Page 19

Quick Start

10.

2–3 chapter 4

Test Clutch/Brake Circuits

ATTENTION: Be sure that all C/B hardware is installed before starting this step.

11.

chapters 5

Test Clutch/Brake Operation

Procedures for Setting Up PLS and DM Channels 1.

Familiarize yourself with PLS and DM operation.

Chapters 1 & 6

2.

If using DM, determine your DM requirements.

Chapter 6

Determine the quantity of DM input channels, their modes, types of input switches, and their locations. We provide worksheet A for your convenience. Wire DM input switches to the 1746-ITV16 input module in chassis A, slot 6.

3.

If using PLS, determine your PLS requirements.

Chapter 6

Determine the quantity of PLS channels, turn-ON presets, and turn-OFF angle or time. We provide worksheet B for your convenience. Wire PLS outputs from the 16-point output module in chassis A, slot 4, pts 8-15.

4.

Use the PanelView 600 Operator Interface to set up system configuration, DM and PLS channels, the resolver, passwords, and variable-speed compensation

Operating Instr. 6556-5.8

Refer to the referenced publication for System, DM, and PLS setup procedures. They include: – System Configuration – Active PLS/DM setups, on line – Recipe PLS/DM setups, offline – System Monitoring

5.

Test DM and PLS channels.

Chapter 7

Use procedures in chapter 7 and screens described in the PanelView 600 Operating Instructions to test: – DM and PLS channels – resolver inputs – transfer-mode channels

Publication 6556-6.5.11 August 1998

Page 20

2–4

Quick Start

Notes:

Publication 6556-6.5.11 August 1998

Page 21

Chapter Objective

In this chapter, we help you install the C/B control with these steps:

• • • • • • • • • • •

If Using the DC Version if using the dc version check hardware mount the I/O chassis install the power supply install the isolated link coupler install SLC processors and I/O modules set up rotary cam limit switches install C/B input switches and resolver(s) connect chassis cables wire your C/B control wiring considerations

1 1 1 1 1 2 3 5 5 6 7

We provide wiring drawings (publication 6556-2.15) for two versions: grounded ac (drawing set 6556503) and dc (drawing set 6556503DC). The dc version has these changes in respect to the ac version:

• replace input module 1746-IA16 with 1746-IB16 in slots 1 and 2 • replace output module 1746-OA16 with 1746-OB16 in slot 4 • replace wiring drawing set 6556503 with 6556503DC

Check Hardware

To check the contents of the kit, refer to Contents of Kit in chapter 1. If items are missing, contact your local salesperson or distributor.

Mount the I/O Chassis

To mount the 7-slot and 10-slot I/O chassis (Cat. No. 1746-A7 and 1746-A10), refer to publication 1746-5.8, SLC 500 Modular Chassis Installation Instructions. Look for this publication in the product box.

Install the Power Supply

To install the power supply (Cat. No. 1746-P2), refer to publication 1746-5.1, SLC 500 Power Supplies Installation Instructions. Look for this publication in the box that contained the power supply. The power supply slides into card guides on the left side of the I/O chassis.

Install the Isolated Link Coupler

To install the link coupler (Cat. No. 1747-AIC), refer to publication Installation Instructions for the SLC500 Isolated Link Coupler shipped with it. Mount the coupler. adjacent to the power supply on the panel holding the I/O chassis. Keep the instruction sheet handy because you will use it to fabricate and connect cables.

Publication 6556-6.5.11 August 1998

Page 22

3–2

Installing and Wiring

Install SLC Processors and I/O Modules

Install the SLC processors and I/O modules in designated slots of each I/O chassis A and B. Important: You must insert the SLC processor labeled “A” into the 10-slot chassis A, and the processor labeled “B” into the 7-slot chassis B. If reversed, the processors will fault at power up.

Self-locking tabs secure the module in the chassis.

Door panel label identifies terminal block connections.

Removable barrier-type terminal block is color coded to the module for quick identification.

Chassis A Slot

Description of Module

Slot

Description of Module

0

Processor A 1747-L532 SLC-5/03

5

Isolated Relay Output Module 1746-OX8

1

Input Module 1746-IA16 (ac) or 1746-IB16 (dc)

6

Input Module 1746-ITV16

2

Input Module 1746-IA16 (ac) or 1746-IB16 (dc)

7

Tonnage Module (optional) Helm HM579-TSM

3

Resolver Input Module (Helm HM571-RES)

8

Tonnage Module (optional) Helm HM579-TSM

4

Output Module 1746-OA16 or 1746-OB16 (dc)

