Page 511

SLC 5/03 (OS30x), SLC 5/04 (OS40x) and SLC 5/05 (OS50x) Firmware History

OS302, Series C, FRN 6 OS401, Series C, FRN 6 OS501, Series C, FRN 6 released: November 2002

A-13

Enhancements • Response support for additional PLC-5 style commands SLC 5/03, 5/04 and 5/05 processors now can receive and respond to the following additional PLC-5 style commands received through channel 0 or channel 1. The Bit Write and Read-Modify-Write commands are used to write one or more bits within a particular word of data in any data table integer or binary file, as well as bits within status file words. The Word Range Read command allows a block of words (up to the maximum supported by the receiving channel) to be read from any data table file. The Word Range Write command allows a block of words to be written (up to the maximum supported by the receiving channel) to any data table file (subject to configured file write protection, if any), except for the I/O image files. For all four commands, the PLC-5 system address may be encoded as either a logical binary address or a logical ASCII address. • Channel diagnostic counter reset command When a diagnostic counter reset command is sent to the processor (RSWho, RSLogix 500 or another application), the diagnostic counters for both channel 0 and channel 1 are reset. Previously, only the counters on the channel where the command was received was reset. • DF1/DH-485 broadcast support Broadcast write commands received through channel 0 can be executed with the previously unsupported channel 0 system mode drivers (DF1 Full-duplex and DF1 Radio Modem). Broadcast write commands can be initiated via the MSG instruction for all channel 0 system mode drivers and for channel 1 (DH-485) on the SLC 5/03 processor. Previously, SLC 5/03, 5/04 and 5/05 processors supported the reception of broadcast write commands via DF1 Half-duplex and DH-485 networks. Broadcast write commands are commands sent to node 255. When a broadcast write command is received without error, the receiver attempts to execute the command, but never returns a reply to the write command. This allows a single command to synchronize all of the devices receiving that command on the local network. This can be used to simultaneously set all of the device clocks on the network or to Publication 1747-RM001G-EN-P - November 2008

Page 512

A-14

SLC 5/03 (OS30x), SLC 5/04 (OS40x) and SLC 5/05 (OS50x) Firmware History coordinate a timed sequence of events among multiple processors on the network. • DF1 radio modem channel 0 driver This driver implements a protocol, optimized for use with radio modem networks, that is a hybrid between DF1 Full-duplex protocol and DF1 Half-duplex protocol, and therefore is not compatible with either of these protocols. Like DF1 Full-duplex protocol, DF1 Radio Modem allows any node to initiate to any other node at any time (if the radio modem network supports full-duplex data port buffering and radio transmission collision avoidance). Like DF1 Half-duplex protocol, a node ignores any packets received that have a destination address other than its own, with the exception of broadcast packets and passthru packets. Unlike either DF1 Full-duplex or DF1 Half-duplex protocols, DF1 Radio Modem protocol does not include ACKs, NAKs, ENQs, or poll packets. Data integrity is ensured by the CRC checksum. • DF1 channel-to-channel passthru Channel 0 DF1-to-Channel 1 passthru on the SLC 5/04 and 5/05 processors can work with the DF1 Half-duplex Master and DF1 Radio Modem drivers, in addition to the DF1 Full-duplex driver. The S:34/5 Status File bit is used to enable DF1 passthru functionality for the channel 0 DF1 Half-duplex Master and DF1 Radio Modem drivers, as well as for the DF1 Full-duplex driver. For the SLC 5/05 processor, a Passthru Routing Table must also exist and be configured before channel-to-channel passthru can occur. • SLC 5/05 embedded web server capability SLC 5/05 processors with OS501, Series C, FRN 6 (or higher) includes the data table memory map, data table monitor screen, and user-provided web pages via Ethernet using a standard web browser. In order to view the web server main menu from a standard web browser, type in http://www.xxx.yyy.zzz for the web address, where www.xxx.yyy.zzz is the IP address of the SLC 5/05 processor.

Publication 1747-RM001G-EN-P - November 2008

Page 513

SLC 5/03 (OS30x), SLC 5/04 (OS40x) and SLC 5/05 (OS50x) Firmware History

OS302, Series C, FRN 7 OS401, Series C, FRN 7 OS501, Series C, FRN 7 released: November 2003

