| a ie SL

HOME AREA

2np, L__

Fig 3 51

The home return completion (ZPM) signal is turned on when a home return motion is completed, but is turned off under the following conditions

Mode switching over Return Home signal ON

Both Motionpack alarm (ALM1) and error reset (ERS) ON

Emergency stop [see (Note) on Fig 4 7]

With Motionpack-33, if the motion signals for both forward and reverse directions are turned off, the machine stopped for emergency With a circuit connected to a DB unit, if both the forward and reverse OTs are turned off, the machine stopped for emergency The DB brake is apphed for both directions cc 13}, 3 FORWARD MOTION READY 19, _ - _. REVERSE o o - - - ? MOTION READY 204 H Motionpack Fig 3 52

The return-to-origin operation is defined by parameters Pr 70 to Pr 78 as summarized in Table 3 14 Refer to par 3 3 for the details of parameters

Table 3 14 Return Home Parameters

Parameter Description Unit No Pr 70 Return home mode Pr 71 Home position coordinate | No of pulses Pr 72 Wait position Speed unit Pr 73 Return home speed Speed unit Pr 74 Return home creep speed | Speed unit Pr 75 Return home torque hmit | $ Pr 76 Coasting allowance No of pulses Pr 77 Permissible error No of pulses Pr 78 Butting time 10 msec

It is possible to select the origin LS as an A> or B-contact by connections to terminals and of the CB connector

’ ’ ’

3 4 1 7 Motionpack-33 Coordinate System

Motionpack-33 has 10 coordinate systems (TO to T9) Coordinate system TO is defined by PG home position pulse and home position LS Coordinate systems Tl to T9 are based on Coordinate system TO

Method of Coordinate System Setting

Q) Presetting offset amount in parameter 20 (coordinate system T8) and parameter 22 (coordinate system T6) and shifting coordinate system by turning on or off external signal +/- INC

@) Presetting by programmer

G) Coordinate system setting reference G52

Relationship between coordinate system TO and coordinate systems T1 to T9 are determined by shift amount register (Sn) corresponding to axis No and offset register (On)

Fig 3 51 shows coordinate setting and register

SHIFT REGISTER

4 GS2x Tn n Sn Tn *

PROGRAMMER OFFSET REGISTER n PARAMETER 20 (OR 22) On

* OFFSET REGISTER 1S ONLY WITH T8 AND T9

Fig 3 53

Each coordinate system 1s not set by the corresponding program but the same coordinate system can be set in any program

Shift amount register, offset amount register and Coordinate system shift

Where coordinate value at coordinate Tn 1s tn, shift register corresponding to Tn 1s Sn, coordinate value 1s obtained from the following formula tn= totSn

Example

When shift register (S1) at coordinate system T1 is 100, the relationship between coordinate systems TQ and T] 1s as shown in Fig 3 52 in mm 150 + « To . v1 100 250 250 Fig 3 54

55

Page 62 read from a scan by OCR; it may hold reading errors

3 4 14 7 Motionpack-33 Coordinate System (Cont'd) Coordinate value ti of the position of 150mm at coordinate system TO at coordinate system T] 1s ti = te + Sl]

= 150 mm (TO) = 250 mm

+ 100 mm

Setting positive values in Sn shifts the home position of coordinate system Tn in the negative direction This facilitates tool length compensation in setting coordinate system by shift amount

Setting tool length in shift amount register Sn sets the coordinate system of which home position is shifted by the length

Coordinate systems T8 and T9 are provided with offset amount registers (O08, 09) 1n addition to shift amount registers (S8, S9)

When the coordinate value is tg at coordinate system T8, and the corresponding shift amount registers are S8 and O8, te is obtained from the following formula te = to + Sg + Og Example When shift amount register Sg of coordinate system system T, 1s 100mm and offset register Og, 15s 2mm, the relationship between TO and T8 1s as shown in Fig 3 55 momm, 100, 98, 97 te) 30 o - { - « S8=100 O8=-2-N T8 (BEFORE $ 98 128 CORRECTION) | Pr20 O8=( - 2)4(-N IY LC] = T8 ( - !ING 8 INPUT $ (27 ONE TIME) PARAMETER 20=1mm