9

Spare

Slot 0 Slot 1 SLC 5/03 IA16

1747-AIC Link Coupler

Publication 6556-6.5.11 August 1998

1746-P2 Power Supply

Slot 2 IA16

Slot 3 Resolver

Resolver Input Module

Slot 4 OA16

Slot 5 OX8

Slot 6 ITV16

Slot 7 Slot 8 Slot 9 Tonnage Tonnage Spare

Spare

Page 23

Installing and Wiring

3–3

Chassis B Slot

Description of Module

Slot

Description of Module

0

Processor B 1747-L532 SLC-5/03

4

Output Module 1746-OA16 or 1746-OB16

1

Input Module 1746-IA16 (ac) or 1746-IB16 (dc)

5

Isolated Relay Output Module 1746-OX8

2

Input Module 1746-IA16 (ac) or 1746-IB16 (dc)

6

I/O Module 1746-NIO4I (optional)

3

Resolver Input Module (optional) Helm HM571-RES

Slot 0 Slot 1 SLC 5/03 IA16

1747-AIC Link Coupler

Set Up Rotary Cam Limit Switches

1746-P2 Power Supply

Slot 2 IA16

Slot 3 Resolver

Slot 4 OA16

Slot 5 OX8

Slot 6 NIO4I

Optional Resolver Input Module

To set up (or simulate with a resolver) rotary cam limit switches, set up the cam angles for each switch assembly as described below and according to the press manufacturer’s installation instructions. Important: Mount these assemblies on opposite ends of the crankshaft so a mismatch (fault) will occur if the crankshaft breaks.

• brake-monitor (BCAM) contacts close at a point that lets the system detect an increase in braking distance • take-over (TCAM) contacts close at bottom to let the press complete a stroke, and open during upstroke to let the press stop at the top • anti-repeat (ACAM) contacts limit press operation to a single stroke in single-stroke mode This Cam:

In this Mode: With these Conditions:

Provides a Signal That:

Anti-Repeat (ACAM)

Inch or Single stroke

Cams open and close in upstroke

Prevents a second stroke in these modes

Take-over (TCAM)

Inch or Single stroke

Cams open in near-top zone

Turns OFF triac outputs for stopping the press at top of stroke (stop-on-top)

Continuous

Cams open in near-top zone after stop-on-top command

Single stroke or Continuous

Cams close near bottom just when (or before) BCAM opens

Lets the press complete a single stroke or run continuously after run buttons are released

When press stops in downstroke beyond BCAM closure

Indicates that braking distance is excessive. Turns OFF solenoid outputs to prevent restart.

Brake-monitor Single Stroke (BCAM) or Continuous

Publication 6556-6.5.11 August 1998

Page 24

3–4

Installing and Wiring

0o

Set Up or Simulate Rotary Cam Limit Switches as Follows: A

During downstroke, BCAM must be On.

B

During upstroke, TCAM must be On and BCAM must be Off.

C

During upstroke, ACAM must cycle from On to Off to On while TCAM is On.

D

Near top, BCAM and TCAM must be Off while ACAM remains On.

Near-top Zone D

A

TCAM ACAM

270o

Up stroke Zone

BCAM Down stroke Zone

C

90o

Other Conditions: The software is designed to fault if/when it detects: a. ACAM, BCAM, and TCAM are OFF all at the same time. b. BCAM is On when ACAM is Off. c. ACAM does not cycle while TCAM is On during upstroke. ACAM should remain On for the entire stroke except for an On/Off/On cycle while TCAM is On during upstroke. The dual sets of contacts need not cycle at the same moment. An offset of up to 1 second is acceptable.

B Bottom 180o Important: See press manufacturer’s recommendations for: * Near-top Zone * Bottom * On/Off settings of ACAM, BCAM, and TCAM switches

As an example, we show typical ON/OFF settings for rotary cam limit switches in the following table where you can write down your initial settings. This RCLS:

Turns ON at a position:

Turns OFF at a position:

Typical ON OFF:

BCAM

• near top, beyond which the software detects a faulty brake

• when overlapped by TCAM in ON position

10o 190o

TCAM

• near bottom • when or before BCAM turns OFF

• that lets the press stop correctly on top • before BCAM turns ON

170o 350o

ACAM

• Remains ON for entire stroke except for an Off span during upstroke (see graph)

Your 1 ON OFF:

290o 250o

1 Important: To determine exact settings, refer to recommendations provided by the press manufacturer.

Set the ACAM off span to the number of degrees (00 - 900) according to the speed of the press (0-200 strokes per minute). 200 180 160 Press Speed (SPM)

140 120 100 80 60 40 20 0 90 0 30 0 60 0 OFF Span of Anti-repeat Contacts During Up Stroke

Publication 6556-6.5.11 August 1998

Page 25

Installing and Wiring

Install C/B Input Switches and Resolver(s)

