Page 161

Appendix B Design Worksheets

Chassis Number: _________________ Indicate Chassis Size:

Processor

Identify Groups and I/O Points:

List Current Required for Each Module in this Chassis:

2-slot

Addressing Mode:

1771-A1B 4-slot chassis

1771-A2B 8-slot chassis

1771-A3B, or 1771-A3B1 12-slot chassis

Complementary I/O?

or Adapter

1-slot

R___

R___

R___

R___

R___

Slot 1 G ___ 00-07 10-17 G __ 00-07 10-17

Slot 2 G ___ 00-07 10-17 G __ 00-07 10-17

Slot 3 G ___ 00-07 10-17 G __ 00-07 10-17

Slot 4 G ___ 00-07 10-17 G __ 00-07 10-17

Slot 5 G ___ 00-07 10-17 G __ 00-07 10-17

Slot 9 G ___ 00-07 10-17 G __ 00-07 10-17

Slot 10 G ___ 00-07 10-17 G __ 00-07 10-17

Slot 11 G ___ 00-07 10-17 G __ 00-07 10-17

Slot 12 G ___ 00-07 10-17 G __ 00-07 10-17

____

____

____

____

____

____

1/2-slot

1771-A4B 16-slot chassis

Yes, chassis______ R___

No

R___

R___

Slot 6 G ___ 00-07 10-17 G __ 00-07 10-17

Slot 7 G ___ 00-07 10-17 G __ 00-07 10-17

Slot 8 G ___ 00-07 10-17 G __ 00-07 10-17

Slot 13 G ___ 00-07 10-17 G __ 00-07 10-17

Slot 14 G ___ 00-07 10-17 G __ 00-07 10-17

Slot 15 G ___ 00-07 10-17 G __ 00-07 10-17

Slot 16 G ___ 00-07 10-17 G __ 00-07 10-17

____

____

____

____

____

____

____

____

____

____

Total Current Draw for I/O Modules in this Chassis = _____

B-11

Page 162

Appendix B Design Worksheets

Select Adapter Modules

BOM

For more information on:

See:

Selecting the I/O adapter modules

Classic 1785 PLC-5 Programmable Controllers User Manual, publication 1785-6.2.1, Chapter 2: Selecting I/O Adapter Modules

17. In column A of the table below, indicate the chassis number in which you will place each adapter module. 18. In column B, indicate the name/type of each adapter module. 19. In column C, list any special requirements for the adapter module. 20. In column D, indicate the current draw requirements for the adapter module. A Chassis Number

B-12

B Adapter Module

C Special Requirements

D Current Draw

Page 163

Appendix B Design Worksheets

21. In the table below, list any device other than an adapter module that you are connecting to a remote I/O link, list its chassis number, and list any special requirements. For example: PLC-5 processor in adapter mode PLC-5/250 remote scanner in adapter mode PLC interface module for digital ac and dc drives Remote I/O adapter for Bulletin 1336 drives RediPANEL pushbutton and keypad modules Dataliner PanelView (see operator interface) Option module (for T30 plant-floor terminal) 8600 CNC with remote I/O adapter option CVIM in adapter mode Pro-Spec 6000 Fastening System with remote I/O adapter option 1747-DCM module (to SLC-500 rack) 1771-DCM module 1771-GMF robot (remote I/O interface module)

Device

Attached to Chassis Number

Special Requirements

B-13

Page 164

Appendix B Design Worksheets

Place System Hardware

For more information on:

See:

Determining proper environment Enclosures Raceway layout Cabling and wiring Mounting Grounding

Classic PLC-5 Programmable Controllers User Manual, publication 1785-6.2.1, Chapter 3: Determining the Proper Environment Protecting Your Processor Laying Out Your Cable Raceway Planning Cabling Laying Out the Backpanel Spacing Grounding Configuration

Sketch a layout of your system that indicates the following: proper environment enclosures mounting raceway layout cabling and wiring grounding

B-14

Page 165

Appendix B Design Worksheets

Configure Switch Settings

For more information on:

See:

Configuring switches

Classic PLC-5 Programmable Controllers User Manual, publication 1785-6.2.1, Appendix A

Record switch setting choices on a copy of this worksheet. You might need to return to the worksheet several times as you complete your system design. 1.

Locate the chassis configuration plug (between the first two left most slots of the chassis).

2.

Set the I/O chassis configuration plug.

Y N

USING POWER SUPPLY MODULE IN THE CHASSIS?

Y N

The default setting is N (not using a power supply module in the chassis).

Y N

Set Y when you install a power supply module in the chassis.

IMPORTANT: You cannot power a single I/O chassis with both a power supply module and an external power supply.

Set N when you use an external power supply.

17075

Rack 0 Chassis and Processor Switch Settings For PLC-5/10, -5/12, -5/15, -5/25 processors: Processor Chassis Back Plane Switches Rack 0

Notes:

O 1 N O F F

2

3

4

5

6

OFF 7

8

Processor Module Switch SW1 O 1 F F O N

2

3

4

5

ON 6

7

8

Processor Module Switch SW2 O 1 F F O N

2

3

4

5

Processor Module Switch SW3

ON 6

7

8

O F F O N

1

2

3

ON

4

Switches shown in black are not used, but they must be set to the positions indicated.