Fig 3 55

Coordinate value te of the position of 30 mm at coordinate system Tg, 1s ts = to + Sg + Og 30 + 100 + (-2) 128 mm

Coordinate system setting by offset amount apphes to compensation for tool wear Setting tool wear amount shifts the home position by the set value The direction of home position shift 1s positive when offset register 1s negative

56

In coordinate system [I8, the value set to parameter 20 by turning on or off signals +#INC8 (or -INC8) can be added to or retiacted from offset register Setting tool wear compensation per time to parameter 20 and turning on or off signal -INC8 permits automatic compensation The same applies to coordinate system T9

(1) Coordinate system shifting by +INC,-INC signals

With the coordinate system T8, each time +INC8& signal or -INC8 signal turns on correction 1s made in the + or - direction respectively The correction distance 1s set by parameter Pr20 After several corrections, as the total correction amounts to the maximum correction as set by parameter Pr2l, no further correction 1s possible and an answer-back signal for absolute maximum offset (OFM) 1s output When +INC8 anc -INC8 signals are given simultaneously, no correction 1s made, and an answer-back signal, offset 0 (OFR), 1s output

The coordinate svstem T9 1s corrected similarly by +INC9 and -INC9 signals The correction distance 1s set by parameter Pr22 and the maximum correction 1s set by parameter Pr23 When coordinate system T8 or [91s selected, the coordinate values are modified by the sum of the shift (S8 or S9) of the coordinate system itself and the offset (O8 or O9), from the values for the TO coordinate system

EXAMPLE When the coordinate system 18 1s shifted by shift amount (S8) of 100,000 from TO, and its offset (O8) 1s -0 020, the positioia commanded by G01X200 000 in the T8 coordinate system 1s as shown tn Fig 3 56 below 200 T8 COORDINATE SYSTI DISPLAY (A8) b TO COORDINATE SYSTt | 100 000 1 P90 020 | 200 00 DISPLAY (40) I -0 020 1 it =>

100 000_| 0020

Fig 3 56

The related parameters are listed in Table 3 15 For details, see par 3 3 4 Offset Parameters

Table 315 Offset-related Parameter Setting

Parameter Nc Content Unit

20 T8 coordinate single Position command correction unit T8 coordinate mas Position command

21 correction unit

22 T9 coordinite single Position command correction unit

23 T9 coordinate mix Position command correction unit

Page 63 read from a scan by OCR; it may hold reading errors

When an INC signal 1s received, the corres-~ ponding coordinate system 1s corrected (+ or -) by the distance set by the parameter This correction 1s executed while the machine is at standby in the AU1O operation mode When the sum of the values in the offset register 8 exceeds the tmax value after adding the latest increment, an offset +max (OFM) signal is output, and when it 1s below, a +increment made (INCD) signals 1s output

APPROX 50 ms - - ~] 4 INC8&

OR ~ INC8, SN L___ ' INCD OR ow - - - F L__

Fig 3 57

When + and - incremental commands are received simultaneously, the offset register 8 1s zeroed, and an offset 0 (OFR) signal is output qd) When -INC8 1s received before executing +INC8 (INCD or OFM)

LNCS L__ a

OFR | |

(Motionpack -- Sequencer)

Fig 3 58

@) When -INC8 is received after the tINC8 completion signal has been output

INCD OR OFM ; -iNC8 i: | ) OFR |

(Motionpack + Sequencer}

Fig 3 59

124V =>) + INCE a CE 36 3 o - - 4 INCREMENTAL COMMA > CE 37 7 INCE -INCREMENTAL COMMA! CE1 +INCS + INCREMENTAL COMMAI ~INC9 CE 33 rs ~INCREMENTAL COMMA, CE 47 Ovav 48 49, I CD 9 onan NED INCRENENT MADE CD 10 oFre Ca OFFSET DISTANCE 0 1 CD it) OFM OL orrser DISTANCE REAC MAX CO1] +2a4v ~2 H Motronpack . | | _ Fig 3 60

(2) Coordinate system setting by program

In addition to the setting possibility of 11 - T9 coordinate systems by programs with G52, they can also be preset by programs The shift distance of each coordinate system 1s that from the TQ coordinate system