3–5

Verify that your press has the following switches, required inputs to your clutch/brake control. Refer to chapter 1 for switch specifications. Description:

Type:

run station, inch/run E-stop mode selection top stop arm continuous E-stop reset C/B power reset main motor forward motion detector air pressure position monitor palm button rotary, key-lockable push button

N.O. single contact two resolvers, or one resolver and one RCLS assembly

Follow manufacturer recommendations when installing the resolver(s). Mount position monitors at opposite ends of the crank-shaft axis. If using:

Connect them as follows:

a pair of resolvers resolver input modules in chassis A and B one resolver and one RCLS assembly resolver to chassis A, RCLS assembly to chassis B

Connect Chassis Cables

Connect cables as shown. You must make the cable that connects between the two link couplers. See the Installation Instructions that accompanied the link coupler for the terminations. The cable uses a pair of 6-pin phoenix connectors. Use cable: to connect:

notes:

1747-C11 1747-C20 that you make came with link coupler, 2 required came with PanelView 600 see coupler installation instructions

Link coupler to the SLC processor PanelView 600 to Link Coupler between link couplers in chassis A and B

PS To PanelView 600

1747-C20 1747-C11 cable that you make

Chassis A

Link Cplr PS 1747-C11

Chassis B

Link Cplr

Publication 6556-6.5.11 August 1998

Page 26

3–6

Installing and Wiring

Wire Your C/B Control

We provide wiring drawings (publication 6556-2.15) for the ac (6556503) and dc (6556503DC) versions of this control. Wire your I/O modules and ac or dc power distribution according to those drawings. Inputs and outputs by I/O module and chassis slot are as follows: For

In I/O Chassis

See Sheet

Power distribution n/a

1 of 14

Cabling for Link Coupler and Processor

A and B

4 and 5 of 14

Inputs to 1746-IA16 (1746-IB16) • CRM relay • main motor forward, reverse • C/B mode select • Run/Inch buttons • clutch valve 1 feedback • top stop • arm continuous • fault reset • seal relay • C/B air pressure • main motor start, stop, and reverse (feedback) • ACAM, BCAM, TCAM (chassis B, only if used)

A and B slot 1

6 of 14

Inputs to 1746-IA16 (1746-IB16) for I/O cross-checking • feedback from various relays • feedback from RCLS • heartbeat

A and B slot 2

7 of 14

Helm HM571-RES resolver input module(s) (required for chassis A, optional for chassis B) 1746-OA16 terminals 0-7 for I/O cross-checking • seal relay • BCD mode • ACAM, BCAM, TCAM • clutch output ON • heartbeat 1746-OA16 pts 8-15 for PLS outputs 1746-OA16 pts 8-9 for optional counterbalance outputs slot 3

8 of 14

A and B slot 4

9 of 14

1746-OX8 Outputs • clutch valve outputs and feedback • PLC OK relay and feedback • main motor forward/reverse outputs • indicator outputs

A and B slot 5

10 of 14

1746-ITV16 for DM Inputs 1746-NIO4V optional I/O module for counterbalance pressure, shut height position, and variable-speed drive chassis A, slot 6 chassis B, slot 6

11 of 14

Helm HM604-TSM tonnage module (optional)

chassis A, slots 7, 8 chassis A, slot 9

12 and 13 of 14 14 of 14

Spare chassis A, only chassis B, only

Wire power supplies and other electrical devices according to instructions that accompanied them.

Publication 6556-6.5.11 August 1998

Page 27

Installing and Wiring

Wiring Considerations

3–7

DM Inputs Wire die monitor (DM) inputs to the 1746-ITV16 input module in chassis A, slot 6. This module sources current (the load is a sink). Connect 2-wire or 3-wire input switches as follows: Sourcing (sink load) IN 0

–DC

IN 1

VDC

+DC

PLS Outputs Wire PLS outputs to a 1746-OW16 relay-contact output module in chassis A, slot 4, terminals 8-15 as follows: Relay Output VDC OUT 0

+DC (L1 for ac) CR

OUT 1

Last OUT

–DC (L2 for ac)

I/O for Automatic Counterbalance and Variable-speed Press Drive and Shut-height Adjustment Wire these optional features to the 1746-NIO4V module in chassis B, slot 6. Wire its I/O as shown above. Module characteristics include: # Inputs:

Input Specs:

# Outputs:

Output Range

2

0 to +10 V dc –10 to +10V dc @ –20 to +20 mA @ 16-bit resolution "16,384 counts 60 ms response 10Hz input filter

2

0 to +10V dc 14-bit resolution

Publication 6556-6.5.11 August 1998