The text of a manual · part 3 of 33
Kinetix 6000 Multi-axis Servo Drives User Manual: Ch1 - Start
Pages 13 to 24 of 290, from Kinetix 6000 Multi-axis Servo Drives User Manual
The original document is the PDF (21 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 2094-BM01 and Allen-Bradley 2094-PRF
Page 13
Chapter
1
Start Use this chapter to become familiar with the design and installation requirements for Kinetix® 6000 drive systems.
IAM/AM Module Series Changes
Topic
Page
IAM/AM Module Series Changes
13
About the Kinetix 6000 Drive Systems
14
Typical Hardware Configurations
15
Typical Communication Configurations
19
Catalog Number Explanation
20
Kinetix Drive Component Compatibility
21
Kinetix 6000M Integrated Drive-Motor System Compatibility
21
Agency Compliance
22
Series B drives included the peak current enhancement and applied to only the 460V (series A) IAM and AM modules. The peak current ratings of the Kinetix 6000 (460V) drives are configured at the factory as 150% of continuous current. However, you can program 460V AM modules and the equivalent IAM (inverter) modules, for up to 250% of continuous inverter current. Table 1 - Kinetix 6000 Enhanced Peak Performance Series Change
IMPORTANT
Peak Current Rating
IAM Module Cat. No.
AM Module Cat. No.
Series A (inverter)
Series B and C (inverter)
2094-BC01-MP5-S
2094-BMP5-S
150%
250%
2094-BC01-M01-S
2094-BM01-S
150%
250%
2094-BC02-M02-S
2094-BM02-S
150%
250%
2094-BC04-M03-S
2094-BM03-S
150%
250%
2094-BC07-M05-S
2094-BM05-S
150%
200%
Before your drive can deliver enhanced peak performance, you must enable the peak enhancement feature by configuring your drive with DriveExplorer™ software or the Logix Designer application. Refer to Appendix F on page 259 to recalculate torque and acceleration or deceleration limit values, and paste them into the appropriate Axis Properties dialog box in the Logix Designer application. For more information on setting axis properties, refer to Configure Axis Properties on page 151. In series C drives, a mechanical relay for the brake circuit and another for the safe torque-off inputs are replaced by solid-state relays and apply to the 230V (series A) and 460V (series B) IAM and AM modules. All wiring is consistent with previous series releases. Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
13
Page 14
Chapter 1
Start
About the Kinetix 6000 Drive Systems
The Kinetix 6000 multi-axis servo drives are designed to provide a Kinetix Integrated Motion solution for your drive/motor/actuator applications. Table 2 - Kinetix 6000 Drive System Overview
System Component
Cat. No.
Description
2094-xCxx-Mxx-S
Integrated Axis Modules (IAM) with the safe torque-off feature with 200V or 400V-class AC input power. Contains an inverter and converter section. The peak enhancement feature is available on 400V-class (series B and C) IAM modules.
2094-xCxx-Mxx
Integrated Axis Modules (IAM), with 200V or 400V-class AC input power (does not include the safe torque-off or peak-enhanced feature). Contains an inverter and converter section.
2094-xMxx-S
Axis Modules (AM) with safe torque-off are shared DC-bus inverters and rated for 200 or 400V-class operation. The AM module must be used with an IAM module. The peak enhancement feature is available on 400V-class (series B and C) AM modules.
2094-xMxx
Axis Modules (AM) are shared DC-bus inverters rated for 200V or 400V-class input power (does not include the safe torque-off or peak-enhanced feature). The AM module must be used with an IAM module.
Shunt Module
2094-BSP2
The Bulletin 2094 shunt module mounts to the power rail and provides additional shunting in regenerative applications.
Kinetix 6000M IDM System
2094-SEPM-B24-S Bulletin MDF
The Kinetix 6000M integrated drive-motor (IDM) system consists of the IDM power interface module (IPIM) and up to 16 (Bulletin MDF) IDM units. The IPIM module mounts on the Bulletin 2094 power rail and provides power and communication to the IDM units. The IPIM module also monitors power output and provides overload protection.
Power Rail
2094-PRSx 2094-PRx
The Bulletin 2094 power rail consists of copper bus bars and a circuit board with connectors for each module. The power rail provides power and control signals from the converter section to adjacent inverters. The IAM and AM power modules, shunt module, slot-filler modules mount to the power rail.
Slot-filler Module
2094-PRF
The Bulletin 2094 slot-filler module is used when one or more slots on the power rail are empty after all the other power rail modules are installed. One slot-filler module is required for each empty slot.
