Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact

The text of a manual · part 2 of 6

Omega Series Configurable Press Control System User Manual (Cat. No. 6556-SCBK3 and 6556-SCBK3DC), pages 10 to 18

Pages 10 to 18 of 54

The original document is the PDF (241 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Allen-Bradley 1746-HS, Allen-Bradley 1746-IA16, Allen-Bradley 1746-IB8, Allen-Bradley 1746-IB32, Allen-Bradley 1746-IO8, Allen-Bradley 1746-ITB16, Allen-Bradley 1746-IV16, Allen-Bradley 1746-IV32, and 7 more models

Page 10

1–4

Overview

Modes of C/B Operation

An operator can select the mode of clutch/brake operation with a selector switch located on a control panel. In accordance with ANSI B11.1 Section 4.12.4.1, the selection of operating mode must be lockable. This Mode: Off

Lets the Operator: Disable operation of the clutch/brake control when the press is not in operation.

Inch

Jog the press through through successive parts of the cycle by pressing and releasing the pair of run/inch buttons. If the buttons are held, the press will stop at the top of its stroke. Single-stroke Run the press through one complete cycle by holding both run/inch buttons until completion of the down stroke. Continuous Run the press continuously until stopped by a stop-on-top command, or until a fault is detected. To start the press, you press the ARM CONTINUOUS switch and then press the pair of run/inch buttons within five seconds.

C/B Control Functions

Clutch/brake control functions are summarized in the following table.

Control Function:

Operating Mode:

Stop-on-top (cycle stop) Interrupted stroke

Continuous Single or Continuous

Lets the operator stop the press by releasing a run/inch button during downstroke.

Anti-tie-down

All

Prevents the press from starting a new stroke if the control detects that an operator has tied down the run/inch buttons. After run/inch buttons are released, the operator must press both buttons at the same time.

Anti-repeat

Single-stroke or Inch

Limits press operation to a single stroke, even if the operator continues to press both run/inch buttons. The operator must release and press them again to start the next stroke.

Motion detector

Single or Continuous

Brake Monitor

All

Functional Block Diagram

Description: Lets the operator stop the press at top of stroke

Detects press motion from a hardware or software input. Prevents restarting the press when the control detects an over-travel condition.

The functional block diagram in shows the relationships between mechanical components of a stamping press and the C/B control. Run Station 1 pair of buttons for run and inch SLC Processor in Chassis A

SLC Processor in Chassis B Signals to/from Main Solenoid Valves

Stroke Position Input Clutch/Brake Assembly Flywheel

Stroke Position Input Air Supply

Main Solenoid Valves Air to clutch

Resolver to Monitor Stroke Position

Press

Crankshaft

RCLS or Resolver to Monitor Stroke Position

Crankshaft at Top Position Crankshaft at Bottom Position

Publication 6556-6.5.11 August 1998

Page 11

Overview

Resolvers

1–5

The control system requires at least one resolver and resolver input module to precisely monitor the crankshaft’s rotational position for clutch/brake control and PLS operation. We recommend the following, purchased separately:

• resolver: Rockwell Automation 846–SJDN1CG–R3 • resolver input module: Helm HM571–RES

Rotary Cam Limit Switches

You may use a rotary cam limit switche as the redundant input to monitor the crankshaft’s position. We recommend Allen-Bradley Cat. No. 803-P775 that you purchase separately.

Panel Switches and Input Switches

The clutch/brake control requires the panel and input switches listed below. You purchase them separately.

Device

Symbol

Purpose

Type

Allen-Bradley Type

Qty

Lets press operators start the press Assures 2-hand operation Note: Position run/inch buttons at least 24” apart., and the run station in accordance with ANSI B11.1 appendix A.

Momentary pushbuttons dual contact normally closed (N.C.) and normally open (N.O.)

(2) Articulated Palm Buttons 800P-F2CA

1 pair

Stop on Top

Stops press at top during continuous stroking No effect in single mode

Momentary pushbutton single N.C. contact

Yellow Mushroomhead 800T-D9B

1

E-Stop

Stops the press immediately Note: Wire switches in series as needed.

Momentary pushbutton single N.C. contact

Jumbo Mushroomhead 800T-FXP16RA5

1 or more

Mode Select

Lets you select the operating mode: Off Inch Single Continuous

Rotary, 4-position key lockable

800T-N61KF4C

1

Arm Continuous

Lets you begin a timed interval within which to start continuous mode.

