Manual · Allen-Bradley
Mini-PLC-2/02, -2/16, -2/17 Processor (cat. no. 1772-LZ, LZP, LX, LXP, LW, LWP) User Manual
Manual490 pagesPDF 2.5 MB
User manual for the Allen-Bradley Mini-PLC-2/02, -2/16 and -2/17 processors (1772-LZ, LX, LXP, LW and related catalog numbers).
Covers · 1 model
The models it covers
Summary
What is in it
Allen-Bradley's procedure-oriented user manual for the series D Mini-PLC-2/02, Mini-PLC-2/16 and Mini-PLC-2/17 processors. It covers hardware features, installation step by step, start-up, maintenance and troubleshooting, memory organization and scan theory, then the full instruction set: relay-like, timers and counters, math and EAF functions, PID control, block transfer, bit shift registers, sequencers, timed interrupts and report generation, with specifications and a quick reference.
Its parts
- Using This Manual
- Fundamentals of a Programmable Controller
- Hardware Features
- Installing Your Programmable Controller
- Starting Your Processor
- Maintaining and Troubleshooting Your Processor
- Memory Organization
- Scan Theory
- Relay-Like Instructions
- Program Control Instructions
- Timers and Counters
- Data Manipulation and Compare Instructions
- Three-Digit Math Instructions
- EAF Math Instructions
- EAF Log, Trig, and FIFO Instructions
From the manual
Key facts from this manual
Each line names its page in the PDF.
Allen-Bradley user manual (publication 1772-6.5.8) for the series D Mini-PLC-2/02, Mini-PLC-2/16 and Mini-PLC-2/17 processors (1772-LZ, LZP, LX, LXP, LW and LWP). The 1772-LX and 1772-LXP are the Mini-PLC-2/16, without and with a built-in power supply. It covers hardware, installation, start-up, troubleshooting, the instruction set and specifications.
- Processor
- Mini-PLC-2/16: 1772-LX without a power supply, 1772-LXP with a power supply p. 410, 411
- Memory
- Mini-PLC-2/16: 4K words RAM, 4K words EEPROM backup p. 11, 410
- I/O capacity
- Mini-PLC-2/16: 256 p. 27
- Data table
- Mini-PLC-2/16: 48-3968 floating words p. 410
- Location
- Left-most slot of a 1771 I/O chassis p. 410
- Operating temperature
- 0 to 60 C (32 to 140 F), 5% to 95% relative humidity without condensation p. 410
- 1772-LXP power
- 1772-LXP: 120/220 V ac switch selectable, 97 to 132 or 194 to 264 V ac, 47 to 63 Hz, 96 VA p. 411
- 1772-LXP backplane output
- 1772-LXP: 4A output current to the backplane p. 411
- 1772-LX backplane load
- 1772-LX: 1.25 A backplane current requirement p. 410
- Battery
- 1770-XZ 3.6V lithium; maintains memory for 1 year with no AC applied p. 33, 410
- Programming port
- 15 pin INTFC socket for a 1770-T3 or 1784-T50 terminal, 1770-RG, 1770-T11, 1772-KG or 1771-KA p. 33
- Cables
- 1772-TC for the 1770-T3; 1772-TC or 1784-CP2 for the 1784-T50; 1771-CN, -CO or -CR for Data Highway p. 33
- Scan times
- I/O scan 0.82 ms (2-slot), 2.00 ms (1-slot), 2.15 ms (1/2-slot); program scan 7.5 ms/K minimum p. 410
- I/O chassis
- 1771-A1B, -A2B, -A3B, -A3B1, -A4B p. 40
What this manual walks you through
- Hardware needed to install the processor system p. 40
- Planning location, cooling and spacing in the enclosure p. 41
- Choosing the operating mode with the key switch p. 31, 32
- Backing up the program to EEPROM with MEM STORE p. 32
- Connecting a 1770-T3 industrial terminal p. 34, 35, 36
- Preventive maintenance of connections p. 104
- Troubleshooting with the PROC indicator p. 106
Good to know
- Programs entered with a 1770-T3 must not be edited with a 1770-T1 or 1770-T2 terminal. p. 34
- Cooling air immediately below the processor must not exceed 60 C (140 F). p. 41
- Use the main disconnect switch, never the ac line fuse, to cycle or remove line power. p. 105
- The processor fuse has no visual indicator; with a blown fuse the processor appears dead. p. 106
- A hardware failure trips the watchdog after 250 milliseconds, lights the red PROC indicator and needs a power cycle to clear. p. 106
Questions this manual answers
What is the difference between the 1772-LX and 1772-LXP?
Both are the Mini-PLC-2/16 processor; the 1772-LX has no power supply and the 1772-LXP has a self-contained 120/220 V ac power supply. p. 27, 410, 411
How much memory does the Mini-PLC-2/16 have?
4K words of RAM with a 48-3968 word floating data table. p. 11, 410
What battery does the 1772-LX use?
The 1770-XZ 3.6V lithium battery, which maintains memory for 1 year with no AC applied. p. 33, 410
What does a red PROC light mean on a Mini-PLC-2/16?
