Page 28

3–8

Installing and Wiring

Notes:

Publication 6556-6.5.11 August 1998

Page 29

C/B Circuit Testing Chapter Objective

Once you have completed the installation of your clutch/brake control and wired your I/O devices, use this chapter to check circuit wiring. ATTENTION: Before starting this chapter, be sure that: • all clutch/brake control hardware is installed • clutch/brake wiring is complete • the control is in compliance with all applicable standards Otherwise, personal injury or property damage could result.

Testing Circuits and Failure-mode Operation

This section describes the following tests:

• • • • • • • • • •

PLC OK (failure mode) CRM Relay Seal Relay (circuit) Seal Relay (failure mode) Run/inch Buttons Stop-on-top Button Arm Continuous Button Mode Selector Switch Rotary Cam Limit Switches Resolver(s) and Resolver Input Module(s)

1 2 2 3 3 4 4 4 4 4

PLC OK Test (failure mode) This test verifies the correct failure-mode operation of the PLC OK relay for chassis A. You will repeat this procedure for chassis B. 1. With power off, jumper the wired contacts of PLC OK relay (1010CR). 2. Power up. 3. Press the C/B Control Reset button to energize the CRM relay. 4. Press (and momentarily hold) the C/B Power Reset button. 5. Verify that: – the PLC OK relay is NOT energized (red plunger is not recessed) – “PLC OK Check Failed” prompt is displayed on PanelView screen 6. Shut off system power. 7. Remove the jumper. 8. Repeat steps 1-7 for chassis B (PLC OK relay 1033CR).

Publication 6556-6.5.11 August 1998

Page 30

4–2

C/B Circuit Testing

CRM Relay Test (circuit) This test verifies that pressing the E-stop button will de-energize the seal and CRM relays. 1. Power up. 2. Visually and with a voltmeter, verify that: – CRMA relay is not energized – outputs to all press valves are Off. 3. Reset the E-Stop circuit by pressing the Control Reset button. 4. Visually and with a voltmeter, verify that: – CRM relay is energized – outputs to all press valves are Off 5. Reset control power by pressing the C/B Power Reset button. 6. With a voltmeter, verify that power rails to C/B outputs are energized. 7. Press the E-Stop button. 8. Visually and with a voltmeter, verify that seal relay and CRM relay are de-energized.

Seal Relay Test (circuit) This test verifies that when the seal relay is off, press valves are off; and when the seal relay is on, outputs to press valves are energized. 1. Power up (if not already powered up). 2. Reset the E-Stop circuit by pressing the Control Reset button. 3. With a voltmeter, verify that: – seal relay is not energized – outputs to all press valves are Off 4. Reset control power by pressing the C/B Power Reset button. 5. Visually and with a voltmeter, verify that: – seal relay is energized – power rails to C/B outputs are energized 6. Shut off system power.

Publication 6556-6.5.11 August 1998

Page 31

C/B Circuit Testing

4–3

Seal Relay Test (failure mode) This test verifies the correct failure-mode behavior of the seal relay. 1. With power off, place a jumper across the wired contacts of seal relay (1031CR). 2. Power up. 3. Reset the E-Stop circuit by pressing the Control Reset button. 4. Verify that: – the seal relay is NOT energized (red plunger is not recessed) – PLC OK relay is energized (red plunger is recessed) – “Seal Relay Weld Fault” prompt is displayed on PanelView screen 5. Shut off system power and remove the jumper. 6. Restore system power. 7. Reset control power by pressing the C/B Power Reset button. 8. Verify that: – CRM relay is energized (red plunger is recessed) – there is NO fault message 9. Press (and momentarily hold) the C/B Power Reset button. 10.Verify that the seal relay is energized (red plunger is recessed) 11. Shut off system power.

Test Run/Inch Buttons (run station) Test the wiring of Run/Inch buttons by observing LEDs in slots 1 and 2. Check each OK? box after verifying that the LED indication is correct. For This Condition

Slot 1 Input LED Is OFF ON

Right Run/Inch button is pressed

A, Input 5

Left Run/Inch button is pressed

B, Input 5

Both Run/Inch buttons not pressed

OK?

Slot 2 Input LED Is OFF ON B, Input 5 A, Input 5

A & B, Input 5

A & B, Input 5

Publication 6556-6.5.11 August 1998

OK?

Page 32

4–4

C/B Circuit Testing

Test Top Stop and Arm Continuous Buttons Test the wiring of these buttons by observing input LEDs in slot 1. Check each OK? box after verifying that the LED indication is correct. For This Condition

Slot 1 Input LED Is OFF ON

Top Stop not pressed

OK?

A & B, Input 7

Top Stop pressed

A & B, Input 7

Arm Continuous not pressed

A & B, Input 8

Arm Continuous pressed

A & B, Input 8

Test Mode Selector Switch Test the wiring of this switch by observing input LEDs in slot 1. Check each OK? box after verifying that the LED indication is correct. For This Mode-select Position Slot 1 Input LEDs Are OFF

Slot 1 Input LED Is ON OK?

Inch

(input 2)

Single

(input 3)

A & B, only the selected input

Continuous

(input 4)

A & B: Inputs 2, 3, 4 except for the selected input

Test Rotary Cam Limit Switches Test the wiring of the RCLSs by observing input LEDs in slots 1 and 2. Check each OK? box after verifying that the LED indication is correct. For This Condition

Slot 1 Input LED Is OFF ON

ACAM, BCAM, TCAM at rest

OK?

B, Inputs 13, 14 B, Input 15

ACAM, BCAM, TCAM actuated

B, Inputs 13, 14 B, Input 15

Test Resolver(s) and Resolver Input Module(s) Test the wiring of the resolver(s) according to instructions from the manufacturer.

