A one-sheet Turck reference drawing (identification number 1627297, revision B) for the BI20U-CA40-AP6X2-H1141/S1590W/BS2.0 Uprox sensor on its BS-2.0 mounting bracket. It gives the wiring diagram, dimensions, electrical specifications, sensing range, LED meanings and housing materials.

Type
3-wire DC self-contained sensor, normally open output (AP6X2) p. 1
Sensing distance
20 mm (.787 in) nominal; embeddable (shielded) p. 1
Operating voltage
10-30 VDC, ripple under 10% p. 1
Load current
Under 200 mA continuous; voltage drop under 1.8 V at 200 mA p. 1
Protection
Short-circuit and overload protected; reverse polarity and wire-break protection p. 1
Switching frequency
260 Hz p. 1
Operating temperature
Up to +70 °C (+32 F to +158 F) p. 1
LEDs
Green: power on; yellow: output energized; yellow flashing: short-circuit warning p. 1
Hysteresis
3-15% (5% typical); repeatability under 2% of rated distance p. 1
Enclosure
The drawing states NEMA 1, 3, 4, 6, 13 and IEC IP67 p. 1
Mounting
BS-2.0 mounting bracket; sensing head turns to 5 sensing positions p. 1
Materials
Housing GD-ALSI12; front cap thermoset plastic laminate p. 1
Currents
No-load current 15 mA; time delay before availability under 8 ms p. 1
Weld fields
Uprox sensor with weld field immunity p. 1

What this sheet walks you through

  • Wiring the AP6X2 output p. 1
  • Sensor and bracket dimensions p. 1
  • Reading the status LEDs p. 1

Good to know

  • The drawing is a source drawing for reference only and is not to be scaled. p. 1
  • The load current must stay under 200 mA. p. 1

Questions this sheet answers

What is the sensing distance of the BI20U-CA40-AP6X2-H1141?

20 mm (.787 in) nominal, and it can be mounted embedded (shielded). p. 1

What voltage does the BI20U-CA40-AP6X2-H1141 need?

10 to 30 VDC with under 10% ripple. p. 1

Is the BI20U-CA40-AP6X2-H1141 normally open or normally closed?

Normally open: a 3-wire DC output that is short-circuit and overload protected. p. 1

What does a flashing yellow LED mean on this sensor?

A short-circuit warning. Steady yellow means the output is energized and green means power on. p. 1

The file

Size and text

Pages1
PDF101 KB
TextThe pages are scans; their text was read by OCR, which may hold reading errors.

Every page · 1

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Turck BI20U-CA40-AP6X2-H114/S1590W/BS2.0 and BI20U-CA40-AP6X2-H1141 Spec Sheet

The text of page 1, read from a scan by OCR; it may hold reading errors

WIRING DIAGRAM

OUTPUT: AP6X2

SHORT - CIRCUIT AND OVERLOAD PROTECTED

M12Xx1

(2X) .209 x .287 [5.3 x 7.3] SLOT

472 [12.0]6.886 [22.5]1.339

BS - 2.0 MOUNTING BRACKET

[34.0], - SPECIFICATIONS

OPERATING VOLTAGE10-30 VDCRIPPLE<10%

DIFFERENTIAL TRAVEL (HYSTERESIS)

3-15% (5% TYPICAL)

VOLTAGE DROP ACROSS CONDUCTING SENSOR

<1.8 V at 200 mA

OUTPUT FUNCTION

NORMALLY OPEN 3-WIRE DC SELF-CONTAINED

1.575 [40.0]

SHORT - CIRCUIT PROTECTED YES CONTINUOUS LOAD CURRENT <200 mA OFF - STATE (LEAKAGE) CURRENT <O0.1 mA NO-LOAD CURRENT 15 mA TIME DELAY BEFORE AVAILABILITY <8 ms

POWER- - ON EFFECT PROTECTION

PER IEC 947 - 5- - 2

REVERSE POLARITY PROTECTION INCORPORATED WIRE - BREAK PROTECTION INCORPORATED PROTECTION AGAINST TRANSIENTS EN 60947 - -5- - 7 1.575 [40.0 ° ° 3 ° [ ] OPERATING TEMPERATURE oc TO +70°C (+32 F TO +158 F) ENCLOSURE MEETS NEMA 1, 3, 4, 6, 13 AND IEC IP67 SHOCK 30 g, 11 ms 55 Hz, 1 AMPLITUDE VIBRATION (iN ALL 3 PLANES) GREEN: POWER ON LED FUNCTION YELLOW: OUTPUT ENERGIZED YELLOW FLASHING: SHORT - CIRCUIT WARNING RATED OPERATING DISTANCE(Sn) 20 mm = .787” (NOMINAL) SWITCHING FREQUENCY 260 Hz 1.575 [40.0] REPEATABILITY <2% of RATED OPERATING DISTANCE SU 2.559 [65.0] EMBEDDABLE (SHIELDED) YES SOURCE DRAWING - FOR REFERENCE ONLY RELATED DOCUMENTS 3RD ANGLE BRO ANGLE THIS DRAWING IS 3000 CAMPUS DRIVE

PROPERTY OFTURCK INC. USE OFTeese Een

MINNEAPOLIS, MN 55441 1-800-544-7769

1.

2. THIS DOCUMENT NOTES: (763) 553-7300

3. © €-+ OE RMISSION IS High Technology Sensors and Automation Controls (763) 553-0708 fox 1. SENSING HEAD CAN ROTATE TO 5 DIFFERENT SENSING POSITIONS. ‘ PROHIBITED” turck.com

MATERIAL DRFT RDS DATE 04/30/02 DESCRIPTION 2. UPROX HAS WELD FIELD IMMUNITY, SENSOR IS SUITABLE FOR USE SEE NOTES ALL piensions TESS <uE BI2Z0U - CA40 - AP6X2 - H1141/S1590W/BS2.q ON RESISTANCE MACHINES. DISPLAYED. ON THIS 1=1.3

DRAWING ARE FOR UNIT OF MEASUREMENT 3. MATERIAL: HOUSING, GD - ALSI12 ANSE REFERENCE ONLY IDENTIFICATION NO, REV FRONTCAP, THERMOSET PLASTIC LAMINATE CONTACT TURCK INCH [ MILLIMETER | 1627297 FOR MORE B

B | UPDATE OPERATING TEMPERATURE, SEE ECO RW] 12/09/10] 33512 INFORMATION REV | DESCRIPTION BY DATE ECO NO. DO NOT SCALE THIS DRAWING FILE: M1627297 | SHEET 1 OF 1