Page 121

Axis properties

Appendix A

Node with a Kinetix 6000 drive

If using the auxiliary feedback port of a Kinetix 6000 drive as a feedback-only axis, the drive must have firmware revision 1.80 or later.

When a Kinetix 6000 drive is designated in the Associated Module box, there is an additional option for the Node value. The option is the node associated with the drive plus 128 with (Auxiliary) after the number. The range is 129 to 234. When the Auxiliary Node assignment is chosen, the axis configuration is changed to Feedback Only on the General tab and an asterisk (*) appears next to General. This also places an asterisk (*) on the Aux Feedback tab. Select that tab and choose values. On the Drive/Motor tab, the Loop Configuration changes to Aux Feedback Only.

General tab - AXIS_VIRTUAL This image is an example of the General tab for an AXIS_VIRTUAL Data Type.

Motion Group

Select the Motion Group to which the axis is associated. An axis assigned to a Motion Group appears in the Motion Groups folder of the Controller Organizer. Selecting ‘none’ terminates the Motion Group association, and moves the axis to the Ungrouped Axes folder in the Controller Organizer. Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

121

Page 122

Appendix A

Axis properties

MOTION_GROUP structure

One MOTION_GROUP data type per controller. This structure contains status and configuration information about the motion group.

Enumerations

Data Type

Description

GroupStatus

DINT

The status bits for the group.

MotionFault

ServoFault

GroupFault

AxisFault

DINT

DINT

DINT

DINT

Bit

Number

Data Type

Description

InhibitStatus

00

DINT

Inhibit status.

GroupSynced

01

DINT

Synchronization status.

AxisInhibitStatus

02

DINT

-no-tag

02

DINT

Timer Event started.

Reserved

03…31

The motion fault bits for the group. Bit

Number

Data Type

Description

ACAsyncConnFault

00

DINT

Asynchronous connection fault.

ACSyncConnFault

01

DINT

Synchronous connection fault.

Reserved

02…31

The servo-module fault bits for the group. Bit

Number

Data Type

Description

POtrvlFault

00

DINT

Positive overtravel fault.

NOtrvlFault

01

DINT

Negative overtravel fault.

PosErrorFault

02

DINT

Position error fault.

EncCHALossFault

03

DINT

Encoder channel A loss fault.

EncCHBLossFault

04

DINT

Encoder channel B loss fault.

EncCHZLossFault

05

DINT

Encoder channel Z loss fault.

EncNsFault

06

DINT

Encoder noise fault.

DriveFault

07

DINT

Drive fault.

Reserved

08…31

Bit

Number

Data Type

Description

SyncConnFault

00

DINT

Synchronous connection fault.

HardFault

01

DINT

Servo hardware fault.

Reserved

02…31

The fault bits for the group. Bit

Number

Data Type

Description

GroupOverlapFault

00

DINT

Group task overlap fault.

CSTLossFault

01

DINT

The controller has lost synchronization with the CST master.

GroupTaskLoadingFault

02

DINT

The group base update period is too low, user application tasks are not getting enough time to execute.

Reserved

03…31 Data Type

Description

The fault bits for the axis. Bit

122

Number

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

Page 123

Axis properties

Enumerations

Appendix A

Data Type

Description PhysicalAxisFault

00

DINT

A Servo or Drive fault occurred.

ModuleFault

01

DINT

A serious fault occurred with the motion module associated with the selected axis. Usually affects all axes associated with the motion module.

ConfigFault

02

DINT

One or more axis attributes associated with a motion module or drive was not successfully updated to match the value of the corresponding attribute of the local controller.

Reserved

03…31

General tab – AXIS_GENERIC

This example shows the General tab for an AXIS_GENERIC data type.

Item

Description

Axis Configuration

Selects and displays the intended use of the axis. Feedback Only

If the axis is used only to display position information from the feedback interface. This selection minimizes the display of axis properties tabs and parameters. The Dynamics tab is not available.

Servo

If the axis is used for full servo operation. This selection maximizes the display of axis properties tabs and parameters.

