Control and Load Switch Specifications, Bulletin Number 194E, 194L, pages 13 to 26
Pages 13 to 26 of 26: 194L Control and Load Switches; Back Cover
The original document is the PDF (2.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 194L
Page 13
Specifications
194L Control and Load Switches
Switching Diagrams Contact target tables: X = Contact Closed [Blank] = Contact Open
Circuit Diagram Nos. 1501…4253
Rockwell Automation Publication 194-TD002B-EN-P
13
Page 14
194L Control and Load Switches
Specifications
Circuit Diagram Nos. 4271…5531
14
Rockwell Automation Publication 194-TD002B-EN-P
Page 15
Specifications
194L Control and Load Switches
Circuit Diagram Nos. 5012…5272
Rockwell Automation Publication 194-TD002B-EN-P
15
Page 16
194L Control and Load Switches
Specifications
Circuit Diagram Nos. 5273…8771
16
Rockwell Automation Publication 194-TD002B-EN-P
Page 17
Specifications
194L Control and Load Switches
Electrical Ratings Performance Data IEC Applications Rated voltage Ue
IEC-947
[V]
12 A
16 A
20 A
25 A
32 A
40 A
690
690
690
690
690
690
Isolating conditions acc. to VDE fulfilled up to rated impulse voltage Uimp
[kV]
6
6
6
6
8
8
Thermal rated current
40 °C IEC-947
[A]
16
20
25
30
32
45
Thermal rated current Ithe
60 °C IEC-947
[A]
12
16
20
25
32
45
Rated current Non-inductive or slightly inductive loads/ switching of resistive loads with slight overload Non-inductive or slightly AC-1 inductive loads Switching of mixed resistive AC22A and inductive loads with slight overload Switching of inductive drives, AC-15 motors, valves, and electromagnets. DC switching capacity Rated current Ie
AC-1/ AC-21A
Rated Voltage [V]
DC-21A
For resistive loads, T ≤ 1ms Ue max = 600V
IEC-947
690V
[A]
12
16
20
25
32
40
SEV
660V
[A]
12
16
20
25
32
40
IEC-947
220…500V 690V
[A] [A]
12 12
16 16
20 20
25 25
32 32
40 40
IEC-947
220…240V 380…415V 500V
[A] [A] [A]
5 3 2
6 4 2.5
7 5 3
8 6 4, - Contacts in series 1 24 48 60 110 220
2 48 96 120 220 440
3 72 144 180 330 660
4 96 192 240 440, 5 120 240 300 550, 6 144 288 360 660, 8 192 384 450, - [A] [A] [A] [A] [A]
12 10 8 2 0.5
16 12 10 2.5 0.6
20 16 12 4 0.7
22 18 14 5 0.8, - 32, - - - 40, - 440, - - - - - [A]
0.4
0.4
0.5
0.5, - 25.2 50.4
50.4 75.6 100.8 126 100.8 151.2 201.6 252
151.2 201.6 302.4 403.2
[A] [A]
18 15
24 21
30 24
33 27, - - - 63
126
60
Rated making/breaking capacity (= 1.5 x Ie) 1.05 x Rated voltage [V] For resistive loads, T Ith 1ms
378
504
[A]
12
18
18
21
48
115.5 231
346.5 462
577.5, - [A]
3
4.5
6
7.5, - 231
462, - - - - [A] 0.75
