Page 151

Appendix

B

Design Worksheets

Conventions Used in These Worksheets

The following symbols are printed in the top left corner of the worksheets. The symbols indicate whether programmers or installers will need the completed worksheets. Use the symbols as a way of organizing the completed worksheets for the appropriate user.

indicates a worksheet that provides information for a programmer indicates a worksheet that provides information for an installer

BOM indicates a worksheet that provides information for a bill of materials (BOM)

Important: You may need to make multiple copies of some worksheets to record all of your system requirements.

B-1

Page 152

Appendix B Design Worksheets

Prepare a Functional Specification

For more information on:

See:

Functional specifications

Classic 1785 PLC-5 Programmable Controllers User Manual, publication 1785-6.2.1, Chapter 1: Designing Systems Preparing Your Functional Specification

1.

Divide your manufacturing process into functional areas.

2.

Make a copy of the reverse side of this worksheet for each functional area.

3.

For each functional area, document the following: Information to Document

4.

B-2

Example(s)

Inputs

Actions and signals, ranges, quantities, timing, tolerance, units of measure, validation requirements, possible errors, and error responses

Outputs

Quantities, units of measure, timing, tolerances, ranges, validation methods, method or reporting invalid outputs, locations, methods of data output, physical requirements

Performance requirements

Accuracy; maximum and minimum transition times; interface timing; operator response timing; adherence to standards such as IEEE, ANSI

Interfaces

Operator, software, hardware

Failure modes and recovery methods

Fault routines

Security requirements

Operator access, alarming, etc.

Maintenance requirements

Documentation, spare parts, accessibility

Use the information on these worksheets to develop a complete functional specification.

Page 153

Appendix B Design Worksheets

Functional Area:

Inputs:

Outputs:

Performance Requirements:

Interfaces:

Failure Modes and Recovery Methods:

Security Requirements:

Maintenance Requirements:

B-3

Page 154

Appendix B Design Worksheets

Determine Control Strategy

For more information on:

See:

Control strategy Remote I/O scanner mode Extended-local I/O scanner mode Remote I/O adapter mode

Classic 1785 PLC-5 Programmable Controllers User Manual, publication 1785-6.2.1, Chapter 1: Designing Systems Using the Classic PLC-5 Processor as a Remote I/O Scanner Using the Classic PLC-5 Processor as a Remote I/O Adapter

Choosing communication

1.

Classic 1785 PLC-5 Programmable Controllers Design Manual, publication 1785-6.2.1, Chapter 5

Answer the following questions when you begin planning your control strategy: What will be controlled together?

What will be controlled separately?

Will control devices communicate as peers (network) or in a hierarchy (master/slave)?

B-4

Page 155

Appendix B Design Worksheets

What will be controlled via a remote I/O link?

Which processes will be controlled by a classic 1785 PLC-5 processor?

What are the environmental and safety concerns for your system?

2.

Use text and illustrations to lay out and describe your strategy.

B-5

Page 156

Appendix B Design Worksheets

Identify Chassis Locations

1.

Make a copy of this worksheet for each of your functional areas.

2.

For each functional area, determine the number of chassis by using the table below. Functional Area: Category Each functional area requires at least one chassis.

Number of Chassis 1

Add an additional chassis for each case where I/O at this functional area require different: power disconnects ac phases logical or functional groupings Total chassis for this functional area:

3.

B-6

Assign a unique chassis number to each of the chassis, and record all assigned numbers below. Chassis ______________

Chassis ______________

Chassis ______________

Chassis ______________

Chassis ______________

Chassis ______________

Chassis ______________

Chassis ______________

Chassis ______________

Chassis ______________

Chassis ______________

Chassis ______________

Chassis ______________

Chassis ______________

Chassis ______________

Chassis ______________

Chassis ______________

Chassis ______________

Page 157

Appendix B Design Worksheets

BOM

Select Module Types and List I/O Points

For more information on:

See:

Selecting I/O modules Selecting I/O points

Classic 1785 PLC-5 Programmable Controllers User Manual, publication 1785-6.2.1, Chapter 2: Selecting I/O Modules Selecting I/O Adapter Modules

I/O module catalog numbers

Automation Products Catalog, publication AP 100, Section 3: Input/Output

1.

