Spec sheet · Schneider
Schneider XCS-B713, Square D XCS-B713 and Telemecanique XCS-B713 Spec Sheet
Spec sheet3 pagesPDF 71 KB
All 3 pages are below, each with its text.
Covers · 3 models
The models it covers
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
Schneider Electric product data sheet (March 2016) for the XCSB713, a Preventa XCSB metal safety switch with a key operated turret head and actuator locking. It lists the contacts, electrical ratings, locking and signalling, dimensions, environment and standards.
- What it is
- Preventa XCSB metal safety switch with key operated turret head p. 1
- Contacts
- 2 NC + 1 NO, 3 poles, slow-break, break before make; positive opening with NC contact p. 1
- Locking
- Locking of actuator, unlocking by pushbutton; 1 orange LED on opening of NC contacts, 24/48 V AC/DC signalling circuit p. 1
- AC ratings
- AC-15, A300: 3 A at 240 V, 6 A at 120 V; thermal current 10 A p. 1
- DC ratings
- DC-13, Q300: 0.27 A at 250 V, 0.55 A at 125 V p. 1
- Wiring
- 1 entry tapped 1/2" NPT; terminals take 1 x 0.5...2 x 1.5 mm² with or without cable end p. 1
- Dimensions
- 2.05 in (52 mm) wide, 4.49 in (114 mm) high, 1.73 in (44 mm) deep p. 2
- Weight
- 1.05 lb(US) (0.475 kg) p. 2
- Material
- Zamak body and head p. 2
- Temperature
- Operating -13...158 °F (-25...70 °C); storage -40...158 °F (-40...70 °C) p. 2
- Durability
- 600000 cycles mechanical; 10 cyc/mn for maximum durability p. 1
- Actuation speed
- 0.03 ft/s (0.01 m/s) to 1.64 ft/s (0.5 m/s) p. 1
- Short circuit protection
- 10 A cartridge fuse type gG (gl) p. 1
- Safety level
- The data sheet states it can reach SIL 3, PL = e and category 4 with the appropriate monitoring system and correct wiring p. 1
What this sheet walks you through
Good to know
- The safety levels apply only with the appropriate monitoring system and correct wiring. p. 1
- The sheet says it is not to be used to decide whether the product suits a specific application. p. 1
Questions this sheet answers
What contacts does the XCSB713 safety switch have?
Two normally closed and one normally open contact (2 NC + 1 NO), slow-break, break before make. p. 1
How is the XCSB713 actuator released?
The actuator is locked and is unlocked by pushbutton. An orange LED lights on opening of the NC contacts. p. 1
What current can the XCSB713 switch at 120 V AC?
6 A at 120 V, utilisation category AC-15 (A300); 3 A at 240 V. p. 1
What temperature range does the XCSB713 handle?
-13 to 158 °F (-25 to 70 °C) in operation. p. 2
The file
Size and text
Every page · 3
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 3
Open in the PDF
The text of page 1, from the PDF itself
Product data sheet Characteristics
XCSB713
metal safety switch XCSB - 2 NC + 1 NO - slow break - 1 entry tapped 1/2" NPT
Product availability: Stock - Normally stocked in distribution facility
Commercial StatusCommercialisedRange of product
Preventa Safety detection
Product or component type
Safety switchComponent nameXCSBDesignIndustrialMaterialMetalHead type
Key operated turret head
Contacts type and composition
2 NC + 1 NO
Contacts operation
Slow-break, break before make
Cable entry
1 entry tapped 1/2" NPT
Electrical connection
Terminal, 1 x 0.5...2 x 1.5 mm² with or without cable end
Number of poles
3
Locking options description
With locking of actuator, unlocking by pushbutton
Local signalling
1 LED orange (on opening of NC contacts)
Signalling circuit voltage
24/48 V
Complementary Positive opening
With NC contact
Signalling circuit type
AC/DCMechanical durability600000 cycles
Minimum actuation speed
0.03 ft/s (0.01 m/s)
Maximum actuation speed
1.64 ft/s (0.5 m/s)
[Ie] rated operational current
0.27 A at 250 V utilisation category DC-13, Q300 conforming to EN/IEC 60947-5-1 0.55 A at 125 V utilisation category DC-13, Q300 conforming to EN/IEC 60947-5-1 3 A at 240 V utilisation category AC-15, A300 conforming to EN/IEC 60947-5-1 6 A at 120 V utilisation category AC-15, A300 conforming to EN/IEC 60947-5-1
[Ithe] conventional enclosed thermal current
10 A
[Ui] rated insulation voltage
300 V conforming to CSA C22.2 No 14 500 V conforming to EN/IEC 60947-1 300 V conforming to UL 508
[Uimp] rated impulse withstand voltage
6 kV conforming to EN/IEC 60947-5-1
Short circuit protection
10 A cartridge fuse type gG (gl)
Actutr forcible withdrawal rtc
1500 N
Actuator force for extraction
>= 20 N
Operating rate
10 cyc/mn for maximum durability
Safety level
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508 Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1 Can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
Safety reliability data
B10d = 5000000 (value given for a life time of 20 years limited by mechanical or contact wear)
Mar 1, 2016
1
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Main
Page2of 3
Open in the PDF
The text of page 2, from the PDF itself
Body materialZamakHead materialZamakDepth1.73 in (44 mm)Height4.49 in (114 mm)Width2.05 in (52 mm)Product weight1.05 lb(US) (0.475 kg)Environment Standards
EN 1088/ISO 14119 EN/IEC 60204-1 EN/IEC 60947-5-1 EN/ISO 12100 UL 508 CSA C22.2 No 14
Product certificationsCSA ULProtective treatmentTC
Ambient air temperature for operation
-13...158 °F (-25...70 °C)
Ambient air temperature for storage
-40...158 °F (-40...70 °C)
Vibration resistance
5 gn (f = 10...500 Hz) conforming to IEC 60068-2-6
Shock resistance
10 gn for 11 ms conforming to IEC 60068-2-27
Class of protection against electric shock
Class I conforming to EN/IEC 60536
IP degree of protection
IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Ordering and shipping details Category
22411 - LIMIT SWITCHES,IEC,XCKJ
Discount ScheduleTGTIN00785901238096Nbr. of units in pkg.1Package weight(Lbs)0.50Product availability
Stock - Normally stocked in distribution facility
ReturnabilityYCountry of originFR
Offer Sustainability Sustainable offer status RoHS
Green Premium product Compliant - since 1103 -
Schneider Electric declaration of conformity
REACh
Reference not containing SVHC above the threshold
Product environmental profile
Available
Product end of life instructions
Need no specific recycling operations
Contractual warranty Period
2
18 months
Download Product Environmental
Page3of 3
Open in the PDF
The text of page 3, from the PDF itself
Mouser Electronics Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information: