TDK-Lambda brochure (JWS June11 v2) for the JWS Series of single output industrial power supplies, models JWS50, JWS75, JWS100, JWS150, JWS300 and JWS600. It gives the shared specifications, a model selector by output voltage, an outline drawing with a dimension table, and the ordering options.
- What it is
- JWS Series single output industrial power supply p. 1
- Input
- Universal input, 85 - 265VAC (47 - 63Hz) or 120 - 330VDC p. 1
- Power factor
- Power factor corrected p. 1
- Cooling
- JWS50 - JWS150 convection; JWS300 and JWS600 internal fan p. 1
- JWS100 versions
- JWS100-3/A, JWS100-5/A, JWS100-6/A, JWS100-9/A, JWS100-12A, JWS100-15/A, JWS100-24/A, JWS100-28/A, JWS100-48/A p. 2
- Isolation test
- Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA), Output to Ground 500VAC (100mA) for 1 min p. 1
- EMI
- Level B EMI; EN55011 / EN55022-B, FCC Class B, VCCI-B p. 1
- Approvals
- The sheet lists UL/CSA60950-1, EN60950-1, VDE0160 and CE Mark p. 1
- Options
- Screw terminals with or without cover (JWS50 - JWS150); Molex terminals (JWS50 & JWS75); Remote On / Off (JWS50 - JWS150) p. 3
What this sheet walks you through
- Choosing a model by output voltage with the model selector p. 2
- Outline drawing and dimension table for each model p. 3
- Ordering options and their suffixes p. 3
Questions this sheet answers
What input voltage does the TDK-Lambda JWS100 accept?
85 - 265VAC at 47 - 63Hz, or 120 - 330VDC. p. 1
Does the JWS100 have a cooling fan?
No. The sheet lists convection cooling for JWS50 - JWS150 and an internal fan only for the JWS300 and JWS600. p. 1
Which output voltage versions of the JWS100 exist?
The model selector lists JWS100-3/A, -5/A, -6/A, -9/A, -12A, -15/A, -24/A, -28/A and -48/A. p. 2
Can the JWS100 be ordered with a cover?
Yes. The options list screw terminals with a cover for JWS50 - JWS150. p. 3
The file
Size and text
Every page · 4
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 4
Open in the PDF
The text of page 1, from the PDF itself
- 5 Year Warranty
- Power Factor Corrected
- Approved to VDE01 60 Machinery Directive
- Universal Input (85 265VAC)
Key Market Segments & Applications Factory Automation:
JWS Series
- Test & Measurement
- Single Output Industrial Power Supplies
Process Control, NC-Machining, Automotive, Packaging Equipment, Materials Handling, Chemical Processing, Robots Burn-in & Test, Automated Test, Instrumentation, Measurement, Detection
JWS Features and Benefits Features
Benefits
- VDE01 60 Approved
- 5 Year Warranty
- Power Factor Corrected
- Level B EMI
- No Additional Approvals Needed
- Lower Cost of Ownership
- Supports Global Use
- Assists Systems Compliance
