The text of a manual · part 53 of 59
Mini-PLC-2/02, -2/16, -2/17 Processor (cat. no. 1772-LZ, LZP, LX, LXP, LW, LWP) User Manual: D - Glossary, pages 429 to 437
Pages 429 to 437 of 490, from Mini-PLC-2/02, -2/16, -2/17 Processor (cat. no. 1772-LZ, LZP, LX, LXP, LW, LWP) User Manual
The original document is the PDF (2.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 1772-LX / LXP
Page 429
Appendix D Glossary
H
Hardware The mechanical, electrical, and electronic devices which compose a programmable controller and its application Header Rung The first level of a ladder diagram program. It is a requirement when programming PLC-2 family processors or on the Data Highway. Hexadecimal Numbering System A base-16 numbering system that uses the symbols 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, and A, B, C, D, E, F. High=True A signal type where the higher of two voltages indicates a logic state of On (1). See Low=True.
I
Image Table An area in processor memory dedicated to I/O data. Ones and zeros (1 and 0) represent On and Off conditions, respectively. During every I/O scan, each discrete input controls a bit in the input image table; each discrete output is controlled by a bit in the output image table. Information The meaning assigned to data by known conventions. Input Devices Devices such as limit switches, pressure switches, pushbuttons, analog devices, and/or digital devices, that supply data to a processor. Instruction A command that causes a processor to perform one specific operation. The user enters a combination of instructions into processor memory to form a unique application program. Integer Any positive or negative whole number or zero. Intelligent I/O Module Microprocessor-based modules that perform processing or sophisticated closed-loop, application functions. Interference Any undesired electrical signal induced into a conductor by electrostatic or electromagnetic means.
D-10
Page 430
Appendix D Glossary
Interlock A device actuated by the operation of some other device to which it is associated, to govern the succeeding operation of the same or allied devices. I/O Input/Output I/O Channel A data transmission link between a processor scanner module and an I/O adapter module. I/O Chassis See chassis I/O Module A device that interfaces between the user devices and the processor. I/O Rack See Rack. I/O Scan Time The time required for the processor to monitor inputs and control outputs. I/O Terminal A terminal on the I/O module. One I/O terminal has a corresponding bit address in the data table. Isolated I/O Module A module which has each input or output electrically isolated from every other input or output on that module.
K
K 210 = 1K = 1024. Used to denote sizes of memory and can be used in bits, bytes, or words. Example: 2K = 2048. k Kilo. A prefix used with units of measurement to designate quantities 1000 times as great. Keying Plastic bands installed on backplane connectors to ensure that only one type of module can be inserted into a keyed connector.
D-11
Page 431
Appendix D Glossary
L
Ladder Diagram An industry standard for representing control systems. Ladder Diagram Programming A method of writing a user program in a format similar to a relay ladder diagram. Language A set of symbols and rules used for representing and communicating information. Latching Relay A relay that maintains a given position by mechanical or electrical means until released mechanically or electrically. Leading Edge One-Shot A programming technique that sets a bit for one scan when its input condition has made a false-to-true transition. The false-to-true transition represents the leading edge of the input pulse. Least Significant Bit (LSB) The bit that represents the smallest value in a nibble, byte, or word. Least Significant Digit (LSD) The digit that represents the smallest value in a byte or word. LED Light-Emitting Diode. LED Display An illuminated visual readout composed of alphanumeric character segments. Limit Switch An electrical switch actuated by some part and/or motion of a machine or equipment. Line (1) A component part of system used to link various subsystems located remotely from the processor. (2) The source of power for operation. Example: 120V ac line. Liquid Crystal Display (LCD) A reflective visual readout of alphanumeric characters. Since its character segments are displayed only by reflected light, it has extremely low power consumption. Contrasted with LED Display, which emits light.
D-12
Page 432
Appendix D Glossary
Load (1) The power used by a machine or apparatus. (2) To place data into an internal register under program control. (3) To place a program from an external storage device into central memory under operator control. Load Resistor A resistor connected in parallel with a high impedance load so the output circuit driving the load can provide at least the minimum current required for proper operation. Local I/O Processor A processor where I/O distance is physically limited and must be located near the processor. However, it may still be mounted in a separate enclosure. See Remote I/O Processor. Location A storage position in memory. Uniquely specified in Allen-Bradley processors by 5-, 6-, 7-, 8-, or 9-digit address. Logic A systematic means of solving complex problems through the repeated use of the AND, OR, NOT functions (they can be either true or false). Often represented by ladder diagrams. Logic Diagram A diagram which represents the logic elements and their interconnections. Logic Level The voltage magnitude associated with signal pulses representing ones and zeros (1 and 0) in binary computation. Loop A sequence of instructions which is executed repeatedly until a terminating condition is satisfied. Low=True A signal type where the lower of two voltages indicates a logic state of ON (1). See High=True. Lower Nibble The four least significant bits of a byte. LSB See Least Significant Bit. LSD See Least Significant Digit.
