Spec sheet · Tri-Tronics
Tri-Tronics SmartEye Mark II Photoelectric Sensor Spec Sheet
Spec sheet2 pagesPDF 300 KB
Both pages are below, each with its text.
Filed with · 1 model
Also filed with these models on the old site
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
A two-page specification and setup sheet for the SMARTEYE Mark II photoelectric sensor. It covers the sensor in general and does not name the SER version the site files it under. It gives the electrical, optical and environmental specifications and a short setup procedure for the offset adjustment.
- Type
- Photoelectric sensor p. 1
- Supply voltage
- 12 to 24 VDC, polarity protected p. 1
- Current draw
- 85 mA, not counting the load p. 1
- Outputs
- One NPN (sinks up to 150 mA) and one PNP (sources up to 150 mA); momentary short circuit protected p. 1
- Operate mode
- Light/dark switch selects light ON or dark ON operation p. 1
- Response time
- 50 microseconds light state; 140 microseconds dark state p. 1
- Light source
- Pulsed LED at 45 kHz: infrared 880nm, red 660nm, white or blue 480nm p. 1
- Indicators
- Red output LED, green EDR LED and a 10-bar LED contrast indicator p. 1
- Ambient temperature
- -40°C to 70°C (-40°F to 158°F) p. 1
- Housing
- Chemical resistant, high impact polycarbonate, epoxy encapsulated p. 1
- Enclosure ratings
- The manual states NEMA 4X, 6P and IP67 enclosure ratings p. 1
- Hysteresis
- Less than 400 millivolts p. 1
- Adjustment
- Offset/EDR control sets the contrast indicator level and works as the sensitivity adjustment p. 1
What this sheet walks you through
- Setting up the Mark II with the offset adjustment p. 2
- Re-adjusting the offset when the dark state does not read zero p. 2
- Understanding contrast in beam break and beam make modes p. 2
- Reading the output, EDR and contrast indicators p. 1
Good to know
- Because the Mark II is more sensitive, the original SMARTEYE setup procedure must be changed. p. 2
- On rare occasions it may be advisable to adjust the offset while input events are ongoing. p. 2
- The sheet says to consult the factory for RoHS compliance. p. 1
Questions this sheet answers
What supply voltage does the SMARTEYE Mark II need?
12 to 24 VDC, polarity protected; it draws 85 mA not counting the load. p. 1
How do I set up a SMARTEYE Mark II sensor?
Aim it at the target in the bright state, turn the offset to read 10 on the contrast indicator, then turn it a further quarter turn clockwise. p. 2
What outputs does the SMARTEYE Mark II have?
One NPN output that sinks up to 150 mA and one PNP output that sources up to 150 mA. p. 1
How fast does the SMARTEYE Mark II respond?
50 microseconds in the light state and 140 microseconds in the dark state. p. 1
What temperature range is the SMARTEYE Mark II rated for?
-40°C to 70°C (-40°F to 158°F). p. 1
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
Specifications SUPPLY VOLTAGE
- 12 to 24 VDC
- Polarity Protected CURRENT REQUIREMENTS
- 85 mA (exclusive of load) OUTPUT TRANSISTORS
- (1) NPN and (1) PNP Output transistor:
- NPN: Sink up to 150 mA
- PNP: Source up to 150 mA
- Momentary short circuit protected
- Outputs protected from pulsing during power up
- Light/dark switch determines Output Status: Light = Light “ON” operate Dark = Dark “ON” operate RESPONSE TIME
- Minimum duration of input event
- Light state response = 50 microseconds
- Dark state response = 140 microseconds
- Leading edge Variation less than 20 microseconds HYSTERESIS
- Less than 400 millivolts for maximum sensitivity and resolution
LED LIGHT SOURCE
- Pulse modulation rate 45 KHZ
- Choice of color: A. Infrared = 880nm B. Red = 660nm C. White = Broadband Color Spectrum D. BIue = 480nm LIGHT IMMUNITY
- Responds to sensor's pulsed modulated light source
- Immune to most ambient light ® ADJUSTMENT OFFSET/EDR
- Sets initial level on CONTRAST INDICATOR in relation to mid-scale switch point of 5 – functions as sensitivity adjustment
- Controls Enhanced Dynamic Range circuit (EDRTM ) which functions to avoid saturation
INDICATORS
- OUTPUT INDICATOR
- RED LED illuminates and the NPN or PNP outputs switch to the opposite state when returned light level exceeds “5” on the CONTRAST INDICATOR
- EDR™ INDICATOR - Intensity of GREEN LED provides indication of where in the dynamic operating range the offset, EDR TM adjustment has been set
- FULLY LlT: Operating near saturation
- OFF: Operating near maximum sensing range
- CONTRAST INDICATOR – Displays scaled reading of sensor's response to contrasting light levels (light vs. dark) on a 10 bar LED display AMBIENT TEMPERATURE
- - 40°C to 70°C (- 40°F to 158°F) RUGGED CONSTRUCTION
- Chemical resistant, high impact polycarbonate housing
- Waterproof, NEMA 4X, 6P and IP67 enclosure ratings
- Epoxy encapsulated for mechanical strength Product subject to change without notice. Consult Factory for RoHS Compliance.
Connections and Dimensions
SMARTEYE® MARK II PHOTOELECTRIC SENSOR
800-237-0946
Rev. 2 070-0067
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
CONGRATULATIONS! You have just purchased a high performance SMARTEYE Mark II photoelectric sensor. The SMARTEYE Mark II has higher speed of response (50 microseconds) and even higher gain than the original SMARTEYE. These improved performance attributes allow the sensor to resolve the most difficult sensing tasks. As a result of the Mark II sensor’s increased sensitivity, it is necessary to alter the original SMARTEYE setup procedure. Simplified Setup Procedures NOTE: The original SMARTEYE setup procedures called for a Light State setting of 9 to 10 on the Contrast Indicator. To obtain the correct Light State setting on a SMARTEYE Mark II, please follow these simple instructions: 1. Aim the sensor at the target in the bright-state condition. 2. Adjust the offset adjustment to obtain a reading of 10. Then, continue to rotate the adjustment clockwise ¼ of a turn. This is generally the only setup procedure requirement. However, if in turn, the Dark State does not result in a reading of zero (all LED’s off), it may be necessary to re-adjust the offset so that the Light State/Dark State contrast deviation, as displayed on the Contrast Indicator, straddles the switchpoint of “5”. On rare occasions when this procedure is required, it may be advisable to make the offset adjustment in dynamic conditions when input events are ongoing.
Contrasting Light Levels When operating in the Beam Break mode, the intensity of the light beam reaching the receiving lens is in its brightest or lightest state condition before an object in introduced into the light beam path. Introducing an object into the light beam path will block out or diminish the intensity of the received light beam, resulting in the darkest state condition. In the Beam Make mode, the darkest state condition is before an object is placed in the light beam path. The lightest state condition is when an object is introduced into the light beam path so as to bounce or reflect the light beam to the receiving lens.
The amount of difference or deviation of the intensity of the light beam in its lightest state condition vs. the intensity of the received light beam in the darkest state is called “Contrast”. The sensing task of any digital switching photoelectric sensor is to respond to and resolve the difference between the contrasting light levels and switch its output accordingly. These contrasting light levels define the degree of difficulty of the sensing task.
070-0093 Rev.2 12-07