Page 46

7–4

Testing DM and PLS Channels

Notes:

Publication 6556-6.5.11 August 1998

Page 47

Description of Operating Modes Clutch/Brake Operating Modes

You can select any one of the following operating modes with the mode selector switch: • Off • Inch • Single stroke • Continuous stroking

Off When an operator selects OFF, the control system is designed to: • turn off all outputs to press valves. • reset faults

Inch Mode Before entering single or continuous mode, use inch mode to jog the press to the near-top position to set up the machine. The press stops when it moves into the near-top position or when you release a run/inch button (Figure A.1). Figure A.1 Typical Operational Sequence for Inch Mode Select inch mode

No

ATTENTION: To guard against the possibility of personal injury, install a keylock mode select switch so that mode selection can be supervised.

Have you released both Inch buttons? Yes Have you pressed both Inch buttons concurrently?

No

Yes Both processors energize their outputs to actuate the clutch No Has the press moved into the near-top position? Yes

No

Yes Have you released either Inch button? Yes

Both processors de-energize their outputs to stop the press.

ATTENTION: If the press coasted past the near-top position while braking, the brake is faulty and hazardous. Repair it immediately.

12261

Publication 6556-6.5.11 August 1998

Page 48

A–2

Description of Operating Modes

Single Stroke Mode Single stroke mode is designed to stroke the press once, from top to bottom to top, with the concurrent use of the run/inch buttons. Once the press reaches the takeover cam (TCAM), the operator can release the run/inch buttons without stopping the press. It continues to the near-top position. In downstroke, releasing a run/inch button stops the press (Figure A.2). Then, if the press did not enter the upstroke zone (TCAM On), you may resume downstroke by again pressing run/inch buttons. Once the press reaches the takeover cam (TCAM), the press continues automatically through the upstroke (Figure A.3). Figure A.2 Typical Operational Sequence for Downstroke in Single Mode Select single mode No Is the motor running forward? Yes Have you released both Run buttons since the previous stroke? Yes Have you pressed both Run buttons concurrently? Yes Both processors energize their outputs to actuate the clutch for downstroke Is the press into the upstroke zone? Yes Go to R1 (Figure A.3)

No No

No

No Have you released a Run button? Yes Both processors de-energize their outputs to stop the press. Have you released, then pressed both Run buttons concurrently? Yes

Figure A.3 Typical Operational Sequence for Upstroke in Single Mode R1 Upstroke continues regardless of releasing Run buttons Both processors de-energize their outputs to stop the press.

Publication 6556-6.5.11 August 1998

Yes

Has either processor detected a critical fault? No Has the press moved into the near-top position? Yes Both processors de-energize their outputs to stop the press in the near-top position

ATTENTION: If the press coasted past the near-top position while braking, the brake is faulty and hazardous. Repair it immediately.

No

Page 49

Description of Operating Modes

A–3

Continuous Mode with Arm Continuous To run your press continuously, ready the press as follows: • select continuous mode • press the arm continuous button • press both run/inch buttons within 5 seconds During the first downstroke (Figure A.4), releasing a run/inch button stops the press. Then, if the press did not enter the upstroke zone (TCAM still off), you may resume downstroke within 5 seconds if you release and press both run/inch buttons again. If 5 seconds passes and the press stops, you must press the arm continuous button and run/inch buttons again to restart. During the first upstroke (Figure A.4) when TCAMs come on, you may release run/inch buttons and the press will continue stroking. If you start the press in upstroke, you must press the arm continuous button and then hold run/inch buttons for a complete cycle until next upstroke. Once in continuous stroking operation (Figure A.5), the press stops at the next near-top position whenever it receives a stop-on-top command. However, the press stops immediately whenever either processor detects a trip or stop condition or a required condition is removed. Figure A.4 Typical Operational Sequence to Start Continuous Mode R2 Select continuous mode Yes Is the motor running forward? Yes Have you released the Topstop button?

NOTE: Releasing a Run button during first downstroke stops the press. If the slide has not entered the upstroke zone, you can resume downstroke within 5 seconds of pressing the Arm Continuous button. After 5 seconds (and the press is stopped), you must restart continuous mode with the arming sequence.

Yes Have you released both Run buttons? Yes Have you pressed the Arm Continuous button? Yes Have you pressed both Run buttons? Yes Both processors energized their outputs Has the press reached the upstroke zone? Yes Go to R3 (Figure A.5)

No No

No

No

No

No

No Has the Arm Continuous timer timed out?

Yes

No Have you released a Run button, or has a stop condition occurred? Yes Both processors de-energize their outputs to stop the press.

Publication 6556-6.5.11 August 1998

Page 50

A–4

Description of Operating Modes

Figure A.5 Typical Operational Sequence for Continuous Stroking R3 Both processors allow continuous stroking regardless of releasing Run buttons. Have you pressed a Top-stop button? No Has the PLC received a Top-stop command? No No

Publication 6556-6.5.11 August 1998

Yes

Yes

Has a stop condition been detected?