Momentary pushbutton single N.O. contact

Black Momentary Pushbutton 800T-A2A

1

Main Motor Forward Interlock

Monitors whether motor-forward starter is engaged. If not, it opens to prevent running the press in single or continuous mode.

N.O. auxiliary contact for forward motor starter

Motor Starter Auxiliary Contact 595-A

2

Air Pressure

Monitors Clutch/Brake air pressure. Note: Switch must be ON to engage the clutch.

N.O. single throw from pressure switch

Pressure Switch 836-C8JX321

1

Motion Detector Interlock

Detects if motion is stopped in single or continuous mode.

N.O. single contact

N/A

2

Control Reset

Lets you manually reset power to valve solenoids at power up or after an E-stop.

Momentary pushbutton single N.O. contact

800T-A2A

1

Clutch/Brake Power Reset

Lets you manually reset clutch power on power up or after E-stop.

Momentary pushbutton triple contact 1 N.O. and 2 N.C.

800T-A2B

1

Palm Buttons for Run Station Left Right

Publication 6556-6.5.11 August 1998

Page 12

1–6

Overview

C/B Outputs

The clutch/brake control has two pairs of outputs from each I/O chassis (chassis A and B) for your clutch/brake valves. The control is designed to operate with valves that have internal fault detection. There are no inputs for valve-stem feedback.

C/B Response Time

The worst case time required for the clutch/brake control to respond to a change of input depends on the sum of these response times: Device:

Delay (ms):

Input Module 1746-IA16 response time

45

Processor scan of C/B code (2k words)

10

Output Module 1746-OX8 switching time

10

Total worst-case response time

65

The number of degrees that the shaft continues to rotate beyond the moment at which the input changes depends on the speed of rotation. The greater the speed (strokes per minute), the further the shaft rotates before a command from the control is applied. We graphed the degrees of shaft rotation vs press speed for a response time of 65 ms. SPM 100 90 80 70 60 50 40 30 20 10 0 0

65 ms

10

20 30 40 Degrees of Shaft Rotation

50

Important: When estimating the braking distance in degrees of rotation, you must add the rotation occurring during system response time to the specified downstroke braking distance. (For example, at 100 SPM, the shaft rotates 39o during a 65 ms system response time plus the braking distance.)

Publication 6556-6.5.11 August 1998

Page 13

Overview

Programmable Limit Switch (PLS)

1–7

The Allen-Bradley Programmable Limit Switch is factory-programmed ladder logic that lets you time or sequence outputs according to precise and repeatable positions of a crankshaft. Crankshaft positions are monitored by a resolver. You can use PLS outputs to integrate auxiliary press machinery such as lifters, grippers blow-off valves, and inter-press automation into your stamping press control system. (See chapter 3 for wiring PLS outputs.)

How a PLS Channel Works Using the PanelView 600 Operator Interface, you preset the rotational position (preset angle) at which you want the PLS output to turn ON. You also select how you want the PLS output to turn OFF: by preset angle or preset time. The output module in chassis A, slot 4 controls the outputs to your application. 0o Near-top Zone Angular preset to turn output ON Down stroke 90o Zone

Up 270o stroke Zone Angular or time preset to turn output OFF Bottom 180o

Then, you can select your application-specific PLS output to trigger:

• part movement between presses in a transfer line • die automation devices such as grippers and lifters • monitoring correct part movement with a DM track function

Die Monitoring (DM)

Allen-Bradley Die/Automation Monitoring is factory-programmed ladder logic designed to let you monitor a variety of conditions synchronized with the rotation of a stamping press crankshaft. The logic is designed to detect the absence, mis-alignment, or unwanted presence of material moving through an automated stamping process. Crankshaft positions are monitored by a resolver. (See chapter 3 for wiring DM inputs.) You enter setups with the PanelView PV600 Operator Interface. The software and associated hardware:

• monitor a variety of logical inputs to detect deviant conditions • set a fault upon detection of a deviant condition You select whether the fault automatically initiates a warning, stop-on-top, stop-now condition, or whether the fault is ignored.