In addition to the offset correction possibility of T8 and T9 coordinate system with :INC8 and +INC9 signals, the prog:am presetting of the initial values 1s also possible When the coordinate system T8 or T9 is used, the position commands specify coordinate values which are corrected by the reduction of the shift distance (S) and the offset distance (O)

When the T& or T9 coordinate is used, all the position commands are corrected for the shift distance (Sn) and the offset distance (On)

"On" is contained in the coordinate systems T8 and T9 only

These preset values are updated by sctting coordinate systems and shifting coordinate systems by INC signals

(a) Setting offset

Select position setting mode

Whenever the POSITION mode switch 1s press- ed, block number 1s indicated as [OLl8 l= [5118] Offset selection 1s indicated by "0" and shift selection by "5" A flashing digit indicates a coordinate number

Select "0" (offset selection), write a coordinate number, and touch switch or The block number indication stops to flash the data display begins to flash

Write an offset value and touch the WRITL switch

Sf

Page 64 read from a scan by OCR; it may hold reading errors

3 41 7 Motionpack-33 Coordinate System

(Cont'd)

coordinate system 1s selected Numbers are in the minimum position command unit

Then touch switch, and the next coordinate system is selected.

Numbers are in the minimum position command unit

(b) Setting shift

Select position setting mode

Touch the to flash

Write a shift value and touch the WRITE

POSITION mode switch, select "5"

(shift selection), write a_coordinate number, and touch the switch or indication stops flashing the data display begins

The block number

(3) Method with a coordinate setting command (G52) See par 3 4 2 7, Coordinate settirg command (G52)

3 4.2 FUNCTION LIST

Ali the function commands have codes consisting of G and two digits The functions of these commands are diverse, commanding positions, feedrates, torque, auxilhary functions, dvell time, coordinate Nos , number of loops, jump destination block Nos , ete , but the length of each block 1s fixed irrespective of the ccmmand switch Then touch switch , and the next word length, Table 3 16 Function Command List Function Function Command Description Command Code Word Pp GOIX F I Positioning | GOl U Move to position X (or U) at speed F and torque hmit I F, I can be omitted cos When ship signi] turns on, cxecution is interrupted, and jumps Skip G06 GO05X Fol to the next block Positioning | Gq? U G05 skip signal EPS5 G06 skip signal EPS6 G07 skip signal EPS7 Positioning 34x F I Move to X (or U) position at speed F and torque I by External | G34 U . When external positioning signal (EXP2) 1s received, the slide Signal 1s positioned there Home Posi- G27?Xx F i Move to X (or U) position at specd F and torque | and chech home G27 tion Check U position at that position Delay for After executing feed command, delay until in-position state 1s In- pesition entered, then, move to next block Delay Goa Delay until time specified by lapses, and then, move to next Delay time block Coordinate G52X = T switching G52 U Set current position as \ (or U) in Tn coordinate system Coordinate G53 G53T Switching into Tn coordinate system Setting Arrival Check | G67 G67P When arnving at X (or U) by skap positioning without skapping, jump to P Repeat calling, subroutine Execute subroutine L times from P Subroutine | cy Gos. P, Call Calling end- specified subroutine Execute subroutine from P until arrival at X (or U) G68x P U _ - Simple jump lock GoaP Go to caccute P bloc G Jump 69 Return from subroutine Return to block next to subroutine call (G68) G69 Signal output Output M signal, and when corresponding M-FIN signal turns on, Aux M M reset M signal output, then, when M-FIN signal turns off, execute Function (M51 to M56) next block M30 wee end Reset In-operation signal (STL), and output M30 signal

58

Page 65 read from a scan by OCR; it may hold reading errors

3 4 2 1 Positioning Command (G01)

es a rrore GO0l Xi ae Gk Shek ek aka FY he ee ee ed I, gt abos uo cor wae Rosl ue ae ak sho ae

G01 positioning x position in absolute value (-9999999 to +9999999)

U position in-incremental value (- 9999999 to +9999999)

F speed (0 to 60000)

I torque limit (10 to 200%)

Unit of position data (X and U) 1s determined by parameters Pr50 and Pr51, and decimal point position, by Pr52

Unit of speed data 1s determined by position - ing command unit and fractional digits (Pr52) See par 3 3

Operation

G01 command gives the movement to position X (or U) in the currently selected coordinate system at speed specified by F and torque I X is shown in absolute value, and U, in incremental value Incremental value shows the move amount from the previous command position to the current command position

