TDK-Lambda US data sheet (Revision A7, February 2012) for the JWS Series of single output industrial power supplies, models JWS50, JWS75, JWS100, JWS150, JWS300 and JWS600. It gives the shared specifications, a model table by output voltage, a dimension table and the ordering options, and marks the series as not recommended for new designs.

What it is
JWS Series single output industrial power supply p. 1
Input
Universal input, 85 - 265VAC (47 - 63Hz) or 120 - 330VDC p. 1
Power factor
Power factor corrected p. 1
Cooling
JWS50 - JWS150 convection; JWS300 and JWS600 internal fan p. 1
Isolation test
Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA), Output to Ground 500VAC (100mA) for 1 min p. 1
EMI
Level B EMI; EN55011 / EN55022-B, FCC Class B, VCCI-B p. 1
Approvals
The sheet lists UL60950-1, CSA C22.2 No. 60950-1, EN60950-1, VDE0160 and CE Mark p. 1
JWS50 versions
JWS50-3/A, JWS50-5/A, JWS50-9/A, JWS50-12/A, JWS50-15/A, JWS50-24/A, JWS50-28/A, JWS50-48/A p. 2
Options
Screw terminals with or without cover (JWS50 - JWS150); Molex terminals with or without cover (JWS50 & JWS75); Remote On / Off (JWS50 - JWS150) p. 2

What this sheet walks you through

  • Choosing a model by output voltage p. 2
  • Dimensions table and outline drawing p. 2
  • Ordering options and their suffixes p. 2

Good to know

  • The sheet marks the JWS series as not recommended for new designs and points to the HWS series. p. 1, 2

Questions this sheet answers

What input voltage does the TDK-Lambda JWS50 accept?

The JWS series takes 85 - 265VAC at 47 - 63Hz, or 120 - 330VDC. p. 1

Does the JWS50 need a fan?

No. The sheet lists convection cooling for JWS50 - JWS150; only the JWS300 and JWS600 have an internal fan. p. 1

Is the TDK-Lambda JWS series still recommended?

The sheet says it is not recommended for new designs and refers to the HWS series. p. 1

What other output voltages does the JWS50 come in?

The model table lists JWS50-3/A, -5/A, -9/A, -12/A, -15/A, -24/A, -28/A and -48/A. p. 2

The file

Size and text

Pages2
PDF182 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of TDK JWS50 Spec Sheet

The text of page 1, from the PDF itself

JWS Series Single Output Industrial Power Supplies Features u 5 Year Warranty u Power factor Corrected u Approved to VDE0160 Machinery Directive u Universal Input (85 - 265VAC) u Level B EMI

Key Market Segments & Applications u Factory Automation Process Control, NC-Machining, Automotive, Packaging Equipment, Materials Handling, Chemical Processing, Robots u Test & Measurement Burn-in & Test, Automated Test, Instrumentation, Measurement, Detection

Not recommended for new designs - see HWS series Specifications Model Input Voltage range Inrush Current (100 / 200VAC) Power Factor Temperature Coefficient Overcurrent Protection Overvoltage Protection Hold Up Time (Typ) Leakage Current (max) Remote Sense Remote On / Off AC Power Fail Parallel Connection Operating Temp. (open frame) Operating Temp. (with cover) Storage Temperature Operating Humidity Storage Humidity Cooling Withstand Voltage

(1) (1)

Isolation Resistance Vibration (non operating) Shock Safety Agency Approvals Conducted & Radiated EMI Recommended EMI Filter Weight (Typ) Size (WxHxD) Warranty

JWS50

A V ms mA g mm -

JWS75 JWS100 JWS150 JWS300 JWS600 85 - 265VAC (47 - 63Hz) or 120 - 330VDC 14 / 28 25 / 50 20 / 40 Meets EN61000-3-2 <0.02%/°C >105% Yes 20 0.75 No Yes Specify as Option /R Standard Not Available Standard Not Available Avail. JWS300 & 600 only -10ºC~+60ºC, derate linearly to 60% load from 50ºC~60ºC -10ºC~+50ºC, derate linearly to 60% load from 40ºC~50ºC (JWS50-150) -10ºC~+65ºC, derate linearly to 55% load from 50ºC~65ºC (JWS300-600) -30 to +85ºC 30 - 90% RH 10 - 90% RH 10 - 95% RH JWS50 - JWS150 Convection, JWS300 & JWS600 Internal fan Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA), Output to Ground 500VAC (100mA) for 1 min. >100M at 25ºC & 70%RH, Output to Ground 500VDC 10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour < 196.1 m/s2 UL60950-1, CSA C22.2 No. 60950-1, EN60950-1, VDE0160, CE Mark, Built to meet DENTORI EN55011 / EN55022-B, FCC Class B, VCCI-B MAW1202-22 MAW1203-22 MB1210 MB1216 350 450 650 850 1900 3000 See side 2 Five Years

