Page 361
SLC Communication Channels
13-31
Table 13.10 SLC 5/05 Channel 1 Ethernet Channel Status (Continued) Status field Connections
Port(1)
Words
Displays the number of
Total Message Connections(2)
50
Total existing Ethernet message connections.
Incoming Message Connections(2)
51
Existing incoming Ethernet message connections.
Outgoing Message Connections(2)
52
Existing outgoing Ethernet message connections.
Maximum Connections Allowed(3)
53
Maximum number of connections allowed.
Auto Negotiate Status 54; bit 4 0 = Disabled, 1 = Enabled Port Speed
54; bit 2 0 = 10 Mbps, 1 = 100 Mbps
Port Duplex
54; bit 3 0 = Half-duplex, 1 = Full-duplex
Link States
54; bit 5 0 = Online, 1 = Offline
SNMP Server
54; bit 1 0 = Enabled, 1 = Disabled
HTTP Server
54; bit 0 0 = Enabled, 1 = Disabled
(1)
OS501, Series C, FRN9 and higher.
(2)
OS501, Series C, FRN3 and higher.
(3)
OS501, Series C, FRN5 and higher.
For processors running OS Series C, FRN 6 and higher, clicking the Clear button while monitoring Channel Status of either channel 1 or channel 0 online, will reset all of the channel status diagnostic counters for both channels to zero. Prior to OS Series C, FRN 6 the only channel status diagnostic counters that are reset when the Clear button is clicked are the ones on the channel that the programming terminal is connected to. For example, if your programming terminal is connected online via channel 0 and you are monitoring the Channel Status of channel 1, when you click on the Clear button, only channel 0 diagnostic counters will be reset, not channel 1 diagnostic counters.
Configuration Via BOOTP
BOOTP (bootstrap protocol) is a low-level protocol that TCP/IP nodes use to obtain start-up information. By default, the SLC 5/05 broadcasts BOOTP requests at powerup. The BOOTP Valid parameter remains clear until a BOOTP reply has been received. BOOTP lets you dynamically assign IP Addresses to processors on the Ethernet Link. To use BOOTP, a BOOTP Server must exist on the local Ethernet subnet. The server is a computer that has BOOTP Server software installed and reads a text file containing network information for individual nodes on the network.
Publication 1747-RM001G-EN-P - November 2008
Page 362
13-32
SLC Communication Channels
The host system’s BOOTP configuration file must be updated to service requests from SLC 5/05 processors. The following parameters must be configured. Table 13.11 BOOTP Configuration Parameters Parameter
Description
IP Address
A unique IP Address for the SLC 5/05 processor.
Subnet Mask
Specifies the net and local subnet mask as per the standard on subnetting RFC 950, Internet Standard Subnetting Procedure.
Gateway
Specifies the IP address of a gateway on the same subnet as the SLC 5/05 that provides connections to another IP network.
TIP
You can use any commercially available BOOTP server. If you do not have BOOTP Server capabilities on your network, and you want to dynamically configure Channel 1, you can download the free Rockwell Automation BOOTP server from the Rockwell Automation website. Go to www.ab.com/networks/bootp/index.html
When BOOTP is enabled, the following events occur at power-up. • The processor broadcasts a BOOTP-request message containing its hardware address over the local network or subnet. • The BOOTP server compares the hardware address with the addresses in its look-up table. • The BOOTP server sends a message back to the processor with the IP address and other network information that corresponds to the hardware address it received. With all hardware and IP addresses in one location, you can easily change IP addresses in the BOOTP configuration file if your network needs change. The BOOTP request can be disabled by clearing the BOOTP Enable parameter in the channel Configuration File. When BOOTP Enable is cleared (disabled), the SLC 5/05 uses the existing channel configuration data. IMPORTANT
Publication 1747-RM001G-EN-P - November 2008
If BOOTP is disabled, or no BOOTP server exists on the network, you must use SLC 500 programming software to enter/change the IP address for each processor.
Page 363
SLC Communication Channels
13-33
Using the Rockwell BOOTP Utility The Rockwell BOOTP utility is a standalone program that incorporates the functionality of standard BOOTP software with a user-friendly graphical interface. It is located in the Utils directory on the RSLogix 5000 installation CD. It can also be downloaded from www.ab.com/networks/bootp/index.html web page. The device must have BOOTP enabled (factory default) to use the utility. To configure your device using the BOOTP utility: 1. Run the BOOTP software. In the BOOTP Request History panel you will see the hardware addresses of devices issuing BOOTP requests.
2. Double-click on the hardware address of the device you want to configure. You will see the New Entry pop-up window with the device's Ethernet Address (MAC).