1.12
1.05
1.2, - 462, - - - - - [A] 0.52
0.78
0.47
0.75, - 24 30 48 60 110 220
48 60 96 120 220, 72 90 144 180 330, 96 120 192 240 440, 120 150 240 300 550, 144 180 288 360 660, 192 240 384 450, - [A] [A] [A] [A] [A] [A]
8 4.5 1.5 1 0.4, 10 5.5 2 1.2 0.5, 12 7 2.5 1.5 0.6, 14 8 3 1.8 0.7, 16, 8 4.8 2 0.6
16, 8 4.8 2 0.6
1.1 x Rated voltage [V]
26.4 33
52.8 66
79.2 99
105.6 132 132 165
158.4 184.8 198 231
[A] 8.8 [A] 4.95
11 6.05
13.2 7.7
1.54 8.8, - For inductive loads T = 50 ms
52.8
105.6 158.4 211.2 264
316.8 369.6
[A] 1.65
2.2
2.75
3.3
8.8
17.6, 8.8
Ue max = 600V
66
132
198
264
330
396
462
[A]
1.1
1.32
1.65
1.98
5.28
121
242
363
484
605, - [A] 4.95 [W] 0.3
6.05 0.5
7.7 0.6
8.8 0.9
2.2 0.8
2.2 1.4
[kW] [kW] [kW] [kW] [kW] [kW] [kW] [kW] [kW] [kW]
0.15 0.25 0.30 0.37 0.30 0.50 0.75 1.20 0.50 1.20
0.20 0.30 0.37 0.50 0.37 0.75 1.00 1.40 0.75 1.40
0.25 0.37 0.50 0.75 0.50 1.00 1.20 1.60 1.00 1.50
0.30, 0.50, 1.00, - - - - 0.30, 0.50, 1.00, - - - - Ue max = 600V
189
252
315
Rated current Ie Rated voltage [V] For inductive loads T = 50 ms Rated voltage [V]
Rated making/breaking capacity (= 1.1 x Ie)
Power Lost Rated power Pe
Rated voltage [V] DC-23A, DC-3, DC-5 For inductive loads, T ≤1 ms
5.28
Contacts in series 24 24 48 48 60 60 110 110 220 220
1 2 2 3 2 4 4 6 4 6
0.12 0.20 0.25 0.30 0.25 0.37 0.50 1.00 0.37 1.00 standards compliance listed on http://ab.rockwellautomation.com/Circuit-and-Load-Protection/Disconnect-Switches/Non-Visible-Blade/194R-Fused-NonFused-Disconnect-Switches#specifications
Rockwell Automation Publication 194-TD002B-EN-P
17
Page 18
194L Control and Load Switches
Specifications
Performance Data, Continued
12 A
16 A
20 A
25 A
32 A
40 A
IEC Applications, Continued Rated making/breaking capacity (= 4 x Ie) DC-23A, DC-3, DC-5 For inductive loads, T ≤ 7.5 ms
Contacts in series
Rated Voltage [V] 25.2 25.2 50.4 50.4 63 63 115.5 115.5 231 231
1 2 2 3 2 4 4 6 4 6
[A] [A] [A] [A] [A] [A] [A] [A] [A] [A]
20.0 33.3 21.0 25.0 16.6 24.6 18.1 36.4 6.7 18.1
25.0 41.6 25.0 30.8 20.0 33.3 27.2 43.6 9.1 21.8
33.3 50.0 30.8 42.0 24.6 50.0 36.4 51.0 13.6 25.2
41.6 61.6 41.6 62.4 33.2 66.4 44.0 58.2 18.2 27.2
50.0, 41.6, 66.6, - - - - 50.0, 41.6, 66.6, - - - - at 220V 0.45 [cos j] at 380V 0.45 [cos j] at 660V 0.45[cos j]
[A]
72
96
128
176
296
296
[A]
72
96
128
176
280
336
[A]
53
72
86
112
196
196
240V 380V 415V 440V 500V 660V
[kW] [kW] [kW] [kW] [kW] [kW]
3 5.5 5.5 5.5 7.5 7.5
4 7.5 7.5 7.5 10 10
5.5 9 9 9 11 11
5.5 13 13 13 15 15, - - - - - - - - - - - 220…240V 380…440V 500V 660V
