Manual · Allen-Bradley
Kinetix 6000 Multi-axis Servo Drives User Manual
Manual290 pagesPDF 21 MB
User manual for Allen-Bradley Kinetix 6000 multi-axis servo drives: 2094 IAM and AM modules, power rail, shunt and 2094-PRF slot filler.
Covers · 2 models
The models it covers
Summary
What is in it
Rockwell Automation user manual for the Kinetix 6000 multi-axis servo drive system, Bulletin 2094: integrated axis modules (IAM), axis modules (AM) such as the 2094-BMxx, the 2094-BSP2 shunt module, the 2094-PRF slot-filler module and the power rail. It covers planning the installation, noise reduction, mounting on the power rail, connector pinouts and specifications, wiring, configuring and starting the drives with Logix5000 Sercos modules, troubleshooting by status indicators, module replacement, interconnect diagrams and firmware upgrades.
Its parts
- Start
- Plan the Kinetix 6000 Drive System Installation
- Mount the Kinetix 6000 Drive System
- Connector Data and Feature Descriptions
- Connect the Kinetix 6000 Drive System
- Configure and Start the Kinetix 6000 Drive System
- Troubleshooting the Kinetix 6000 Drive System
- Remove and Replace the Kinetix 6000 Drive Modules
From the manual
Key facts from this manual
Each line names its page in the PDF.
Rockwell Automation user manual (publication 2094-UM001J-EN-P, March 2017) for the Kinetix 6000 multi-axis servo drive system, Bulletin 2094: integrated axis modules, axis modules such as the 2094-BM01, the 2094-BSP2 shunt module, the 2094-PRF slot-filler module and the 2094-SEPM-B24-S IPIM module. It covers planning, mounting on the power rail, connector data, wiring, configuration and start-up, troubleshooting by error code, module replacement, firmware upgrades and DC common bus applications.
- System
- Kinetix 6000 (Bulletin 2094) multi-axis servo drive system; IAM, AM, shunt and slot-filler modules mount on a 2094 power rail p. 14
- 2094-PRF
- 2094-PRF: slot-filler module, 200/400V-class; one is required for each empty power rail slot p. 14, 20
- 2094-BM01
- 2094-BM01: axis module (AM), 400V-class, 9 A, without safe torque-off (the 2094-BM01-S has it) p. 20
- Axis module role
- 2094-BM01: shared DC-bus inverter that must be used with an IAM module p. 14
- Peak enhancement
- 2094-BM01-S (series B and C): peak configurable to 250% of continuous inverter current, 150% from the factory; modules without -S lack the peak-enhanced feature p. 13, 14, 20
- Bus capacitance
- 2094-BM01: 150 µF; 2094-PRF: N/A p. 229, 230
- Power rail capacity
- One IAM module and up to seven AM/IPIM modules, or six AM/IPIM modules and one shunt module p. 52
- Communication
- Sercos (IEC 61491) over fiber-optic cable to Logix5000 controllers through 1756-MxxSE, 1768-M04SE or 1784-PM16SE p. 14
- Compatible motors
- MP-Series, TL-Series, RDD-Series, 1326AB and F-Series rotary motors; LDC-Series and LDL-Series linear motors p. 14
- Error codes
- E plus two digits on the seven-segment indicator, for example E06 hard overtravel, E07 motor feedback loss, E09 bus undervoltage, E10 bus overvoltage, E18 overspeed, E19 follow error, E34 ground fault p. 167, 168
- DC bus limits
- 460V system: undervoltage below 275V, overvoltage over 820V; 230V system: below 137V, over 410V p. 168
- Mounting screw torque
- 2.26 N•m (20 lb•in), for drive modules and the 2094-PRF alike p. 183
- AC line filter
- The manual states 2090-XXLF-xxxx three-phase AC line filters are required to meet CE p. 14
What this manual walks you through
- Choosing system components and catalog numbers p. 14, 20
- Enabling peak current enhancement p. 13
- Sizing an enclosure from system heat dissipation p. 30
- Mounting modules on the power rail in the right order p. 52
- Controlling a motor brake p. 71, 72
- Reading seven-segment error codes and fixing faults p. 167, 168
- Resetting IPIM module faults p. 166
- Replacing drive, shunt, slot-filler and IPIM modules on the power rail p. 183
- Calculating bus capacitance for DC common bus systems p. 229, 230
Good to know
- Put a 2094-PRF in every empty power rail slot; an empty slot disables the 2094 system while control power stays on. p. 15
- Leave the power rail protective covers on until the module for each slot is ready to mount. p. 52
- The power rail must be vertical before drive modules are replaced so the pins seat properly. p. 183
- Kinetix 6500 EtherNet/IP control modules cannot share a 2094 power rail with Kinetix 6000 Sercos drives. p. 21
- Motor parking-brake switching must not exceed 10 cycles per minute. p. 72
Questions this manual answers
What is the 2094-PRF?
