Page 171

Axis properties

Appendix A

•

Phase Loss

When a parameter transitions to a read-only state, any pending changes to parameter values are lost, and the parameter reverts to the most recently saved parameter value. When multiple workstations connect to the same controller using the Logix Designer application and invoke the Axis Wizard or Axis Properties dialog box, the firmware allows only the first workstation to make any changes to axis attributes. The second workstation switches to a Read Only mode, indicated in the title bar, so the changes can only be viewed from that workstation, but not edited. Select one fault action for each fault type. •

Shutdown - If a fault action is set to Shutdown, when the associated fault occurs, axis servo action is immediately disabled, the servo amplifier output is zeroed, and the drive enable output is deactivated. Shutdown is the most severe action to a fault and usually reserved for faults that could endanger the machine or the operator if power is not removed as quickly and completely as possible.

•

Disable Drive - If a fault action is set to Disable Drive, when the associated fault occurs, it brings the axis to a stop by applying the Stopping Torque for up to the Stopping Time Limit. During this period, the servo is active but no longer tracking the command reference from Logix Designer. Once the axis is stopped (or the stopping limit is exceeded), the servo and power structure are disabled.

•

Stop Motion - If a fault action is set to Stop Motion, when the associated fault occurs, the axis immediately starts decelerating the axis command position to a stop at the configured Maximum Deceleration Rate without disabling servo action or the servo modules Drive Enable output. The gentlest stopping mechanism in response to a fault. Used for less severe

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

171

Page 172

Appendix A

Axis properties faults. After the stop command fault action has stopped the axis, no further motion can be generated until the fault is first cleared. •

Status Only - If a fault action is set to Status Only, when the associated fault occurs, no action is taken. The application program must handle any motion faults. In general, this setting should only be used in applications where the standard fault actions are not appropriate. ATTENTION: Selecting the wrong fault action for the application can cause a dangerous condition. Keep clear of moving machinery.

Parameter

Description

Drive Enable Input

Specifies the fault action to be taken when a Drive Enable Input Fault is detected, for an axis configured as Servo (in the General tab of this dialog box). The available actions for this fault are Shutdown, Disable Drive, Stop Motion, and Status Only.

Drive Thermal

Specifies the fault action to be taken when a Drive Thermal Fault is detected, for an axis configured as Servo (in the General tab of this dialog box). The available actions for this fault are Shutdown, Disable Drive, Stop Motion, and Status Only.

Motor Thermal

Specifies the fault action to be taken when a Motor Thermal Fault is detected, for an axis configured as Servo (in the General tab of this dialog box). The available actions for this fault are Shutdown, Disable Drive, Stop Motion, and Status Only.

Feedback Noise

Specifies the fault action to be taken when excessive feedback noise is detected. The available actions for this fault are Shutdown, Disable Drive, Stop Motion, and Status Only.

Feedback

Specifies the fault action to be taken when Feedback Fault is detected. The available actions for this fault are Shutdown, Disable Drive, Stop Motion, and Status Only.

Position Error

Specifies the fault action to be taken when position error exceeds the position tolerance set for the axis, for an axis configured as Servo (in the General tab of this dialog box). The available actions for this fault are Shutdown, Disable Drive, Stop Motion, and Status Only.

Hard Overtravel

Specifies the fault action to be taken when an axis encounters a travel limit switch, for an axis configured as Servo (in the General tab of this dialog box). The available actions for this fault are Shutdown, Disable Drive, Stop Motion, and Status Only.

Soft Overtravel

Specifies the fault action to be taken when a software overtravel error occurs, for an axis with Soft Travel Limits enabled and configured (in the Limits tab of this dialog box) that is configured as Servo (in the General tab of this dialog box). The available actions for this fault are Shutdown, Disable Drive, Stop Motion, and Status Only.

Phase Loss

Specifies the fault action to be taken when a phase loss situation occurs for an axis configured as Servo (on the General tab of this dialog box). The available actions for this fault are Shutdown, Disable Drive, Stop Motion and Status Only. The default is Shutdown. When Status Only is chosen, Logix Designer motion commands continue and the drive uses available stored DC bus energy to operate the axes.

Set custom stop

Opens the Custom Stop Action dialog box.

172

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

Page 173

Axis properties

Set custom stop action

Appendix A

Use the Custom Stop Action Attributes dialog box to monitor and edit the Stop Action-related attributes.

When a parameter transitions to a read-only state, any pending changes to parameter values are lost, and the parameter reverts to the most recently saved parameter value. When multiple workstations connect to the same controller using Logix Designer application and invoke the Axis Wizard or Axis Properties dialog box, the firmware allows only the first workstation to make any changes to axis attributes. The second workstation switches to view only. Attribute

Description

StoppingTorque

Displays the amount of torque available to stop the motor. The value range of this attribute is 0...1000.

StoppingTimeLimit

Displays the maximum amount of time that the drive amplifier remains enabled while trying to stop. Useful for very slow velocity rate change settings. The value range of this attribute is 0...6553.5 units.