SPEED _ REFERENCE 4 EXECUTION OF G01 IN NEXT BLOCK MOTOR Loc, - TIME mm 300 _ - - POSITION | REFERENCE 200, - TIME Fig 3 61 Example Current position 200 mm

Command position 300 mm

Speed 4 m/min

With torque limit (10 to 200%),

GO! X300 000 F4000 1200 in absolute valuc

GO1 U100 000 F4000 1200 in inctemental value

Fig 3 61 shows G01 command execution and motor movement Positioning command 1s linear accel/decel

With a positioning command, the speed designation (F) can be omitted. In this case, the previously specified feedrate is used again (However, after clearing a program, be sure to specify speed in the first feedrate command )} When an override signal (OVR) 1s on, speeds above the one specified by parameter Prl0 are creeped to the speed of parameter Prl0*

The setting range for torque lmit I 1s between 10 and 200 Its unit is % of the rated torque The ratio of programmed 100% torque to the Servopack and motor rated torque is set by parameter Pr53

The same torque limit is applied to both the + and - directions, but it 1s subject to errors up to +108 With a positioning command, the torque limit specification can be omitted In this case, the same value as the previous command 1s used again When the program is cleared, the torque limit 1s switched to 200%

Execution of next block

When the reference pulses for movement to the specified position programmed by G01, Motionpack-33 controller executes the command of the next block Fig 3.61 shows the command in which G01 is programmed in the next block

As shown in Fig 3 61, motor motion follows reference pulses with some delay. On completion of reference pulse distribution, motor motion may not arrive at the specified position when the next block starts to execute

To execute the next block command after motor motion reaches the specified position, insert In-position command (G04) or time delay command (G04D ) See par 3 425 and 3426

The parameters related to positioning are shown in Table 3 17 Table 3 18 shows the servo parameters For detailed setting of each parameter, see par 3 3

Table 3.17 Positioning Parameters

Parameter No Description Unit 45 In-position range Pulse 50 Pulse ratio M 51 Pulse ratio D 52 Decimal point position} No of digits

Thrust ratio 53 = rated thrust/servo % rating * 100%

54 Axis No designation

60 - direction stored Position command stroke limit unit # dire tored

61 ection s Same as above stroke hmit

59

Page 66 read from a scan by OCR; it may hold reading errors

3 4 2 1 Positioning Command (G01) (Cont'd)

Table 3 18 Servo Parameters

Parameter No Description Unit 40 Max speed speed 4] Accel time ms 42 Position loop gain pulse 44 Servo error deviation pulse

3 4 2 2 Skip Positioning Command (G05, G06, G07)

Skip positioning command is in three types, each designated by G05, G06 and G0?

e- ree eter cooetar

Portas et ere G 05 xX ct reers JL sl ak shed

UCL ere ore er ' « Gok dULdh ah ak ak a han | F. BLadt sheesh a t Feedba

The conditions are similar with G06 and G07

G05, G06, GO? positioning X position in absolute value

(-9999999 to +9999999) U_ position in incremental value

(-9999999 to +9999999) F speed (0 to 60000) I torque hmit (10 to 200%)

With these commands, the slide moves to the position X (or U) in the currently selected coordinate system at speed F and torque limit I (F and I can be omitted, as 1s the case with the positioning command) When a skip signal turns on during the motion, the motion 1s interrupted, and the execution of the next block 15 started

To execute the command of the next block after the motor has reached the target position it 1s necessary to insert the in-position wait command (G04) or wait command (GO04D ) Refer to para 3 4 2 5, In-position Wait Com- mand, and para 3 4 2 6, Wait Command

Command G05 is skipped by a signal 5 (EPSS5), G06 by signal 6 (EPS6), and G07 by signal 7 (EPS7) If no applicable skip signal turns on during the motion towards the position specified by X (U), the motion 1s identical with the one under G01

If an applicable skip signal 1s already on, when a command G05, G06 or G07 1s given, the execution 1s postponed until the skip signal turns off If it 1s not turned off within 2 seconds, the contro] enters the skip signal fault (MP alarm) state

