Page 161

Chapter 9 Error Messages and Anomalies

9.4 Anomalies (continued)

9. If you use a VT100 terminal, the BASIC Module can miss an XON character sent by your terminal when you enable software handshaking and use a 19.2K baud rate on the module’s program port. You must type CTRL Q to resume. 10. If you use a CTRL C to abort LIST# or PRINT# to a peripheral device, the BASIC Module no longer transmits on the program port (only at 9600 or 19.2 K baud). You can correct the problem by deleting any line. The line deleted need not actually exist in the program. 11. Illegal CALL numbers above 128 are not trapped and cause the micro to jump into code memory at the address specified. This can cause the module to get “lost”. 12. The BASIC Module does not save the EPROM stored baud rate. Example: The module is powered up after a CALL 73 is issued and a valid baud rate is previously stored in EPROM using a PROG1. If the module is powered down and then up, it is powered up at 1200 baud. 13. The renumber routine does not renumber a program if there is insufficient RAM left or if a GOTO or GOSUB exists and the target line number does not. Error reporting does not indicate the cause, only that an error occurred. We recommend renumbering the program in sections and not to renumber a program greater than 9 K. 14. When editing a line, an excessive line length may cause the terminal to issue a CTRL S. A CTRL Q causes termination of the edit. You must retype the complete line. 15. The BASIC Module updates the wall clock for Daylight Savings Time. This occurs on the last Sunday in April and October if the Day of Week is set properly (CALL 42).

9–9

Page 162

Appendix A

Quick Reference Guide Mnemonic

Page

Description

ABS( ) ASC( ) ATN( ) CALL CHR( ) CLEAR CLEARI CLOCK0 CLOCK1 CONT CONTROL C CONTROL S CONTROL Q COS( ) DATA DIM DO END EXP( ) FOR-TO (STEP) GET GOSUB GOTO IF-THEN-ELSE INPUT INT( ) LD@ LEN

5–45 5–72 5–47 5–16 5–74 5–16 5–16 5–17 5–17 5–7 5–9 5–10 5–10 5–47 5–18 5–19 5–19 5–22 5–46 5–22 5–50 5–23 5–24 5–25 5–26 6–45 5–28 5–52

LET

5–29

LIST

5–7

ABSOLUTE VALUE RETURNS INTEGER VALUE OF ASCII CHARACTER RETURNS ARCTANGENT OF ARGUMENT CALL APPLICATION PROGRAM COUNTS VALUE CONVERTED ASCII CHARACTER CLEARS VARIABLES, INTERRUPTS & STRINGS CLEAR INTERRUPTS DISABLE REAL TIME CLOCK ENABLE REAL TIME CLOCK CONTINUE AFTER A STOP OR CONTROL-C STOP EXECUTION & RETURN TO COMMAND MODE INTERRUPT A LIST COMMAND RESTART A LIST AFTER CONTROL S RETURNS THE COSINE OF ARGUMENT DATA TO BE READ BY READ STATEMENT ALLOCATE MEMORY FOR ARRAY VARIABLES SET UP LOOP FOR WHILE OR UNTIL TERMINATE PROGRAM EXECUTION “e” (2.7182818) TO THE X SET UP FOR NEXT LOOP READ CONSOLE EXECUTE SUBROUTINE GOTO PROGRAM LINE NUMBER CONDITIONAL TEST INPUT A STRING OR VARIABLE INTEGER LOAD VARIABLE READ THE NUMBER OF BYTES OF MEMORY IN THE CURRENT SELECTED PROGRAM ASSIGN A VARIABLE OR STRING A VALUE (LET IS OPTIONAL) LIST PROGRAM TO THE CONSOLE DEVICE

LIST#

5–8

LIST PROGRAM TO SERIAL PRINTER

LOG( ) MTOP NEW NEXT NOT( ) NULL

5–46 5–52 5–9 5–22 5–45 5–9

NATURAL LOG READ THE LAST VALID MEMORY ADDRESS ERASE THE PROGRAM STORED IN RAM TEST FOR-NEXT LOOP CONDITION ONE’S COMPLEMENT SET NULL COUNT AFTER CARRIAGE RETURN-LINE FEED

ONERR ON GOTO ON GOSUB ONTIME

5–30 5–25 5–25 5–31

ONERR OR GOTO LINE NUMBER CONDITIONAL GOTO CONDITIONAL GOSUB GENERATE AN INTERRUPT WHEN TIME IS EQUAL TO OR GREATER THAN ONTIME ARGUMENT-LINE NUMBER IS AFTER COMMA

