The text of a manual · part 25 of 30
SERCOS and Analog Motion Configuration and Startup User Manual, pages 241 to 250
Pages 241 to 250 of 297
The original document is the PDF (13 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 1756-M16SE/A
Page 241
Motion axis attributes
Appendix B
Attribute
Axis Type
Data Type
Access
Description
Position Feedback
AXIS_SERVO AXIS_SERVO_DRIVE
REAL
GSV Tag
Important: To use this attribute, choose it as one of the attributes for Real Time Axis Information for the axis. Otherwise, the right value is not seen as the axis runs. See Axis Info Select 1. Position Feedback in Position Units Position Feedback is the current value of the Fine Actual Position into the position loop summing junction, in configured axis Position Units. Within the servo loop, the Position Feedback represents the current position of the axis.
Position Integral Gain
AXIS_SERVO AXIS_SERVO_DRIVE
REAL
GSV SSV
1/mSec-Sec This controller attribute is replicated in the motion module. Position Integral Gain (Pos I Gain) improves the steady-state positioning performance of the system. By using Position Integral Gain, it is possible to achieve accurate axis positioning despite the presence of such disturbances as static friction or gravity. Increasing the integral gain generally increases the ultimate positioning accuracy of the system. Excessive integral gain, however, results in system instability. Every servo update, the current Position Error is accumulated in a variable called the Position Integral Error. This value is multiplied by the Position Integral Gain to produce a component to the Velocity Command that attempts to correct for the position error. The characteristic of Pos I Gain correction, however, is that any non-zero Position Error accumulates in time to generate enough force to make the correction. This attribute of Pos I Gain makes it invaluable in applications where positioning accuracy or tracking accuracy is critical. The higher the Pos I Gain value the faster the axis is driven to the zero Position Error condition. Unfortunately, Pos I Gain control is intrinsically unstable. Too much Pos I Gain results in axis oscillation and servo instability. If the axis is configured for an external velocity loop servo drive, the Pos I Gain should be zero–most analog velocity loop servo amplifiers have integral gain of their own and do not tolerate any amount of Pos I Gain in the position loop without producing severe oscillations. If Pos I Gain is necessary for the application, the velocity integrator in the drive must be disabled. In certain cases, Pos I Gain control is disabled. One such case is when the servo output to the axis’ drive is saturated. Continuing integral control behavior in this case would only exacerbate the situation. Another common case is when performing certain motion. When the Integrator Hold Enable attribute is set, the servo loop automatically disables the integrator during commanded motion. While the Pos I Gain, if employed, is typically established by the automatic servo tuning procedure, the Pos I Gain value may also be set manually. Compute the Pos I Gain based on the current or computed value for the Pos P Gain using this formula: Pos I Gain = 0.25 * 0.001 Sec/mSec * (Pos P Gain)2 Assuming a Pos P Gain value of 100 Sec-1, this results in a Pos I Gain value of 2.5 ~0.1 mSec1 -Sec-1
Position Integrator Error
AXIS_SERVO AXIS_SERVO_DRIVE
REAL
GSV Tag
Important: To use this attribute, choose it as one of the attributes for Real Time Axis Information for the axis. Otherwise, the right value is not seen as the axis runs. See Axis Info Select 1. Position Integrator Error in Position Units - mSec Position Integrator Error is the running sum of the Position Error, in the configured axis Position Units, for the specified axis. For an axis with an active servo loop, the position integrator error is used, along with other error terms, to drive the motor to the condition where the actual position is equal to the command position.
Position Lock Status
AXIS_SERVO AXIS_SERVO_DRIVE
BOOL
Tag
If this bit is: • ON, The axis position error is less than or equal to the Position Lock Tolerance value of the axis. • OFF, The axis position error is greater than the Position Lock Tolerance value of the axis.
Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018
241
Page 242
Appendix B
Motion axis attributes
Attribute
Axis Type
Data Type
Access
Description
Position Lock Tolerance AXIS_SERVO AXIS_SERVO_DRIVE
REAL
GSV SSV
Position Units The Position Lock Tolerance attribute value specifies how much position error the motion module tolerates when giving a true Position Locked Status indication. When used in conjunction with the Position Locked Status bit, it is a useful parameter to control positioning accuracy. The Position Lock Tolerance value should be set, in Position Units, to the desired positioning accuracy of the axis. Note that the position lock tolerance value is interpreted as a ± quantity. For example, if the position units are Inches, specifying a position lock tolerance of 0.01 provides a minimum positioning accuracy of ±0.01 inches as shown below.