Publication 6556-6.5.11 August 1998

Page 14

1–8

Overview

How a DM Channel Works You select one of several operational modes for a DM input, such as:

• • • • cyclic in-position transfer static As long as the logic detects expected conditions, no action is taken. When the logic detects a deviant condition, it sets a fault. For example, in cyclic mode an input switch is expected to close within a preset zone of rotation that we call a window. Cyclic Mode Transition Diagram a b

Expected Transition Occurs Within Window

Input is NOT ALLOWED When Sensor:

Sensor turns ON then OFF within window a-b

1. stays ON beyond the window

(Pulse-type signal)

Which Results in a Fault SIGNAL Sent After: window goes OFF

2. turns ON outside the window sensor turns ON

3. remains OFF for the cycle next window goes ON

You can use a DM input to monitor:

• an individual station for a part in correct position (in-position mode) • a sequence of stations for the progression of a part (transfer mode) The software provides up to 16 DM selectable input channels. You connect DM inputs to the 1746-ITV input module in chassis A, slot 6.

Tonnage Monitoring

The optional tonnage monitor lets you view either two or four tonnage points upon each closure of the die. The PanelView 600 Operator Interface displays a set of tonnage screens that lets you:

• set up and calibrate tonnage channels • view absolute tonnage and deviation from benchmark tonnage with each closure of the die • set alarms to indicate when detected tonnage exceeds upper or lower limits We recommend the following tonnage monitor, purchased separately:

• tonnage input module: Helm HM604–TSM • tonnage sensors and secondary calibration standard, also from Helm

Publication 6556-6.5.11 August 1998

Page 15

Overview

Related Safety Information

1–9

You are responsible for the safety of the installed press control, and for meeting all applicable laws, codes, and safety requirements. This control deals only with electrical control portions of the C/B mechanism. ATTENTION: The installer of this control must follow ANSI B11.1 regarding mechanical power presses, OSHA 1910.217, and other applicable standards pertaining to safety recommendations related to: machine construction general electrical machine guarding point-of-operation guards, light-curtain gates, 2-hand switches In addition to local codes and laws, you are responsible for the safety recommendations detailed in all applicable codes and standards including:

• OSHA Regulations, Title 29-Labor, Chapter XVII, Section 1910.217, Mechanical Power Presses • ANSI B11.1, American National Standard for Machine Tools, Mechanical Power Presses, Construction, Care, and Use (available from American National Standards Institute 1430 Broadway NY, NY 10018-3363) • NFPA No. 79, Electrical Standard for Metalworking Machine Tools • CAN/CSA-Z142-M90 Code for Punch Press and Brake Press Operation: Health, Safety, and Guarding Requirements (Canadian Standards Assoc. 178 Rexdale Blvd. Rexdale (Toronto) Ontario Canada M9W 1R3) Also refer to Important User Information inside the front cover.

Publication 6556-6.5.11 August 1998

Page 16

1–10

Overview

Specifications for the Clutch/Brake Control

Type of processors

Machine inputs pair of SLC 5/03 processors (preprogrammed, non-programmable)

top stop E-stop run station (1) mode select (rotary switch) clutch/brake air pressure motor forward interlock motion detector interelock arm for continuous on demand control reset C/B power reset

Type of power grounded ac (6556-SCBK3) dc (6556-SCBK3DC)

C/B mode selections off inch single stroke continuous

Valve outputs two clutch/brake valves

Type of valves internal fault detection

Position monitoring inputs at least one resolver input, and one additional resolver, or one additional rotary cam limit switch assembly

Response time 65 ms worst case from switched input to turned-OFF output

Specifications for Programmable Limit Switches and Die Monitoring

Programmable Limit Switches Number of PLS channels 8 Channel input preset range 0-359o Channel output response turn OFF based on choice of 0-359o or time (ms)

Environmental conditions Operating Temperature 0 to 60oC (32 to 140oF) Storage Temperature –40 to 85oC (–40 to 185oF) Relative Humidity 5 to 95% (without condensation)

Designed to comply with ANSI – B11.1 OSHA – 1910.217 CSA – CAN/CSA-Z142-M90 NFPA No. 79

Die Monitoring Number of DM channels Operating Modes

Output responses

Publication 6556-6.5.11 August 1998

16 cyclic in-position transfer static warning stop on top stop now ignore

Page 17

- Use this chapter as an abbreviated procedure for getting setting up the clutch/brake control, PLS and/or DM functions; or as an overview if you need more information.

Procedure for Clutch/Brake Control

1.