Example ABS(–3) P.ASC(A) ATN(1) CALL 10 P.CHR(65) CLEAR CLEARI CLOCK0 CLOCK1 CONT CTRL C CTRL S CTRL Q CPS(0) DATA 100 DIM A(20) DO END EXP(10) FOR A=1 TO 5 P.GET GOSUB 1000 GOTO 5000 IF AtC THEN A=0 INPUT A INT(3.2) LD@ 14335 PRINT LEN LET A=10 LIST LIST 10–50 LIST# LIST# 50 LOG(10) PRINT MTOP NEW NEXT A NOT(0) NULL NULL 4 ONERR 1000 ON A GOTO 5,20 ON A GOSUB 2,6 ONTIME 10, 1000

Page 163

Appendix A Quick Reference Guide

PH0 PH1 PH0.# PH1.# PI POP PRINT

Mnemonic 5–37 5–37 5–37 5–37 5–46 5–38 5–32

PRINT# PRINT CR PRINT SPC(5) PRINT TAB(#) PRINT USING (Fx) PRINT USING(#.#) PROG PROG1 PROG2

5–36 5–33 5–33 5–33 5–34 5–35 5–12 5–14 5–14

PUSH RAM

5–37 5–10

READ REM RESTORE RETI RETURN RND ROM #

5–18 5–40 5–18 5–41 5–23 5–46 5–10

RUN SGN SIN( ) SQR( ) ST@ STOP STRING #,#

5–5 5–45 5–46 5–45 5–41 5–41 5–42

TAN( ) TIME

5–47 5–50

Description PRINT HEX MODE WITH ZERO SUPPRESSION PRINT HEX MODE WITH NO ZERO SUPPRESSION PH0. TO LINE PRINTER PH1.# TO LINE PRINTER PI – 3.1415926 POP ARGUMENT STACK TO VARIABLES PRINT VARIABLES, STRINGS OR LITERALS P, IS SHORTHAND FOR PRINT PRINT TO SOFTWARE SERIAL PORT PRINT I, CR PRINT “A”, SPC(5), “B” PRINT TAB(5), “x” PRINT USING (F3), 1,2 PRINT USING (##.##), 1,2 SAVE THE CURRENT PROGRAM IN EPROM SAVE BAUD RATE INFORMATION IN EPROM SAVE BAUD RATE INFORMATION IN EPROM AND EXECUTE PROGRAM AFTER RESET PUSH EXPRESSIONS ON ARGUMENT STACK EVOKE RAM MODE, CURRENT PROGRAM IN READ/WRITE MEMORY READ DATA IN DATA STATEMENT REMARK RESTORE READ POINTER RETURN FROM INTERRUPT RETURN FROM SUBROUTINE RANDOM NUMBER EVOKE ROM MODE, EPROM PROGRAM #, DEFAULT TO ROM1 EXECUTE A PROGRAM SIGN RETURNS THE SINE OF ARGUMENT SQUARE ROOT STORE VARIABLE BREAK PROGRAM EXECUTION ALLOCATE MEMORY FOR STRINGS # BYTES TO ALLOCATE, # BYTES/STRING RETURNS THE TANGENT OF THE ARGUMENT RETRIEVE AND/OR ASSIGN REAL TIME CLOCK VALUE

UNTIL WHILE XFER + / ** * – .AND. .OR. .XOR.

5–5 5–5 5–12 5–43 5–43 5–43 5–43 5–43 5–43 5–43 5–43

TEST DO LOOP CONDITION TEST DO LOOP CONDITION TRANSFER A PROGRAM FROM ROM/EPROM TO RAM ADDITION DIVISION EXPONENTIATION MULTIPLICATION SUBTRACTION LOGICAL AND LOGIC OR LOGICAL EXCLUSIVE OR

A–2

Page

Example PH0.A PH1.A PH0.#A PH1.#A PI POP A,C,D PRINT A PRINT# A A....B ....x 1. .00E0 2.00E0 1.002.00 PROG PROG1 PROG2 PUSH10,A RAM READ A REM DONE RESTORE RETI RETURN RND ROM ROM3 RUN SGN (–5) SIN(3.14) SQR(100) ST@ 14335 STOP STRING 50,10 TAN(0) PRINT TIME TIME=0 UNTIL A=10 WHILE A=C XFER 1+1 10/2 2**4 4*2 8–4 10,AND.5 2.OR.1 3.XOR.2

Page 164

Appendix B

Decimal/Hexadecimal/Octal/ASCII Conversion Table Column 1

Column 2

Column 3

Column 4

DEC

HEX

OCT

ASC

DEC

HEX

OCT

ASC

DEC

HEX

OCT

ASC

DEC

HEX

OCT

ASC

00

00

000

NUL

32

20

040

SP

64

40

100

@

96

60

140

\

01

01

001

SOH

33

21

041

!