Motion Group

Selects and displays the Motion Group to which the axis is associated. An axis assigned to a Motion Group appears in the Motion Groups folder of the Controller Organizer, under the selected Motion Group sub-folder. Selecting <none> terminates the Motion Group association, and moves the axis to the Ungrouped Axes sub-folder of the Motion Groups branch.

Module

Selects and displays the name of the motion module to which the axis is associated. Displays <none> if the axis is not associated with any motion module.

Channel

Selects and displays the motion module channel, 0 or 1, to which the axis is assigned. Disabled when the axis is not associated with any motion module.

Motion Planner tab

Use the Motion Planner tab options to: •

Set and edit the number of Output Cam Execution Targets and the Program Stop Action

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

123

Page 124

Appendix A

Axis properties

•

Select and clear the Master Delay Compensation and Enable Master Position Filter

•

Set the bandwidth for Master Position Filter Bandwidth

The Motion Planner tab has the same fields regardless of the type of axis.

124

Item

Description

Output Cam Execution Targets

Determines how many Output Cam execution nodes (instances) to create for an axis. The Execution Target parameter for the MAOC/MDOC instructions specifies which of the configured execution nodes the instruction affects. In addition, the number specified in the Axis Properties dialog box specifies the number of instances of Output Cam in which the value of zero means ‘none’. The value specified for Execution Target in the MAOC instruction references an instance in which a value of zero selects the first instance.

Program Stop Action

Selects how an axis is stopped when the processor undergoes a mode change, or when an explicit Motion Group Programmed Stop (MGPS) instruction is executed. Apply Program Stop Action when an MSG is programmed to Stop type. Fast Disable

The axis is decelerated to a stop using the current configured value for maximum deceleration. Servo action is maintained until the axis motion has stopped, at which time the axis is turned off (that is, Drive Enable is disabled, and Servo Action is disabled).

Fast Shutdown

The axis is decelerated to a stop using the current configured value for maximum deceleration. Once the axis motion has stopped, the axis is placed in the shutdown state (that is, Drive Enable is disabled, Servo Action is disabled, and the OK contact is opened). To recover from this state, execute a Shutdown reset instruction.

Fast Stop

The axis is decelerated to a stop using the current configured value for maximum deceleration. Servo action is maintained after the axis motion has stopped. This mode is useful for gravity or loaded systems, where servo control is needed at all times.

Hard Disable

The axis is immediately disabled (that is, Drive Enable is disabled, Servo Action is disabled, but the OK contact is left closed). Unless the drive is configured to provide some form of dynamic breaking, this results in the axis coasting to a stop.

Hard Shutdown

The axis is immediately placed in the shutdown state. Unless the drive is configured to provide some form of dynamic breaking, this results in the axis coasting to a stop. To recover from this state, a Shutdown reset instruction must be executed.

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

Page 125

Axis properties

Appendix A

Item

Description

Master Delay Compensation

Enables or disables Master Delay Compensation. The default setting is Disabled. Select to enable Master Delay Compensation. Master Delay Compensation balances the delay time between reading the master axis command position and applying the associated slave command position to the slave’s servo loop. It ensures that the slave axis command position accurately tracks the actual position of the master axis; that is, zero tracking error. If the axis is configured for Feedback only, disable Master Delay Compensation.

Enable Master Position Filter

Enables or disables the Master Position Filter. The default is disabled. Select to enable position filtering. Master Position Filter effectively filters the specified master axis position input to the slave axis’s gearing or position camming operation. The filter smooths out the actual position signal from the master axis, and thus smooths out the corresponding motion of the slave axis. When this feature is enabled the Master Position Filter Bandwidth field is enabled.

Master Position Filter Bandwidth

Enabled when Enable Master Position Filter is selected. This field controls the bandwidth for master position filtering. Enter a value in Hz to set the bandwidth for the Master Position Filter. Important: A value of zero for Master Position Filter Bandwidth effectively disables the master position filtering.

The Units tab is the same for all axis data types. Use this tab to determine the units to define the motion axis.

Units tab

Item

Description

Position Units

User-defined engineering units (rather than feedback counts) used for labeling all motion-related values, for example, position and velocity. These position units can differ for each axis. Choose position units for maximum ease of use in the application. For example, linear axes might use position units of Inches, Meters, or mm whereas rotary axes might use units of Revs or Degrees.

Average Velocity Timebase

Specifies the time (in seconds) used for calculating the average velocity of the axis. This value is computed by taking the total distance the axis travels in the amount of time specified and dividing this value by the timebase. The average velocity timebase value should be large enough to filter out the small changes in velocity that result in a noisy velocity value, but small enough to track significant changes in axis velocity. A value of 0.25 to 0.50 seconds works well for most applications.

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

125

Page 126

Appendix A

Axis properties

Servo tab - AXIS_SERVO

This image is an example of the Servo tab for AXIS_SERVO.

Item

Description

External Drive Configuration

Select the drive type for the servo loop: • Velocity - Disables the servo module’s internal digital velocity loop. • Torque - The servo module’s internal digital velocity loop is active, which is the required configuration for interfacing the servo axis to a torque loop drive. • Hydraulic - Enables hydraulic servo application features.

Loop Configuration

Select the configuration of the servo loop. For this release, only Position Servo is available.

Enable Drive Fault Input

Select to enable the Drive Fault Input. When active, the motion module receives notice whenever the external drive detects a fault.

Drive Fault Input

Specifies the usual state of the drive fault input when a fault is detected on the drive. • Normally Open – When a drive fault is detected, it opens its drive fault output contacts. • Normally Closed – When a drive fault is detected, it closes its drive fault output contacts.

126

Enable Direct Drive Ramp Control

Select to set the Direct Drive Ramp Rate in volts per second when a Direct Drive On (MDO) instruction is executed.

Direct Drive Ramp Rate

The Direct Drive Ramp Rate is a slew rate for changing the output voltage when an MDO instruction is executed. A Direct Drive Ramp Rate of 0 disables the output rate limiter, letting the Direct Drive On voltage be applied directly.

Attribute 1/Attribute 2

Select up to two axis attributes whose statuses are transmitted with, for example, the actual position data to the Logix processor. Access the values of the selected attributes through the standard GSV or Get Attribute List service. Can also access the values using template data. The servo status data is updated each base update period. If a GSV is done to one of these servo status attributes without having selected this attribute through the Drive Info Select attribute, the attribute value is static and does not reflect the true value in the servo module.

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

Page 127

Axis properties

Appendix A

Feedback tab – AXIS_SERVO Use the Feedback tab to select the type of Feedback used with the Servo axis.

Item

Description

Feedback Type

Select the Feedback type for the current configuration. The options depend on the motion module to which the axis is associated. A Quadrature B Encoder Interface (AQB)

The 1756-M02AE servo module provides interface hardware to support incremental quadrature encoders equipped with standard 5-Volt differential encoder-interface signals. The AQB option has no associated attributes to configure.

Synchronous Serial Interface (SSI)

The 1756-M02AS servo module provides an interface to transducers with Synchronous Serial Interface (SSI) outputs. SSI outputs use standard 5V differential signals (RS422) to transmit information from the transducer to the controller. The signals consist of a Clock generated by the controller and Data generated by the transducer.

Linear Displacement Transducer (LDT)

The 1756-HYD02 Servo module provides an interface to the Linear Magnetostrictive Displacement Transducer, or LDT. A Field Programmable Gate Array (FPGA) is used to implement a multi-channel LDT Interface. Each channel is functionally equivalent and is capable of interfacing to an LDT device with a maximum count of 240,000. The LDT interface has transducer failure detection and digital filtering to reduce electrical noise.

Item

Description

Feedback Type

Feedback Type is set to SSI - Synchronous Serial Interface.

Code Type

The type of code, Binary or Gray, used to report SSI output. If the module’s setting does not match the feedback device, the positions jump around erratically as the axis moves.

