Page 461

Messaging Examples

15-15

Passthru Example: DH+ to DF1

For the Step by Step procedure for this example refer to Knowledgebase Document Number: G20024.

Publication 1747-RM001G-EN-P - November 2008

Page 462

15-16

Messaging Examples

Passthru Example: DH-485 to DH+

For the Step by Step procedure for this example refer to Knowledgebase Document Number: G20025.

Publication 1747-RM001G-EN-P - November 2008

Page 463

Messaging Examples

15-17

Passthru Example: DH+ to DH-485

For the Step by Step procedure for this example refer to Knowledgebase Document Number: G20026.

Publication 1747-RM001G-EN-P - November 2008

Page 464

15-18

Messaging Examples

SLC 5/05 Passthru Examples

Passthru Example: DF1 to Ethernet The IP Addresses used in the following illustration are for example purposes only. Contact your system administrator for IP addresses unique to your network. In the following diagram, a SLC 5/03 will send a local message via DF1 to the SLC 5/05 (IP Address 100.100.115.9). The SLC 5/05 acts as a bridge, sending the message out via Ethernet to the SLC 5/05 (IP Address 100.100.115.1), whose address is stored in the routing table.

IMPORTANT

Publication 1747-RM001G-EN-P - November 2008

In the SLC 5/05 (IP Address 100.100.115.9) bridge, Status File Bit S:34/5 must be set to 1 to enable DF1-to-Ethernet passthru.

Page 465

Messaging Examples

15-19

The following is the logic necessary for the SLC5/03 processor.

MSG Instruction The following rung triggers the MSG instruction with a true-to-false transition upon entering into the run mode. Each time the MSG instruction either reaches Error or Done, rung 2:1 unlatches the enable bit, giving the instruction a false-to-true transition the next scan. The MSG instruction sends its command for each false-to-true transition of its rung, provided it is not in the process of sending a message.

MSG Read/Write Message Type Peer-To-Peer Read/Write Read Target Device 500CPU Local/Remote Local Control Block N7:100 Control Block Length 14 Setup Screen

0000

MSG_ERROR_BIT N7:100 0001 12

EN DN ER

MSG_ENABLE_BIT N7:100 U 15

MSG_DONE_BIT N7:100 13 END

0002

The following is the MSG Setup for the SLC5/03 processor.

Publication 1747-RM001G-EN-P - November 2008

Page 466

15-20

Messaging Examples

Local node address is the station address in the SLC 5/05 (IP Address 100.100.115.9) routing table where the target IP address for SLC 5/05 (IP Address 100.100.115.1) is stored.

SLC 5/05 (IP Address 100.100.115.9) Bridge Ladder logic is not required for the SLC 5/05 which acts as the bridge from DF1-to-Ethernet. However, you must set up a passthru routing table when configuring the bridge. The General channel configuration page is shown below, followed by the Channel 1 System configuration page with the Pass Thru Routing Table File entry.

Passthru Link IDs are used by other processors to send remote MSG packets through the SLC 5/05 (IP Address 100.100.115.9) when channel-to-channel passthru is used. Passthru Link IDs must be properly specified in the remote MSG instructions to enable channel-to-channel passthru. The default Passthru Link ID for Channel 0 is one. The default Passthru Link ID for Channel 1 is two.

Publication 1747-RM001G-EN-P - November 2008

Page 467

Messaging Examples

15-21

The Passthru Routing Table File is the integer file used by the processor to store routing table IP addresses and link them to unique node addresses.

IMPORTANT

Channel 0 Source ID must be set to 0 when SLC 5/05 (IP Address 100.100.115.9) is used as the bridge between DF1 full-duplex and Ethernet.

Passthru Routing Table The passthru routing table is located under the channel configuration selection in RSLogix 500 Programming Software. If a Passthru Routing Table File number was entered in the Chan. 1 - System tab in the Channel Configuration dialog box, click on the + in front of Channel Configuration to reveal the routing table selection.

IMPORTANT

The routing table must contain the IP address of SLC 5/05 (IP Address 100.100.115.1) at station target node one, as shown in the routing table above. Target node one was identified as the target node in the SLC 5/03 Message Setup dialog box.

For the Step by Step procedure for this example refer to Knowledgebase Document Number: G20027.

Publication 1747-RM001G-EN-P - November 2008

Page 468

15-22

Messaging Examples

Passthru Example: Ethernet to DF1

For the Step by Step procedure for this example refer to Knowledgebase Document Number: G20028.

Publication 1747-RM001G-EN-P - November 2008

Page 469

Messaging Examples

15-23

Passthru Example: DH-485 to Ethernet

For the Step by Step procedure for this example refer to Knowledgebase Document Number: G20029.

Publication 1747-RM001G-EN-P - November 2008

Page 470

15-24

Messaging Examples

Passthru Example: Ethernet to DH-485

For the Step by Step procedure for this example refer to Knowledgebase Document Number: G20030.

Publication 1747-RM001G-EN-P - November 2008