Logix5000™ Controllers
1756-MxxSE modules 1768-M04SE module 1784-PM16SE PCI card
The Sercos interface module/PCI card serves as a link between the ControlLogix®/CompactLogix™/SoftLogix™ controllers and the Kinetix 6000 drive system. The communication link uses the IEC 61491 SErial Real-time COmmunication System (Sercos) protocol over a fiber-optic cable.
1756-ENxTx modules
The Kinetix 6000M IPIM module connects to the EtherNet/IP network for monitoring, diagnostics, and firmware upgrades.
Studio 5000® Environment
9324-RLD300xxE
The Studio 5000 Logix Designer® application provides support for programming, commissioning, and maintaining the Logix5000 family of controllers.
Rotary Servo Motors
MP-Series™, TL-Series™, RDD-Series™, 1326AB, F-Series
Compatible rotary motors include the MP-Series (Bulletin MPL, MPM, MPF, and MPS) 200V and 400V-class motors; RDD-Series; TL-Series; 1326AB (M2L/S2L) and 1326AB (resolver); and F-Series motors.
Linear Motors
LDC-Series™, LDL-Series™
Compatible motors include LDC-Series iron core (200V and 400V-class) and LDL-Series ironless (200V-class) linear motors.
Linear Actuators
MP-Series
Compatible actuators include MP-Series (200V and 400V-class) Bulletin MPAS single-axis and Bulletin MPMA multi-axis integrated linear stages, and MP-Series (200V and 400V-class) Bulletin MPAR and MPAI electric cylinders.
LDAT-Series
LDAT-Series integrated linear actuators are compatible with 200V and 400V-class drive systems.
2090-Series power and feedback cables
Bulletin 2090 power and feedback cables are available with bayonet, threaded, and SpeedTec connectors. Power/brake cables have flying leads on the drive end and straight connectors that connect to servo motors. Feedback cables have flying leads that wire to low-profile connector kits on the drive end and straight connectors on the motor end.
Kinetix 6000M integrated drive-motor cables
Bulletin 2090 integrated drive-motor (IDM) hybrid and network cables connect between the 2094 IPIM module and the Kinetix 6000M IDM units. Bulletin 889D and 879D cables connect between digital input connectors and sensors.
Integrated Axis Module
Axis Module
Cables
Communication
Bulletin 2090 Sercos fiber-optic cables are available as enclosure only, PVC, nylon, and glass with connectors at both ends. Ethernet cables are available in standard lengths for Kinetix 6000M IPIM modules. Shielded cable is recommended.
AC Line Filters
2090-XXLF-xxxx
Bulletin 2090-XXLF-xxxx three-phase AC line filters are required to meet CE in all 200V and 400V-class drive systems.
Line Interface Modules
2094-xLxx 2094-xLxxS 2094-XL75S-Cx
Line interface modules (LIM) include the circuit breakers, AC line filter (catalog numbers 2094-AL09 and 2094-BL02 only), power supplies, and safety contactor required for Kinetix 6000 operation. The LIM module does not mount to the power rail. You can purchase individual components separately in place of the LIM module.
External Shunt Modules
1394-SRxxxx
You can use Bulletin 1394 external passive shunt modules when the IAM/AM module internal shunt and power rail mounted 2094-BSP2 shunt module capability is exceeded.
Resistive Brake Module
2090-XBxx-xx
Resistive Brake Modules (RBM) include a safety contactor for use in a control circuit. Contactors and resistors reside in this module such that the motor leads can be disconnected from the drive with the permanent magnet motor brought to an immediate stop. This module does not mount to the power rail.
14
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
Page 15
Start
Chapter 1
Typical Kinetix 6000 system installations include three-phase AC configurations, with and without the line interface module (LIM), and DC common-bus configurations.