Data Length

The length of output data in a specified number of bits between 8 and 31. The data length for the selected feedback device is found in its specifications.

Clock Frequency

Sets the clock frequency of the SSI device to 208 (default) or 625 kHz. When the higher clock frequency is used, the data from the feedback device is more recent, but the length of the cable to the transducer must be shorter than with the lower frequency.

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

127

Page 128

Appendix A

128

Axis properties

Item

Description

Enable Absolute Feedback

The default is enabled (checked). If Enable Absolute Feedback is set, the servo module adds the Absolute Feedback Offset to the current position of the feedback device to establish the absolute machine reference position. Absolute feedback devices retain their position reference even through a power-cycle; therefore, the machine reference system can be restored at powerup.

Absolute Feedback Offset

If Absolute feedback is enabled, this field becomes active. Enter the amount of offset, in position units, to add to the current position of the Feedback device. The SSI is an absolute feedback device. To establish a value for the Offset, execute the MAH instruction with the Home Mode set to Absolute. When executed, the module computes the Absolute Feedback Offset as the difference between the configured value for Home Position and the current absolute feedback position of the axis. The computed Absolute Feedback Offset is immediately applied to the axis upon completion of the MAH instruction. The actual position of the axis is rereferenced during execution of the MAH instruction; therefore, the servo loop must not be active. If the servo loop is active, the MAH instruction generates an error. When the Enable Absolute Feedback is disabled, the servo module ignores the Absolute Feedback Offset and treats the feedback device as an incremental position transducer. A homing or redefine position operation is required to establish the absolute machine reference position. The Absolute Home Mode is invalid. If using single-turn or multi-turn Absolute SSI Feedback transducers, see the Homing tab information for important details concerning Absolute feedback transducer’s marker reference.

Item

Description

Feedback Type

Feedback Type is set to LDT - Linear Displacement Transducer.

LDT Type

Selects the type of LDT to use to provide feedback to the Hydraulic module. The available types are PWM, Start/Stop Rising, or Start/Stop Falling.

Recirculations

Use this field to set the number of repetitions to use to acquire a measurement from an LDT.

Calibration Constant

Number engraved on the LDT by the manufacturer. The number specifies the characteristics of the individual LDT. Each LDT has its own calibration constant; therefore, changing the LDT also requires changing the Calibration constant.

Length

Defines the stroke of travel of the hydraulic cylinder. The length value is used with the number of recirculations to determine the minimum servo update period.

Scaling

Defines the relationship between the LDT unit of measure (length field) and the unit of measure defined at the Units tab.

Enable Absolute Feedback

Active only when Feedback Type is LDT.

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

Page 129

Axis properties

Appendix A

Item

Description

Absolute Feedback Offset

Enter the amount of offset, in position units, to add to the current position of the LDT. The LDT is an absolute feedback device. To establish a value for the Offset, execute the MAH instruction with the Home Mode set to Absolute. When executed, the module computes the Absolute Feedback Offset as the difference between the configured value for Home Position and the current absolute feedback position of the axis. The computed Absolute Feedback Offset is immediately applied to the axis upon completion of the MAH instruction. The actual position of the axis is re-referenced during execution of the MAH instruction; therefore, the servo loop must not be active. If the servo loop is active, the MAH instruction generates an error. When the Enable Absolute Feedback is disabled, the servo module ignores the Absolute Feedback Offset and treats the feedback device as an incremental position transducer. A homing or redefine position operation is required to establish the absolute machine reference position. The Absolute Home Mode is invalid.

Calculated Values

Conversion Constant

The Conversion Constant is calculated from the values entered on the Feedback screen when selecting Calculate. This calculated value must be typed into the Conversion Constant field on the Conversion tab because the value is not automatically updated.