3. Enter the IP Address, Subnet Mask, and Gateway you want to assign to the device, and click on OK. The device will be added to the Relation List, displaying the Ethernet Address (MAC) and corresponding IP Address, Subnet Mask, and Gateway (if applicable). Publication 1747-RM001G-EN-P - November 2008
Page 364
13-34 SLC Communication Channels
Publication 1747-RM001G-EN-P - November 2008 fd BOOTP Server File Tools Help
> BOOTP Request History hr:min:sec] | Ethernet Address (MAC) | IP Address | Subnet Mask
| Gateway 4]
14:20:36 00:00:BC:05:00:67 14:20:33 00:00:BC:06:00:6C 14:20:28 00:00:BC:05:00:67 14:20:26 00:00:BC:06:00:6C 14:20:23 00:00:BC:05:00:67 14:20:21 00:00:BC:06:00:6C 14:20:20 00:00:BC:05:00:67
|
=i
> Relation List
New | Ethemet Address (MAC) | IP Address | Subnet Mask
| Gateway
00:00:BC:05:00:68 130 255, 255.0.0
Delete Enable BOOTP |
Disable a“ | Force IP Renew |
Status “Unable to service BOOTP request from 00:00:BC:05:00:67: No entry in Relation List.
Page 365
SLC Communication Channels
SLC 5/05 Embedded Web Server Capability
13-35
SLC 5/05 processors with OS501, Series C, FRN 6 (or higher) include an enhanced embedded web server (introduced in Series C, FRN 5) which allows viewing of not only module information, TCP/IP configuration, and diagnostic information, but also includes the data table memory map, data table monitor screen, and user-provided web pages via Ethernet using a standard web browser. In order to view the web server main menu from a standard web browser, type: http://www.xxx.yyy.zzz for the web address The www.xxx.yyy.zzz is the IP address of the SLC 5/05 processor. The following topics appear on the main menu. • Module Information • TCP/IP Configuration • Diagnostic Information • Data Table Memory Map • Data Table Monitor • User Provided Pages
Figure 13.1 SLC 5/05 Home Page
Module Information The module information page displays a table with information about the processor. The specific information displayed includes the processor model, series/revision of the processor, mode of the processor and the name of the program in the processor. Also displayed is the revision/build of the Ethernet firmware and the module uptime (time since power was last applied).
Publication 1747-RM001G-EN-P - November 2008
Page 366
13-36
SLC Communication Channels
Figure 13.2 SLC 5/05 Module Information Page
TCP/IP Configuration This page displays a table with information about the current TCP/IP configuration parameters. Included are the module’s IP address, the subnet mask, gateway address, the Ethernet hardware address and whether BOOTP is enabled. Also included are the name server, secondary name server and the default domain name parameters, if configured. Figure 13.3 SLC 5/05 TCP/IP Configuration Page
Publication 1747-RM001G-EN-P - November 2008
Page 367
SLC Communication Channels
13-37
Diagnostic Information This section gives you access to the various diagnostic information screens that are available. It is divided into two sections, the Network Stack Statistics and Application Level Statistics. The Network Stack Statistics detail information about the TCP/IP stack, while the Application Level Statistics are related to the Allen-Bradley Client Server Protocol (CSP) and Common Industrial Protocol (CIP) diagnostics. The individual diagnostic screens automatically refresh using a time which is configurable by the user and defaults to 15 seconds. Figure 13.4 SLC 5/05 Diagnostic Information Main Page
Publication 1747-RM001G-EN-P - November 2008
Page 368
13-38
SLC Communication Channels
Data Table Memory Map The Data Table Memory Map page displays a list of the data table files, their type, and size in elements for a connected SLC 5/05, as shown in the following example. Figure 13.5 Data Table Memory Map Page
Publication 1747-RM001G-EN-P - November 2008
Page 369
SLC Communication Channels
13-39
Each file contains a hyperlink that takes you to the specific Data Table Monitor page for that file. When you click on a particular file, the Data Table Monitor page appears, displaying the contents of the data table file you selected. Figure 13.6 Data Table Monitor Page
The available and default display formats depend on the data type of the file. Press the Prev or Next buttons to display the previous or next page of the data table file, if any. You can change the Data Table Address, Display Format, and Refresh Data Every xx seconds fields by entering data in the text boxes and clicking the Change Parameters button. To change the refresh data function back to the default of 15 seconds, click the Default field. To disable the refresh data function, click the Disable button.
Publication 1747-RM001G-EN-P - November 2008
Page 370
13-40
SLC Communication Channels
Data Table Monitor You may also go directly to the Data Table Monitor screen by selecting it on the home page or by clicking on D/T Monitor on the bottom row of the other pages. In this case, since a particular data file has not been chosen, a default screen is displayed. Figure 13.7 Default Data Table Monitor Screen
From here you may enter in the starting data table address to display.
Publication 1747-RM001G-EN-P - November 2008