Typical Hardware Configurations
SHOCK HAZARD: To avoid personal injury due to electrical shock, place a 2094-PRF slot-filler module in all empty slots on the power rail. Any power rail connector without a module installed disables the Bulletin 2094 system; however, control power is still present. Figure 1 - Typical Kinetix 6000 System Installation (with LIM) 2090-XXLF-xxxx AC Line Filter (required for CE)
Kinetix 6000 Multi-axis Servo Drive System
Three-Phase Input Power
2094-BSP2 Shunt Module (optional component)
115/230V Control Power
2094-PRF Slot-filler Module (required to fill any unused slots)
2094-xCxx-Mxx-S IAM Module
2094-PRSx Power Rail 2094-xLxxS Line Interface Module (optional component)
2094-xMxx-S Axis Modules (5) I/O Connections
To Input Sensors and Control String Bulletin 2090 Motor Feedback Cables
2090-K6CK-Dxxx Low Profile Connector Kits for I/O, Motor Feedback, and Aux Feedback Bulletin 2090 Motor Power Cables
MP-Series and TL-Series Rotary Motors (MPL-Bxxxx motors shown)
RDD-Series Direct Drive Motors (1) (RDB-Bxxxx motor shown)
MP-Series Integrated Linear Stages (MPAS-B9xxx ballscrew shown)
LDC-Series Linear Motors (LDC-Cxxxxxxx linear motor shown)
MP-Series Heavy Duty Electric Cylinders (MPAI-Bxxxx electric cylinders shown)
m USA www.ab.co IN MADE
A
075500 X XXXX LDC-M NO. XXXX CAT. L NO. SERIA
SERIES
LDL-Series Linear Motors (LDL-xxxxxxxx linear motor shown) MP-Series Electric Cylinders (MPAR-Bxxxx electric cylinder shown) LDAT-Series Linear Thrusters (LDL-Sxxxxxx-xBx linear thrusters only) (1) RDD-Series direct-drive motors require the 2090-K6CK-KENDAT low-profile feedback module.
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
15
Page 16
Chapter 1
Start
Figure 2 - Typical Kinetix 6000 System Installation (without LIM) Three-phase Input Power Line Disconnect Device 2090-XXLF-xxxx AC Line Filter (required for CE)
Input Fusing Single-phase Control Power Magnetic Contactor
2090-XXLF-xxxx AC Line Filter (required for CE)
Kinetix 6000 Multi-axis Servo Drive System
2094-BSP2 Shunt Module (optional component) 2094-PRF Slot-filler Module (required to fill any unused slots)
2094-xCxx-Mxx-S IAM Module
I/O Connections
2094-PRSx Power Rail
To Input Sensors and Control String
2094-xMxx-S Axis Modules (5)
Bulletin 2090 Motor Feedback Cables
2090-K6CK-Dxxx Low Profile Connector Kits for I/O, Motor Feedback, and Aux Feedback
MP-Series and TL-Series Rotary Motors (MPL-xxxx motors shown)
Bulletin 2090 Motor Power Cables
MP-Series Integrated Linear Stages (MPAS-B9xxx ballscrew shown)
RDD-Series Direct Drive Motors (1) (RDB-Bxxxx motor shown)
LDC-Series Linear Motors (LDC-Cxxxxxxx linear motor shown)
MP-Series Heavy Duty Electric Cylinders (MPAI-Bxxxx electric cylinders shown)
MP-Series Electric Cylinders (MPAR-Bxxxx electric cylinder shown)
m USA www.ab.co IN MADE
A
075500 X XXXX LDC-M NO. XXXX CAT. L NO. SERIA
SERIES
LDL-Series Linear Motors (LDL-xxxxxxxx linear motor shown)
LDAT-Series Linear Thrusters (LDL-Sxxxxxx-xBx linear thrusters only)
(1) RDD-Series direct-drive motors require the 2090-K6CK-KENDAT low-profile feedback module.
16
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
Page 17
Start
Chapter 1
This configuration illustrates the Kinetix 6000M integrated drive-motor (IDM) system with IDM power interface module (IPIM) installed on the Bulletin 2094 power rail. The IPIM module is included in the drive-to-drive fiber-optic cable installation along with the axis modules. Figure 3 - Typical Kinetix 6000M Integrated Drive-Motor System Installation 2094-SEPM-B24-S IPIM Module Three-phase Input Power 2094-BSP2 Shunt Module (optional component) Kinetix 6000 Multi-axis Servo Drive System
2094-PRF Slot Filler Module (required to fill any unused slots)
2094-PRSx Power Rail 2090-K6CK-Dxxxx Low Profile Connector Kits for I/O, Motor Feedback, and Aux Feedback
Bulletin 2090 Network Cables Bulletin 2090 Hybrid Cables
To Input Sensors and Control String MDF-SBxxxxx-Qx8xB-S Drive-Motor Unit Bulletin 2090 Motor Feedback Cables Compatible Rotary Motors, Linear Motors, and Linear Actuators (MPL-Bxxxx motor shown)
MDF-SBxxxxx-Qx8xB-S Drive-Motor Unit
MDF-SBxxxxx-Qx8xB-S Drive-Motor Unit
MDF-SBxxxxx-Qx8xB-S Drive-Motor Unit Bulletin 2090 Motor Power Cables
For more information on Kinetix 6000M integrated drive-motor system installation, refer to the Kinetix 6000M Integrated Drive-Motor System User Manual, publication 2094-UM003.