[kW] [kW] [kW] [kW]
2.2 4 5.5 5.5
3 5.5 7.5 7.5
4.5 7.5 10 8
5.5 11 13 11
7.5 15, 18.5
7.5 18.5, 18.5
110V 220…240V 380…440V
[kW] [kW] [kW]
0.75 1.3 2.2
1.1 2.2 3.7
1.2 2.5 4.5
1.6 3.2 5.5, 4 8, 4 16
3-phase 3-pole
220…240V 380…415V 440…550V
[kW] [kW] [kW]
0.75 1.5 1.5
1.5 2.2 2.2
3 3.7 3.7
4 5.5 5.5
5.5 7.5 7.5
5.5 7.5 11
1-phase 2-pole
110V 240V 380V 440V
[kW] [kW] [kW] [kW]
0.18 0.37 0.75 0.75
0.37 0.75 1.1 1.1
0.55 1.5 1.8 1.8
0.75 2.2 3 3, - - - - - - - Rated breaking capacity
Rated power
AC-2
IEC-947
Slip-ring motors: starting, reversing and electric braking; star/delta starting
3-phase 3-pole
IEC-947
AC-3
3-phase Squirrel-cage motors: starting and stopping 3-pole of running motors 1-phase 2-pole IEC-947
AC-4
Squirrel-cage motors: starting, reversing, electric braking, inching standards compliance listed on http://ab.rockwellautomation.com/Circuit-and-Load-Protection/Disconnect-Switches/Non-Visible-Blade/194R-Fused-NonFused-Disconnect-Switches#specifications
18
Rockwell Automation Publication 194-TD002B-EN-P
Page 19
Specifications
194L Control and Load Switches
Performance Data, Continued
12 A
16 A
20 A
25 A
32 A
40 A
IEC Applications, Continued
AC-23A
Occasional switching of motors and other highly inductive loads (criterion for selecting main switches)
IEC-947 3-phase 3-pole
220…240V 380…440V 500V 660V
[kW] [kW] [kW] [kW]
2.2 4 5.5 5.5
3 5.5 7.5 7.5
4.5 7.5 10 8
5.5 11 13 11
11 18.5, 22
11 22, 22
1-phase 2-pole
110V 220…240V 380…440V
[kW] [kW] [kW]
0.75 1.3 2.2
1.1 2.2 3.7
1.2 2.5 4.5
1.6 3.2 5.5, 5.5 11, 5.5 11
[kArms] [A]
0.48
0.48
0.6
0.75
0.8 35
0.8 40
[kA]
6
6
5
5
5
5
[ops/h]
120
120
120
120
120
120
Short-circuit ratings Rated short-time current (1s) Strongest series fuse, not in (gL characteristic) enclosure Conditional rated shortcircuit Switch Rate electrical
CSA and UL Applications Rated Voltage Ue Ampere Rating Rated power Pe§
600
600
600
600
600
600
[A]
A600 12
A600 16, 20, 25, 32, 40
(FLA)
(FLA)
(FLA)
(FLA)
3-phase 3-pole
120V 240V 480V 600V
[Hp] [Hp] [Hp] [Hp]
1 (7.2) 2 (6.8) 5 (7.6) 5 (6.1)
1.5 (12) 3 (9.6) 7.5 (11) 7.5 (9)
2 (13.6) 4 (12.4) 8 (11.6) 10 (11)
3 (19.2) 6 (18) 12 (17) 15 (17)
5 (30.4) 7.5 (22) 20 (27) 20 (22)
5 (30.4) 10 (28) 25 (34) 25 (27)
1-phase 2-pole
120V 240V 480V 600V
[Hp] 0.5 (9.8) .75 (13.8) [Hp] 1 (8.0) 1.5 (10.0) [Hp] 2 (6.0) 3 (8.5) [Hp] 3 (6.8) 3 (6.8)
1 (16) 2 (12) 4 (11.2) 5 (11.2)
1.5 (20) 3 (17) 6 (17) 7.5 (16)
2 (24) 5 (28) 7.5 (21) 10 (20)
2 (24) 5 (28) 10 (26) 15 (27)
120V 240V
