The text of a manual ยท part 1 of 33
Kinetix 6000 Multi-axis Servo Drives User Manual, pages 1 to 8
Pages 1 to 8 of 290: Important User Information; Table of Contents
The original document is the PDF (21 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 2094-BM01 and Allen-Bradley 2094-PRF
Page 1
User Manual Original Instructions
Kinetix 6000 Multi-axis Servo Drives Catalog Numbers 2094-ACxx-Mxx-S, 2094-BCxx-Mxx-S, 2094-AMxx-S, 2094-BMxx-S 2094-ACxx-Mxx, 2094-BCxx-Mxx, 2094-AMxx, 2094-BMxx, 2094-BSP2, 2094-PRF, 2094-SEPM-B24-S
Page 2
Important User Information Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice. If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited. Throughout this manual, when necessary, we use notes to make you aware of safety considerations.
WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss. ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequence. IMPORTANT
Identifies information that is critical for successful application and understanding of the product.
Labels may also be on or inside the equipment to provide specific precautions. SHOCK HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that dangerous voltage may be present. BURN HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that surfaces may reach dangerous temperatures. ARC FLASH HAZARD: Labels may be on or inside the equipment, for example, a motor control center, to alert people to potential Arc Flash. Arc Flash will cause severe injury or death. Wear proper Personal Protective Equipment (PPE). Follow ALL Regulatory requirements for safe work practices and for Personal Protective Equipment (PPE).
Page 3
Table of Contents Summary of Changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Preface Conventions Used in This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Additional Resources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Chapter 1 Start
IAM/AM Module Series Changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 About the Kinetix 6000 Drive Systems . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Typical Hardware Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Typical Communication Configurations . . . . . . . . . . . . . . . . . . . . . . . . 19 Catalog Number Explanation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Kinetix Drive Component Compatibility . . . . . . . . . . . . . . . . . . . . . . . 21 Kinetix 6000M Integrated Drive-Motor System Compatibility . . . 21 Agency Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 CE Requirements (system without LIM module). . . . . . . . . . . . . 22 CE Requirements (system with LIM module). . . . . . . . . . . . . . . . 23
Chapter 2 Plan the Kinetix 6000 Drive System Installation
System Design Guidelines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 System Mounting Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Transformer Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 AC Line Filter Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Circuit Breaker/Fuse Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Enclosure Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Minimum Clearance Requirements . . . . . . . . . . . . . . . . . . . . . . . . . 33 Electrical Noise Reduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Bonding Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Bonding Multiple Subpanels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Establishing Noise Zones. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Cable Categories for Kinetix 6000 Systems . . . . . . . . . . . . . . . . . . 45 Noise Reduction Guidelines for Drive Accessories. . . . . . . . . . . . 47
Chapter 3 Mount the Kinetix 6000 Drive System
Before You Begin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Using the 2094 Mounting Brackets . . . . . . . . . . . . . . . . . . . . . . . . . 51 Installing the 2094 Power Rail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Determine Mounting Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Mount Modules on the Power Rail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
3
Page 4
Table of Contents
Chapter 4 Connector Data and Feature Descriptions
2094 IAM/AM Module Connector Data . . . . . . . . . . . . . . . . . . . . . . . 58 Safe Torque-off Connector Pinout. . . . . . . . . . . . . . . . . . . . . . . . . . 60 I/O Connector Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 Motor Feedback Connector Pinout . . . . . . . . . . . . . . . . . . . . . . . . . 62 Auxiliary Feedback Connector Pinout. . . . . . . . . . . . . . . . . . . . . . . 64 IAM Input Connector Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 IAM and AM Motor Power and Brake Connector Pinout . . . . 66 Control Signal Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Digital Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Sercos Communication Specifications. . . . . . . . . . . . . . . . . . . . . . . 68 Analog Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 Contactor Enable Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Power and Relay Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 Motor/Resistive Brake Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 Input Power Cycle Capability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Peak Enhancement Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 Control Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Feedback Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 Absolute Position Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 Motor Feedback Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 Feedback Power Supply Specifications. . . . . . . . . . . . . . . . . . . . . . . 80 Auxiliary Position Feedback Encoders . . . . . . . . . . . . . . . . . . . . . . . 81
