Spec sheet · Lambda
Lambda JWS50-24/A and TDK JWS50-24/A Spec Sheet
Spec sheet3 pagesPDF 202 KB
All 3 pages are below, each with its text.
Covers · 2 models
The models it covers
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
TDK-Lambda US data sheet (Revision A7, February 2012) for the JWS Series of single output industrial power supplies, models JWS50, JWS75, JWS100, JWS150, JWS300 and JWS600, including the JWS50-24/A. It gives the shared specifications, a model table by output voltage, a dimension table and the ordering options, and marks the series as not recommended for new designs.
- What it is
- JWS Series single output industrial power supply p. 1
- Input
- Universal input, 85 - 265VAC (47 - 63Hz) or 120 - 330VDC p. 1
- Power factor
- Power factor corrected p. 1
- Cooling
- JWS50 - JWS150 convection; JWS300 and JWS600 internal fan p. 1
- Isolation test
- Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA), Output to Ground 500VAC (100mA) for 1 min p. 1
- EMI
- Level B EMI; EN55011 / EN55022-B, FCC Class B, VCCI-B p. 1
- Approvals
- The sheet lists UL60950-1, CSA C22.2 No. 60950-1, EN60950-1, VDE0160 and CE Mark p. 1
- JWS50 versions
- JWS50-3/A, JWS50-5/A, JWS50-9/A, JWS50-12/A, JWS50-15/A, JWS50-24/A, JWS50-28/A, JWS50-48/A p. 2
- Options
- Screw terminals with or without cover (JWS50 - JWS150); Molex terminals with or without cover (JWS50 & JWS75); Remote On / Off (JWS50 - JWS150) p. 2
What this sheet walks you through
- Choosing a model by output voltage p. 2
- Dimensions table and outline drawing p. 2
- Ordering options and their suffixes p. 2
Good to know
- The sheet marks the JWS series as not recommended for new designs and points to the HWS series. p. 1, 2
Questions this sheet answers
What input voltage does the JWS50-24/A accept?
The JWS series takes 85 - 265VAC at 47 - 63Hz, or 120 - 330VDC. p. 1
Does the JWS50 need a fan?
No. The sheet lists convection cooling for JWS50 - JWS150; only the JWS300 and JWS600 have an internal fan. p. 1
Is the TDK-Lambda JWS series still recommended?
The sheet says it is not recommended for new designs and refers to the HWS series. p. 1
What other output voltages does the JWS50 come in?
The model table lists JWS50-3/A, -5/A, -9/A, -12/A, -15/A, -24/A, -28/A and -48/A. p. 2
The file
Size and text
Every page · 3
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 3
Open in the PDF
The text of page 1, from the PDF itself
JWS Series Single Output Industrial Power Supplies Features u 5 Year Warranty u Power factor Corrected u Approved to VDE0160 Machinery Directive u Universal Input (85 - 265VAC) u Level B EMI
Key Market Segments & Applications u Factory Automation Process Control, NC-Machining, Automotive, Packaging Equipment, Materials Handling, Chemical Processing, Robots u Test & Measurement Burn-in & Test, Automated Test, Instrumentation, Measurement, Detection
Not recommended for new designs - see HWS series Specifications Model Input Voltage range Inrush Current (100 / 200VAC) Power Factor Temperature Coefficient Overcurrent Protection Overvoltage Protection Hold Up Time (Typ) Leakage Current (max) Remote Sense Remote On / Off AC Power Fail Parallel Connection Operating Temp. (open frame) Operating Temp. (with cover) Storage Temperature Operating Humidity Storage Humidity Cooling Withstand Voltage
(1) (1)
Isolation Resistance Vibration (non operating) Shock Safety Agency Approvals Conducted & Radiated EMI Recommended EMI Filter Weight (Typ) Size (WxHxD) Warranty
JWS50
A V ms mA g mm -