[Hp] [Hp] [A], - 35, - 55, - 60, - 80
[kA]
5
5
5
5
120
120
UL (CSA)
Standard motor DOL rating (similar to AC-3)
Heavy motor load, reversing Rating (similar to AC-4) Max. back-up fuse Short Circuit Ratings
[V AC] Pilot Duty Contact class General Use Non-inductive or slightly inductive load‡
3-phase 3-pole (gG characteristic)
Maximum Short Circuit Prospective Fault Current Maximum Fuse Size
Switching Rate electrical
[A]
35
55
60
80
[ops/h]
120
120
120
120
Mechanical Data Performance Data Protection class acc. to IEC 529
Handles Switch Bodies
Mechanical Endurance Switching rate mechanical
12/16 A
20/25 A
32/40 A
IP66 IP20
IP66 IP20
IP66 IP20
[mil.ops]
1
1
1
[ops/h]
1200
1200
1200
AWG [mm2] AWG [mm2]
(2)18…12 (2)1…2.5 (2)18…12 (2)1…2.5
(2)16…10 (2)1.5…6 (2)16…10 (2)1.5…4
(2)12…8 (2)4…10 (2)14…10 (2)2.5…6
Maximum Wire Gauges rigid wire fine strands
Environmental Data Performance Data
12/16/20/25 A
32/40 A
Operation
-25…+60 °C (-13…+140 °F)
-25…+60 °C (-13…+140 °F)
Storage
-40…+80 °C (-40…+176 °F)
-40…+80 °C (-40…+176 °F)
Ambient temperature
Does not apply to switches in enclosure. ‡ Suitable for switching off-load (AC-20) above 660V, but only up to 660V for switches with screws at the rear. § See standards compliance listed on http://ab.rockwellautomation.com/Circuit-and-Load-Protection/Disconnect-Switches/Non-Visible-Blade/194R-Fused-NonFused-Disconnect-Switches#specifications
Rockwell Automation Publication 194-TD002B-EN-P
19
Page 20
194L Control and Load Switches
Approximate Dimensions
Approximate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
Cat. No. 194L-C… for Central Fixing (194L-HC…) Cat. No. 194L-HCA…
Cat. No. 194L-HCB…
Cat. No. 194L-HCD…
Dia. 30 (1-3/16)
L No. of Contacts Cat. No. 194L-C32/40...
1…2 86 (3-25/64)
3…4 103.5 (4-5/64)
5…6 121 (4-49/64)
7…8 138.5 (5-29/64)
9…10 156 (6-9/64)
Cat. No. 194L… for Front (Door) Installation
Cat. No. 194L-E 12/16…
Cat. No. 194L-E 20/25…
Mounting Dimensions
Cat. No. 194L-E 12/16… Cat. No. 194L-E 20/25… L No. of Contacts Cat. No.
1…2
3…4
5…6
7…8
9…10
194L-E12/16...
44 (1-47/64)
54 (2-1/8)
64 (2-33/64)
74 (2-29/32)
84 (3-5/16)
194L-E20/25...
44.5 (1-3/4)
57 (2-1/4)
69.5 (2-3/4)
82 (3-15/64)
94.5 (3-23/32)
194L-E32/40...
43 (1-11/16)
58.5 (2-5/16)
76 (2-63/64)
93.5 (3-11/16)
111 (4-3/8)
Control Knob Cat. No.
P
194L-HE4A...
48 (1-57/64) x 48 (1-57/64)
194L-HE4I... 194L-HE4S... 194L-HE6A...
48 (1-57/64) x 62 (2-7/16) 28 (1-7/64)
194L-HE6I... 194L-HE6S...
20
64 (2-33/64) x 64 (2-33/64) 64 (2-33/64) x 78 (3-5/64)
194L-HE6N... 194L-HE6G...
