A specification sheet for the Wedgewood Model 722 Conductivity and Temperature Monitor, which works with Model B600 Series flow cells to measure the conductivity and temperature of process liquids in-line. It gives ranges, inputs, outputs, power and size, and how to build a part number.

Type
In-line conductivity and temperature monitor for Model B600 Series flow cells p. 1
Conductivity ranges
Two selectable ranges: 0-200/0-20 mS/cm or 0-100/0-10 mS/cm, by factory calibration variant p. 2
Inputs
4 electrode conductivity input; 1000 ohm RTD temperature input p. 2
Conductivity outputs
4-20 mA tracking the selected range (0-600 ohm load); 0-2 Vdc tracking full range (10 KOhm min) p. 2
Temperature outputs
4-20 mA and 0-2 Vdc, both tracking 0 to 100°C p. 2
Power
115/230 Vac +/- 15%, 50/60 Hz, 15 VA; optional 18-36 VDC, 10 W p. 2
Operating environment
0-55°C; 0-90% RH p. 2
Size and mounting
35mm DIN rail mount, 74 x 119 x 100mm (2.91" x 4.69" x 3.94") p. 2
Isolation
Conductivity sensor galvanically isolated from outputs and power supply p. 2
Temperature compensation
Built-in curves for NaCl and KCl p. 2
Calibration controls
Front panel conductivity Zero and Span, temperature Zero and Cal p. 1
Part number codes
Range T: 0-200mS/cm, U: 0-100mS/cm; flowcell 6: Kynar, 7: stainless steel; power C: 115/230Vac, D: 24Vdc p. 3

What this sheet walks you through

  • Calibrating with the front panel controls p. 1
  • Building a part number by range, flowcell, power supply and cable p. 2, 3

Good to know

  • Temperature compensation can be disabled with an internal jumper. p. 1
  • Sensor cables come in 10 ft and 25 ft lengths only. p. 3

Questions this sheet answers

What does the Wedgewood Model 722 measure?

The conductivity and temperature of a process liquid in-line, using a Model B600 Series flow cell. p. 1

What conductivity ranges does the Model 722 have?

Two selectable ranges in one of two factory variants: 0-200/0-20 mS/cm or 0-100/0-10 mS/cm. p. 2

What power does the Wedgewood Model 722 need?

115/230 Vac +/- 15%, 50/60 Hz, 15 VA, or an optional 18-36 VDC, 10 W supply. p. 2

What temperature sensor does the Model 722 use?

A 1000 ohm RTD input. p. 2

The file

Size and text

Pages3
PDF32 KB
TextText from the PDF itself.

Every page · 3

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Wedgewood Model 722 Spec Sheet

The text of page 1, from the PDF itself

Model 722 Conductivity and Temperature Monitor Overview The Model 722 Conductivity and Temperature monitor is used in conjunction with the WEDGEWOOD Model B600 Series flow cells to measure the conductivity and temperature of any process liquid in-line.

1

10

Model 722 Conductivity / Temperature Monitor Conductivity

TemperatureZeroCalSpanZero

Wedgewood Technology, Inc. The Model 722 is available with one of two 11 20 full scale measurements: 0 to 100 mS/cm and 0 to 200 mS/cm. In addition to these ranges, the user can select, via contact Temperature Compensation closure, a second range that is 10% of the supplied full scale. The temperature range The Model 722 features built in temperature is 0 to 100°C. compensation for the conductivity measurement. Two curves are available, The instrument is designed to provide one to compensate for NaCl and the other measurement elements in an overall for KCl. The compensation can be disabled control scheme. It is ideally suited for if required by internal jumper. The computerized process plant where user compensation type is selected by hard wire interface with the process is through loop or contact closure from a PLC or computer terminals and MMI nodes rather similar device. than directly with the measurement element. The electronics used at the heart of the Model 722 are state-of-the-art solid state Outputs low-noise amplifiers, signal generators and There are four analog outputs from the unit, a RISC CPU, allowing accurate, repeatable two for conductivity and two for and reliable measurement. temperature. The temperature measurement has a Voltage output and a 4 All calibration of the instrument is done with to 20mA current signal following the full adjustments to controls on the front panel. range of the instrument while the Four controls are available - Conductivity conductivity loop has a Voltage and a Zero and Span and temperature Zero and current output tracking the selected Cal. measurement range. An optional NEMA 4X/IP66 polished All electrical connections are through the stainless steel enclosure is available to two strips of terminal screws on the top enable the transmitter to be mounted locally face of the instrument. in the field.

Page 2 of Wedgewood Model 722 Spec Sheet

The text of page 2, from the PDF itself

722 Features and Specifications Model 722 Features Two Selectable Full Scale Ranges Remote Range Change Operation Built-In Temperature Compensation for NaCl and KCl 1000 ohm RTD Input for Greater Accuracy

All Calibration Controls Accessible Externally Maximum Range of 200 mS/cm

Model 722 Specifications Signal Inputs Ranges Calibrated Conductivity Accuracy Conductivity Linearity Temperature Accuracy Input Isolation Conductivity Signal Outputs Temperature Signal Outputs Power Operating Environment Dimensions

4 Electrode Input for Conductivity and 1000 ohm RTD Input for Temperature 2 Selectable Ranges on each Instrument. Two Factory Calibration Variants Available: 0 - 200/0 - 20 mS/cm or 0 - 100/0 - 10 mS/cm 2% of Range

2% of range 0.5°C Conductivity Sensor is galvanically Isolated from Outputs and Power Supply 4 - 20 mA Tracking Range Selected (0 - 600 ohm load) 0 - 2 Vdc Tracking Full Range (10 KOhm load min) 4 - 20 mA Tracking 0 to 100°C (0 - 600 ohm load) 0 - 2 Vdc Tracking 0 to 100°C (10 KOhm load min) 115/230 Vac +/ - 15%, 50/60 Hz, 15 VA, (Optional 18 - 36 VDC, 10 W) Temperature 0 - 55°C Humidity 0 - 90% RH 35mm DIN Rail Mount Enclosure 74 x 119 x 100mm (2.91” x 4.69” x 3.94”)

Part Number Selection

Page 3 of Wedgewood Model 722 Spec Sheet

The text of page 3, from the PDF itself

7 2 2-Cable Length F Feet

Enter 3 digit value for length ð Available lengths: 10ft, 25ft only

N Noneð - --

Cable Type -T To BT721 Cond./Temp. Sensor -N None Transmitter Range T- 0 - 200mS/cm U- 0 - 100mS/cm Transmitter Setup 6 Kynar Flowcell 7 Stainless Steel Flowcell Power Supply C 115/230Vac D 24Vdc