Verify That You have All of the Hardware Shipped in the Kit

Hardware Included this manual chapter 1 for -SCBK3 for -SCBK3DC

Hardware That You Provide

1747-L532 1747-AIC 1746-P2 1746-A7 1746-A10 1746-IA16 (ac) 1746-OA16 1746-OX8 700-P400A1

1747-L532 1747-AIC 1746-P2 1746-A7 1746-A10 1746-IB16 (dc) 1746-OB16 1746-OX8 700DC-F310Z24

• Input Switches & Run Station (Application Dependent) • Resolver and resolver input module (minimum of one set) • Rotary Cam Limit Switch assembly (one set if used) • Solenoid Valves (4) with Internal Fault Detection • PanelView 600 Operator Interface (6556-SPV600)

2.

Mount the I/O Chassis publication 1746-5.8

3.

Install the Power Supply publication 1746-5.1

4.

Install the Link Coupler instructions in LC box

5.

Install SLC Processors and I/O Modules for Chassis A and B publication 1747-6.2

• SLC-5/03 • Link Coupler (DH-45) • Power Supply • 7-slot I/O Chassis B • 10-slot I/O chassis A • Input Module • Output Module • Relay Output Module • Relays

(2) (2) (2) (1) (4) (2) (2) (4)

Important: You must identify Processor A (by its label), and install it in the 10-slot chassis A. Installing the wrong processor in chassis A or B will result in a processor fault at power up. Chassis B (7-slot) Slot Chassis A (10-slot) 0

SLC 5/03 Processor A 1747-L532

SLC 5/03 Processor B 1747-L532

1

Input Module 1746-IA16 (ac) or 1746-IB16 (dc)

Input Module 1746-IA16 (ac) or 1746-IB16 (dc)

2

Input Module 1746-IA16 (ac) or 1746-IB16 (dc)

Input Module 1746-IA16 (ac) or 1746-IB16 (dc)

3

Resolver Input Module (required)

Resolver Input Module (optional)

4

Output Module 1746-OA16

Output Module 1746-OB16

5

Isolated Relay Output Module 1746-OX8

6 7 8 9

Input Module for Die Monitor 1746-ITV16 spare optional Tonnage Module Helm HM579-TSM optional Tonnage Module Helm HM579-TSM

Isolated Relay Output Module 1746-OX8 optional I/O Module 1746-NIO4V for: – auto counterbalance – variable-speed press drive – shut-height adjustment

Publication 6556-6.5.11 August 1998

Page 18

2–2

Quick Start

6.

Description: run station, inch/run E-stop mode selection top stop arm continuous E-stop reset C/B power reset main motor forward motion detector air pressure resolvers or resolver & RCLS

7.

Type: palm button rotary, key-lockable push button

N.O. single contact

See chapter 1.

During downstroke, BCAM must be On. During upstroke, TCAM must be On and BCAM must be Off. During upstroke, ACAM must cycle from On to Off to On while TCAM is On. Near top, BCAM and TCAM must be Off while ACAM remains On

C D this manual chapter 1

Set Up (if used) or Simulate Rotary Cam Limit Switches 0o

Set Up or Simulate Rotary Cam Limit Switches as Follows: A B n/a

Install C/B Input Switches and the Resolver (You wire them in step 9.)

Near-top Zone D

A

TCAM ACAM

270o

Up stroke Zone

BCAM

C

Down stroke Zone

90o

Other Conditions: The software is designed to fault if/when it detects: a. ACAM, BCAM, and TCAM are OFF all at the same time. b. BCAM is On when ACAM is Off. B c. ACAM does not cycle while TCAM is On during upstroke. Bottom ACAM should remain On for the entire stroke except for an On/Off/On cycle while TCAM is On during upstroke. 180o Important: See press manufacturer’s recommendations Dual sets of contacts need not cycle at same moment. for on/off settings of ACAM, BCAM, and TCAM switches. An offset of up to 1 second is acceptable.

8.

this manual chapter 3

Connect the Cables

You must make the cable that connects the two link couplers. See the Installation Instructions that accompanied the link coupler for the terminations. The cable uses a pair of 6-pin phoenix connectors. Use this cable: to connect: that you make between link couplers in chassis A and B 1747-C11 Link coupler to the SLC processor

9.

notes: see coupler installation instructions came with the link coupler, two required

Wire the I/O Modules, RCLS, and Input Switches For wiring instructions, refer to chapter 3 and Wiring Drawings (publication 6556-2.15)

Publication 6556-6.5.11 August 1998 chapter 3 and Wiring Dwgs.