Page 1

ControlLogix Sequence of Events Module 1756-IB16ISOE (24/48V dc), 1756-IH16ISOE (125V dc)

User Manual

Page 2

Important User Information

Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (Publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://www.ab.com/manuals/gi) describes some important differences between solid state equipment and hard-wired electromechanical devices. Because of this difference, and also because of the wide variety of uses for solid state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc. is prohibited. Throughout this manual we may use notes to make you aware of safety considerations. WARNING

IMPORTANT

ATTENTION

Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss.

Identifies information that is critical for successful application and understanding of the product. Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you: • identify a hazard • avoid a hazard • recognize the consequence

SHOCK HAZARD

Labels may be located on or inside equipment to alert people that dangerous voltage may be present.

BURN HAZARD

Labels may be located on or inside equipment to alert people that surfaces may be dangerous temperatures.

Page 3

Preface

Purpose of This Manual

This manual describes how to use the ControlLogix Sequence of Events module in your ControlLogix application. With this manual, you can learn how to install, configure and troubleshoot the module. There are two types of ControlLogix Sequence of Events modules, as described in Table Preface.1: Table Preface.1 Catalog number:

Description:

1756-IB16ISOE

16-point, 10 - 50V dc module June 2004

1756-IH16ISOE

16-point, 90 - 140V dc module

IMPORTANT

Who Should Use This Manual

Availability date: April 2004

The two types of Sequence of Events modules have identical functionality, except for the fact that they operate at different voltage levels. Throughout this manual, we use the term Sequence of Events module generically. When you read the term, it refers to both types of modules unless specifically noted.

This manual is intended for individuals who program ControlLogix control systems, such as: • software engineers • control engineers • application engineers To most efficiently use the Sequence of Events module, you should be familiar with: • ControlLogix™ controllers • ControlLogix ControlNet™ communication modules • RSLogix 5000™ • RSNetWorx for ControlNet™

1

Publication 1756-UM528A-EN-P - April 2004

Page 4

Preface

2

What This Manual Contains Table Preface.2 lists the sections contained in this manual: Table Preface.2

Related Documentation

Section:

Title:

Chapter 1

What is the ControlLogix Sequence of Events Module?

Chapter 2

How Does the Sequence of Events Module Operate in a ControlLogix System?

Chapter 3

Installing the Sequence of Events Module

Chapter 4

Configuring the Sequence of Events Module

Chapter 5

Using the Sequence of Events Module Features

Chapter 6

Using The Sequence of Events Module in CST Per Point Mode

Chapter 7

Using The Sequence of Events Module in FIFO Mode

Chapter 8

Troubleshooting the Sequence of Events Module

Appendix A

Specifications and Module Block Diagrams

Appendix B

Integrating The HiProm GPS Module (1756HP-GPS) into a ControlLogix Sequence of Events Module System

Appendix C

Using the Sequence of Events Module for Absolute First Fault Detection

Appendix D

Using Module Tags

Appendix E

Using Sample RSLogix 5000 Projects with the Sequence of Events Module

Table Preface.3 lists related ControlLogix documentation that may assist you when using the Sequence of Events module. Table Preface.3 Related Documentation

Publication 1756-UM528A-EN-P - April 2004

Catalog number:

Document title:

Publication number:

1756-A4, -A7, -A10, -A13, -A17

ControlLogix Chassis–Series B Installation Instructions

1756-IN080

1756-PA72/B, -PB72/B

ControlLogix Power Supply Installation Instructions

1756-5.67

1756-PA75, -PB75

ControlLogix Power Supply Installation Instructions

1756-5.78

1756-PH75

ControlLogix 125V DC (90-143V) Power Supply

1756-IN589

1756-Series

ControlLogix Module Installation Instructions (Each module has separate installation document.)

Multiple 1756-IN numbers

1756-CNB, -CNBR

Using ControlNet Communication Modules in Logix5000 Control Systems User Manual

CNET-UM001

1756-Lx

ControlLogix System User Manual

1756-UM001

Page 5

Preface

Preventing Electrostatic Discharge

3

This module is sensitive to electrostatic discharge.

ATTENTION

This equipment is sensitive to electrostatic discharge, which can cause internal damage and affect normal operation. Follow these guidelines when you handle this equipment: • Touch a grounded object to discharge potential static. • Wear an approved grounding wriststrap. • Do not touch connectors or pins on component boards. • Do not touch circuit components inside the equipment. • If available, use a static-safe workstation. When not in use, store the equipment in appropriate static-safe packaging.

Publication 1756-UM528A-EN-P - April 2004

Page 6

Preface

4

Environment and Enclosure ATTENTION

This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in IEC publication 60664-1), at altitudes up to 2000 meters without derating. This equipment is considered Group 1, Class A industrial equipment according to IEC/CISPR Publication 11. Without appropriate precautions, there may be potential difficulties ensuring electromagnetic compatibility in other environments due to conducted as well as radiated disturbance. This equipment is supplied as “open type” equipment. It must be mounted within an enclosure that is suitably designed for those specific environmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility to live parts. The interior of the enclosure must be accessible only by the use of a tool. Subsequent sections of this publication may contain additional information regarding specific enclosure type ratings that are required to comply with certain product safety certifications. See NEMA Standards publication 250 and IEC publication 60529, as applicable, for explanations of the degrees of protection provided by different types of enclosure. Also, see the appropriate sections in this publication, as well as the Allen-Bradley publication 1770-4.1 (“Industrial Automation Wiring and Grounding Guidelines”), for additional installation requirements pertaining to this equipment.

Publication 1756-UM528A-EN-P - April 2004