(1) Non condensing

1-800-526-2324 • www.us.tdk-lambda.com/lp/

11

Disclaimer: us.tdk-lambda.com/lp/legal.htm

Page 2 of TDK JWS50 Spec Sheet

The text of page 2, from the PDF itself

JWS Series Model Derating* Model

Voltage

Adjust Range

JWS300-2 JWS600-2 JWS50-3/A JWS75-3/A JWS100-3/A JWS150-3/A JWS300-3 JWS600-3 JWS50-5/A JWS75-5/A JWS100-5/A JWS150-5/A JWS300-5 JWS600-5 JWS100-6/A JWS300-6 JWS600-6 JWS600-8 JWS50-9/A JWS100-9/A JWS300-9 JWS600-9 JWS50-12/A JWS75-12/A JWS100-12A JWS150-12/A JWS300-12 JWS600-12 JWS50-15/A JWS75-15/A JWS100-15/A JWS150-15/A JWS300-15 JWS600-15 JWS50-24/A JWS75-24/A JWS100-24/A JWS150-24/A JWS300-24 JWS600-24 JWS50-28/A JWS100-28/A JWS150-28/A JWS300-28 JWS600-28 JWS50-48/A JWS75-48/A JWS100-48/A JWS150-48/A JWS300-48 JWS600-48

2.0V 2.0V 3.3V 3.3V 3.3V 3.3V 3.3V 3.3V 5.0V 5.0V 5.0V 5.0V 5.0V 5.0V 6.0V 6.0V 6.0V 8.0V 9.0V 9.0V 9.0V 9.0V 12.0V 12.0V 12.0V 12.0V 12.0V 12.0V 15.0V 15.0V 15.0V 15.0V 15.0V 15.0V 24.0V 24.0V 24.0V 24.0V 24.0V 24.0V 28.0V 28.0V 28.0V 28.0V 28.0V 48.0V 48.0V 48.0V 48.0V 48.0V 48.0V

1.8 - 2.4 1.8 - 2.4 2.85 - 3.63 2.85 - 3.63 2.85 - 3.63 2.85 - 3.63 2.97 - 3.96 2.97 - 3.96 4.5 - 5.5 4.5 - 5.5 4.5 - 5.5 4.5 - 5.5 4.5 - 6.0 4.5 - 6.0 5.4 - 6.6 5.4 - 7.2 5.4 - 7.2 7.2 - 9.6 8.1 - 9.9 8.1 - 9.9 8.1 - 10.8 8.1 - 10.8 10.8 - 13.2 10.8 - 13.2 10.8 - 13.2 10.8 - 13.2 10.8 - 14.4 10.8 - 14.4 13.5 - 16.5 13.5 - 16.5 13.5 - 16.5 13.5 - 16.5 13.5 - 18.0 13.5 - 18.0 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 21.6 - 28.8 21.6 - 28.8 25.2 - 30.8 25.2 - 30.8 25.2 - 30.8 25.2 - 33.6 25.2 - 33.6 43.2 - 52.8 43.2 - 52.8 43.2 - 52.8 43.2 - 52.8 43.2 - 52.8 43.2 - 52.8

JWS Outline Drawing Max Load Line Ripple Eff. Curr. Reg mV Reg mV Noise (typ)% 60 120 10 15 20 30 60 120 10 15 20 30 60 120 16.7 50 100 68 5.6 11.2 34 68 4.3 6.3 8.5 13 27 53 3.5 5 7 10 22 43 2.2 3.2 4.5 6.5 14 27 2 3.6 5.5 12 23 1.1 1.6 2.1 3.3 6.5 13

20 30 40 40 40 40 20 30 40 40 40 40 20 30 48 36 36 48 76 72 54 54 96 96 96 96 48 72 120 120 120 120 60 90 150 150 150 150 144 144 160 160 160 168 168 240 240 240 240 288 288

20 20 20 20 20 20 20 20 20 20 20 20 20 20 24 24 24 32 36 36 36 36 48 48 48 48 48 48 60 60 60 60 60 60 96 96 96 96 96 96 112 112 112 112 112 192 192 192 192 192 192

120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 150 120 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 200 200 200 200 350 350

60 61 65 67 67 67 68 70 74 74 75 75 74 75 75 74 75 77 74 75 76 77 76 76 76 77 76 80 77 77 77 78 77 81 79 79 79 80 80 82 79 79 80 80 82 79 79 79 80 80 83

WHFRONT VIEWH (BOTH SIDES)SIDE VIEWW MOUNTING SURFACED

See website for detailed drawing.

Dimensions Table JWS50 JWS75 JWS100 JWS150 JWS300 JWS600

Height (H)Width (W)Depth (D)

1.45” 1.65” 1.97” 2.56” 3.62” 3.62”

3.35” 3.62” 3.62” 3.62” 4.72” 6.29”

6.25” 6.88” 7.40” 7.80” 7.48” 7.90”

Other Industrial Products

OptionsHWS LZSA DLP/DSP/DPPSuffixDescriptionBlank /A* /B /C /R

Screw terminals, no cover (JWS50 - JWS150) Screw terminals, cover (JWS50 - JWS150) Molex terminals, no cover (JWS50 & JWS75) Molex terminals, cover (JWS50 & JWS75) Remote On / Off (JWS50 - JWS150)

Example Note
JWS50-5/RA * Standard US stock item.

15W to 1800W Single output 500 to 1500W Single output 10 to 480W DIN Rail Mount

For Additional Information, please visit us.tdk-lambda.com/lp/products/jws-series.htm

Not recommended for new designs - see HWS series

1-800-526-2324 • www.us.tdk-lambda.com/lp/

12

Revision A7: Feb 2012