The stroke continues until the press reaches the top. Is the press in the near-top position?

Yes Both processors de-energize outputs to stop the press.

Yes Both processors de-energize their outputs to stop the press in the near-top position.

NOTE: The press strokes continuously until you press a Stop-on-top button, the SLC processor receives a stop-on-top command, or a stop condition is detected.

ATTENTION: If the press coasted past the near-top position while braking, the brake is faulty and hazardous. Repair it immediately.

No

Page 51

A, B

L, M, N abbreviations, P-2 license, software, 1-1 audience, P-1 link coupler (1747-AIC), 1-3, 3-1 cable fabrication, W. D. sheet 4

BCAM, 3-3, 3-4 block diagrams, 1-2, 1-4

C cables installation, 3-5 link coupler, W.D. sheet 4 C/B control system control functions. 1-4 installation, 3-5 modes of operation, 1-4 outputs, 1-6 overview, 1-2 response time, 1-6 testing circuits, 4-1 testing operation, 5-1 clutch, part-revolution, friction, 1-2 connections, to I/O modules, 3-2, 3-6, 3-7 continuous mode (C/B), 1-4, A-3 modes of operation C/B, 1-4, A-1 DM, 6-1

O outputs (C/B), 1-6 overview of C/B control, 1-1

P, Q panel switches, 1-5 PLS (programmable limit switch), 1-7 setting up, 6-1, 6-5 testing, 7-3 wiring, 3-7 processors, SLC 5/04 (1747-L532), 1-3 publications, related, P-1 quickstart, 2-1 counterbalance, I/O for, 3-7

R

D, E resolvers, 1-5, 3-3, 7-3 dc version of controller, 3-1 DM (die monitor), 1-7 modes, 6-2 setting up, 6-1 testing, 7-1 wiring, 3-7

F, G, H failure-mode operation (C/B test), 4-1, 4-3

I, J, K inch mode (C/B), 1-4, A-1 input switches, list of, 1-5 installation (C/B), 3-2, 3-5 cables, 3-5 link coupler, 3-5, W. D. sheet 4 rotary cam limit switches, 3-3, 3-4 I/O chassis, 3-2, 3-3 I/O wiring considerations, 3-7 slot locations, 3-2 response time, of C/B control, 1-6 rotary cam limit switches (803-P775), 1-5 setting up and testing, 3-4, 3-5, 5-1

S safety information, 1-9 shut height adjustment, I/O for, 3-7 single-stroke mode (C/B), 1-4, A-2 specifications (C/B, DM, PLS), 1-10 switches, list of panel and input, 1-5

T, U, V terms (and abbreviations), P-2, 1-4 testing C/B circuits and failure modes, 4-1, 4-3 C/B operating modes & switches, 5-1, 5-3 DM and PLS channels, 7-1, 7-3 RCLS operation, 5-1 resolver operation, 7-3 transfer-mode DM, 6-2, 7-2 variable-speed drive, I/O for, 3-7 kit, contents of, 1-1

W–Z wiring, 3-1, 3-6, 3-7, (W. D. pub 6556-2.15) Publication 6556-6.5.11 August 1998

Page 52

I–2

Index

Notes:

Publication 6556-6.5.11 August 1998

Page 53

I–1

Publication 6556-6.5.11 August 1998

Page 54

Allen-Bradley, a Rockwell Automation Business, has been helping its customers improve productivity and quality for more than 90 years. We design, manufacture and support a broad range of automation products worldwide. They include logic processors, power and motion control devices, operator interfaces, sensors and a variety of software. Rockwell is one of the world’s leading technology companies.

Worldwide representation. Argentina • Australia • Austria • Bahrain • Belgium • Brazil • Bulgaria • Canada • Chile • China, PRC • Colombia • Costa Rica • Croatia • Cyprus • Czech Republic • Denmark • Ecuador • Egypt • El Salvador • Finland • France • Germany • Greece • Guatemala • Honduras • Hong Kong • Hungary • Iceland • India • Indonesia • Ireland • Israel • Italy • Jamaica • Japan • Jordan • Korea • Kuwait • Lebanon • Malaysia • Mexico • Netherlands • New Zealand • Norway • Pakistan • Peru • Philippines • Poland • Portugal • Puerto Rico • Qatar • Romania • Russia–CIS • Saudi Arabia • Singapore • Slovakia • Slovenia • South Africa, Republic • Spain • Sweden • Switzerland • Taiwan • Thailand • Turkey • United Arab Emirates • United Kingdom • United States • Uruguay • Venezuela • Yugoslavia

Allen-Bradley Headquarters, 1201 South Second Street, Milwaukee, WI 53204 USA, Tel: (1) 414 382-2000 Fax: (1) 414 382-4444

Publication 6556-6.5.11 August 1998

PN955133-08 Copyright 1998 Allen-Bradley August Company,1998 Inc. Printed in USA Publication 6556-6.5.11