D-13
Page 433
Appendix D Glossary
M
Master A device used to control secondary devices. Master Control Relay (MCR) A mandatory hardwired relay that can be de-energized by any series-connected emergency stop switch. Whenever the master control relay is de-energized, its contacts open to de-energize all application I/O devices. Master Control Reset (MCR) See MCR Zones MCR Zones User program areas where all non-retentive outputs can be turned off simultaneously. Each MCR zone must be delimited and controlled by MCR fence codes (MCR instructions). Memory A group of circuit elements that can store or retrieve data. Memory Map A diagram showing a system’s memory addresses and what programs and data are assigned to each section of memory. Message (1) A meaningful combination of alphanumeric characters which establishes the content and format of a report. (2) An information unit designated for transfer by a single command form the application to the network. MOS Metal Oxide Semiconductor. A semiconductor device in which an electric field controls the conductance of a channel under a metal electrode called a gate. Mnemonic A term, usually an abbreviation, that is easy to remember. Mode A selected method of operation. Example: run, test, or program. Modem A contraction of Modulator/Demodulator. Equipment that connects data terminal equipment to a communication line. Module An interchangeable, plug-in item containing electronic components
D-14
Page 434
Appendix D Glossary
Module Addressing A method of identifying the I/O modules installed in a chassis. Module Group Adjacent I/O modules which relate 16 I/O terminals to a single 16-bit image table word. Module Slot A location for installing an I/O module. Monitor (1) A CRT display. (2) To observe an operation. Monitoring Controller Used in an application where the process is continually checked to alert the operator of possible application malfunctions. Most Significant Bit (MSB) The bit representing the greatest value of a nibble, byte, or word. Most Significant Digit (MSD) The digit representing the greatest value of a byte or word. Motor Controller A device or group of devices that serve to govern, in a predetermined manner, the electrical power delivered to a motor. Motor Starter See Motor Controller. MSB See Most Significant Bit. MSD See Most Significant Bit. Multiple-Rung Display A feature that allows a number of rungs of program logic to be displayed simultaneously on the industrial terminal.
D-15
Page 435
Appendix D Glossary
N
National Bureau of Standards (NBS) An organization under the United States Department of Commerce responsible for developing and disseminating federal standards in many areas. National Electrical Code (NEC) A set of regulations governing the construction and installation of electrical wiring and apparatus, established by the National Fire Protection Association and suitable for mandatory application by governing bodies exercising legal jurisdiction. It is widely used by state and local authorities within the United States. NBS See National Bureau of Standards. NEC See National Electrical Code. NEMA Standards Consensus standards for electrical equipment approved by the members of the National Electrical Manufacturers Association (NEMA). NEMA Type 12 A category of industrial enclosures intended for indoor use to provide a degree of protection against dust, falling dirt, and dripping non-corrosive liquids. They do not provide protection against conditions such as internal condensation. Noise Unwanted disturbances imposed upon a signal that tend to obscure its data content. Noise Immunity The ability to function in the presence of noise. Noise Spike A noise disturbance of relatively short duration. Non-Volatile Memory A memory that is designed to retain its data while its power supply is turned off.
D-16
Page 436
Appendix D Glossary
O
Octal Numbering System A numbering system that uses only the digits 0 through 7. Also called base-8. Off Line Equipment or devices that are not connected to, or do not directly communicate with, the central processing unit. On Line Equipment or devices which communicate with the device it is connected to. Online Data Change Allows the user to change various data table values using a peripheral device while the application is operating normally. Online Editing Allows the user to modify a program using a peripheral device while the application is operating normally. One-Shot A programming technique which sets a storage bit or output bit for only one program scan. See Leading Edge One-Shot and Trailing Edge One-Shot. Open System A system that can be connected to other systems because of compliance to some established standard(s). Operating System A software system that controls the operation of a processor system by providing for input/output, allocation of memory space, or translation of programs. Output Information transferred from processor images table words through output modules to control output devices. Output Devices Devices such as solenoids and motor starters that receive data from the programmable controller.
D-17
Page 437
Appendix D Glossary
P
Parallel Operation A type of information transfer where all bits, bytes, or words are handled simultaneously. Parallel Output Simultaneous availability of two or more bits, channels, or digits. Parallel Transmission The simultaneous transmission of bits which constitute a character. Parity The use of a self-checking code employing binary digits in which the total number of ones is always even or odd. Parity Bit An additional bit added to a binary word to make the sum of the number of ones in a word always even or odd. Parity Check A check in which the parity bit is compared with a previously computed parity bit. Peripheral Equipment Units which communicate with the programmable controller, but are not part of the programmable controller. Example: a programming device or computer. PID Control See Proportional, Integral, Derivative Control. PR See Preset Value. Preset Value (PR) The number of time intervals or events to be counted. Pressure Switch A switch that is activated at a specified pressure. Process (1) Continuous and regular production executed in a definite uninterrupted manner. (2) One or more entities threaded together to perform a requested service. Processor The decision making data and storage sections of programmable controller.
D-18