Page 181

Chapter

8

Remove and Replace the Kinetix 6000 Drive Modules

This chapter provides remove and replace procedures for your Kinetix® 6000 drive system components. Topic

Page

Before You Begin

181

Remove Kinetix 6000 Drive Modules

182

Replace Kinetix 6000 Drive Modules

183

Remove the Power Rail

184

Replace the Power Rail

185

ATTENTION: This drive contains electrostatic discharge (ESD) sensitive parts and assemblies. You are required to follow static-control precautions when you install, test, service, or repair this assembly. If you do not follow ESD control procedures, components can be damaged. If you are not familiar with static control procedures, refer to Guarding Against Electrostatic Damage, publication 8000-4.5.2, or any other applicable ESD awareness handbook.

Before You Begin

These tools are required before you begin removal and replacement procedures: • Screwdriver, 3.5 mm (0.14 in.) • Voltmeter

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

181

Page 182

Chapter 8

Remove and Replace the Kinetix 6000 Drive Modules

Remove Kinetix 6000 Drive Modules

Follow these steps to remove the IAM, AM, and IPIM modules from the Bulletin 2094 power rail. 1. Verify that all control and input power has been removed from the system. ATTENTION: To avoid shock hazard or personal injury, assure that all power has been removed before proceeding. This system can have multiple sources of power. More than one disconnect switch can be required to de-energize the system. 2. Wait five minutes for the DC bus to discharge completely before proceeding. ATTENTION: This product contains stored energy devices. To avoid hazard of electrical shock, verify that all voltage on capacitors has been discharged before attempting to service, repair, or remove this unit. Do not attempt the procedures in this document unless you are qualified to do so and are familiar with solid-state control equipment and the safety procedures in publication NFPA 70E. 3. Label and remove all connectors from the IAM/AM module you are removing. To identify each connector, refer to page 58. 4. Remove the motor cable from the cable shield clamp, as shown in these examples. Use screwdriver with 3.5 mm (0.14 in.) tip to depress spring and remove cable.

Vertical Cable Clamp Motor Orientation Example Cable

Horizontal Cable Clamp Orientation Examples Pry back with thumb.

Cable Clamp

Slide-open Cable Clamp

Pivot-open Cable Clamp

Screwdriver Tip in Slot Vent Holes on Top of IAM/AM Module

5. Loosen the mounting screw (bottom center of each module). 6. Grasp the top and bottom of the module with both hands and gently pull the module away from the connectors enough to clear the guide pins (module pivots on top bracket).

182

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

Page 183

Remove and Replace the Kinetix 6000 Drive Modules

Chapter 8

7. Lift the bracket out of the power rail slot and remove the module from the power rail.

Guide Pins

Power Rail (side view)

TIP

Replace Kinetix 6000 Drive Modules

Kinetix 6000 Drive Module (side view) (IAM module is shown)

This procedure also applies to Bulletin 2094-BSP2 shunt module, 2094-PRF slot-filler module, and 2094-SEPM-B24-S IPIM module.

Follow these steps to replace drives from the Bulletin 2094 power rail. 1. Determine your drive module replacement. If you are

Then

Replacing a drive module on an existing power rail

Go to step 3.

Replacing a drive module on a new power rail

Go to step 2.

2. Prepare to mount your replacement drive module by removing the protective covers from the power rail connectors. 3. Hang the mounting bracket from the slot on the power rail. IMPORTANT

Power rails must be in vertical orientation before replacing drive modules for pins to seat properly.

4. Align the guide pins on the power rail with the guide pin holes in the back of the drive module (refer to the figure above). TIP

The IAM module can have two or three power rail connectors and guide pins, the AM module can have one or two, all other modules have only one connector and one guide pin.

5. Use 2.26 N•m (20 lb•in) torque to tighten the mounting screw. 6. Reconnect the module connectors. 7. Reapply power to the system.

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

183

Page 184

Chapter 8

Remove and Replace the Kinetix 6000 Drive Modules

8. Verify that the system is operating properly. TIP

Remove the Power Rail

Because parameter settings reside in the Logix Designer application, you do not need to perform any tuning or set-up procedures.

This procedure assumes you have removed all modules from the power rail. Follow these steps to remove the power rail. 1. Disconnect the braided grounding strap from the grounding stud on the right side of the power rail. Braided Ground Strap 100 mm (3.9 in.)

Bonded Cabinet Ground

Power Rail 2094-PRx

Braided Ground Strap 100 mm (3.9 in.)

Power Rail 2094-PRSx

Bonded Cabinet Ground

2. Loosen the mounting bolts (removing the bolts is not necessary). 3. Lift the power rail up and off of the mounting bolts.

184

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

Page 185

Remove and Replace the Kinetix 6000 Drive Modules

Replace the Power Rail

Chapter 8

This procedure assumes you do not need to change the location of the power rail on the panel and you intend to reuse the mounting bolts of the power rail you just removed. IMPORTANT

If you need to change the location of the power rail, or if you are installing a power rail designed for additional or fewer modules than you removed, refer to Kinetix 6000 Power Rail Installation Instructions, publication 2094-IN003.

ATTENTION: To avoid damage to the power rail during installation, do not remove the protective covers until the module for each slot is ready for mounting. Follow these steps to replace the power rail. 1. Align the replacement power rail over the existing mounting bolts. IMPORTANT

To improve the bond between the power rail and subpanel, construct your subpanel out of zinc plated (paint-free) steel.

2. Tighten the mounting bolts. 3. Reattach the braided grounding strap to the power rail grounding stud (refer to page 184).

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

185

Page 186

Chapter 8

Remove and Replace the Kinetix 6000 Drive Modules

Notes:

186