmental

Page 3 of Schneider XCS-B713, Square D XCS-B713 and Telemecanique XCS-B713 Spec Sheet

The text of page 3, from the PDF itself

Mouser Electronics Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Schneider Electric: XCSB713