A-15

Enhancements • SLC 5/03 channel-to-channel passthru including the following operations: – Channel 0 DF1 Local to Channel 1 DH-485 Remote – Channel 0 DF1 Local to Channel 1 DH-485 Local – Channel 0 DH-485 Remote to Channel 1 DH-485 Remote – Channel 1 DH-485 Remote to Channel 0 DH-485 Remote • DF1 radio modem driver Additions of Store and Forward and several handshaking protocols to the DF1 Radio Modem driver enhance the flexibility of this driver. Store and Forward operation allows nodes to re-broadcast packets received that are not targeting the listening node. This is an important addition for messaging to out-of-range nodes using in-range nodes as repeaters. Two handshaking protocols were added to support handshaking methods used by many radio modems. The two new handshaking protocols include: – Half-duplex with Continuous Carrier – Half-duplex without Continuous Carrier Half-duplex with Continuous Carrier implies that the state of the carrier input signal DCD is ignored for transmissions. Half-duplex without Continuous Carrier implies that the state of the carrier input signal DCD determines if the SLC processor can transmit or receive. If the DCD is high, then receptions are possible. If DCD is low, then transmissions are possible. • Clearing DF1 communication buffers with ASCII Clear Buffer (ACL) instruction This enhancement provides the ability to clear DF1 communication buffers using the ACL instruction. This enhancement is useful in Master/Slave applications when communication errors result in the slave buffers filling up so that it can no longer respond to the Master, and the Master is not polling the Slave because it is no longer getting any responses. In this situation the Channel 0 Incoming Command Pending bit, S:33/0 will be set.

Publication 1747-RM001G-EN-P - November 2008

Page 514

A-16

SLC 5/03 (OS30x), SLC 5/04 (OS40x) and SLC 5/05 (OS50x) Firmware History

OS302, Series C, FRN 8 OS401, Series C, FRN 8 OS501, Series C, FRN 8 released: May 2004

Enhancements

OS501, Series C, FRN 9 released: November 2004

Enhancements

None

IMPORTANT

Only SLC 5/05 Series C processor hardware can support 100 Mbps Ethernet and increased Ethernet connections. Updating processor hardware Series A and B to OS501, Series C, FRN 9 does not increase either the Ethernet port speed or the number of available Ethernet connections on the processors.

• Enable/Disable HTTP (Web) Server Using RSLogix 500 V6.30 and higher, you can disable the SLC 5/05 HTTP web server functionality from within the Channel 1 Configuration by unchecking the HTTP Server Enable check box shown in Figure A.1. Figure A.1 Channel 1 System Configuration Defaults

SNMP Server Enable HTTP Server Enable

The default (checked HTTP Server Enable box shown in Figure A.1) allows you to connect to the SLC 5/05 using a web browser. Although this parameter can be downloaded to the processor as part of a program download or changed and applied while online with the processor, a processor power cycle is required in order for the change to take affect. • Enable/Disable Simple Network Management Protocol (SNMP) Publication 1747-RM001G-EN-P - November 2008

Page 515

SLC 5/03 (OS30x), SLC 5/04 (OS40x) and SLC 5/05 (OS50x) Firmware History

A-17

Using RSLogix 500 V6.30 and higher, you can disable the SLC 5/05 SNMP functionality from within the Channel 1 Configuration by unchecking the SNMP Server Enable check box shown in Figure A.1. The default (checked SNMP Server Enable box shown in Figure A.1) allows you to connect to the SLC 5/05 using an SNMP client. Although this parameter can be downloaded to the processor as part of a program download or changed and applied while online with the processor, a processor power cycle is required in order for the change to take affect. IMPORTANT

Since SNMP is used as part of the ControlFlash firmware upgrade process, the SNMP server must be enabled prior to beginning the firmware upgrade.

• Selectively Disabling Individual Data Files from Web View Using RSLogix 500 V6.30 and higher, you can disable individual data files from being viewed via any web browser by selecting the data file’s properties page and checking the Web View Disable check box as shown in Figure A.2. Any data file property changes must be made offline and downloaded to the processor. Figure A.2 Web View Disable Check Box

Web View Disable

• More Secure Processor Ownership Behavior Several RSLogix 500 online operations require obtaining the processor Edit Resource/Processor Ownership in order to ensure that one programming terminal has exclusive capability of performing any of these operations at a time. These operations include downloading, online editing, and applying channel configuration changes. An enhancement was made in FRN 9 to ensure this ownership exclusivity via EtherNet/IP, even when multiple programming terminals are routing through a single ControlLogix gateway. With FRN 9, if routing through a ControlLogix gateway or connecting to the same Ethernet

Publication 1747-RM001G-EN-P - November 2008

Page 516

A-18

SLC 5/03 (OS30x), SLC 5/04 (OS40x) and SLC 5/05 (OS50x) Firmware History network as the SLC 5/05 using the RSLinx Ethernet/IP driver (AB_ETHIP-x), the RSLinx CIP Options need to be configured for Messaging as shown in Figure A.3. Figure A.3 RSLinx CIP Options Configuration

In addition to reducing the number of RSLinx Messaging Connections per PLC to one, it is also recommended that the Messaging Connection Retry Interval be increased from the default of 1.25 seconds to 8 seconds as shown in Figure A.3.