BrakeEngageDelayTime

When servo axis is disabled and the drive decelerates to a minimum speed, the drive maintains torque until this time has elapsed. This time allows the motor’s brake to be set. The value range of this attribute is 0...6.5535.

BrakeReleaseDelayTime

When the servo axis is enabled, the drive activates the torque to the motor but ignores the command values from the Logix controller until this time has elapsed. This time allows the motor’s brake to release. The value range of this attribute is 0...6.5535.

ResistiveBrakeContactDelay

The Resistive Brake Contact Delay attribute is used to control an optional external Resistive Brake Module (RBM). The RBM sits between the drive and the motor and uses an internal contactor to switch the motor between the drive and a resisted load.

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

173

Page 174

Appendix A

Axis properties

Tag tab

Use this tab to modify the name and description of the axis. When online, all parameters on this tab transition to a read-only state. If changes are not saved before going online, all pending changes revert to their previously-saved state.

Parameter

Description

Name

Displays the name of the current tag. Cn rename this tag.

Description

Displays the description of the current tag, if any is available. Can edit this description.

Tag Type

Indicates the type of the current tag. This type may be: • Base • Alias • Consumed Displays the data type associated with the current tag.

Data Type

Displays the axis data type of the current tag.

Scope

Displays the scope of the current tag. The scope is controller scope, or program scope, based on one of the programs in the controller.

Style

Displays the default style in which to display the value of the tag. Note that style is only applicable to an atomic tag; a structure tag does not have a display style.

Monitoring axis tags

In Data Monitor or Tag Monitor, sort the tags alphabetically. Right-click on the Name column and select Sort Column.

174

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

Page 175

Axis properties

Appendix A

Optionally, select Include Tag Members in Sorting.

Create reports

Print a variety of reports in Logix Designer application. To create a report: 1. In the Controller Organizer, right-click Controller Tags, MainTask, MainProgram, axis, Add-On Instructions, or Data Types and select Print. 2. On the Print dialog box, select Adobe PDF and select Print Options.

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

175

Page 176

Appendix A

Axis properties

3. When printing a Tag Listing, select Include Special Properties and Advanced List to see the information.

Axis Properties Example

Right-click a controller, communication module, and any motion module to print the configured Module Properties.

176

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

Page 177

Axis properties

Appendix A

Module Properties Example

See also Axis properties on page 119

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

177

Page 178

This page is a scan with no text; see it in the PDF.

Page 179

Appendix B

Motion axis attributes

Introduction for Motion Axis Attributes

The Access column shows how to access the attribute. Attribute

Axis Type

Acceleration Feedforward Gain

Accessing an MSG instruction

Data Type

Access

Description

GSV

Use a Get System Value (GSV) instruction to get the value.

SSV

Use a Set System Value (SSV) instruction to set or change the value. Modify the attribute only when the axis is not enabled.

Accel Status

Tag

Actual Acceleration

GSV

Use the tag for the axis to get the value.

Tag

Use the tag for the axis or a GSV instruction to get the value. Using the tag is easier.

For complete information about accessing data using an MSG instruction, see Logix 5000 Controllers Messages Programming Manual, publication 1756PM012. For more information on Attribute and Class IDs, see the drive documentation.

Interpreting the Attribute Tables

This table provides an explanation of the information, nomenclature, and abbreviations used in the attribute tables. Column Heading

Description

Attribute

Each attribute table begins with the attribute name. The tag, GSV/SSV, and MSG names for each of these attributes are the same as the attribute name listed, but with the spaces removed. For example, Absolute Feedback Enable would be AbsoluteFeedbackEnable.

Axis Type

For each attribute, the related axis is listed.

Data Type

The data type, such as DINT, UINT, SINT, REAL, and BOOL.

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018

179

Page 180

Appendix B

Motion axis attributes

Replicated Attributes

180

Column Heading

Description

Access

GSV SSV Tag MSG

Description

Attribute value meanings, such as Position Units / Seconds. Supports tag access , but value is valid only when Auto Tag Update of the Motion Group Object is enabled.

Read via the GSV instruction. Write via the SSV instruction. Create to allocate and reference data. Message is only used to access drive attributes that have no GSV/SSV access. Using an MSG instruction to access information from a drive requires the Attribute and Class IDs. See the drive documentation for ID information.

Controller attributes replicated in the motion module: •

AccelerationFeedForwardGain

•

AxisType

•

DriveFaultAction

•

FeedbackFaultAction

•

FeedbackNoiseFaultAction

•

FrictionCompensation

•

MaximumNegativeTravel

•

MaximumPositiveTravel

•

OutputLPFilterBandwidth

•

OutputLimit

•

OutputOffset

•

PositionErrorFaultAction

•

PositionErrorTolerance

•

PositionIntegralGain

•

PositionProportionalGain

•

PositionUnwind

•

SoftOvertravelFaultAction

•

TorqueScaling

•

VelocityFeedforwardGain

•

VelocityIntegralGain

•

VelocityProportionalGain

Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018