Publication 6556-6.5.11 August 1998

Page 33

Testing C/B Operation Chapter Objective

Once you have checked the wiring of your clutch/brake control, use this chapter to test its operation. Tests include:

• troubleshoot the setup of your RCLS assemblies 1 • tests the operating modes 2 • test the switches 3

Troubleshooting the Setup of Your RCLS Assemblies

We recommend that you test the rotary cam limit switches (RCLS) in Inch mode. The processor monitors RCLS signals to ensure that the motion progresses through the correct sequence of:

• downstroke • upstroke • top zone During each stroke, rotary cam limit switches must cycle through these zones. near bottom Top Zone BCAM

Off

TCAM

Off

ACAM

On

Downstroke

Upstroke

On * On Off * BCAM and TCAM can transition within the same scan or overlap their On states.

Important: The software reads the zones according to the on/off status of ACAM, BCAM, and TCAM switches that you set mechanically. When the software detects any one of the following fault conditions, it is designed to turn outputs off and set the corresponding PanelView messages for detected fault conditions. Use the following look-up table to take corrective action.

Publication 6556-6.5.11 August 1998

Page 34

5–2

Testing C/B Operation

Processor Faults Msg # PanelView Message

Cause of Fault

026*

Illegal RCLS Combination

027*

Forward Transition from Top Forward Transition from Downstroke Forward Transition from Upstroke Forward Shaft Position Transition Faults ACAM Upstroke BCAM Mismatch Between Processors TCAM Mismatch Between Processors ACAM Mismatch Between Processors Cam Mismatch Faults Brake Monitor Fault

Software/hardware cams produced invalid combination. Software/hardware cams did not go from near top to downstroke. Software/hardware cams did not enter upstroke. Software/hardware cams did not enter near top zone. Any of 027-029 detected.

028* 029* 033* 034* 041*

Effect of Fault

How to Correct the Fault

Press will stop or not run in single or continuous mode.

Check software cam logic or hardware cams for proper operation or settings.

ACAM did not cycle in upstroke. One processor sees the BCAM while the other does not. 042* One processor sees the TCAM while the other does not. 043* One processor sees the ACAM while the other does not. 044* Any of 041-043 detected. 046* On a top-stop command, the press Press cannot operate in Check the brake and slid onto BCAM before stopping. single or continuous mode. brake monitor cam settings. * To clear this latched fault bit, you must enable the fault reset bit or turn the mode-select switch to OFF.

Test the Operating Modes

Here are procedures to test dynamic operation of the press in these modes:

• inch • single-stroke • continuous with the arm-continuous method to start this mode Important: If the press control faults or does not operate as expected, read the fault or prompt message and see Appendix B for:

• faults for troubleshooting • prompts for operating the press Inch Mode 1. Place the mode selector switch in inch mode. 2. Power up by pressing the Control Rest and C/B Power Reset buttons. 3. Verify that seal relays and CRM relays are energized. 4. Concurrently, press and hold both run/inch buttons. 5. Observe that the press cycles and stops on top. 6. Release the run/inch buttons and press again for 1-2 seconds. 7. Observe that the press cycles until you release a button, then stops.

Publication 6556-6.5.11 August 1998

Page 35

Testing C/B Operation

5–3

Single-stroke Mode 1. Place the mode selector switch in single-stroke mode. 2. Press and hold run/inch buttons for more than 1/2 stroke. 3. Observe that the press cycles and stops on top. 4. Release run/inch buttons and press again. Then release in downstroke. 5. Observe that the press stops immediately. 6. Bring the press to top by pressing run/inch buttons and release in upstroke. 7. Repeat steps 2 and 3. This time hold run/inch buttons for the entire cycle. 8. Observe that the press runs through one stroke and stops at the top.

Continuous Mode with Arm Continuous 1. Place the mode selector switch in continuous mode. 2. Press the Arm Continuous button. 3. Immediately press run/inch buttons and release after downstroke. 4. Observe that the press continues to cycle. 5. Press the Stop-on-top button. 6. Observe that the press completes the cycle and stops on top. 7. Return to step 2 and press the Arm continuous button. This time, wait for 5 seconds (or until the Arm-continuous timer has timed out) before pressing run/inch buttons. 8. Observe that the press does not start. 9. Repeat steps 2 through 6 for a final verification.

Test the Switches

Test the following switches with an operating clutch/brake control:

• C/B air pressure • motion detector • main motor forward

Publication 6556-6.5.11 August 1998

Page 36

5–4

Testing C/B Operation

C/B Air Pressure Switch 1. Remove the C/B air pressure switch input from chassis A at slot 1 – terminal 12. 2. Place the mode selector switch in single-stroke mode. 3. Attempt to start the press and observe that it does not start. 4. Reconnect the air pressure switch input to chassis A (step 1). 5. Remove the switch input from chassis B (slot 1 – terminal 12) to repeat the test. 6. Attempt to start the press and observe that it does not start. 7. Reconnect the air pressure switch input to chassis B (step 5).

Motion Detector Switch 1. Remove the motion detector switch input from chassis B at slot 2 – terminal 0. 2. Place the mode selector switch in single-stroke mode. 3. Start the press and observe that it stops before reaching bottom. If the press reaches bottom, the circuit is not functioning correctly. 4. Reconnect the motion detector switch input to chassis B.

Main Motor Forward Switch 1. Remove the main motor forward switch input from chassis A at slot 1 – terminal 11. 2. Place the mode selector switch in single-stroke mode. 3. Attempt to start the press and observe that it does not start. 4. Reconnect the main motor forward switch input. 5. Remove the switch input from chassis B (slot 1 – terminal 11) to repeat the test. 6. Repeat steps 3 and 4.

Publication 6556-6.5.11 August 1998