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
17
Page 18
Chapter 1
Start
Figure 4 - Typical (400V-class) DC Common Bus System Installation Three-phase Input Power
2090-XXLF-xxxx AC Line Filter (required for CE)
115/230V Control Power
Kinetix 6000 Multi-axis Servo Drive System
2094-BCxx-Mxx-S IAM Module Common Bus Leader
2094-BSP2 Shunt Module (optional component) 2094-PRF Slot-filler Module (required to fill any unused slots)
2094-PRSx Power Rail 2094-BLxxS Line Interface Module (optional component)
2094-BMxx-S Axis Modules (5)
DC Common Bus 2094-SEPM-B24-S IPIM Module 2094-PRF Slot-filler Module (required to fill any unused slots)
2094-BCxx-Mxx-S IAM Module Common Bus Follower
2094-PRSx Power Rail 2094-BMxx-S Axis Modules (5)
In the example above, the leader IAM module is connected to the follower IAM module via the DC common-bus. The follower system also includes the Kinetix 6000M integrated drive-motor (IDM) power interface module (IPIM) that supports up to 16 IDM units. When planning your panel layout, you must calculate the total bus capacitance of your DC common-bus system to be sure that the leader IAM module is sized sufficiently to precharge the entire system. Refer to Appendix C, beginning on page 227, for more information. IMPORTANT
18
If total bus capacitance of your system exceeds the leader IAM module precharge rating and input power is applied, the IAM module sevensegment status indicator displays error code E90 (precharge timeout fault). To correct this condition, you must replace the leader IAM module with a larger module or decrease the total bus capacitance by removing the IPIM module or AM modules.
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
Page 19
Start
Chapter 1
In this example, drive-to-drive Sercos cables and catalog numbers are shown when Kinetix 6000, Kinetix 6000M, and Kinetix 6200 drive modules exist on the same power rail.
Typical Communication Configurations
The Kinetix 6200 control modules use Sercos interface for configuring the Logix5000 module and the EtherNet/IP network for diagnostics and configuring safety functions. An Ethernet cable is connected to each control module during safety configuration. For more information on Ethernet cables, refer to the Industrial Ethernet Media Brochure, publication 1585-BR001. Figure 5 - Typical Kinetix 6000 and Kinetix 6200 Communication (Sercos) Logix5000 Controller Programming Network Logix5000 Sercos interface Module SERCOS interface
CP
OK
Logix5000 Controller (ControlLogix controller is shown)
The Logix Designer Application
Tx (rear) Rx (front)
2090-SCxxx-x Sercos Fiber-optic Cable 0.1 m (5.1 in.) Kinetix 6000 Drive-to-Drive Sercos Cables
2094-xCxx-Mxx-S IAM Module
2094-PRSx Power Rail 2094-xMxx-S Axis Modules (5) Kinetix 6000 and Kinetix 6000M (top view) Sercos Connectors
RX
TX Kinetix 6200 (top view) RX Sercos Connectors
TX
0.1 m (5.1 in.)
0.2 m (7.1 in.)
0.1 m (5.1 in.)
Kinetix 6000 Single-wide 2094-BCxx-Mxx-S IAM Module
0.2 m (7.1 in.)
0.1 m (5.1 in.)
Kinetix 6000 Double-wide 2094-BCxx-Mxx-S IAM Module 6200
SAFE SPEED
2094-SEPM-B24-S IPIM Module
6200
SAFE SPEED
2094-BMxx-S Double-wide AM Module 2094-BMxx-S Single-wide AM Module
2094-BMxx-M Single-wide AM Power Modules with 2094-SE02F-M00-Sx Control Modules 2094-BMxx-S Single-wide AM Module
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
19
Page 20
Chapter 1
Start
Catalog Number Explanation
Kinetix 6000 (Bulletin 2094) drive catalog numbers and descriptions are listed in the tables below. IMPORTANT
Throughout this publication, when the IAM or AM module catalog number is followed by -x, for example 2094-BMP5-x, the variable (x) indicates that the drive module may or may not include the safe torque-off feature.