Specifications ITEMS Input Voltage range Inrush Current (100 / 200VAC) Power Factor Temperature Coefficient Overcurrent Protection Overvoltage Protection Hold Up Time (Typ) Leakage Current (max) Remote Sense Remote On / Off AC Power Fail Parallel Connection Operating Temp. (open frame) Operating Temp. (with cover) Storage Temperature Operating Humidity Storage Humidity Cooling Withstand Voltage Isolation Resistance Vibration (non operating) Shock Safety Agency Approvals Conducted & Radiated EMI Recommended EMI Filter Weight (Typ) Size (WxHxD) Warranty
JWS50MODEL A V ms mA -(*1)g mm -JWS75JWS100JWS150JWS300JWS600
85 - 265VAC (47 - 63Hz) or 120 - 330VDC 25 / 50 20 / 40 Meets EN61000-3-2 <0.02%/oC >105% Yes 20 0.75 No Yes Specify as Option /R Standard Not Available Standard Not Available Standard -10ºC~+60ºC, derate linearly to 60% load from 50ºC~60ºC N/A -10ºC~+50ºC, derate linearly to 60% load from 40ºC~50ºC (JWS50-150) -10ºC~+65ºC, derate linearly to 55% load from 50ºC~65ºC (JWS300-600) -30 to +85ºC 30 - 90% RH 10 - 90% RH 10 - 95% RH JWS50 - JWS150 Convection, JWS300 & JWS600 Internal fan Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA), Output to Ground 500VAC (100mA) for 1 min. >100M at 25ºC & 70%RH, Output to Ground 500VDC 10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour < 196.1 m/s2 UL/CSA60950-1, EN60950-1, VDE0160, CE Mark, Built to meet DENTORI EN55011 / EN55022-B, FCC Class B, VCCI-B MAW1202-22 MAW1203-22 MB1210 MB1216 350 450 650 850 1900 3000 See page 3 5 Years 14 / 28
Notes: 1 non condensing
JWS Series
1
Page2of 4
Open in the PDF
The text of page 2, from the PDF itself
Model Selector2ModelVoltageAdjust RangeMax Curr.Load Reg mVLine Reg mVRipple NoiseEff. (typ)%
JWS300-2 JWS600-2 JWS50-3/A JWS75-3/A JWS100-3/A JWS150-3/A JWS300-3 JWS600-3 JWS50-5/A JWS75-5/A JWS100-5/A JWS150-5/A JWS300-5 JWS600-5 JWS100-6/A JWS300-6 JWS600-6 JWS600-8 JWS50-9/A JWS100-9/A JWS300-9 JWS600-9 JWS50-12/A JWS75-12/A JWS100-12A JWS150-12/A JWS300-12 JWS600-12 JWS50-15/A JWS75-15/A JWS100-15/A JWS150-15/A JWS300-15 JWS600-15 JWS50-24/A JWS75-24/A JWS100-24/A JWS150-24/A JWS300-24 JWS600-24 JWS50-28/A JWS100-28/A JWS150-28/A JWS300-28 JWS600-28 JWS50-48/A JWS75-48/A JWS100-48/A JWS150-48/A JWS300-48 JWS600-48
2.0V 2.0V 3.3V 3.3V 3.3V 3.3V 3.3V 3.3V 5.0V 5.0V 5.0V 5.0V 5.0V 5.0V 6.0V 6.0V 6.0V 8.0V 9.0V 9.0V 9.0V 9.0V 12.0V 12.0V 12.0V 12.0V 12.0V 12.0V 15.0V 15.0V 15.0V 15.0V 15.0V 15.0V 24.0V 24.0V 24.0V 24.0V 24.0V 24.0V 28.0V 28.0V 28.0V 28.0V 28.0V 48.0V 48.0V 48.0V 48.0V 48.0V 48.0V
1.8 - 2.4 1.8 - 2.4 2.85 - 3.63 2.85 - 3.63 2.85 - 3.63 2.85 - 3.63 2.97 - 3.96 2.97 - 3.96 4.5 - 5.5 4.5 - 5.5 4.5 - 5.5 4.5 - 5.5 4.5 - 6.0 4.5 - 6.0 5.4 - 6.6 5.4 - 7.2 5.4 - 7.2 7.2 - 9.6 8.1 - 9.9 8.1 - 9.9 8.1 - 10.8 8.1 - 10.8 10.8 - 13.2 10.8 - 13.2 10.8 - 13.2 10.8 - 13.2 10.8 - 14.4 10.8 - 14.4 13.5 - 16.5 13.5 - 16.5 13.5 - 16.5 13.5 - 16.5 13.5 - 18.0 13.5 - 18.0 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 21.6 - 28.8 21.6 - 28.8 25.2 - 30.8 25.2 - 30.8 25.2 - 30.8 25.2 - 33.6 25.2 - 33.6 43.2 - 52.8 43.2 - 52.8 43.2 - 52.8 43.2 - 52.8 43.2 - 52.8 43.2 - 52.8