60

1F 114+ 24V 1/0 POWER Pp R iF2) ov | suPPLY (PREPARED BY USER) TT ~ msi 4 CE 15 | epss, : f EXTERNAL POSITION Tot CE 16 | EPS6 _ SKIP SIGNAL 5 ; EXTERNAL POSITION _ CE 17| EpPS7 SKIP SIGNAL 6 1 ; _ j EXTERNAL POSITION CE 471 O24 SKIP SIGNAL 7 48 4g Moronpack . . - Fig 3 62 SPEED 30ms MAX COMMAND ~ ] MOTOR a uec a“ POSITION 4 | . POSITION SHIF 1 I - BY DELAY OF FIEAD IN COMMAND MOTOR, eo TIM = SKIP | SIGNAL

[ cos NexT BLOCK COMMAND

Fig 3 63

With the skip positioning command, the posi- tioning motion can be interrupted by an external signal, and the execution can be shifted ts different blocks

For example, with the HI-CUP motor feed unit shown in Fig 3 62, used in deep hole dritling operations, the skip positioning command 1s useful

In this case, the feed is commanded by a skip positioning command, and the load on the tool 1s so detected that it gives skip positioning signals at certain levels Then, as the tool load reaches these levels, the feedrate 1s switched down to the predetermined optimum level

Page 67 read from a scan by OCR; it may hold reading errors

RAPID TRAVERSE 10 in/haIN

FEED UNIT DRILL

SPEED DF TECIOR

{TACHOMETER GENERATOR)

7 ¥ 1900 tym MAIN

MOTOR t

WORKPIECE

HI CUP MOTOR (sR 1st) 12 kW

“ee

POSITION DETECTOR fOPTICAL TACHOMETER) n= 1000 P/R

LEADSCREW PITCH 10 nimisreyv

© 4 uw > 4 ion boat a w > o

SKIP 6 EPS6

OVERTRAVEL(R) - -D0 HOME POSITION DO DECELERATION

RAPID TRAVERSE

F 10000

F 10000

200 350 Fig 3 65

With the spindle motor current monitored by a proper means, when it exceeds the rated level during feeding at F=350, a skip signal EPS5 1s turned on, and when 1t exceeds the :ated level at F=200, EPS6 is turned on

Program example

N040 G53 T3 041 GO1i X200 F10000 Rapid traverse

042 G05 X350 £350 F=350 drilling feedtate

043 G67 P04? Arrival check “°

044 G06 X350 F200 F=200 drilling feediate select 045 G67 P04? Arrival check Note

046 GOl X350 F100 F=100 drilling feedrate select 047 G04 In-position

048 G53 TO 10 coordinate select

049 G69 P300 Jump to N=300

N300 G27 X0 F10000 Return to home position

30] M30

T3 coordinate select

Note When the slide ariives at X (or U) with the skip positioning command without skipping with the arrival check (G 67) command, it jumps to P (See 3 4 2 9)

Execution of the next block

When the controller detects that the associated skip signal is ON, it stops positioning operation, slows down and stops After the end of distribution of command pulses, it begins to ecrecute the next block Note that the timing of reading the skip signal may delay 30 msec at maximum and therefore the start of deceleration may be delayed accordingly This leads to deviation of the stop position

The case in which the target position 1s reached before the skip signal turns ON is the same as with GOI (refer to par 3 4 21)

Related parameters Refer to par 3 4 2]

3 4 2 3 External Positioning Command (G34)

a et old i ee oo c G 34 Xion Poiana aa Towa, ro oes rte

Ulin a ‘ bok oat b gh sho Jhaa

G34 external positioning

X position in absolute value (-9999999 to +9999999)

U_ position in incremental value

(- 9999999 to +9999999) F speed (0 to 60000)

1 torque lmit (10 to 200%)

With this command, the shde moves to the position X (U) in the currently selected coo-dinate system at speed F, and a torque limit I (F and I can be omitted, as 1s the case with a positioning command }) When an external positioning signal (EXP2) is turned on during the motion, the slide dccelerates and stops at the position where EXP2 is turned on

COMMAND SPEED x --Sf Shy 5 1 .N 1 . NN i MOTOR: \ SO

', e TIME

READIN | position| TIME ‘ > 50 us MAX | , 3» Pa 7 rae POSITION SHIFT

BY DELAY OF READ IN we TIME

Fig 3 66

61

Page 68 read from a scan by OCR; it may hold reading errors

3 4 2 3 External Positioning Command (G34) (Cont'd) External positioning signals are read with response deviation within 50 u sec, so that the feedrate need be less than 20 KPPS