Q
34 (1-11/32)
Rockwell Automation Publication 194-TD002B-EN-P
67 (2-41/64) x 67 (2-41/64)
Page 21
Approximate Dimensions
194L Control and Load Switches
Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
Cat. No. 194L-A… for Base/DIN Rail Installation Cat. No. 194L-A 20/25… Dia. 3.3 (1/8)
Y Dimension Min. 2.5 (7/64)
Cat. No. 194L-A 12/16…
Max. 9.5 (3/8)
No. of Contacts Cat. No.
1…2
3…4
5…6
7…8
194L-A12/16...
58 (2-9/32)
68 (2-11/16)
78 (3-5/64)
88 (3-15/32)
194L-A20/25...
58 (2-9/32)
71.5 (2-13/16)
84 (3-5/16)
96.5 (3-51/64)
194L-A32/40...
67.5 (2-21/32)
85 (3-11/32)
102.5 (4-1/32)
120 (4-47/64)
Control Knob Cat. No.
P
B
194L-HE4A… 36 (1-27/64)
194L-HE4I… 194L-HE4S… 194L-HE6A…
64 (2-33/64) x 64 (2-33/64)
194L-HE6S… 194L-HE6G…
48 (1-57/64) x 48 (1-57/64) 48 (1-57/64) x 62 (2-7/16)
28 (1-7/64)
194L-HE6I… 194L-HE6N…
Q
48 (1-57/64) 34 (1-11/32)
64 (2-33/64) x 78 (3-5/64) 67 (2-41/64) x 67 (2-41/64)
With DIN 46 277 (35) Rail + 2.5 mm (7/64)
Rockwell Automation Publication 194-TD002B-EN-P
21
Page 22
194L Control and Load Switches
Approximate Dimensions
Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
Cat. No. 194L-A… With Shaft Extension Cat. No. 194L-G2853 Extensions
Dia. 3.3 (1.8)
No. of Contacts
Shaft Cat. No.
with No. of Extensions
Cat. No. 194L-A12/16... 10mm (0.39)
Cat. No. 194L-A20/25... 12.5mm (0.49)
Cat. No. 194L-A32/40
L No. of Contacts 1…2
3…4
5…6
7…8
1…2
3…4
5…6
7…8
1…2
3…4
5…6
7…8
With 1 extension
82 (3-15/64)
92 (3-5/8)
102 (4-1/64)
112 (4-13/32)
83 (3-17/64)
95.5 (3-49/64)
108 (4-1/4)
120.5 (4-3/4)
91.5 (3-15/64)
108 (4-1/4)
126.5 (5-63/64)
144 (6-43/64)
With 2 extensions
106 (4-11/64)
116 (4-37/64)
126 (4-31/32)
136 (5-23/64)
107 (4-7/32)
119.5 (4-45/64)
132 (5-13/64)
144.5 (5-11/16)
115.5 (5-35/64)
133 (5-15/64)
150.5 (6-5/16)
168 (7-5/8)
With 3 extensions
130 (5-1/8)
140 (5-33/64)
150 (5-29/32)
160 (6-19/64)
131 (5-5/32)
143.5 (5-21/32)
156 (6-9/64)
168.5 (6-5/8)
135.5 (5-11/32)
157 (6-3/16)
174.5 (7-7/8)
182 (8-9/16)
With 4 extensions
154 (6-1/16)
164 (6-15/32)
174 (6-55/64)
184 (7-15/64)
155 (6-7/64)
167.5 (6-19/32)
180 (7-3/32)
192.5 (7-37/64)
163.5 (6-7/16)
181 (7-1/8)
198.5 (8-53/64)
216 (9-33/64)
With 5 extensions
178 (7-1/64)
188 (7-13/32)
198 (7-51/64)
208 (8-3/16)
179 (7-3/64)
191.5 (7-35/64)
204 (8-1/32)
216.5 (8-33/64)
187.5 (7-3/8)
205 (8-5/64)
222.5 (9-49/64)
240 (9-29/64)
With 6 extensions
202 (7-61/64)
212 (8-23/64)
222 (8-3/4)
232 (9-1/8)
203 (7-63/64)
215.5 (8-31/64)
228 (8-63/64)
240.5 (9-15/32)
211.5 (8-21/64)
229 (12)
No. of Extensions
246.5 264 (10-23/32) (10-13/32)
Control Knob Cat. No. 194L-HE4A… 194L-HE4I… 194L-HE6A… 194L-HE6I… 194L-HE6N… 194L-HE6G…
Q
B
48 (1-57/64) x 48 (1-57/64)
36 (1-27/64)
64 (2-33/64) x 64 (2-33/64) 48 (1-57/64) 67 (2-41/64) x 67 (2-41/64)
When more than four modules are used, attach the first one to the switch body using the screws supplied with the extension (Cat. No. 194L-G2853). ‡ Mounting on DIN 46 277 (35) Rails.