A Kinetix 6000 slot-filler module, 200/400V-class, that fills an empty slot on the Bulletin 2094 power rail; one is needed for each empty slot. p. 14, 20
What is the 2094-BM01?
A Kinetix 6000 axis module, 400V-class, 9 A, without the safe torque-off feature; the 2094-BM01-S is the version with it. p. 20
Does the 2094-BM01 support peak enhancement?
The manual gives a 250% peak rating for the 2094-BM01-S (series B and C); axis modules without -S do not include the peak-enhanced feature. p. 13, 14
What torque does the Kinetix 6000 module mounting screw need?
2.26 N•m (20 lb•in); the same replacement steps apply to the 2094-PRF slot-filler module. p. 183
Contents
Chapters and sections
Each line opens the PDF at its page.
- Important User Information2
- Summary of Changes9
- Preface11
- Ch1 - Start13
- Ch2 - Plan the Kinetix 6000 Drive System Installation25
- Ch3 - Mount the Kinetix 6000 Drive System51
- Ch4 - Connector Data and Feature Descriptions57
- Ch5 - Connect the Kinetix 6000 Drive System83
- Basic Wiring Requirements83
- Determine the Input Power Configuration85
- Set the Ground Jumper in Select Power Configurations89
- Grounding the Kinetix 6000 Drive System95
- Power Wiring Requirements97
- Power Wiring Guidelines99
- Wiring the IAM/AM Module Connectors100
- Apply the Motor Cable Shield Clamp116
- Feedback and I/O Cable Connections117
- Wiring the Feedback and I/O Connectors122
- External Shunt Module Connections127
- IPIM Module Connections128
57 more lines, from page 129 on
- RBM Module Connections129
- Ch6 - Configure and Start the Kinetix 6000 Drive System135
- Ch7 - Troubleshooting the Kinetix 6000 Drive System165
- Ch8 - Remove and Replace the Kinetix 6000 Drive Modules181
- AppA - Interconnect Diagrams187
- AppB - Upgrade the Drive Firmware217
- AppC - DC Common Bus Applications227
- AppD - Configure the Load Observer Feature237
- AppE - Changing the Default IDN Parameter Values253
- AppF - Enhanced Peak Performance259
- AppG - RBM Module Interconnect Diagrams269
- Index281
- Back Cover290
The whole text · 33 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 81-8
- Pages 9 to 129-12
- Ch1 - Start13-24
- Ch2 - Plan the Kinetix 6000 Drive System Installation, pages 25 to 3325-33
- Ch2 - Plan the Kinetix 6000 Drive System Installation, pages 34 to 4234-42
- Ch2 - Plan the Kinetix 6000 Drive System Installation, pages 43 to 5043-50
- Ch3 - Mount the Kinetix 6000 Drive System51-56
- Ch4 - Connector Data and Feature Descriptions, pages 57 to 6557-65
- Ch4 - Connector Data and Feature Descriptions, pages 66 to 7466-74
- Ch4 - Connector Data and Feature Descriptions, pages 75 to 8275-82
- Ch5 - Connect the Kinetix 6000 Drive System, pages 83 to 9183-91
- Ch5 - Connect the Kinetix 6000 Drive System, pages 92 to 10092-100
- Ch5 - Connect the Kinetix 6000 Drive System, pages 101 to 109101-109
- Ch5 - Connect the Kinetix 6000 Drive System, pages 110 to 118110-118
- Ch5 - Connect the Kinetix 6000 Drive System, pages 119 to 127119-127
- Ch5 - Connect the Kinetix 6000 Drive System, pages 128 to 134128-134
- Ch6 - Configure and Start the Kinetix 6000 Drive System, pages 135 to 144135-144
- Ch6 - Configure and Start the Kinetix 6000 Drive System, pages 145 to 154145-154
- Ch6 - Configure and Start the Kinetix 6000 Drive System, pages 155 to 164155-164
- Ch7 - Troubleshooting the Kinetix 6000 Drive System, pages 165 to 172165-172
- Ch7 - Troubleshooting the Kinetix 6000 Drive System, pages 173 to 180173-180
- Ch8 - Remove and Replace the Kinetix 6000 Drive Modules181-186
- AppA - Interconnect Diagrams, pages 187 to 196187-196
- AppA - Interconnect Diagrams, pages 197 to 206197-206
- AppA - Interconnect Diagrams, pages 207 to 216207-216
- AppB - Upgrade the Drive Firmware217-226
- AppC - DC Common Bus Applications227-236
- AppD - Configure the Load Observer Feature, pages 237 to 244237-244
- AppD - Configure the Load Observer Feature, pages 245 to 252245-252
- AppE - Changing the Default IDN Parameter Values253-258
- AppF - Enhanced Peak Performance259-268
- AppG - RBM Module Interconnect Diagrams269-280
- Pages 281 to 290281-290
The file