JWS75 JWS100 JWS150 JWS300 JWS600 85 - 265VAC (47 - 63Hz) or 120 - 330VDC 14 / 28 25 / 50 20 / 40 Meets EN61000-3-2 <0.02%/°C >105% Yes 20 0.75 No Yes Specify as Option /R Standard Not Available Standard Not Available Avail. JWS300 & 600 only -10ºC~+60ºC, derate linearly to 60% load from 50ºC~60ºC -10ºC~+50ºC, derate linearly to 60% load from 40ºC~50ºC (JWS50-150) -10ºC~+65ºC, derate linearly to 55% load from 50ºC~65ºC (JWS300-600) -30 to +85ºC 30 - 90% RH 10 - 90% RH 10 - 95% RH JWS50 - JWS150 Convection, JWS300 & JWS600 Internal fan Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA), Output to Ground 500VAC (100mA) for 1 min. >100M at 25ºC & 70%RH, Output to Ground 500VDC 10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour < 196.1 m/s2 UL60950-1, CSA C22.2 No. 60950-1, EN60950-1, VDE0160, CE Mark, Built to meet DENTORI EN55011 / EN55022-B, FCC Class B, VCCI-B MAW1202-22 MAW1203-22 MB1210 MB1216 350 450 650 850 1900 3000 See side 2 Five Years
(1) Non condensing
1-800-526-2324 • www.us.tdk-lambda.com/lp/
11
Disclaimer: us.tdk-lambda.com/lp/legal.htm
Page2of 3
Open in the PDF
The text of page 2, from the PDF itself
JWS Series Model Derating* Model
Voltage
Adjust Range
JWS300-2 JWS600-2 JWS50-3/A JWS75-3/A JWS100-3/A JWS150-3/A JWS300-3 JWS600-3 JWS50-5/A JWS75-5/A JWS100-5/A JWS150-5/A JWS300-5 JWS600-5 JWS100-6/A JWS300-6 JWS600-6 JWS600-8 JWS50-9/A JWS100-9/A JWS300-9 JWS600-9 JWS50-12/A JWS75-12/A JWS100-12A JWS150-12/A JWS300-12 JWS600-12 JWS50-15/A JWS75-15/A JWS100-15/A JWS150-15/A JWS300-15 JWS600-15 JWS50-24/A JWS75-24/A JWS100-24/A JWS150-24/A JWS300-24 JWS600-24 JWS50-28/A JWS100-28/A JWS150-28/A JWS300-28 JWS600-28 JWS50-48/A JWS75-48/A JWS100-48/A JWS150-48/A JWS300-48 JWS600-48
2.0V 2.0V 3.3V 3.3V 3.3V 3.3V 3.3V 3.3V 5.0V 5.0V 5.0V 5.0V 5.0V 5.0V 6.0V 6.0V 6.0V 8.0V 9.0V 9.0V 9.0V 9.0V 12.0V 12.0V 12.0V 12.0V 12.0V 12.0V 15.0V 15.0V 15.0V 15.0V 15.0V 15.0V 24.0V 24.0V 24.0V 24.0V 24.0V 24.0V 28.0V 28.0V 28.0V 28.0V 28.0V 48.0V 48.0V 48.0V 48.0V 48.0V 48.0V
1.8 - 2.4 1.8 - 2.4 2.85 - 3.63 2.85 - 3.63 2.85 - 3.63 2.85 - 3.63 2.97 - 3.96 2.97 - 3.96 4.5 - 5.5 4.5 - 5.5 4.5 - 5.5 4.5 - 5.5 4.5 - 6.0 4.5 - 6.0 5.4 - 6.6 5.4 - 7.2 5.4 - 7.2 7.2 - 9.6 8.1 - 9.9 8.1 - 9.9 8.1 - 10.8 8.1 - 10.8 10.8 - 13.2 10.8 - 13.2 10.8 - 13.2 10.8 - 13.2 10.8 - 14.4 10.8 - 14.4 13.5 - 16.5 13.5 - 16.5 13.5 - 16.5 13.5 - 16.5 13.5 - 18.0 13.5 - 18.0 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 21.6 - 28.8 21.6 - 28.8 25.2 - 30.8 25.2 - 30.8 25.2 - 30.8 25.2 - 33.6 25.2 - 33.6 43.2 - 52.8 43.2 - 52.8 43.2 - 52.8 43.2 - 52.8 43.2 - 52.8 43.2 - 52.8
JWS Outline Drawing Max Load Line Ripple Eff. Curr. Reg mV Reg mV Noise (typ)% 60 120 10 15 20 30 60 120 10 15 20 30 60 120 16.7 50 100 68 5.6 11.2 34 68 4.3 6.3 8.5 13 27 53 3.5 5 7 10 22 43 2.2 3.2 4.5 6.5 14 27 2 3.6 5.5 12 23 1.1 1.6 2.1 3.3 6.5 13
20 30 40 40 40 40 20 30 40 40 40 40 20 30 48 36 36 48 76 72 54 54 96 96 96 96 48 72 120 120 120 120 60 90 150 150 150 150 144 144 160 160 160 168 168 240 240 240 240 288 288
20 20 20 20 20 20 20 20 20 20 20 20 20 20 24 24 24 32 36 36 36 36 48 48 48 48 48 48 60 60 60 60 60 60 96 96 96 96 96 96 112 112 112 112 112 192 192 192 192 192 192
120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 150 120 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 200 200 200 200 350 350
60 61 65 67 67 67 68 70 74 74 75 75 74 75 75 74 75 77 74 75 76 77 76 76 76 77 76 80 77 77 77 78 77 81 79 79 79 80 80 82 79 79 80 80 82 79 79 79 80 80 83
WHFRONT VIEWH (BOTH SIDES)SIDE VIEWW MOUNTING SURFACED
See website for detailed drawing.