Position Polarity
INT
GSV
This attribute is derived from the Drive Polarity attribute. See IDN 55 in IEC 1491.
242
AXIS_SERVO_DRIVE
Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018
Page 243
Motion axis attributes
Appendix B
Attribute
Axis Type
Data Type
Access
Description
Position Proportional Gain
AXIS_SERVO AXIS_SERVO_DRIVE
REAL
GSV SSV
1/Seconds This controller attribute is replicated in the motion module. The Position Error is multiplied by the Position Proportional Gain (Pos P Gain) to produce a component to the Velocity Command that tries to correct for the position error. Increasing this gain increases the bandwidth of the position servo loop and results in greater static stiffness of the axis, which is a measure of the corrective force that is applied to an axis for a given position error. Too little Pos P Gain results in excessively compliant, or mushy, axis behavior. Too large a Pos P Gain results in axis oscillation due to servo instability. A well-tuned system moves and stops quickly and shows little or no ringing during constant velocity or when the axis stops. If the response time is poor, or the motion sloppy or slow, it may be necessary to increase the proportional gain. If excessive ringing or overshoot is observed when the motor stops, it may be necessary to decrease the proportional gain. While the tuning procedure sets the Pos P Gain, it can also be set manually. Compute the Pos P Gain based on the desired loop gain or the desired bandwidth of the position servo system. Loop Gain Method If the desired loop gain in Inches per Minute per mil or millimeters per minute per mil is known, use this formula to calculate the corresponding P gain. Pos P Gain = 16.667 * Desired Loop Gain (IPM/mil) A loop gain of 1 IPM/mil (Pos P gain = 16.7 Sec-1) gives stable positioning for most axes. However, position servo systems typically run much tighter than this. The typical value for the Position Proportional Gain is ~100 Sec-1. Bandwidth Method If the desired unity gain bandwidth of the position servo in Hertz is known, use this formula to calculate the corresponding P gain. Pos P Gain = Bandwidth (Hertz) / 6.28 Position servo systems typically run with at least a unity gain bandwidth of ~16 Hertz. The typical value for the Position Proportional Gain is ~100 Sec-1. Maximum Bandwidth There are limitations to the maximum bandwidth that can be achieved for the position loop based on the dynamics of the inner velocity and torque loops of the system and the desired damping of the system, Z. These limitations may be expressed as: Bandwidth (Pos) = 0.25 * 1/Z2 * Bandwidth (Vel) = 0.25 * 1/Z2 * Bandwidth (Torque) For example, if the bandwidth of the drive’s torque loop is 100 Hz and the damping factor, Z, is 0.8, the velocity bandwidth is approximately 40 Hz and the position bandwidth is 16 Hz. Based on these numbers, the corresponding proportional gains for the loops can be computed. Note that the bandwidth of the torque loop includes feedback sampling delay and filter time constant.
Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018
243
Page 244
Appendix B
Motion axis attributes
Attribute
Axis Type
Data Type
Access
Description
Position Servo Bandwidth
AXIS_SERVO AXIS_SERVO_DRIVE
REAL
GSV SSV
Hertz The value for the Position Servo Bandwidth represents the unity gain bandwidth that is to be used to calculate the gains for a subsequent MAAT (Motion Apply Axis Tune) instruction. The unity gain bandwidth is the frequency beyond which the position servo is unable to provide any significant position disturbance correction. In general, within the constraints of a stable servo system, the higher the Position Servo Bandwidth is the better the dynamic performance of the system. A maximum value for the Position Servo Bandwidth is generated by the MRAT (Motion Run Axis Tune) instruction. Computing gains based on this maximum value via the MAAT instruction results in dynamic response in keeping with the current value of the Damping Factor described above. Alternatively, the responsiveness of the system can be ‘softened’ by reducing the value of the Position Servo Bandwidth before executing the MAAT instruction. There are limitations to the maximum bandwidth that can be achieved for the position loop based on the dynamics of the inner velocity and current loops of the servo system and the desired damping of the system, Z. Exceeding these limits could result in an unstable system. These bandwidth limitations may be expressed as: Max Position Bandwidth (Hz) = 0.25 * 1/Z2 * Velocity Bandwidth (Hz) For example, if the maximum bandwidth of the velocity servo loop is 40 Hz and the damping factor, Z, is 0.8, the maximum position bandwidth is 16 Hz. Based on these numbers, the corresponding proportional gains for the loops can be computed.
