Manual · Allen-Bradley
Allen-Bradley 1201-HA2 and 1201-HAP Manual
Manual2 pagesPDF 480 KB
Both pages are below, each with its text.
Covers · 2 models
The models it covers
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
A two-page product flyer (publication 1201-1.1, February 1996), not a user manual, on the Series B Human Interface Module (HIM) for SCANport drives and motor controllers. It lists the new Series B features and a table of HIM kits and option cables, including catalog numbers 1201-HAP and 1201-HA2, with outline dimensions.
- What it is
- Series B Human Interface Module (HIM) kit for customer installation p. 1, 2
- Works with
- SCANport products: 1305, 1336 PLUS and 1336 FORCE drives, SMP-3 overload relay, SMC Dialog Plus, 1394 and 1557 p. 1
- Memory
- Stores up to two complete parameter profiles for upload and download p. 1
- Fault queue
- Shows the last four faults in Control Status mode p. 1
- Enclosure designs
- NEMA Type 1 (IP 30) and NEMA Type 12/UL Type 4X (Indoor) (IP 66) p. 1
- Kit types
- Blank, programmer only, programmer/controller with analog pot, and programmer/controller with digital up-down speed control p. 2
- Kit catalog numbers
- 1201-HAB, 1201-HAP, 1201-HA1, 1201-HA2, 1201-HJP, 1201-HJ2 p. 2
- Cradle port cables
- 1202-H03, 1202-H10, 1202-H30, 1202-H90 (one-third, one, three and nine meter lengths) p. 2
- Comm port cables
- 1202-C03, 1202-C10, 1202-C30, 1202-C90 p. 2
- Fault display
- A fault message appears whatever mode is in use p. 1
What this manual walks you through
- New features of the Series B HIM p. 1
- Choosing a HIM kit and option cable p. 2
- Searching a parameter profile for settings changed from factory defaults p. 1
Good to know
- The 1201-HJP and 1201-HJ2 kits need an option cable to work. p. 2
- Option cable kits are for HIMs not mounted on the drive chassis. p. 2
Questions this manual answers
Which drives does the Series B HIM work with?
The flyer says it can be used with all SCANport products, naming the 1305, 1336 PLUS and 1336 FORCE drives, SMP-3, SMC Dialog Plus, 1394 and 1557. p. 1
Can the 1201 HIM copy parameters between drives?
Yes, its resident memory stores up to two complete parameter profiles for upload and download. p. 1
What cable connects a remote HIM to the cradle port?
The 1202-H03, H10, H30 and H90 option cables connect to the HIM cradle port, in one-third, one, three and nine meter lengths. p. 2
How many past faults does the HIM show?
The fault queue shows the last four faults in Control Status mode. p. 1
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
Take Hold of the New Features Available with the Series B Human Interface Module
New Features:
- NEMA Type 12/UL Type 4X (Indoor) construction: Available in both NEMA Type 1 (IP 30) and NEMA Type 12/UL Type 4X (Indoor) (IP 66) designs
- Upload/download capability: Resident memory allows for storage of up to two complete parameter profiles, saving time programming multiple drives
- Search: Allows user to search a parameter profile to determine which features are no longer at factory default values
- Immediate fault display: If a fault occurs, fault message appears regardless of what mode is in use
- Bit ENUM’s: User can scroll through and view a test description of each bit in a binary parameter, without using a look-up table for identification
- Changing digits of parameters and password: Increment or decrement individual parameter digits to save programming time
- Fault queue: View the last four faults in the Control Status mode without going into the Program or Display mode
- Saving menus for power-up: Can be programmed to power up to a variety of process displays (i.e. RPM, Feet-per-minute, etc.)
The Series B HIM can be utilized with all SCANport™ products: 1305 Drive, 1336 PLUS Drive, 1336 FORCE ™ Drive, SMP-3 ™ Overload Relay, SMC ™ Dialog Plus Smart Motor Controller, 1394 Digital Motion Controller and 1557 Medium Voltage Drive.
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
Human Interface Module Kits (For Customer Installation)
Catalog Number (Loose Kit)
DescriptionUsed With…NEMA Type 1 (IP 30)
All Open Chassis and NEMA Type 1 Drive Ratings
Blank-No Functionality Programmer Only Programmer/Controller with Analog Pot Programmer/Controller with Digital Up-Down Speed Control
HIM Cradle Option Cable 1202-H03/H10/H30/H90
NEMA Type 12/UL Type 4X (Indoor) (IP 66)
1201-HAB 1201-HAP 1201-HA1 1201-HA2 All NEMA Type 12 and IP 65 Drive Ratings
Programmer Only Programmer/Controller with Digital Up-Down Speed Control Option Cable Kits
All Human Interface Modules Not Mounted on the Drive Chassis
(Connect to H.I.M. Cradle Port) One/Third Meter Length One Meter Length Three Meter Length Nine Meter Length
1202-H03 1202-H10 1202-H30 1202-H90
(Connect to Communication Port) One/Third Meter Length One Meter Length Three Meter Length Nine Meter Length
1202-C03 1202-C10 1202-C30 1202-C90
Door Mount Bezel Kit, NEMA Type 1
Communications Port(s)
1201-HJP* 1201-HJ2*
Customer Supplied 1201-DMA NEMA Type 1 Enclosures
Option Cable 1202-C03/C10/C30/C90
- Requires an Option Cable to be functional 5.06 (128.5)
.45 (11.4).83 (21.1).20 (5)3.40 (86.4)3.94 (100)157 (4) 12 MAX. (3.0)
.30 (7.5) 3.54 (90) 6.62 (168.1)
5.51 (140)5.09 (129.3) 2.76 (70)1.38 (35.1).56 (14.2)3.94 (100)5.32 (135)2.76 (70)5.51 (140).56 (14.2)
Allen-Bradley, 1336 FORCE, SMP-3, SCANport and SMC are trademarks of the Allen-Bradley Co., Inc.
Allen-Bradley Headquarters, 1201 South Second Street, Milwaukee, WI 53204 USA, Tel: (1) 414 382-2000 Fax: (1) 414 382-4444 Publication 1201-1.1 – February 1996 Supersedes October, 1995
© 1995 Allen-Bradley Co. Printed in USA