When the slide stops by an external posi- tioning signal, and the position 1s in-position, an external positioning completion signal (G34) 1s output which 1s turned off when a completion check signal (G34F) 1s input

If no EXP 2 turns on until the shlde arrives at the position specified by X (U), and becomes in-position, an external positioning alarm (EPAL) signal is output

When a completion signal (G34F) 1s turned on, the completion signal (G34) or the alarm signal (EPAL) 1s reset If EXP2 or G34F signal is already on when the execution of G34 command 1s started, the execution is postponed until these signals are turned off, and if they are not turned off within 2 seconds, an alarm signal (EPAL) 1s output -

SPEED) COMMAND __ f 1 \ . MOTOR OY \V, - TIME 1 POSITION ' aa 1 7 a COMMAND ,% 7 4 1 MOTOR i] \ |, e TIME EXTERNAL POSITIONING 4 SIGNAL EXP2 | Lo EXTERNAL POSITIONING i COMPLETION SIGNAL G 34 EXTERNAL POSITIONING C COMPLETION CHECK SIGNAL G34 F } -----~- 1, READ IN TIME EXTERNAL POSITIONING H H ' ¢ 30ms MAX ALARM 4 t, EPAL

G34 COMMAND

Fig 3 67

The reset conditions for the external positioning alarm signal (EPAL) are as follows

G34F signal ON

Mode switching over

62

Z NEXT BLOCK tF1 1/0 POWER 1F2{|+24V SUPPLY (PREPARED EY USER) OV +24v CB 49, EXTERNAL POSITIONING CB 50. 24V, _ EXP? CB OT on ] = ht CB10 EXP2 | EXTERNAL POSITIONING St CE 30 COMPLETION CHECK G34F CE 47| G34F ~] mal +24v ag! | CD 7 G34 EXTERNAL POSITIONING cp 8 COMPLETION EPAL EXTERNAL POSITIONING co 1 2y+24v Mationpack _ | Fig 3 68

Since the external positioning function allows the positioning at a position where an external signal (e g , touch switch) is turned on, it can be used for tool setting, etc we TOUCH SWITCH 200 00mm HOME POSITION IS SET AT 600 ON M/C, a

E<) - - COORDINATE tT 300 t M/C COORDINATE 4 iT 4 J 600 400 200 0

HOME POSITION Fig 3 69

In execution of a skip positioning command, the arrival check command (G67) skips after judging whether or not skipping has occurred Therefore, G67 can be placed in the next block of GO5 (or G06 or G07) to branch the program, depending on whether or not skipping has occurred

Page 69 read from a scan by OCR; it may hold reading errors

In Fig 3 69, assume that the tool point is to be set at a position making contact with the touch switch, Since the tool length is 300 mm, the position where the tool tip makes contact with the touch switch 1s approximately 500 mm

N100 G01 X510 F12000 Rapid traverse close to touch switch

101 G34 X490 F300 External positioning at low speed

102 G52 X200 Tl Tool tip setting

Execution of the next block

When the end confirmation signal (G34F) turns ON, the external positioning end signal (G34) or alarm (EPAL) is reset When the Motionpack- 33 controller detects that signal G34F has turned OFF, program advances to the next block The timing of reading the G34F signal may vary

30 msec at maximum

Related parameters Refer to par. 3 421

3 4 2 4 Home Position Check Command (G27)

G27 Xoi; F I : Bb ge seas JLest Jed ho odk gk dk aha bo abo oaks bo sk sb ast shaogteul

G27 Home position check command

X position in absolute value (- 9999999 to +9999999)

Us position in incremental value (-~9999999 to +9999999)

F speed (0 to 60000)

I torque hmit (10 to 200%)

Operation

The origin confirmation signal (G27) checks if the coordinate of the PG origin of programmed operation is correct As described in par

3 3.5 1, Motionpack-33 determines the PG origin from the origin pulse (1 pulse/rev) of PG and origin-related LSs and its coordinates are defined with parameter Pr71