Position Units
AXIS_CONSUMED AXIS_GENERIC AXIS_SERVO AXIS_SERVO_DRIVE AXIS_VIRTUAL
STRING
MSG
Fixed length string of 32 characters The Position Units attribute can support an ASCII text string of up to 32 characters. This string is used by Logix Designer software in the axis configuration dialog boxes to request values for motion-related parameters in the specified Position Units.
Position Unwind
AXIS_CONSUMED AXIS_GENERIC AXIS_SERVO AXIS_SERVO_DRIVE AXIS_VIRTUAL
DINT
GSV SSV
Counts per Revolution This controller attribute is replicated in the motion module. If the axis is configured as a rotary axis by setting the corresponding Rotary Axis bit Servo Configuration Bit word, a value for the Position Unwind attribute is required. This is the value used to perform automatic electronic unwind of the rotary axis. Electronic unwind allows infinite position range for rotary axes by subtracting the unwind value from the actual and command position every time the axis makes a complete revolution. To avoid accumulated error due to round-off with irrational conversion constants, the unwind value is requested in units feedback counts per axis revolution and must be an integer. For example, suppose that a given axis is configured as a Rotary Axis with Position Units of ‘Degrees’ and 10 feedback counts per degree. It is desired to unwind the axis position after every revolution. In this case, the Position Unwind attribute should be set to 3600 since there are 3600 feedback counts (10 * 360) per revolution of the axis.
Positive Dynamic Torque Limit
AXIS_SERVO_DRIVE
REAL
GSV Tag
Important: To use this attribute, choose it as one of the attributes for Real Time Axis Information for the axis. Otherwise, the right value is not seen as the axis runs. See Axis Info Select 1. %Rated The currently operative maximum positive torque/current limit magnitude. The value should be the lowest value of all torque/current limits in the drive at a given time. This limit includes the amplifier peak limit, motor peak limit, user current limit, amplifier thermal limit, and the motor thermal limit.
Power Capacity
AXIS_SERVO_DRIVE
REAL
GSV Tag
Important: To use this attribute, choose it as one of the attributes for Real Time Axis Information for the axis. Otherwise, the right value is not seen as the axis runs. See Axis Info Select 1. The present utilization of the axis power supply as a percent of rated capacity.
244
Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018
Page 245
Motion axis attributes
Appendix B
Attribute
Axis Type
Data Type
Access
Description
Power Limit Status
AXIS_SERVO_DRIVE
BOOL
Tag
Set when the magnitude of the actual supplied power is greater than the configured Power Threshold.
Power Phase Loss Fault AXIS_SERVO_DRIVE
BOOL
Tag
Set when the drive detects that one or more of the three power line phases is lost from the 3 phase power inputs.
Power Supply ID
AXIS_SERVO_DRIVE
INT
GSV
The Power Supply ID attribute contains the enumeration of the A-B Power Supply or System Module catalog numbers associated with the axis. If the Power Supply ID does not match that of the actual supply hardware, an error is generated during the drive configuration process.
Precharge Overload Fault
AXIS_SERVO_DRIVE
BOOL
Tag
The drive’s pre-charge resistor gets too hot if 3-phase power is cycled too many times. If that happens, this bit turns on.
Primary Operation Mode
AXIS_SERVO_DRIVE
INT
GSV
This attribute is derived from the Servo Loop Configuration attribute. See IDN 32 in IEC 1491.
Process Status
AXIS_SERVO AXIS_SERVO_DRIVE
BOOL
Tag
Set when there is an axis tuning operation or an axis hookup diagnostic test operation in progress on the axis.