65

41

101

A

97

61

141 a

02

02

002

STX

34

22

042

″

66

42

102

B

98

62

142 b

03

03

003

ETX

35

23

043

#

67

43

103

C

99

63

143 c

04

04

004

EOT

36

24

044

$

68

44

104

D

100

64

144 d

05

05

005

ENQ

37

25

045

%

69

45

105

E

101

65

145 e

06

06

006

ACK

38

26

046

&

70

46

106

F

102

66

146 f

07

07

007

BEL

39

27

047 i

71

47

107

G

103

67

147 g

08

08

010

BS

40

28

050

(

72

48

110

H

104

68

150 h

09

09

011

HT

41

29

051

)

73

49

111

I

105

69

151 i

10

0A

012

LF

42

2A

052

*

74

4A

112

J

106

6A

152 j

11

0B

013

VT

43

2B

053

+

75

4B

113

K

107

6B

154 k

12

0C

014

FF

44

2C

054

’

76

4C

114

L

108

6C

154 l

13

0D

015

CR

45

2D

055

–

77

4D

115

M

109

ED

155 m

14

0E

016

S0

46

2E

056

.

78

4E

116

N

110

6E

156 n

15

0F

017

SI

47

2F

057

/

79

4F

117

O

111

6F

157 o

16

10

020

DLE

48

30

060

0

80

50

120

P

112

70

160 p

17

11

021

DC1

49

31

061

1

81

51

121

Q

113

71

161 q

18

12

022

DC2

50

32

062

2

82

52

122

R

114

72

162 r

19

13

023

DC3

51

33

063

3

83

53

123

S

115

73

163 s

20

14

024

DC4

52

34

064

4

84

54

124

T

116

74

164 t

21

15

025

NAK

53

35

065

5

85

55

125

U

117

75

165 u

22

16

026

SYN

54

36

066

6

86

56

126

V

118

76

166 v

23

17

027

ETB

55

37

067

7

87

57

127

W

119

77

167 w

24

18

030

CAN

56

38

070

8

88

58

130

X

120

78

170 x

25

19

031

EM

57

39

071

9

89

59

131

Y

121

79

171 y

26

1A

032

SUB

58

3A

072

:

90

5A

132

Z

122

7A

172 z

27

1B

033

ESC

59

3B

073

;

91

5B

133

[

123

7B

173

{

28

1C

034

FS

60

3C

074

<

92

5C

134

\

124

7C

174

.

29

1D

035

GS

61

3D

075

=

93

5D

135

]

125

7D

175

}

30

1E

036

RS

62

3E

076

>

94

5E

136

^

126

7E

176

~

31

1F

037

US

63

3F

077

?

95

5F

137

_

127

7F

177

DEL

Page 165

2

Page 166

Appendix C

Basic Module Programming Hints

BASIC Module Programming Hints

These programming hints can help you to properly program your module to increase module performance. 1. Always define strings first. 2. Always dimension arrays after defining strings. 3. Define the most used variables first. You can use 0 values until you assign real values. 4. When doing math, save intermediate values rather than recalculate. 5. Place the most used subroutines near the beginning of the program. 6. Straight through code executes faster, but uses more memory. 7. Put multiple statements on a line, after the program has been debugged. 8. Comments use space and slow program execution. After the program is debugged save a fully commented copy on tape or spare ERROM and remove comments.

Page 167

Allen-Bradley, a Rockwell Automation Business, has been helping its customers improve productivity and quality for more than 90 years. We design, manufacture and support a broad range of automation products worldwide. They include logic processors, power and motion control devices, operator interfaces, sensors and a variety of software. Rockwell is one of the world’s leading technology companies.

Worldwide representation. Argentina • Australia • Austria • Bahrain • Belgium • Brazil • Bulgaria • Canada • Chile • China, PRC • Colombia • Costa Rica • Croatia • Cyprus • Czech Republic • Denmark • Ecuador • Egypt • El Salvador • Finland • France • Germany • Greece • Guatemala • Honduras • Hong Kong • Hungary • Iceland • India • Indonesia • Ireland • Israel • Italy • Jamaica • Japan • Jordan • Korea • Kuwait • Lebanon • Malaysia • Mexico • Netherlands • New Zealand • Norway • Pakistan • Peru • Philippines • Poland • Portugal • Puerto Rico • Qatar • Romania • Russia–CIS • Saudi Arabia • Singapore • Slovakia • Slovenia • South Africa, Republic • Spain • Sweden • Switzerland • Taiwan • Thailand • Turkey • United Arab Emirates • United Kingdom • United States • Uruguay • Venezuela • Yugoslavia

Allen-Bradley Headquarters, 1201 South Second Street, Milwaukee, WI 53204 USA, Tel: (1) 414 382-2000 Fax: (1) 414 382-4444

Publication 1771–6.5.34 July 1987

PN 955101–26 Copyright 1987 Allen-Bradley Company, Inc. Printed in USA

Publication 1771–6.5.34 July 1987