Table 3 - Kinetix 6000 Drive Catalog Numbers Integrated Axis Modules (230V)
Cat. No. (with safe torque-off feature)
Cat. No. (without safe torque-off feature)
Kinetix 6000, IAM, 200V-class, 3 kW converter, 5 A inverter
2094-AC05-MP5-S
2094-AC05-MP5
Kinetix 6000, IAM, 200V-class, 3 kW converter, 9 A inverter
2094-AC05-M01-S
2094-AC05-M01
Kinetix 6000, IAM, 200V-class, 6 kW converter, 15 A inverter
2094-AC09-M02-S
2094-AC09-M02
Kinetix 6000, IAM, 200V-class, 11 kW converter, 24 A inverter
2094-AC16-M03-S
2094-AC16-M03
Kinetix 6000, IAM, 200V-class, 23 kW converter, 49 A inverter
2094-AC32-M05-S
2094-AC32-M05
Kinetix 6000, IAM, 400V-class, 6 kW converter, 4 A inverter
2094-BC01-MP5-S (1)
2094-BC01-MP5
Kinetix 6000, IAM, 400V-class, 6 kW converter, 9 A inverter
2094-BC01-M01-S (1)
2094-BC01-M01
Kinetix 6000, IAM, 400V-class, 15 kW converter, 15 A inverter
2094-BC02-M02-S (1)
2094-BC02-M02
Kinetix 6000, IAM, 400V-class, 28 kW converter, 30 A inverter
2094-BC04-M03-S (1)
2094-BC04-M03
Kinetix 6000, IAM, 400V-class, 45 kW converter, 49 A inverter
2094-BC07-M05-S (2)
2094-BC07-M05
Kinetix 6000, AM, 200V-class, 5 A
2094-AMP5-S
2094-AMP5
Kinetix 6000, AM, 200V-class, 9 A
2094-AM01-S
2094-AM01
Kinetix 6000, AM, 200V-class, 15 A
2094-AM02-S
2094-AM02
Kinetix 6000, AM, 200V-class, 24 A
2094-AM03-S
2094-AM03
Kinetix 6000, AM, 200V-class, 49 A
2094-AM05-S
2094-AM05
Kinetix 6000, AM, 400V-class, 4 A
2094-BMP5-S (1)
2094-BMP5
Kinetix 6000, AM, 400V-class, 9 A
2094-BM01-S (1)
2094-BM01
Kinetix 6000, AM, 400V-class, 15 A
2094-BM02-S (1)
2094-BM02
Kinetix 6000, AM, 400V-class, 30 A
2094-BM03-S (1)
2094-BM03
Kinetix 6000, AM, 400V-class, 49 A
2094-BM05-S (2)
2094-BM05
Integrated Axis Modules (460V)
Axis Modules (230V)
Axis Modules (460V)
(1) You can configure the peak inverter current rating of this 460V (series B and C) IAM or AM module for 250% of continuous inverter current. (2) You can configure the peak inverter current rating of this 460V (series B and C) IAM or AM module for 200% of continuous inverter current. Refer to Peak Enhancement Specifications on page 74, for more information on drive performance in the peak-enhanced mode.
Table 4 - Kinetix 6000 Drive Component Catalog Numbers
20
Drive Components
Cat. No.
Integrated power interface (IPIM) module, 400V-class, 15 kW, 24 A (rms)
2094-SEPM-B24-S
Kinetix 6000 shunt module, 200/400V-class, 200 W
2094-BSP2
Kinetix 6000 slot-filler module, 200/400V-class
2094-PRF
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
Page 21
Start
Kinetix Drive Component Compatibility
Chapter 1
The 2094-BCxx-Mxx-M and 2094-BMxx-M power modules contain the same power structure as the 2094-BCxx-Mxx-S and 2094-BMxx-S drive modules. Because of this, the 2094-BSP2 shunt module, 2094-PRF slot-filler module, and 2094-PRSx power rails are supported by both drive families. In addition, 2094-BMxx-M AM power modules with Sercos interface are supported on power rails with a 2094-BCxx-Mxx-S IAM drive module. Conversely, 2094-BMxx-S AM drive modules are supported on power rails with a 2094-BCxx-Mxx-M IAM power module with Sercos interface. IMPORTANT
Kinetix 6500 EtherNet/IP control modules (catalog numbers 2094-EN02D-M01-Sx) are not compatible with IAM/AM modules on the same Bulletin 2094 power rail with Kinetix 6000 or Kinetix 6200 Sercos drives.