Chapter 5 Connect the Kinetix 6000 Drive System
4
Basic Wiring Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 Building Your Own Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 Routing the Power and Signal Cables. . . . . . . . . . . . . . . . . . . . . . . . 84 Determine the Input Power Configuration . . . . . . . . . . . . . . . . . . . . . . 85 Grounded Power Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 Ungrounded Power Configurations . . . . . . . . . . . . . . . . . . . . . . . . . 87 DC Common Bus Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 Common Bus Fusing Requirements. . . . . . . . . . . . . . . . . . . . . . . . . 89 Set the Ground Jumper in Select Power Configurations . . . . . . . . . . 89 Set the Ground Jumper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 Grounding the Kinetix 6000 Drive System . . . . . . . . . . . . . . . . . . . . . . 95 Ground the Power Rail to the System Subpanel . . . . . . . . . . . . . . 95 Ground Multiple Subpanels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 Power Wiring Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 Power Wiring Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 Wiring the IAM/AM Module Connectors . . . . . . . . . . . . . . . . . . . . . 100 Wire the Control Power (CPD) Connector . . . . . . . . . . . . . . . . 100 Wire the Input Power (IPD) Connector. . . . . . . . . . . . . . . . . . . . 101 Wire the Contactor Enable (CED) Connector. . . . . . . . . . . . . . 103 Wiring the Safe Torque-off (STO) Connector . . . . . . . . . . . . . . 104 Wire the Motor Power (MP) Connector . . . . . . . . . . . . . . . . . . . 105
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
Page 5
Table of Contents
Wire the Motor/Resistive Brake (BC) Connector . . . . . . . . . . . 113 Apply the Motor Cable Shield Clamp. . . . . . . . . . . . . . . . . . . . . . . . . . 116 Feedback and I/O Cable Connections . . . . . . . . . . . . . . . . . . . . . . . . . 117 Flying-lead Feedback Cable Pinouts . . . . . . . . . . . . . . . . . . . . . . . . 119 Wiring the Feedback and I/O Connectors . . . . . . . . . . . . . . . . . . . . . 122 Connect Premolded Motor Feedback Cables . . . . . . . . . . . . . . . 122 Connect Panel-mounted Breakout Board Kits . . . . . . . . . . . . . . 123 Wire Low-profile Connector Kits. . . . . . . . . . . . . . . . . . . . . . . . . . 124 External Shunt Module Connections . . . . . . . . . . . . . . . . . . . . . . . . . . 127 IPIM Module Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 RBM Module Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 Sercos Fiber-optic Cable Connections . . . . . . . . . . . . . . . . . . . . . . . . . 130 Kinetix 6000M Integrated Drive-Motor Sercos Connections . . . . 133 Ethernet Cable Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
Chapter 6 Configure and Start the Kinetix 6000 Drive System
Configure the Kinetix 6000M Integrated Drive-Motor System. . . 135 Configure the Drive Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 Configure the Logix5000 Sercos interface Module . . . . . . . . . . . . . . 142 Configure the Logix5000 Controller . . . . . . . . . . . . . . . . . . . . . . . 142 Configure the Logix5000 Module. . . . . . . . . . . . . . . . . . . . . . . . . . 144 Configure the Kinetix 6000 Drive Modules. . . . . . . . . . . . . . . . . 146 Configure the Motion Group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 Configure Axis Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151 Download the Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154 Apply Power to the Kinetix 6000 Drive . . . . . . . . . . . . . . . . . . . . . . . . 155 Test and Tune the Axes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157 Test the Axes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157 Tune the Axes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159 Configure Drive Parameters and System Variables . . . . . . . . . . . . . . 162 Tools for Changing Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162 Monitor System Variables with Analog Test Points. . . . . . . . . . 163