Make a copy of the reverse side of this worksheet for each of your chassis.

2.

For each chassis, list each discrete, analog, and specialty I/O module and its electrical characteristics. Use the table below to determine which characteristics to list. If you choose this type of I/O module:

List these characteristics:

Discrete input module

Voltage Special requirements: - Isolation - Proximity switch - Source or sink - Fast response - TTL

Discrete output module

Voltage Current Special requirements: - Isolation - Protection (detection of failed triacs) - TTL - High current switching

Analog input module

Voltage or current range Resolution required Single-ended or differential Special requirements - Thermocouple - RTD - Isolation

Analog output module

Voltage or current range Resolution required Special requirements: - PID - Isolation

Specialty or communication I/O modules (including block I/O modules)

Voltage or current range Resolution required Noise/distance limits Single-ended or differential Special requirements - Thermocouple - RTD - PID - Isolation

B-7

Page 158

Appendix B Design Worksheets

Chassis Number: _____________________ Input or I/O Module Type Output

B-8

I/O Module Catalog Number

Time Critical Yes / No

Voltage or Range

Current or Range

Number of Points

Required Resolution (analog only)

Single-Ended or Differential (analog only)

Special Requirements

Page 159

Appendix B Design Worksheets

Total I/O Module Requirements

BOM

1.

Make a copy of this worksheet for each of your chassis.

2.

For each of the I/O modules identified on the chassis’ Select Module Types and List I/O Points worksheet on pages 7 and 8, perform the following steps to determine the total number that you need. 3.

In column A, list the module’s catalog number.

4.

In column B, total the number of I/O points for the module.

5.

In column C, enter the maximum number of I/O points available per module.

6.

In column D, calculate the total number of these modules that you will need for this chassis by dividing column B by column C.

7.

In column E, enter the number of spare modules that you may need for future expansion of this chassis.

8.

In column F, enter the total number of these modules that you need for this chassis.

Chassis Number: _________________ A I/O Module Cat. No.

B Total I/O Points

C I/O Points / Module

D E I/O Modules Required Spare I/O modules (B / C)

F Total I/O modules

B-9

Page 160

Appendix B Design Worksheets

Assign I/O Modules to Chassis and Assign Addresses

BOM

For more information on:

See:

Assigning I/O modules to chassis Selecting addressing mode Assigning addresses Addressing complementary I/O

Classic 1785 PLC-5 Programmable Controllers User Manual, publication 1785-6.2.1, Chapter 4: Placing I/O Modules in Chassis Choosing the Addressing Mode Assigning Racks Addressing Complementary I/O

Selecting the I/O chassis

Classic 1785 PLC-5 Programmable Controllers Design Manual, publication 1785-6.2.1, Chapter 2: Selecting I/O Chassis

Current requirements to I/O modules

Automation Products Catalog, publication AP 100, Section 3: Input/Output

9.

Make a copy of the reverse side of this worksheet for each of your chassis, and use it to record your responses to items 2 through 8.

10. Indicate the addressing mode for each chassis. Use the table below to guide your selection. If the densest I/O module in the chassis is:

And you want to:

8-point

Then choose: 2-slot addressing

16-point 32-point

Assign any mix of modules in adjacent module slots

1-slot addressing

Make full use of I/O capacity

2-slot addressing

Assign any mix of modules in adjacent module slots

1/2-slot addressing

Make full use of I/O capacity

1-slot addressing

11. Indicate the chassis size. Use the table below to guide your selection. If you need to: Reduce spare parts

Fit space requirements

And are:

Then consider:

Expanding your system

Standard size you now use

Installing a new system

One size using the guidelines listed below

Limited to 9 inches

4-slot chassis

Limited to 14 inches

8-slot chassis

Limited to 19 inches

12-slot chassis

Limited to 24 inches

16-slot chassis

Minimize scan time Minimize cost per slot Accommodate expansion

Largest chassis containing processor Largest chassis consistent with decisions above

12. Indicate whether a processor or an adapter is in the left-most slot. 13. Indicate whether you are using this chassis for complementary I/O. 14. Write the module type in each available slot on the chassis diagram. 15. Assign rack numbers, group numbers, and number of points per group. 16. Indicate the current requirement for each module.

B-10