Table 5 - IAM and AM Module/Network Compatibility
IAM Module
Control Module
2094-BCxx-Mxx-S (series B and C)
N/A
2094-BCxx-Mxx-M (IAM power module)
2094-SE02F-M00-Sx Sercos interface 2094-EN02D-M01-Sx EtherNet/IP network
2094-BMxx-M AM Power Modules
2094-BMxx-S Kinetix 6000 AM Module
2094-SE02F-M00-Sx Kinetix 6200 Control Module
2094-EN02D-M01-Sx Kinetix 6500 Control Module
Fully compatible
Fully compatible
Not compatible
Not compatible
Not compatible
Fully compatible
For additional information on the 2094-BCxx-Mxx-M (IAM) and 2094-BMxx-M (AM) modules, refer to the Kinetix 6200 and Kinetix 6500 Multi-axis Servo Drives User Manual, publication 2094-UM002.
Kinetix 6000M Integrated Drive-Motor System Compatibility
Bulletin 2094 power rails with Kinetix 6000 (series B and C) or Kinetix 6200 drives are compatible with Kinetix 6000M integrated drive-motor (IDM) systems. The IDM power interface module (IPIM) mounts to the power rail and connects to as many as 16 IDM units. Table 6 - IPIM Module Compatibility IAM Module
Control Module
2094-BCxx-Mxx-S (series B and C)
N/A
2094-BCxx-Mxx-M (IAM power module)
2094-SE02F-M00-Sx Sercos interface 2094-EN02D-M01-Sx EtherNet/IP network
2094-SEPM-B24-S IDM Power Interface Module (IPIM) Fully compatible Not compatible
For more information on Kinetix 6000M integrated drive-motor system installation, refer to the Kinetix 6000M Integrated Drive-Motor System User Manual, publication 2094-UM003.
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
21
Page 22
Chapter 1
Start
Agency Compliance
If this product is installed within the European Union and has the CE mark, the following regulations apply. ATTENTION: Meeting CE requires a grounded system, and the method of grounding the AC line filter and drive must match. Failure to do this renders the filter ineffective and can cause damage to the filter. For grounding examples, refer to Grounded Power Configurations on page 85. For more information on electrical noise reduction, refer to the System Design for Control of Electrical Noise Reference Manual, publication GMC-RM001.
CE Requirements (system without LIM module) To meet CE requirements when your Kinetix 6000 system does not include the LIM module, these requirements apply. • Install 2090-XXLF-xxxx AC line filters for three-phase input power and single-phase control power (for example, Schaffner P/N FN 355-10-05 or Roxburgh P/N RES5F08) as close to the IAM module as possible. • Use 2090 series motor power cables or use connector kits and terminate the cable shields to the chassis clamp provided. • Combined motor power cable lengths for all Kinetix 6000 axes and hybrid cable lengths for all IDM units on the same DC bus must not exceed 240 m (787 ft) with 400V-class systems or 160 m (525 ft) with 200V-class systems. Drive-to-motor power cables must not exceed 90 m (295.5 ft). • Use 2090 series motor feedback cables or use connector kits and properly terminate the feedback cable shield. Drive-to-motor feedback cables must not exceed 90 m (295.5 ft). • Install the Kinetix 6000 system inside an enclosure. Run input power wiring in conduit (grounded to the enclosure) outside of the enclosure. Separate signal and power cables. Refer to Appendix A on page 187 for interconnect diagrams, including input power wiring and drive/motor interconnect diagrams.
22
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
Page 23
Start
Chapter 1
CE Requirements (system with LIM module) To meet CE requirements when your Kinetix 6000 system includes the LIM module, follow all the requirements as stated in CE Requirements (system without LIM module) and these additional requirements as they apply to the AC line filter. • Install the LIM module (catalog numbers 2094-AL09 or 2094-BL02) as close to the IAM module as possible. • Install the LIM module (catalog numbers 2094-ALxxS, 2094-BLxxS, or 2094-XL75S-Cx) with line filter (catalog number 2090-XXLF-xxxx) as close to the IAM module as possible. When the LIM module (catalog numbers 2094-ALxxS, 2094-BLxxS, or 2094-XL75S-Cx) supports two IAM modules, each IAM module requires an AC line filter installed as close to the IAM module as possible.
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
23
Page 24
Chapter 1
Start
Notes:
24
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017