A possible hardware failure: the program is not executing. The manual says to cycle power and call an A-B representative if it persists. p. 106
How many I/O does the Mini-PLC-2/16 support?
The manual gives an I/O capacity of 256 for the Mini-PLC-2/16. p. 27
Contents
Chapters and sections
Each line opens the PDF at its page.
- 1772-6.5.8, Mini-PLC-2/02, -2/16, -2/17 Processor, User Manual1
- Important User Information2
- Summary of Changes3
- 1 - Using This Manual11
- 2 - Fundamentals of a Programmable Controller15
- 3 - Hardware Features27
- 4 - Installing Your Programmable Controller40
- 5 - Starting Your Processor83
- 6 - Maintaining and Troubleshooting Your Processor104
- 7 - Memory Organization107
- 8 - Scan Theory119
- 9 - Relay-Like Instructions127
- 10 - Program Control Instructions138
- 11 - Timers and Counters146
- 12 - Data Manipulation and Compare Instructions156
- 13 - Three-Digit Math Instructions169
- 14 - EAF Math Instructions173
- 15 - EAF Log, Trig, and FIFO Instructions194
- 16 - EAF Process Control Instructions212
- 17 - Jump Instructions and Subroutines260
- 18 - Block Transfer266
- 19 - Data Transfer Instructions293
- 20 - Bit Shift Registers311
- 21 - Sequencers325
- 22 - Selectable Timer Interrupts348
- 23 - Report Generation352
- 24 - Program Editing374
- 25 - Programming Techniques391
- 26 - Program Troubleshooting400
- A - Specifications410
- B - Processor Comparison Chart412
- C - Number Systems414
- D - Glossary420
- E - Quick Reference445
- Index480
- Back Cover490
The whole text · 59 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 31-3
- Table of Contents4-10
- 1 - Using This Manual11-14
- 2 - Fundamentals of a Programmable Controller15-26
- 3 - Hardware Features27-39
- 4 - Installing Your Programmable Controller, pages 40 to 4840-48
- 4 - Installing Your Programmable Controller, pages 49 to 5749-57
- 4 - Installing Your Programmable Controller, pages 58 to 6658-66
- 4 - Installing Your Programmable Controller, pages 67 to 7567-75
- 4 - Installing Your Programmable Controller, pages 76 to 8276-82
- 5 - Starting Your Processor, pages 83 to 8983-89
- 5 - Starting Your Processor, pages 90 to 9690-96
- 5 - Starting Your Processor, pages 97 to 10397-103
- 6 - Maintaining and Troubleshooting Your Processor104-106
- 7 - Memory Organization107-118
- 8 - Scan Theory119-126
- 9 - Relay-Like Instructions127-137
- 10 - Program Control Instructions138-145
- 11 - Timers and Counters146-155
- 12 - Data Manipulation and Compare Instructions156-168
- 13 - Three-Digit Math Instructions169-172
- 14 - EAF Math Instructions, pages 173 to 179173-179
- 14 - EAF Math Instructions, pages 180 to 186180-186
- 14 - EAF Math Instructions, pages 187 to 193187-193
- 15 - EAF Log, Trig, and FIFO Instructions, pages 194 to 202194-202
- 15 - EAF Log, Trig, and FIFO Instructions, pages 203 to 211203-211
- 16 - EAF Process Control Instructions, pages 212 to 221212-221
- 16 - EAF Process Control Instructions, pages 222 to 231222-231
- 16 - EAF Process Control Instructions, pages 232 to 241232-241
- 16 - EAF Process Control Instructions, pages 242 to 251242-251
- 16 - EAF Process Control Instructions, pages 252 to 259252-259
- 17 - Jump Instructions and Subroutines260-265
- 18 - Block Transfer, pages 266 to 274266-274
- 18 - Block Transfer, pages 275 to 283275-283
- 18 - Block Transfer, pages 284 to 292284-292
- 19 - Data Transfer Instructions, pages 293 to 301293-301
- 19 - Data Transfer Instructions, pages 302 to 310302-310
- 20 - Bit Shift Registers311-324
- 21 - Sequencers, pages 325 to 332325-332
- 21 - Sequencers, pages 333 to 340333-340
- 21 - Sequencers, pages 341 to 347341-347
- 22 - Selectable Timer Interrupts348-351
- 23 - Report Generation, pages 352 to 359352-359
- 23 - Report Generation, pages 360 to 367360-367
- 23 - Report Generation, pages 368 to 373368-373
- 24 - Program Editing, pages 374 to 382374-382
- 24 - Program Editing, pages 383 to 390383-390
- 25 - Programming Techniques391-399
- 26 - Program Troubleshooting400-409
- Pages 410 to 413410-413
- C - Number Systems414-419
- D - Glossary, pages 420 to 428420-428
- D - Glossary, pages 429 to 437429-437
- D - Glossary, pages 438 to 444438-444
- E - Quick Reference, pages 445 to 453445-453
- E - Quick Reference, pages 454 to 462454-462
- E - Quick Reference, pages 463 to 471463-471
- E - Quick Reference, pages 472 to 479472-479
- Pages 480 to 490480-490
The file