Programmed Stop Mode
AXIS_GENERIC AXIS_SERVO AXIS_SERVO_DRIVE AXIS_VIRTUAL
SINT
GSV SSV
Determines how an axis stops when there is a critical controller mode change or when an MGS (Motion Group Stop) instruction executes with its stop mode set to Programmed. The modes of the controller are: Program Mode, Run Mode, Test Mode, and Faulted Mode. Any mode change into or out of program mode (prog->run, prog->test, run->prog & test>prog) initiates a programmed stop for every axis owned by that controller. Each individual axis can have its own Programmed Stop Mode configuration independent of other axes. Fast Stop (default) = 0 When the Programmed Stop Mode attribute is configured for Fast Stop, the axis is decelerated to a stop using the current configured value for Maximum Deceleration. Servo action is maintained after the axis motion stopped. Fast Disable = 1 When the Programmed Stop Mode attribute is configured for Fast Disable, the axis is decelerated to a stop using the current configured value for Maximum Deceleration. Servo action is maintained until the axis motion stopped at which time the axis is disabled, that is, Drive Enable disabled, and Servo Action disabled Hard Disable = 2 When configured for Hard Disable, the axis is immediately disabled, that is, Drive Enable disabled, Servo Action disabled, but the OK contact is left closed. Unless the drive is configured to provide some form of dynamic breaking, this results in the axis coasting to a stop. Fast Shutdown = 3 When configured for Fast Shutdown, the axis is decelerated to a stop as with Fast Stop. But, once the axis motion is stopped, the axis is placed in the Shutdown state, that is, Drive Enable disabled, servo action disabled, and the OK contact opened. To recover from the Shutdown state requires execution of one of the axis or group Shutdown Reset instructions (MASR or MGSR). Hard Shutdown = 4 When configured for Hard Shutdown, the axis is immediately placed in the Shutdown state, that is, Drive Enable disabled, Servo Action disabled, and the OK contact opened. Unless the drive is configured to provide some form of dynamic breaking, this results in the axis coasting to a stop. To recover from the Shutdown state requires execution of one of the axis or group Shutdown Reset instructions (MASR or MGSR).
Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018
245
Page 246
Appendix B
Motion axis attributes
Attribute
Axis Type
Data Type
Access
Description
PWM Frequency Select
AXIS_SERVO_DRIVE
SINT
GSV
The PWM Frequency Select attribute controls the frequency of the pulse width modulated voltage applied to the motor by the drive’s power structure. Higher PWM Frequency values reduce torque ripple and motor noise based on the motor’s electrical time constant. Higher PWM frequencies, however, mean higher switching frequencies, which tends to produce more heat in the drive’s power structure. So, for applications that have high torque demands, a lower PWM frequency is recommended. 0 = low frequency (default) 1 = high frequency
Reg 1 Input Status
AXIS_SERVO AXIS_SERVO_DRIVE
BOOL
Tag
If this bit is: • ON, Registration 1 input is active. • OFF, Registration 1 input is inactive.
Reg 2 Input Status
AXIS_SERVO AXIS_SERVO_DRIVE
BOOL
Tag
If this bit is: • ON, Registration 2 input is active. • OFF, Registration 2 input is inactive.
Reg Event 1 Armed Status
AXIS_CONSUMED AXIS_GENERIC AXIS_SERVO AXIS_SERVO_DRIVE AXIS_VIRTUAL
BOOL
Tag
Set when a registration checking is armed for registration input 1 through execution of the MAR (Motion Arm Registration) instruction. Cleared when a registration event occurs or an MDR (Motion Disarm Registration) instruction is executed for registration input 1.
Reg Event 1 Status
AXIS_CONSUMED AXIS_GENERIC AXIS_SERVO AXIS_SERVO_DRIVE AXIS_VIRTUAL
BOOL
Tag
Set when a registration event occurs on registration input 1. Cleared when another MAR (Motion Arm Registration) instruction or an MDR (Motion Disarm Registration) instruction is executed for registration input 1.
Reg Event 2 Armed Status
AXIS_CONSUMED AXIS_GENERIC AXIS_SERVO AXIS_SERVO_DRIVE AXIS_VIRTUAL
BOOL
Tag
Set when a registration checking is armed for registration input 2 through execution of the MAR (Motion Arm Registration) instruction. Cleared when a registration event occurs or an MDR (Motion Disarm Registration) instruction is executed for registration input 2.
Reg Event 2 Status
AXIS_CONSUMED AXIS_GENERIC AXIS_SERVO AXIS_SERVO_DRIVE AXIS_VIRTUAL
BOOL
Tag
Set when a registration event occurs on registration input 2. Cleared when another MAR (Motion Arm Registration) instruction or an MDR (Motion Disarm Registration) instruction is executed for registration input 2.