Minimum The Minimum Servo Update period is calculated based on the values entered for Recirculations and Length Servo Update on the Feedback tab. When these values are changed, clicking Calculate recalculates the Minimum Servo Period Update Period based on the new values. Calculate Button

Drive/Motor tab AXIS_SERVO_DRIVE

Calculate becomes active whenever making changes to the values on the Feedback tab. Selecting Calculate recalculates the Conversion Constant and Minimum Servo Update Period values. Re-enter the Conversion Constant value at the Conversion tab because the values are not updated automatically.

Use the Drive/Motor tab to configure the servo loop for an AXIS_SERVO_DRIVE axis, and open the Change Catalog dialog box.

Item

Description

Amplifier Catalog Number

Select the catalog number of the amplifier to which this axis is connected.

Motor Catalog Number

Select the catalog number of the motor associated with this axis. When changing a Motor Catalog Number, the controller recalculates the values.

Change Catalog

Opens the Change Catalog Number dialog box to select a new motor catalog number.

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

129

Page 130

Appendix A

Axis properties

Loop Configuration

Select the configuration of the servo loop. • Motor Feedback Only – Displayed when Axis Configuration is Feedback only • Aux Feedback Only – Displayed when Axis Configuration is Feedback only • Position Servo • Aux Position Servo (not applicable to Ultra3000 drives) • Dual Position Servo • Dual Command Servo • Aux Dual Command Servo • Velocity Servo • Torque Servo • Dual Command/Feedback Servo

Drive Resolution

Type the number of counts per motor revolution. This value applies to all position data. Valid values range from 1 to 2^32 - 1. One Least Significant Bit (LSB) for position data equals 360° / RotationalPositionResolution. The Drive Resolution is also referred to as Rotational Position Resolution. When saving an edited Conversion Constant or a Drive Resolution value, a message box opens, asking if the controller should automatically recalculate certain attribute settings. Drive Resolution is especially helpful for fractional unwind applications or multi-turn applications requiring cyclic compensation. Modify the Drive Resolution value so that dividing it by the Unwind Value yields a whole integer value. The higher the Drive Resolution setting, the finer the resolution.

Drive Counts per

Choose the units to use for this drive. Options are Motor Inch, Motor Millimeter, and Motor Rev (default).

Calculate

Opens the Calculate Position Parameters dialog box to calculate Drive Resolution and Conversion Constant values based on specific Position Unit Scaling and Position Range information.

Drive Enable Input Checking

Select to enable Drive Enable Input Checking. When enabled, the drive regularly monitors the state of the Drive Enable Input. This dedicated input enables the drive's power structure and servo loop. If cleared, no checking of the Drive Enable Input occurs.

Drive Enable Input Fault

Select to activate the Drive Enable Input Fault. When active, a fault detected on the external drive notifies the motion module via Drive Fault Input.

Real Time Axis Information Attribute 1/Attribute 2

Select up to two axis attributes whose statuses are transmitted – along with the actual position data – to the Logix processor. Access the values of the selected attributes using a GSV command or from the axis tag itself. This data is transmitted at a rate equal to the servo status data update time. If issuing a GSV command for servo status attribute, or using the value from the axis tag, without selecting this attribute via the Drive Info Select attribute, the attribute value is static and does not reflect the true value in the servo module. If the AXIS_SERVO_DRIVE is associated with a Kinetix Enhanced Safe Torque-Off or Advanced Safety Drive, these two additional Real Time Axis attributes are available. • Guard Status • Guard Faults If an AXIS_SERVO_DRIVE is associated with a Kinetix Advanced Safety Drive, we recommend configuring the Guard Status attribute. Otherwise, a warning appears when verifying the project.

130

If the AXIS_SERVO_DRIVE is associated with a Kinetix Advanced Safety Drive, and

Then

Attribute 1 or Attribute 2 is populated as Guard Status

No action is taken.

Attribute 1 or Attribute 2 is not populated as Guard Status

Attribute 2 is populated as Guard Status.

Attribute 2 is populated with an attribute other than Guard Status, and Attribute 1 is undefined

Attribute 1 is populated as Guard Status.

Attribute 1 and Attribute 2 are populated with an attribute other than Guard Status

Upon project verification, a warning is issued.

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018