60 120 10 15 20 30 60 120 10 15 20 30 60 120 16.7 50 100 68 5.6 11.2 34 68 4.3 6.3 8.5 13 27 53 3.5 5 7 10 22 43 2.2 3.2 4.5 6.5 14 27 2 3.6 5.5 12 23 1.1 1.6 2.1 3.3 6.5 13
30 30 40 40 40 40 30 30 40 40 40 40 30 30 48 36 36 48 76 72 54 54 96 96 96 96 72 72 120 120 120 120 90 90 150 150 150 150 144 144 160 160 160 168 168 240 240 240 240 288 288
20 20 20 20 20 20 20 20 20 20 20 20 20 20 24 24 24 32 36 36 36 36 48 48 48 48 48 48 60 60 60 60 60 60 96 96 96 96 96 96 112 112 112 112 112 192 192 192 192 192 192
120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 150 120 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 200 200 200 200 350 350
60 61 65 67 67 67 68 70 74 74 75 75 74 75 75 74 75 77 74 75 76 77 76 76 76 77 76 80 77 77 77 78 77 81 79 79 79 80 80 82 79 79 80 80 82 79 79 79 80 80 83
JWS Series
Page3of 4
Open in the PDF
The text of page 3, from the PDF itself
HDMOUNTING SURFACESIDE VIEWHFRONT VIEWW(BOTH SIDES)W
Outline Drawing JWS Series
Dimension Table (mm) Height (H)
Width (W)Depth (D)JWS50 JWS75 JWS10037 42 5085 92 92159 175 188JWS150 JWS300 JWS60065 92 9292 120 160198 190 200Options SuffixDescriptionBlank /A* /B /C /R
Screw terminals, no cover (JWS50 - JWS150) Screw terminals, cover (JWS50 - JWS150) Molex terminals, no cover (JWS50 & JWS75) Molex terminals, cover (JWS50 & JWS75) Remote On / Off (JWS50 - JWS150)
- Example Note
- JWS50-5/RA * Standard stock item
For full data and drawings please visit www.emea.tdk-lambda.com/www/jws
JWS Series
3
Page4of 4
Open in the PDF
The text of page 4, from the PDF itself
TDK-LAMBDA EMEA
www.emea-tdk-lambda.com
TDK-Lambda France SAS
TDK-Lambda UK Ltd.
Route de Grivery ZAC des Delaches CS 41077 91978 Courtaboeuf Cedex France Tel: +33 1 60 12 71 65 Fax: +33 1 60 12 71 66 france@fr.tdk-lambda.com www.fr.tdk-lambda.com
Kingsley Avenue Ilfracombe Devon EX34 8ES United Kingdom Tel: +44 (0) 12 71 85 66 66 Fax: +44 (0) 12 71 86 48 94 powersolutions@uk.tdk-lambda.com www.uk.tdk-lambda.com
Italy Sales Office
Nemic Lambda Ltd.
Via dei Lavoratori 128/130 20092 Cinisello Balsamo (MI) Italy Tel: +39 02 61 29 38 63 Fax: +39 02 61 29 09 00 info.italia@it.tdk-lambda.com www.it.tdk-lambda.com
Kibbutz Givat Hashlosha 48800 Israel Tel: +9 723 902 4333 Fax: +9 723 902 4777 info@nemic.co.il www.nemic.co.il
TDK-Lambda Germany GmbH
Russia
Karl-Bold-Strasse 40 77855 Achern Germany Tel: +49 7841 666 0 Fax: +49 7841 5000 info.germany@de.tdk-lambda.com www.de.tdk-lambda.com
Technical Support: St Petersburg Tel: +7 (812) 6580463 Sales: Moscow Tel: +7 (499) 7557732 info@tdk-lambda.ru www.tdk-lambda.ru
Austria Sales Office Aredstrasse 22 2544 Leobersdorf Austria Tel: +43 2256 655 84 Fax: +43 2256 645 12 info.germany@de.tdk-lambda.com www.de.tdk-lambda.com
LOCAL DISTRIBUTIONJWS June11 v24JWS Series