Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeContact
Page 1 of DC (10-30V) Input Module, Cat. No. 1771-IVN, Installation Data

Manual · Allen-Bradley

DC (10-30V) Input Module, Cat. No. 1771-IVN, Installation Data

Manual8 pagesPDF 100 KB

Installation data for the Allen-Bradley 1771-IVN 32-point DC (10-30 V) source input module for 1771 I/O chassis.

Download the PDF100 KB

Covers · 1 model

The models it covers

Summary

What is in it

Allen-Bradley installation data for the 1771-IVN DC (10-30V) input module, a 32-input source module for series B 1771 I/O chassis. It covers pre-installation considerations and processor compatibility, backplane power requirements, handling, keying the chassis, inserting the module, wiring through the 1771-WN field wiring arm with a connection diagram and terminal assignments, the status indicators and the module specifications.

Its parts

  1. To The Installer
  2. Pre-installation Considerations
  3. Power Supply Requirements
  4. Installing Your Module
  5. Interpreting the Status Indicators
  6. Specifications

From the manual · read page by page

Key facts from this manual

Each line names its page in the PDF.

Allen-Bradley installation data (publication 1771-2.169, June 1990) for the 1771-IVN DC (10-30V) input module. It covers processor compatibility, chassis keying, inserting the module, wiring the 1771-WN field wiring arm, reading the status indicators, and the module specifications.

Type
32-input DC source input module; needs sink outputs from the field devices p. 1, 8
Input voltage
10 to 30V dc p. 8
Chassis
Series B 1771 I/O chassis, 1771-A1B through -A4B p. 1, 8
Wiring arm
1771-WN; screw torque 7-9 inch-pounds p. 8
Backplane current
280mA at 5V dc maximum p. 8
Field power
Four independent 10-30V dc terminal pairs (01/02, 11/12, 21/22, 31/32), feeding terminals 03-10, 13-20, 23-30 and 33-40 p. 5
Processors, local
Mini-PLC-2/02, Mini-PLC-2/16, Mini-PLC-2/17, PLC-5/15 Series B and later p. 1
Processors, remote
With a 1771-ASB adapter: PLC-2/20, PLC-2/30, PLC-3, PLC-3/10, PLC-5/15 Series B and later p. 1
Input current
Nominal 4.5mA; minimum off-state 1.7mA; input impedance 2.2K p. 8
Input delay
6ms (+2ms) low to high and high to low p. 8
Keying
Between 14 and 16, and between 30 and 32 p. 3, 8
Isolation
1500V ac RMS p. 8
Power dissipation
15.6W max, 1.5W min p. 8
Temperature
Operating 0 to 60 C (32 to 140 F); storage -40 to 85 C; humidity 5 to 95% noncondensing p. 8

What this manual walks you through

  • Checking processor and chassis compatibility p. 1, 2
  • Keying the I/O chassis slot p. 3
  • Inserting the module into the chassis p. 3
  • Wiring the field wiring arm and terminal assignments p. 3, 4, 5
  • Reading the 32 status indicators p. 6
  • Module specifications p. 8

Good to know

  • Do not put the module in the same chassis as a 1771-IX thermocouple module; the 1771-IXE is allowed. p. 2
  • Remove power from the chassis backplane and wiring arm before removing or installing a module. p. 2
  • Reversed polarity or AC voltage on the DC power terminals could damage the module. p. 5
  • With 14 gauge wire on every terminal, the wiring arm cover may not close. p. 8
  • Wiring arm terminal numbers are not the same as the bit numbers. p. 3

Questions this manual answers

Is the 1771-IVN a sinking or sourcing input module?

It is a source input module and needs sink outputs from the field devices. p. 1

What wiring arm does the 1771-IVN use?

The 1771-WN field wiring arm, tightened to 7-9 inch-pounds. p. 8

How many inputs does the 1771-IVN have?

32 inputs, two full module groups in one slot, for 10 to 30V dc. p. 4, 8

Which chassis does the 1771-IVN fit?

A series B 1771 I/O chassis, 1771-A1B through -A4B. p. 1, 8

Can the 1771-IVN share a chassis with a thermocouple module?

Not with a 1771-IX, but it can share a chassis with a 1771-IXE. p. 2

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. 1771-2.168, DC (10-30V) Input Module, Installation Data1
  2. To The Installer1
  3. Pre-installation Considerations1
  4. Power Supply Requirements2
  5. Installing Your Module2
    1. Initial Handling Procedures2
    2. Keying the I/O Chassis3
    3. Inserting the Module Into the Chassis3
    4. Connecting Wiring to the Module3
  6. Interpreting the Status Indicators6
  7. Specifications8
  8. Back Cover8

From the PDF’s own bookmarks.

The whole text · 1 part

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 81-8

The file

Revision and size

RevisionPublication 1771-2.169, June 1990
PublisherAllen-Bradley
Pages8
PDF100 KB
TextText from the PDF itself.

The first pages · 3 of 8

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 8
Page 2
Page 2of 8
Page 3
Page 3of 8