Publication 1747-RM001G-EN-P - November 2008

Page 517

SLC 5/03 (OS30x), SLC 5/04 (OS40x) and SLC 5/05 (OS50x) Firmware History

OS302, Series C, FRN 10 OS401, Series C, FRN 10 OS501, Series C, FRN 10 released: January 2006

A-19

Enhancements • Three new explicit message instructions: – CEM (ControlNet Explicit Message) – DEM (DeviceNet Explicit Message) – EEM (EtherNet/IP Explicit Message) – SLC 5/05 only The CEM, DEM and EEM explicit message instructions allow generic Common Industrial Protocol (CIP) commands to be initiated to devices, such as drives, communicating on ControlNet, DeviceNet and EtherNet/IP networks, respectively. All three instructions require RSLogix 500 version 7.10 or higher software for programming. The CEM instruction utilizes the explicit message capability built into the 1747-SCNR ControlNet scanner module, while the DEM instruction utilizes the explicit message capability built into the 1747-SDN DeviceNet scanner module. While not adding any additional capability over what already exists in the scanner modules, the CEM and DEM instructions greatly simplify the programming, configuration, monitoring and troubleshooting of explicit messages on ControlNet and DeviceNet. The EEM instruction provides new explicit message capability for the SLC 5/05 processor on an EtherNet/IP network. This capability is implemented through the processor’s channel one Ethernet port. It shares the same queuing and buffering scheme, as well as Ethernet connection resources, that are used by the Ethernet MSG instruction. • New Read Program Checksum (RPC) instruction The RPC instruction copies the checksum of the processor program from either the processor’s RAM memory or from the installed memory module into the designated destination integer file location. The program checksum is a 16-bit value that is calculated for the entire ladder logic image, excluding data table values. The checksum changes any time program edits are made. Therefore, the RPC instruction can be used within the user ladder logic to determine whether online edits have changed the checksum from a known value or can verify that the program in the memory module matches the program in the processor’s RAM memory. This instruction requires RSLogix 500 version 7.10 or higher software for programming. • Dynamic Host Configuration Protocol (DHCP) capability – SLC 5/05 only

Publication 1747-RM001G-EN-P - November 2008

Page 518

A-20

SLC 5/03 (OS30x), SLC 5/04 (OS40x) and SLC 5/05 (OS50x) Firmware History

DHCP is another option for dynamically configuring the IP address of the SLC 5/05 processor channel 1 Ethernet port (in addition to BOOTP). When the SLC 5/05 is configured for DHCP, it will broadcast a DHCP request at every power-up requesting that an IP address be assigned to it. Any DHCP server that receives the request can respond to it. The main difference between DHCP and BOOTP is that while a BOOTP server will normally assign the same IP address every time to a particular Ethernet device, based on its MAC address, a DHCP server may assign any IP address from a pool of valid addresses. This capability requires RSLogix 500 version 7.10 or higher software for configuring. • Secured processor capability using RSAssetSecurity Using the RSAssetSecurity software service of the FactoryTalk Automation Platform, RSLogix 500 version 7.10 or higher programming software can configure a processor to be “permanently” secured against future unauthorized programming software access. Once secured, only users who have been authenticated and authorized via RSAssetSecurity will be able to go online and upload/download this processor using RSLogix 500 version 7.10 or higher. The only way to unsecure a secured processor is to either disconnect the battery and clear processor memory back to factory default, or to install a memory module with an unsecured program configured to auto-load at power-up. The Secure Processor checkbox is found on the Controller Properties General tab. A new read-only status file bit, S:34/8, reflects the secured status of the processor (0=unsecured, 1=secured).

Publication 1747-RM001G-EN-P - November 2008

Page 519

SLC 5/03 (OS30x), SLC 5/04 (OS40x) and SLC 5/05 (OS50x) Firmware History

OS302, Series C, FRN 11 OS401, Series C, FRN 11 OS501, Series C, FRN 11 released: June 2008

A-21

Enhancements • Modbus RTU Master capability on RS232 Channel 0 Modbus RTU Master capability is added to RS232 Channel 0 communication. Modbus Message commands supported: – 01 Read Coil Status – 02 Read Input Status – 03 Read Holding Registers – 04 Read Input Registers – 05 Force (Write) Single Coil (Latch/Unlatch) – 06 Preset (Write) Single Register – 15 Force (Write) Multiple Coils – 16 Preset (Write) Multiple Registers – "Force" and "Preset" are presented as "Write" • PID Rational Approximation enhancement Added rational approximation method for better calculation accuracy. This bit is disabled by default so as to maintain existing program behavior when upgrading from previous FRN. For the new design, enable Rational Approximation method by setting Word 0, bit 14 to ’1’ in the PID control block.

Publication 1747-RM001G-EN-P - November 2008

Page 520

A-22

SLC 5/03 (OS30x), SLC 5/04 (OS40x) and SLC 5/05 (OS50x) Firmware History

Notes: