Page 31

Discrete Input and Output Modules

31

1746-OB32 5–50V dc TRANSISTOR OUTPUT SOURCING

Wire Group 1

+VDC 1

CONNECTED INTERNALLY

Wire Group 2 VDC 1

VDC 2

VDC 1

VDC 2

OUT0

CR

CONNECTED INTERNALLY

OUT16 0

OUT1 CR

1 2 3 4

4 OUT21

5 OUT6

5 OUT22

6 OUT7

6 OUT23

7 OUT8

7 OUT24

10 OUT9

CR

11 12

CR

12 OUT27

13 OUT12

CR

13 OUT28

14 OUT13

14 OUT29

15 OUT14

15 OUT30

16 OUT15

16 OUT31

17 COMMONS CONNECTED INTERNALLY

CR

11 OUT26

OUT11 CR

CR

10 OUT25

OUT10

CR

CR

3 OUT20

OUT5

Connector Key

CR

2 OUT19

OUT4

CR

CR

1 OUT18

OUT3 CR

CR

0 OUT17

OUT2

CR

+VDC 2

17

COM 1

COM 2

COM 1

COM 2

COMMONS CONNECTED INTERNALLY

DC Com1

DC Com2 SLC PLC

Important:

Each group has separate VDC and DC COM connections. The 1746 32-point modules include a keyed 40-pin female connector and crimp-type pins for connection to I/O wiring. In addition, 1492 prewired cables and interface modules can be used for connecting external I/O. (See pages 8 and 47.)

Publication 1746-2.35

Page 32

32

Discrete Input and Output Modules

High Current Sourcing DC Output Modules (1746-OBP8, -OBP16).C Catalog Number Specification

➀ 1746-OBP8 (RTB)

1746-OBP16 (RTB)

Voltage Category

24V dc

Operating Voltage

20.4 to 26.4V dc source

Number of Outputs

8

16

4

16

0.135A 0.0A

0.250A 0.0A

Signal Delay (max.) (Resistive Load)

on = 1.0 ms / off = 2.0 ms on = 0.1 ms / off = 1 ms

➂ Off-State Leakage (max.)

1 mA

Load Current (min.)

1 mA

Points per Common 5V 24V

Backplane Current Draw

Continuous Current (max.)

Per Point

2.0A at 60°C

Per Module

8.0A at 0° to 60°C 1V at 2A

1.5A at 30°C 1.0A at 60°C 6.4A at 0° to 60°C 1V at 2A

Per Point Per Module

4A for 10 ms 32A for 10 ms

4A for 10 ms 32A for 10 ms

On-State Voltage Drop (max.) Surge Current

➃ (max.)

➀➁

➀ The 1746-OBP8, Series B and later, and 1746-OBP16 provide fast turn-off delay for inductive loads. Fast off delay for inductive loads is accomplished with surge suppressors on this module. A suppressor at the load is not needed unless another contact is connected in series. If this is the case, a 1N4004 diode should be reverse wired across the load. This defeats the fast turn-off feature. Comparative turn-off delay times for 1746-OB8/-OV8 and 1746-OB16E, Series B and later/-OBP8, Series B and later/-OBP16/-OVP16, when switching Bulletin 100-B110 (24W sealed) contactor, are: 1746-OB8/-OV8 off delay = 152 ms; 1746-OB16E, Series B and later/-OBP8, Series B and later/-OBP16/-OVP16 off delay = 47 ms.

➁ A fused common and blown fuse LED are provided on this module. For replacement fuse, use catalog number 1746-F8 or Littlefuse 322010. Refer to page 9 for additional information.

➂ To limit the effects of leakage current, a loading resistor can be connected in parallel with your load. For 24V dc operation use a 5.6k ohm, 1/2W resistor. ➃ Repeatability is once every 1 second at 30 °C. Repeatability is once every 2 seconds at 60°C. RTB = Removable Terminal Block.

Operating Voltage Range

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ 0V dc

20.4V dc

26.4V dc

Operation Not Guaranteed

(Voltage is applied between +VDC and DC common.)

Publication 1746-2.35

Recommended Operating Range

Page 33

Discrete Input and Output Modules

33

Circuit and Wiring Diagrams VDC

1746-OBP8 20.4–26.4V dc TRANSISTOR OUTPUT-SOURCING

6.19K

+DC

VDC1

S

8.87K

OUT 0

G

CR

OUT 1

CR

OUT 3

OUT 2

OUT X

D

20.4–26.4 V dc

DC COM1

NC NC NC

–DC NC NC S

NC +DC

G

VDC2 OUT 4

OUT Y

D

20.4–26.4 V dc

CR

OUT 5

CR

OUT 7

OUT 6 DC COM2

–DC

COM

VDC 6.19K

1746-OBP16

S G

20.4–26.4V dc TRANSISTOR OUTPUT-SOURCING

OUT

D

8.87K

+DC

VDC

OUT 0 0

OUT 1 1

OUT 2

3

OUT 4

5

OUT 6

7

OUT 8

2

OUT 3 CR 20.4–26.4V dc

CR

6

OUT 7 OUT 9

6.19K

4

OUT 5

10 11 OUT 10

CR 12

OUT 11

S

13 OUT 12

G D

CR

OUT

14

OUT 13 15

OUT 14 16

OUT 15

8.87K

CR

CR

CR CR

17 DC COM

–DC SLC PLC

FLASH

Publication 1746-2.35

Page 34

34

Discrete Input and Output Modules

Sinking DC Output Modules (1746-OV8, -OV16, -OV32) Catalog Number Specification

1746-OV16 (RTB)

1746-OV8

1746-OV32

Voltage Category

24V dc

Operating Voltage

10 to 50V dc sink

Number of Outputs

8

16

32

Points per Common

8

16

16

0.135A 0.0A

0.270A 0.0A

0.452A 0.0A

1A at 30°C / 0.5A at 60°C

0.5A at 30°C / 0.25A at 60°C

0.1A at 60°C

8A at 30°C / 4A at 60°C 1.2V at 1A

8A at 30°C / 4A at 60°C 1.2V at 0.5A

3.2A at 60°C 1.2V at 0.1A

3A for 10 ms

3A for 10 ms

1A for 10 ms

5V 24V

Backplane Current Draw

5 to 50V dc sink

Signal Delay (max.) (Resistive Load)

on = 0.1 ms / off = 1 ms

➁ Off-State Leakage (max.)

1 mA

Load Current (min.)

1 mA

➂ Per Point

Continuous Current

Per Module

(max.) On-State Voltage Drop (max.)

➃ (max.)

Surge Current Per Point

➀

➀ The 32-point output modules are fused to protect external wiring, one fuse per common. These fuses are non-replaceable and are rated at 2.5A. ➁ To limit the effects of leakage current, a loading resistor can be connected in parallel with your load. For 24V dc operation use a 5.6k ohm, 1/2W resistor. ➂ Recommended surge suppression for switching 24V dc inductive loads is a 1N4004 diode that is reverse wired across the load. See page 7 for more information on surge suppression.

➃ Repeatability is once every 1 second at 30°C. Repeatability is once every 2 seconds at 60 °C. RTB = Removable Terminal Block.

Operating Voltage Range 0V dc

10V dc

ÉÉÉÉÉÉÉÉ ÉÉÉÉÉÉÉÉ 0V dc

5V dc

Operation Not Guaranteed

(Voltage is applied between +VDC and DC common.)

Publication 1746-2.35

OV8, OV16

50V dc

OV32

50V dc

Recommended Operating Range

Page 35

Discrete Input and Output Modules

35

Circuit Diagrams VDC

VDC

OUT OUT

1746-OV8, OV16 0.39µF OUT

1K

1746-OV32

DC COM OUT

COM

0.39µF 1K

Wiring Diagrams 1746-OV16

1746-OV8

10–50V dc TRANSISTOR OUTPUT-SINKING

10–50V dc TRANSISTOR OUTPUT-SINKING VDC

+DC VDC

+DC

OUT 0

OUT 0

OUT 1

OUT 1

OUT 3 CR

OUT 2 10–50V dc

OUT 3 10–50V dc OUT 4

CR

OUT 5

CR

OUT 6 OUT 7 DC COM

0 1

OUT 2

3

OUT 4

5

OUT 6

7

OUT 8

2 4

OUT 5

6

OUT 7 CR

CR 10

OUT 9 11 OUT 10

12

OUT 11 13

OUT 12

15

OUT 14

14

OUT 13 CR

CR

CR

CR –DC

–DC

OUT 15 17

16

CR CR CR

DC COM SLC PLC

Publication 1746-2.35

Page 36

36

Discrete Input and Output Modules

1746-OV32 5–50V dc TRANSISTOR OUTPUT SINKING Wire Group 1

Wire Group 2

+VDC 1

VDC 1

CONNECTED INTERNALLY VDC 1

VDC 2

OUT0 CR

OUT16 0

OUT1

CR

1

CR

2 3 4

4 OUT21

5 OUT6

5 OUT22

6 OUT7

6 OUT23

7 OUT8

7 OUT24

10 OUT9 11 12

CR

12 OUT27

13 OUT12

CR

13 OUT28

14 OUT13

14 OUT29

15 OUT14

15 OUT30

16 OUT15

16 OUT31

17 COMMONS CONNECTED INTERNALLY

CR

11 OUT26

OUT11

CR

CR

10 OUT25

OUT10

CR

CR

3 OUT20

OUT5

CR

CR

2 OUT19

OUT4

Connector Key

CR

1 OUT18

OUT3

CR

CR

0 OUT17

OUT2

CR

+VDC 2

VDC 2

CONNECTED INTERNALLY

17

COM 1

COM 2

COM 1

COM 2

COMMONS CONNECTED INTERNALLY

DC Com2

DC Com1 SLC PLC

Important:

Each group has separate VDC and DC COM connections. The 1746 32-point modules include a keyed 40-pin female connector and crimp-type pins for connection to I/O wiring. In addition, 1492 prewired cables and interface modules can be used for connecting external I/O. (See pages 8 and 47.)

Publication 1746-2.35

Page 37

Discrete Input and Output Modules

37

High Current Sinking DC Output Module (1746-OVP16) Catalog Number Specification

1746-OVP16

Voltage Category

24V dc

Operating Voltage

20.4 to 26.4V dc sink

Number of Outputs

16

Points per Common

16 5V 24V

Backplane Current Draw

0.25A 0.0A

Signal Delay (max.) (Resistive Load)

on = 0.1 ms / off = 1 ms

➂ Off-State Leakage (max.)

1 mA

Load Current (min.)

1 mA

Continuous Current (max.)

Per Point Per Module

1.5A at 30°C / 1A at 60°C 6.4A at 0°C to 60°C 1V at 1A

Per Point Per Module

4A for 10 ms 32A for 10 ms

On-State Voltage Drop (max.) Surge Current

➀➁ (RTB)

➃ (max.)

➀ A fused common and blown fuse LED are provided on this module. ➁ The 1746-OVP16 provides fast turn-off delay for inductive loads. Fast off delay for inductive loads is accomplished with surge suppressors on this module. A suppressor at the load is not needed unless another contact is connected in series. If this is the case, a 1N4004 diode should be reverse wired across the load. This defeats the fast turn-off feature. Comparative turn-off delay times for 1746-OB8/-OV8 and 1746-OB16E, Series B and later/-OBP8, Series B and later/-OBP16/-OVP16, when switching Bulletin 100-B110 (24W sealed) contactor, are: 1746-OB8/-OV8 off delay = 152 ms; 1746-OB16E, Series B and later/-OBP8, Series B and later/-OBP16/-OVP16 off delay = 47 ms.

➂ To limit the effects of leakage current, a loading resistor can be connected in parallel with your load. For 24V dc operation use a 5.6k ohm, 1/2W resistor. ➃ Repeatability is once every 1 second at 30°C. Repeatability is once every 2 seconds at 60°C. RTB = Removable Terminal Block.

Operating Voltage Range

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ 0V dc

20.4V dc

26.4V dc

Operation Not Guaranteed

Recommended Operating Range

(Voltage is applied between +VDC and DC common.)

Circuit and Wiring Diagrams 1746-OVP16

VDC

20.4–26.4V dc TRANSISTOR OUTPUT-SINKING +DC VDC OUT 0

8.87K OUT D

G

6.19K

0

OUT 1 1

OUT 2

3

OUT 4

5

OUT 6

7

OUT 8

2

OUT 3 S CR 20.4–26.4V dc

4

OUT 5 OUT 7

CR

6 CR 10

OUT 9 11 OUT 10

12

OUT 11 13

OUT 12

15

OUT 14

14

OUT 13 CR

8.87K D

G

OUT

CR –DC

6.19K

S

OUT 15 17

16

CR CR CR

DC COM SLC PLC

DC COM

Publication 1746-2.35

Page 38

38

Discrete Input and Output Modules

Sinking TTL Output Module (1746-OG16) Catalog Number

Specification

1746-OG16 (RTB)

Voltage Category

➀ 5V dc TTL

Operating Voltage Range

4.5 to 5.5V dc 50 mV peak-to-peak ripple maximum 495 MA maximum at 5V dc

Number of Outputs

16

Points per Common

16 5V 24V

Backplane Current Draw

0.180A 0.0A

Signal Delay (max.) (Resistive Load)

on = 0.25 ms / off = 0.5 ms

Off-State Leakage (max.)

0.1 mA

Load Current (min.)

0.15 mA

Continuous Current (max.)

24 mA

➀ TTL outputs are inverted (0–0.4V dc = low voltage = True = On). Use a NOT instruction in your ladder program to convert to traditional True = High logic. RTB = Removable Terminal Block. NA = not applicable.

On/Off-State Voltage Range (Measure voltage from common terminal to output terminal.)

+ OUT

0V dc

ÉÉÉÉÉÉÉÉÉÉÉÉÉÉ ÉÉÉÉÉÉÉÉÉÉÉÉÉÉ

4.5V dc

0.4V dc

On-state

–

5.5V dc Off-state

Operation Not Guaranteed

TTL inputs are inverted (0–0.4V dc = low voltage = True = On).

COM

Circuit and Wiring Diagrams +5DC

1746-OG16 TTL OUTPUT (Low = True)

74AC14 +DC VDC

OUT

L

OUT 0 L

OUT 1

L

OUT 3

0 1 OUT 2

+5V dc

L

OUT 5

L

OUT 7

L

OUT 9

L

OUT 11

L

OUT 13

74AC14 OUT

L –DC

L 2

3

OUT 4

L 4

5

OUT 6

7

OUT 8

L 6 L 10

11 OUT 10 12 13 OUT 12 14 15 OUT 14

OUT 15

16

L L L

17 DC COM SLC PLC

DC COM

Publication 1746-2.35

Page 39

Discrete Input and Output Modules

39

AC/DC Input Module (1746-IN16) Catalog Number Specification

1746-IN16 (RTB)

Voltage Category

24V ac/dc

Operating Voltage

10 to 30V dc sink 10 to 30V ac at 47 to 63 Hz

Number of Inputs

16

Points per Common Backplane Current Draw

16 5V 24V

0.085A 0.0A

Signal Delay (max.)

dc – on = 15 ms / off = 15 ms ac – on = 25 ms / off = 25 ms

Off-State Voltage (max.)

3V dc 3V ac

Off-State Current (max.)

1 mA dc 1 mA ac

Nominal Input Current

8 mA at 24V dc 8 mA at 24V ac

Inrush Current (max.)

0.02A (ac only)

RTB = Removable Terminal Block.

On/Off-State Voltage Range 0V ac 0V dc

+

Off

IN

ÉÉÉÉÉÉ ÉÉÉÉÉÉ

3V ac 3V dc

10V ac 10V dc

30V ac 30V dc On-state

Input State Not Guaranteed

– COM (Measure voltage from common terminal to input terminal.)

Circuit and Wiring Diagrams 1746-IN16 24V ac/dc SINKING AC/DC COM

L1 or +DC

1µF IN

270

IN 0

261

0

IN 1

2

IN 3

4

IN 5

1

IN 2

1870

3

IN 4

V ac/dc

5

IN 6

6 IN 7 7

IN 8 10 IN 9

11

IN 10 12 IN 11

13

IN 12 14 IN 13

1µF IN

270

1870

15

IN 14

261 L2 or –DC COMMONS CONNECTED INTERNALLY

16 IN 15 AC/DC COM

17 AC/DC COM SLC PLC

Publication 1746-2.35

Page 40

40

Discrete Input and Output Modules

AC/DC Relay Output Modules (1746-OW4, -OW8, -OW16, -OX8) Catalog Number Specification

1746-OW4

1746-OW16 (RTB)

1746-OW8

1746-OX8 (RTB)

Voltage Category ac/dc Relay

Operating Voltage

5 to 265V ac at 47 to 63 Hz / 5 to 125V dc

Number of Outputs

4

8

16

8

Points per Common

4

4

8

Individually Isolated

0.045A 0.045A

0.085A 0.090A

0.170A 0.180A

0.085A 0.090A

5V 24V

Backplane Current Draw Signal Delay (max.) (Resistive Load)

on = 10 ms / off = 10 ms

Off-State Leakage (max.)

0 mA

Load Current (min.)

10 mA at 5V dc

➀ Continuous Current per Point (max.)

Refer to the Relay Contact Ratings tables shown below.

Continuous Current per Module (max.)

8.0A ac

16.0A ac

16.0A ac

Current per Common (max.)

8.0A

8.0A

8.0A

➁

Relay Contact Ratings for 1746-OW4, OW8, and OW16 Amperes

➀ ac

Make

Break

240V ac

7.5A

0.75A

120V ac

15A

1.5A

➁ Continuous

Make

Break

2.5A

1800 VA

180 VA

➂

1.0A

➂

2.0A

125V dc

0.22A

24V dc

1.2A dc

Volt-Amperes

Amperes

Maximum Volts

28 VA

Relay Contact Ratings for 1746-OX8 Amperes

➀

Amperes

Maximum Volts ac

Make

Break

240V ac

15A

1.5A

120V ac

30A

3.0A

5.0A

➂

1.0A

➂

2.0A

125V dc

0.22A

24V dc

1.2A dc

Continuous

Volt-Amperes

➁ Make

Break

3600 VA

360 VA

28 VA

➀ Connecting surge suppressors across your external load will extend the life of SLC 500 relay contacts. For recommended surge suppressors when switching ac inductive loads, consult the SLC 500 Modular Hardware Style Installation and Operation User Manual (Publication 1747-6.2) or the SLC 500 Fixed Hardware Style Installation and Operation User Manual (Publication 1747-6.21). Recommended surge suppression for switching 24V dc inductive loads is a 1N4004 diode reverse wired across the load.

➁ The continuous current per module must be limited so the module power does not exceed 1440 VA. ➂ For dc voltage applications, the make/break ampere rating for relay contacts can be determined by dividing the 28 VA by the applied dc voltage. For example, 28 VA/48V dc = 0.58A. For dc voltage applications less than 14V, the make/break ratings for relay contacts cannot exceed 2A. RTB = Removable Terminal Block.

Publication 1746-2.35