Registration 1 Position
AXIS_CONSUMED AXIS_SERVO_DRIVE AXIS_VIRTUAL
REAL
Tag
Registration 1 Position in Position Units
Registration 1 Event Task Registration 2 Event Task
AXIS_CONSUMED AXIS_GENERIC AXIS_SERVO AXIS_SERVO_DRIVE AXIS_VIRTUAL
DINT
MSG
These attributes show which task is triggered when the registration event happens. • An instance of 0 means that no event task is configured to be triggered by the registration event. • The triggering of the task occurs simultaneously with the setting of the Process Complete bit for the instruction that armed the watch event. • The controller sets these attributes. Do not set them by an external device.
246
Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018
Page 247
Motion axis attributes
Appendix B
Attribute
Axis Type
Data Type
Access
Description
Registration 1 Position Registration 2 Position
AXIS_CONSUMED AXIS_GENERIC AXIS_SERVO AXIS_SERVO_DRIVE AXIS_VIRTUAL
REAL
GSV Tag
Position Units Two registration position attributes are provided to independently store axis position associated with two registration input events. The Registration Position value is the absolute position of a physical or virtual axis (in the position units of that axis) at the occurrence of the most recent registration event for that axis. The figure below shows how the registration position is latched by the registration input when a registration event occurs. The latching mechanism can be implemented in the controller software (soft registration) or, for greater accuracy, in physical hardware (hard registration).
The Registration Latch mechanism is controlled by two Event Control instructions, MAR (Motion Arm Registration) and MDR (Motion Disarm Registration). The accuracy of the registration position value, saved as a result of a registration event, is a function of the delay in recognizing the specified transition (typically 1 µsec for hardware registration) and the speed of the axis during this time. The uncertainty in the registration position is the distance traveled by the axis during this interval as shown by the equation.
Use the formula given above to calculate the maximum registration position error for the expected axis speed. Alternatively, Calculate the maximum axis speed for a specified registration accuracy by re-arranging this formula as shown.
Registration 1 Time Registration 2 Time
AXIS_CONSUMED AXIS_GENERIC AXIS_SERVO AXIS_SERVO_DRIVE AXIS_VIRTUAL
DINT
GSV Tag
Lower 32 bits of CST time The two Registration Time values contain the lower 32-bits of CST time at which their respective registration events occurred. Units for this attribute are in microseconds.
Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018
247
Page 248
Appendix B
Motion axis attributes
Attribute
Axis Type
Resistive Brake Contact AXIS_SERVO_DRIVE Delay
Data Type
Access
Description
REAL
GSV SSV
Sec This attribute controls an optional external Resistive Brake Module (RBM). The RBM is between the drive and the motor and uses an internal contactor to switch the motor between the drive and a resistive load. The drive’s RBM output controls this contactor. When the drive’s RBM output is energized, the RBM contactor is switched from the load resistors to the UVW motor lines connecting the drive to the motor. This switching does not occur instantaneously and enabling the power structure too early can cause electrical arcing across the contactor. The resistive brake contact delay is the time needed to fully close the contactor across the UVW motor lines. To prevent electrical arcing across the contactor, the enabling of the drive’s power structure is delayed. The delay time is variable depending on the RBM model. When applying an RBM, set the Resistive Brake Contact Delay to the recommended value found in the RBM specification. These cases outline how the RBM output relates to the normal enable and disable sequences. Case 1 – Enable Sequence 1. Enable axis is initiated via MSO or MAH instruction. 2. Turn on RBM output to connect motor to drive. 3. Wait for Resistive Brake Contact Delay while RBM contacts close. 4. Drive power structure enabled (Drive Enable Status bit is set). 5. Turn on motor brake output to release brake. 6. Wait Brake Release Delay Time while motor brake releases. 7. Track Command reference (Servo Action Status bit is set). Case 2 – Disable - Category 1 Stop 1. Disable axis is initiated via an MSF instruction or a drive disable fault action. 2. Drive stops tracking command reference (Servo Action Status bit is cleared). 3. Apply Stopping Torque to stop motor. 4. Wait for zero speed or Stopping Time Limit. 5. Turn off brake output to engage motor brake. 6. Wait for Brake Engage delay while motor brake engages. 7. Disable drive power structure (Drive Enable Status bit is cleared). 8. Turn off RBM output to disconnect motor from drive. Case 3 – Shutdown Category 0 Stop 1. Drive stops tracking command reference (Servo Action Status bit is cleared). 2. Disable drive power structure (Drive Enable Status bit is cleared). 3. Turn off brake output to engage brake. 4. Turn off RBM output to disconnect motor from drive.