22
Rockwell Automation Publication 194-TD002B-EN-P
Page 23
Approximate Dimensions
194L Control and Load Switches
Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
Cat. No. 194L-A… With Metal Shafts
Cat. No.
A
194L-G3393…
110 (4-21/64)…235(9-1/4)
194L-G3394…
230 (9-1/16)…350 (13-25/32)
No. of Contacts Cat. No.
1…2
3…4
5…6
7…8
194L-A12/16...
54 (2-1/8)
64 (2-33/64)
74 (2-29/32)
84 (3-5/16)
194L-A20/25...
55 (2-11/64)
67.5 (2-21/32)
80 (3-5/32)
92.5 (3-41/64)
194L-A32/40...
63.5 (2-31/64)
81 (3-3/16)
88.5 (3-7/8)
116 (4-9/16)
Enclosure Mounting Depth§ No. of Extension Modules 0
1
2
3
4
5
6
Required End Shaft
Cat. No. 194L-A12/16…
Cat. No. 194L-A20/25…
44 (1-47/64) ♣
71.5…77.5 (2-13/16…3-1/16)
75…80.5 (2-61/64…3-11/64)
52 (2-3/64)
77…87 (3-1/32…3-27/64)
80…90 (3-5/32…3-35/64)
57 (2-1/4)
82…92 (3-15/64…3-5/8)
85…95 (3-11/32…3-3/4)
44 (1-47/64) ♣
95.5…101.5 (3-49/64…4)
99…105 (3-29/32…4-9/64)
52 (2-3/64)
97.5…111 (3-27/32…4-3/8)
101…114.5 (3-63/64…4-33/64)
57 (2-1/4)
102.5…116 (4-3/64…4-37/64)
106…119.5 (4-11/64…4-45/64)
44 (1-47/64) ♣
119.5…125.5 (4-45/64…4-61/64)
123…129 (4-27/32…5-5/64)
52 (2-3/64)
121.5…135 (4-51/64…5-5/16)
125…138.5 (4-59/64…5-29/64) 130…143.5 (5-1/8…5-21/32)
57 (2-1/4)
126.5…140 (4-63/64…5-33/64)
44 (1-47/64) ♣
143.5…149.5 (5-21/32…5-57/64)
147…153 (5-51/64…6-1/32)
52 (2-3/64)
145.5…159 (5-47/64…6-17/64)
149…162.5 (5-7/8…6-13/32) 154…167.5 (6-1/16…6-19/32)
57 (2-1/4)
150.5…164 (5-15/16…6-15/32)
44 (1-47/64) ♣
167.5…173.5 (6-19/32…6-27/32)
171…177 (6-47/64…6-31/32)
52 (2-3/64)
169.5…183 (6-43/64…7-13/64)
173…186.5 (6-13/16…7-11/32) 178…191.5 (7-1/64…7-35/64)
57 (2-1/4)
174.5…188 (6-7/8…7-13/32)
44 (1-47/64) ♣
191.5…197.5 (7-35/64…7-25/32)
195…201 (7-43/64…7-59/64)
52 (2-3/64)
193.5…207 (7-5/8…8-5/32)
197…210.5 (7-49/64…8-19/64) 202…215.5 (7-61/64…8-31/64)
57 (2-1/4)
198.5…212 (7-53/64…8-23/64)
44 (1-47/64) ♣
215.5…221.5 (8-31/64…8-23/32)
219…225 (8-5/8…8-55/64)
52 (2-3/64)
217.5…231 (8-37/64…9-3/32)
221…234.5 (8-45/64…9-15/64)
57 (2-1/4)
222.5…236 (8-49/64…9-19/64)
226…239.5 (8-29/32…9-7/16)
When more than 4 modules are used, attach the first one to the switch body using the screws supplied with the extension (Cat. No. 194L-G2853). § For DIN Rail-mounted devices, remember to deduct the offset distance provided by the rail. For example, deduct 2.5 mm (7/64 in.) from the mounting depth for Bulletin 194L switch body mounted on DIN 46277 rail. ♣ One 44 mm (1-47/64 in) end shaft is supplied with all Bulletin 194L Switch Bodies.