B-15

Page 166

Appendix B Design Worksheets

Chassis and Adapter Switch Settings for Remote I/O OFF I/O Chassis Back Plane Switches Rack______

O 1 N O F F

2

3

4

5

6

7

8

O 1 N O F F

I/O Chassis Back Plane Switches Rack______

O 1 N O F F

2

3

4

5

6

O 1 N O F F

2

3

4

5

6

7

8

O 1 N O F F

O 1 N O F F

2

3

4

5

6

7

8

O 1 N O F F

O 1 N O F F

2

3

4

5

6

7

8

O 1 N O F F

O 1 N O F F

2

3

4

5

6

7

8

O 1 N O F F

O 1 N O F F

2

3

4

5

6

6

7

8

2

3

4

5

2

3

4

5

2

3

4

5

2

3

4

5

7

8

O 1 N O F F

2

3

4

5

6

7

8

8

O 1 N O F F

2

3

4

5

1

2

3

O N O F F

1

2

3

6

7

8

O N O F F

1

2

3

6

7

8

O N O F F

1

2

3

OR

6

7

8

O N O F F

1

2

3

Adapter Module Switch SW2 Series B 6

7

8

O N O F F

1

2

3

4

Adapter Module Switch SW2 Series B 6

7

8

O N O F F

1

2

3

4

OR

5

6

2

3

4

5

6

2

3

4

5

6

2

3

4

5

6

Adapter Module Switch SW2 Series C O 1 N O F F

4

4

Adapter Module Switch SW2 Series C O 1 N O F F

4

3

Adapter Module Switch SW2 Series C O 1 N O F F

4

2

Adapter Module Switch SW2 Series C O 1 N O F F

OR Adapter Module Switch SW2 Series B

Note: Switches previously marked in black are not used, but must be set to the positions indicated.

B-16

OR

4

Adapter Module Switch SW2 Series B

Adapter Module Switch SW2 Series C O 1 N O F F

4

OR Adapter Module Switch SW2 Series B

Adapter Module Switch SW1 7

O N O F F

Adapter Module Switch SW2 Series B

Adapter Module Switch SW1

I/O Chassis Back Plane Switches Rack______

5

Adapter Module Switch SW1

I/O Chassis Back Plane Switches Rack______

4

Adapter Module Switch SW1

I/O Chassis Back Plane Switches Rack______

3

Adapter Module Switch SW1

I/O Chassis Back Plane Switches Rack______

2

Adapter Module Switch SW1

I/O Chassis Back Plane Switches Rack______

Adapter Module Switch SW2 Series B

Adapter Module Switch SW1

OR

2

3

4

5

6

Adapter Module Switch SW2 Series C O 1 N O F F

2

3

4

5

6

Adapter Module Switch SW2 Series C O 1 N O F F

2

3

4

5

6

Page 167

Appendix B Design Worksheets

Determine Communication Requirements

BOM

For more information on:

See:

Identifying processor connectors/channels Configuring Channel 0 (serial ASCII port) Choosing a DH+ link

Classic 1785 PLC-5 Programmable Controllers User Manual, publication 1785-6.2.1, Chapter 5: Identifying Classic PLC-5 Processor Channels/Connectors Using Channel 0 Configuring a DH+ Link

Selecting DH+ cabling, layout Selecting processor connectors/channels cabling

Classic 1785 PLC-5 Programmable Controllers Design Manual, publication 1785-6.2.1, Chapter 3: Laying Out Your Cable Raceway Planning Cabling

Selecting termination resistors

Classic PLC-5 Programmable Controllers Design Manual, publication 1785-6.2.1, Chapter 2: Selecting Link Terminators

Defining DH+ station addresses

Classic PLC-5 Family Programmable Controller Hardware Installation Manual, publication 1785-6.6.1

1.

Make a copy of appropriate pages of this worksheet for each of your processors.

2.

Identify communication modes and network selections.

3.

Indicate channel configurations and DH+ station addresses.

4.

List racks attached to each channel/connector configured for remote I/O scanner or adapter mode.

5.

Identify DH+ link cable layout (daisy chain or trunkline/dropline).

B-17

Page 168

Appendix B Design Worksheets

6.

Select your data link cables. Circle or highlight your selections in the following tables.

for remote I/O link for Ethernet link

With this transmission rate:

Select this maximum cable length (1770-CD cable):

57.6 kbaud

10,000 ft

115.2 kbaud

5,000 ft

230.4 kbaud

2,500 ft

If you need this:

Select this catalog number:

Thick-wire 2.0 m (6.5 ft) transceiver cable

5810-TC02/A

Thick-wire 15.0 m (49.2 ft) transceiver cable

5810-TC15/A

Thin-wire transceiver, and 2.0 m (6.5 ft) cable

5810-TAS/A (kit)

Thin-wire transceiver, and 15.0 m (49.2 ft) cable

5810-TAM/A (kit)

Thick-wire transceiver, and 2.0 m (6.5 ft) cable

5810-TBS/A (kit)

Thick-wire transceiver, and 15.0 m (49.2 ft) cable 5810-TBM/A (kit)

7.

B-18

Terminate a DH+ or remote I/O link by setting switch assembly 3.

Page 169

Appendix B Design Worksheets

PLC-5/10 Processor

BATT

COMM FAULT

PROC ACTIVE RUN FO RCE REM

R U N

P R O G

List information:

BATTERY IN S T A L L E D

PEER COMM IN T F C

List local rack numbers:

1 SH 2

PEER COMM IN T F C

PLC-5/10 PROGRAMMABLE CONTROLLER

DH+ Station Address _______________

Record any additional information about your communication mode and network selection.

B-19

Page 170

Appendix B Design Worksheets

PLC-5/12, -5/15, or -5/25 Processor

SW1 settings Scanner Adapter SW2 rack address setting First I/O group Number of words to transfer

BATT

COMM FAULT

PROC R E M I/O ACTIVE RUN FORCE ADPT REM

R U N

P R O G

List information:

BATTERY IN S T A L L E D

DH+

List rack numbers (if configured for scanner):

DH+ Station Address _______________

1 SH 2

DH+

1 SH 2

REM I/O

PLC-5/25 PROGRAMMABLE CONTROLLER

Record any additional information about your communication mode and network selection.

B-20