Rotary Axis
AXIS_CONSUMED AXIS_GENERIC AXIS_SERVO AXIS_SERVO_DRIVE AXIS_VIRTUAL
SINT
GSV SSV* * Can only be set if axis is not enabled.
0 = Linear 1 = Rotary When the Rotary Axis attribute is set true (1), it lets the axis unwind. This gives infinite position range by unwinding the axis position whenever the axis moves through a complete physical revolution. The number of encoder counts per physical revolution of the axis is specified by the Position Unwind attribute. For Linear operation, the counts do not roll over. They are limited to +/- 2 billion.
Rotary Motor Inertia
AXIS_SERVO_DRIVE
REAL
SSV
The Rotary Motor Inertia attribute is a float that specifies the unloaded inertia of a rotary motor.
248
Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018
Page 249
Motion axis attributes
Appendix B
Attribute
Axis Type
Data Type
Access
Description
Rotary Motor Rated Speed
AXIS_SERVO_DRIVE
REAL
GSV
The Rotary Motor Rated Speed attribute is a float that specifies the nameplate rated speed of a rotary motor. For PM motors, this is generally specified at rated voltage based on rated current, rated torque, or rated power. For induction motors, this value is the speed of the motor driven at rated frequency under rated torque load. This value is synonymous with the term base speed.
Safe-Off Mode Active Status
AXIS_SERVO_DRIVE
BOOL
GSV Tag
This bit is the status indication of the Kinetix Drive’s Safe-Off circuitry. If the state is: • ON - The Drive’s Safety monitor circuitry encountered a loss of signal from Enable_1 or Enable_2. • OFF - The Drive’s Safety monitor circuitry did not fault from Enable_1 or Enable_2. For the Kinetix Drive to pass back this status to the controller via this bit, the Drive must have firmware version 1.85 or higher.
SERCOS Error Code
AXIS_SERVO_DRIVE
INT
GSV* Tag
Error code returned by SERCOS module indicating source of drive parameter update failure. The SERCOS Error Code value can be used to identify the source of the drive parameter update failure that resulted in the Axis Configuration Fault.
SERCOS Fault
AXIS_SERVO_DRIVE
BOOL
Tag
Set when a requested SERCOS procedure fails to execute properly or the associated drive node detected a SERCOS communication fault.
SERCOS Ring Fault
AXIS_SERVO_DRIVE
BOOL
Tag
If this bit is set, there is a problem on the SERCOS ring; that is, the light is broken or a drive is powered down.
Servo Action Status
AXIS_CONSUMED AXIS_GENERIC AXIS_SERVO AXIS_SERVO_DRIVE AXIS_VIRTUAL
BOOL
Tag
If this bit is: • ON, The axis is under servo control.
AXIS_SERVO
DINT
Servo Fault
• OFF, Servo action is disabled.
Tag
Allows access to all servo fault bits in one 32-bit word. This tag is the same as the Servo Fault Bits attribute. Servo Fault
Bit
Pos Soft Overtravel Fault
0
Neg Soft Overtravel Fault
1
Reserved
2
Reserved
3
Feedback Fault
4
Feedback Noise Fault
5
Reserved
6
Reserved
7
Positive Error Fault
8
Drive Fault
9
These fault bits are updated every base update period. Should any of these faults give the controller a major fault? YES, Set the General Fault Type of the motion group = Major Fault. NO, Write code to handle these faults. Servo Fault Bits
AXIS_SERVO
DINT
GSV*
Allows access to all servo fault bits in one 32-bit word. This attribute is the same as the Servo Fault tag. Servo Fault
Bit
Pos Soft Overtravel Fault
0
Neg Soft Overtravel Fault
1
Rockwell Automation Publication MOTION-UM001H-EN-P - November 2018
249
Page 250
Appendix B
Motion axis attributes
Attribute
Axis Type
Data Type
Access
Description Reserved
2
Reserved
3
Feedback Fault
4
Feedback Noise Fault
5
Reserved
6
Reserved
7
Positive Error Fault
8
Drive Fault
9
These fault bits are updated every base update period. Should any of these faults to give the controller a major fault? YES, Set the General Fault Type of the motion group = Major Fault. NO, Write code to handle these faults.
250