Dimensions Table JWS50 JWS75 JWS100 JWS150 JWS300 JWS600
Height (H)Width (W)Depth (D)
1.45” 1.65” 1.97” 2.56” 3.62” 3.62”
3.35” 3.62” 3.62” 3.62” 4.72” 6.29”
6.25” 6.88” 7.40” 7.80” 7.48” 7.90”
Other Industrial Products
OptionsHWS LZSA DLP/DSP/DPPSuffixDescriptionBlank /A* /B /C /R
Screw terminals, no cover (JWS50 - JWS150) Screw terminals, cover (JWS50 - JWS150) Molex terminals, no cover (JWS50 & JWS75) Molex terminals, cover (JWS50 & JWS75) Remote On / Off (JWS50 - JWS150)
- Example Note
- JWS50-5/RA * Standard US stock item.
15W to 1800W Single output 500 to 1500W Single output 10 to 480W DIN Rail Mount
For Additional Information, please visit us.tdk-lambda.com/lp/products/jws-series.htm
Not recommended for new designs - see HWS series
1-800-526-2324 • www.us.tdk-lambda.com/lp/
12
Revision A7: Feb 2012
Page3of 3
Open in the PDF
The text of page 3, from the PDF itself
Mouser Electronics Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
TDK-Lambda: JWS10012 JWS10012/A JWS10012/RA JWS10015 JWS10015/A JWS10015/RA JWS10024 JWS10024/A JWS10024/R JWS10024/RA JWS1003 JWS1003/A JWS1003/R JWS1003/RA JWS10048/A JWS10048/R JWS10048/RA JWS1005 JWS1005/A JWS1005/RA JWS1006/A JWS1009/A JWS120P24 JWS120P24/508 JWS120P48 JWS15012/A JWS15012/R JWS15012/RA JWS15015 JWS15015/A JWS15015/R JWS15015/RA JWS15024/RA JWS15028/A JWS1503 JWS1503/A JWS15048 JWS15048/R JWS15048/RA JWS1505 JWS1505/A JWS1505/R JWS1505/RA JWS30012 JWS3002 JWS30024 JWS30028 JWS3003 JWS30048 JWS3005 JWS3006 JWS3009 JWS5012 JWS5012/A JWS5012/C JWS5012/R JWS5012/RA JWS5012/RB JWS5012/RC JWS5015 JWS5015/A JWS5015/RA JWS5015/RB JWS5015/RC JWS5024 JWS5024/A JWS5024/B JWS5024/R JWS5024/RA JWS5024/RB JWS5024/RC JWS503 JWS503/A JWS503/B JWS503/C JWS503/R JWS503/RA JWS5048 JWS5048/B JWS5048/C JWS5048/R JWS5048/RA JWS5048/RB JWS505 JWS505/A JWS505/B JWS505/RA JWS505/RC JWS509/A JWS60012 JWS6002 JWS60024 JWS60028 JWS6006 JWS7512 JWS7512/B JWS7512/R JWS7512/RA JWS7512/RB JWS7515