The G27 command determines if the position designated with X(U) is the PG origin currently selected, then moves to the destination at speed F and torque limit I (F and I can be omitted as in the positioning command )

The Motionpack-33 controller distributes command pulses, taking the target position - Pr46 (or +Pr46) as the temporary target position Then, moving in the range of the target position +Pr46, it seeks the origin pulse

Reading the origin pulse, it determines if the coordinate is the same as the PG origin (PG origin - Pr77 £ C-phase pulse § PG origin + Pr77) At the same time, it checks the origin LS signal at the PG origin

If the return-to-origin method uses a waiting position, it must be given G27 error results if 1t 1s not given In the stopper method, G27 cannot be used since the origin pulse is not used

G2? error (MP alarm) results 1f the command position 1s wrong or the slow-down LS signal is erroneous.

When the command position is wrong, G27 error (Err G27) results with no movement made G27 error also results when the coordinate of the PG origin 1s wrong or the origin LS signal is erroneous

DECELERATION f l LSA

DECELERATION LSB

HOME POSITION ae Li _fl JL. , Lb none POSITION PULSE CHECK

™ POSITIONING TO HOME POSITION

MOTION

Tm ALLOWABLE DEFLECTION Pr77

Fig 3 70 Execution of the next block

The coordinate of the PG origin and the origin LS signal on the PG origin are checked and, if everything 1s correct, execution of the next block starts Otherwise, G27 error results with an alarm given and execution of the next block does not start

Related parameters Home position check parameters (Pr70 to Pr77)

and G27 allowable error amount (Pr46) in addition to positioning and servo parameters

3 4 2 5 In-position Delay (G04)

Time delay Go|

When the time delay command G04 1s given without any time specification, the command 1s an in-position delay command Normally, positioning commands G01, G05, G06 and G07 allow the program to proceed to the next block as soon as the command pulses have given out

63

Page 70 read from a scan by OCR; it may hold reading errors

3 4 2 5 In-position Delay (G04) (Cont'd)

When G04 is commanded, the program will not proceed to the next block until the machine arrives at the specified position If the machine fails to arrive at the commanded position within 2 seconds of the G04 command, the system enters the in-position fault (MP alarm) state The per~ missible error for the positioning 15 given In pulses by parameter P45

PROGRAM WILL NOT PROCEED TO THE NEXT BLOCK SPEED UNTIL MACHINE ARRIVES AT THE SPECIFIED POSITION \ COMMAND PROGRAM EXAMPLE N MOTOR 100 GOIxx! . 101 GO4 tot ame TIME 102 GO1Xx2 toy 1} { Pras Pp OSITION], Conmano {, e TIME COMMAND N100 GOI | | 102 G01 EXECUTION N101 G04 Fig 3 71

Execution of next block

As shown in Fig 3 66, execution of the next block starts when the in-position area has been reached by the immediately preceding feed command

Related parameter Pr45

3 4 2 6 Time Delay Command (G04)

co neaes

G04 Dina,

G04 D 0 01 to 600 00

Decimal point position s

Unit 1l0ms

Operation The machine remains motionless for the time specified by D_ In this case, the machine position 1s not checked for in-position

A dwelling program using the time delay command is shown below

64

SPEED DETECTOR RAPID TRAVERSE

10 my MIN ‘TACHOMETER GENERATOR), ) 7 V/1000 rpm MAIN FEED UNIT MOTOR

HI CUP

MOTOR ayRel/lh

12nw

WORKPIFCE i= ij vy ja =) 4 a ea

66 § foerican Tachoweren) | s N= 1000 P/R £33 pee SBE 10 mmsrev 3 26 Pa ue i 5 ok 3 ° DWELL 300 500 Fig 3 72 010 G53 Ti 011 GQ1 X300 F10000 Rapid trave:se 012 G01 xX500 F300 Cutting 013 G04 In-position delay 014 G04 D1 Delay | sec 015 G53 TO 016 G27? X0 F 10000 OL? M30

Execution of the next block starts when the designated with D has elapsed

Related parameters None

3 4 2 7 Coordinate Setting Command (G52)

G52 Kona 2 oa Th, U boat oe a G52 Coordinate setting command

X position in absolute \alue (~9999999 to +9999999)

U_ position in incremental value (-9999999 to +9999999)

T coordinate No 1 to 9

Lime