Rockwell Automation Publication 194-TD002B-EN-P
23
Page 24
194L Control and Load Switches
Approximate Dimensions
Modular Shaft Extensions (Cat. No. 194L-G2853) Select No. of Extension Modules and Shaft for use with enclosures. Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Cat. No. 194L-A… With Cat. No. 194L-HE4P-…
L
Installation on DIN 46277 (35 mm) Rails + 2.5 mm (7/64 in.)
No. of Contacts
Cat. No. 194L-E… With Terminal Cover
Cat. No. 194L-A… With Terminal Cover
24
Cat. No.
1…2
3…4
5…6
7…8
194L-A12/16...
35 (1-3/8)
45 (1-49/64)
55 (2-11/64)
65 (2-9/16)
194L-A20/25...
33.5 (1-21/64)
48 (1-57/64)
60.5 (2-3/8)
73 (2-7/8)
194L-A32/40...
43 (1-11/16)
61 (2-13/32)
79 (3-7/64)
97 (3-53/64)
Cat. No.
A
B
C
D
194L-E12/16…
40 (1-37/64)
42.5 (1-43/64)
12 (15/32)
2.5 (7/64)
194L-E20/25…
49 (1-15/16)
37.5 (1-31/64)
12 (15/32)
2.5 (7/64)
194L-E32/40…
59 (2-21/64)
50 (1-31/32)
15 (19/32)
2.5 (7/64)
Cat. No.
A
B
C
D
194L-A12/16…
40 (1-37/64)
42.5 (1-43/64)
12 (15/32)
2.5 (7/64)
194L-A20/25…
49 (1-15/16)
37.5 (1-31/64)
12 (15/32)
2.5 (7/64)
194L-A32/40…
63.5 (2-1/2)
49 (1-53/64)
12 (15/32)
2 (5/64)
Rockwell Automation Publication 194-TD002B-EN-P
Page 25
Approximate Dimensions
194L Control and Load Switches
Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
Enclosure Cat. No. 194L-G3572…Cat. No. 194L-G3579
Cat. No. 194L-G3572/G3576 G3574/G3578
Cat. No. 194L-G3573/G3577 G3575/G3579
Rockwell Automation Publication 194-TD002B-EN-P
25
Page 26
Important User Information Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice. If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited.
Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete this form, publication RA-DU002, available at http://www.rockwellautomation.com/literature/.
Allen-Bradley, Rockwell Software, Rockwell Automation, and LISTEN. THINK. SOLVE are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.
Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400
Publication 194-TD002B-EN-P, May 2017 Supersedes Publication 194-TD002A, August 2014
Copyright © 2017 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.