Chapter 7 Troubleshooting the Kinetix 6000 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165 Interpret Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166 Drive System Kinetix 6000M IDM System Error Codes . . . . . . . . . . . . . . . . . . 166 Kinetix 6000 Drive System Error Codes . . . . . . . . . . . . . . . . . . . . 167 IAM/AM Module Status Indicators. . . . . . . . . . . . . . . . . . . . . . . . 172 Shunt Module Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . 173 General System Anomalies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175 Logix5000/Drive Fault Behavior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
5
Page 6
Table of Contents
Chapter 8 Remove and Replace the Kinetix 6000 Drive Modules
Before You Begin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181 Remove Kinetix 6000 Drive Modules . . . . . . . . . . . . . . . . . . . . . . . . . . 182 Replace Kinetix 6000 Drive Modules . . . . . . . . . . . . . . . . . . . . . . . . . . 183 Remove the Power Rail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184 Replace the Power Rail. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185
Appendix A Interconnect Diagrams
Interconnect Diagram Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188 Power Wiring Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189 DC Common Bus Wiring Examples . . . . . . . . . . . . . . . . . . . . . . . 193 Shunt Module Wiring Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . 197 Axis Module/Rotary Motor Wiring Examples . . . . . . . . . . . . . . . . . . 198 Axis Module/Linear Motor/Actuator Wiring Examples . . . . . . . . . 207 Kinetix 6000M Integrated Drive-Motor Wiring Example. . . . . . . . 212 Controlling a Brake Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213 System Block Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
Appendix B Upgrade the Drive Firmware
Upgrade Kinetix 6000M System Firmware . . . . . . . . . . . . . . . . . . . . . 217 Upgrade Drive Firmware with ControlFLASH Software . . . . . . . . 218 Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 Configure Logix5000 Communication . . . . . . . . . . . . . . . . . . . . . 219 Upgrade Firmware. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221 Verify the Firmware Upgrade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225
Appendix C DC Common Bus Applications
Before You Begin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227 Calculate Total Bus Capacitance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228 Calculate Additional Bus Capacitance . . . . . . . . . . . . . . . . . . . . . . . . . 229 Bulletin 2094 Drive Capacitance Values. . . . . . . . . . . . . . . . . . . . . . . . 229 Common Bus Capacitance Example . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 Set the Additional Bus Capacitance Parameter. . . . . . . . . . . . . . . . . . 231 Remove Sercos Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 Set the Additional Bus Capacitance Parameter . . . . . . . . . . . . . . 232 Save the Add Bus Cap Parameter to Nonvolatile Memory. . . . 233 Verify the Parameter Changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234 Reconnect Sercos Communication. . . . . . . . . . . . . . . . . . . . . . . . . 235
Appendix D Configure the Load Observer Feature
6
Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237 How it Works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238 Remaining IDN Parameter Descriptions . . . . . . . . . . . . . . . . . . . 240 Out-of-Box Gain Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242 Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
Page 7
Table of Contents
Auto-tune Gain Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244 Tuning Mode Summary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248 Manual Tuning for Further Optimization . . . . . . . . . . . . . . . . . . 248 Setting Gains with Sercos IDN Write Messages . . . . . . . . . . . . . . . . . 250 Compensate for High Frequency Resonances . . . . . . . . . . . . . . . . . . . 251
Appendix E Changing the Default IDN Parameter Values
Before You Begin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253 Change IDN Parameter Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254 Read the Present IDN Parameter Value . . . . . . . . . . . . . . . . . . . . 254 Calculate the New IDN Value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256 Write the New IDN Parameter Value . . . . . . . . . . . . . . . . . . . . . . 257
Appendix F Enhanced Peak Performance
Before You Begin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259 Enhanced Peak Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261 Enhanced Peak Example Calculation . . . . . . . . . . . . . . . . . . . . . . . 264 Change the Drive Parameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266 Sercos IDN Write Instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266 DriveExplorer Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267
Appendix G RBM Module Interconnect Diagrams
Before You Begin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 269 RBM Module Wiring Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
7
Page 8
Table of Contents
Notes:
8
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017