Page 75

Connector Data and Feature Descriptions

Chapter 4

Figure 34 - Load Duty-cycle Profile Example I PK

I Cont

D = T PK x 100% T

I Base

T PK T

Table 48 - Peak Duty Cycle Definition of Terms Term

Definition (1)

Continuous Current Rating (ICont)

The maximum value of current that can be output continuously.

Peak Current Rating (IPKmax)

The maximum value of peak current that the drive can output. This rating is valid only for overload times less than TPKmax. The ratio of time at peak to the Application Period and is defined as:

Duty Cycle (D)

D = T PK x 100% T

Time at Peak (TPK)

The time at peak current (IPK) for a given loading profile. Must be less than or equal to TPKmax.

Peak Current (IPK)

The level of peak current for a given loading profile. IPK must be less than or equal to the Peak Current Rating (TPKMAX) of the drive.

Base Current (IBase)

The level of current between the pulses of peak current for a given loading profile. IBase must be less than or equal to the continuous current rating (ICont) of the drive.

Loading Profile

The loading profile is comprised of IPK, IBase, TPK, and D (or T) values and completely specify the operation of the drive in an overload situation. These values are collectively defined as the Loading Profile of the drive.

Application Period (T)

The sum of the times at IPK (TPK) and IBase.

(1) All current values are specified as RMS.

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

75

Page 76

Chapter 4

Connector Data and Feature Descriptions

Figure 35 - Peak Inverter Overload (TPK < 2.0 s) 50% 45%

Maximum Duty Cycle (D max)

40% 35%

Legend

(1)

30%

I PK = 150%

25% 20%

I PK = 200%

15%

I PK = 250%

10%

Applies to these Kinetix 6000 drives: 2094-BC01-MP5-S, 2094-BMP5-S, 2094-BC01-M01-S, 2094-BM01-S, 2094-BC02-M02-S, 2094-BM02-S, 2094-BC04-M03-S, 2094-BM03-S

5% 0% 0%

20%

40%

60%

80%

100%

% Base Current (IBase /I Cont) (1) Base current (IBase) and peak current (IPK) are a percentage of the continuous drive current rating (ICont).

Figure 36 - Peak Inverter Overload (TPK < 2.0 s) 50% 45%

Maximum Duty Cycle (D max)

40% 35%

Legend

(1)

30%

I PK = 150%

25% I PK = 200%

20%

Applies to these Kinetix 6000 drives: 2094-BC07-M05-S, 2094-BM05-S

15% 10% 5% 0% 0%

20%

40%

60%

80%

100%

% Base Current (IBase /I Cont) (1) Base current (IBase) and peak current (IPK) are a percentage of the continuous drive current rating (ICont).

76

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

Page 77

Connector Data and Feature Descriptions

Chapter 4

Control Power The IAM module requires AC input power for logic circuitry. IMPORTANT

The control power input requires an AC (EMC) line filter for CE certification. For filter examples, refer to Agency Compliance on page 22.

IMPORTANT

2094-BCxx-Mxx-x (460V) IAM modules require a step down transformer for single-phase control power input. Source the 2094-ACxx-Mxx-x (230V) IAM module control power from the three-phase input power (line-to-line) with neither leg bonded to ground or neutral potential. The National Electrical Code and local electrical codes take precedence over the values and methods provided. Implementation of these codes is the responsibility of the machine builder.

Table 49 - Control Power Input Power Specifications Attribute

Value

Input voltage

95…264V AC rms, single-phase

Input power frequency

47…63 Hz

Control power AC input current Nom @ 220/230V AC rms Nom @ 110/115V AC rms Max inrush (0-pk)

6A 6A 98 A (1)

(1) For eight axis systems with 230V AC control input voltage and 50 °C (122°F) ambient temperature the maximum inrush duration is less than 1/2 line cycle. Use this equation to calculate maximum inrush current for systems with different axis count and control input voltage. IPK = 0.043 x (VIN) + 6.72 x (# of axes) + 0.000333 x (VIN2) - 0.816 x (# of axes)2 + 0.0358 x (# of axes x VIN)

Table 50 - Control Power Current Requirements 110/115V AC Input Modules on Power Rail Input Current Input VA A VA

220/230V AC Input Input Current A

Input VA VA

IAM module only

0.56

67

0.36

85

IAM and 1 AM module

0.99

119

0.64

153

IAM and 2 AM module

1.43

172

0.92

220

IAM and 3 AM module

1.87

224

1.20

287

IAM and 4 AM module

2.31

277

1.48

354

IAM and 5 AM module

2.74

329

1.75

421

IAM and 6 AM module

3.18

382

2.03

488

IAM and 7 AM module

3.62

434

2.31

555

IDM power interface module (IPIM)

For specifications and an example for calculating the IPIM module current requirements, refer to the Kinetix 6000M Integrated Drive-Motor User Manual, publication 2094-UM003.

For Kinetix 6000M systems, calculate the sum of the control power current requirements for each IPIM module on the power rail and add that value with the appropriate value from Table 50 for the number of axes on the power rail. Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

77

Page 78

Chapter 4

Connector Data and Feature Descriptions

The IAM and AM modules can accept motor and auxiliary feedback signals from these types of encoders: • Stegmann Hiperface • TTL or Sine/Cosine with index pulse and Hall commutation • Resolver Transmitter TR = 0.25 (motor feedback only)

Feedback Specifications

Motor feedback from Heidenhain EnDat high-resolution encoders is also accepted, but only when using drive firmware revision 1.116 or later and the 2090-K6CK-KENDAT low-profile feedback module for EnDat to Hiperface conversion. TIP

Auto-configuration in the Logix Designer application of intelligent absolute, highresolution, incremental, and EnDat encoders is possible only with Allen-Bradley motors.

Absolute Position Feature The drive’s absolute position feature tracks the position of the motor, within the multi-turn retention limits, while the drive is powered off. The absolute position feature is available with only these multi-turn encoders. Table 51 - Absolute Position Designator Examples Encoder Type

Cat. No. Designator

Motor/Actuator Cat. No.

Retention Limits (turns)

-M

MPL-A/Bxxxxx-M, MPM-A/Bxxxxx-M, MPF-A/Bxxxxx-M, MPS-A/Bxxxxx-M, MPAR-A/B3xxxx-M, MPAI-A/BxxxxxM

4096 (±2048)

-V

MPL-A/Bxxxxx-V, MPAS-A/Bxxxx1-V05, A/MPAS-Bxxxx2-V20, MPAR-A/B1xxxx-V, MPAR-A/B2xxxx-V, MPAI-A/BxxxxxV

4096 (±2048)

-7

RDB-Bxxxxxx-7

4096 (±2048)

Stegmann Hiperface

Heidenhain EnDat

Figure 37 - Absolute Position Limits (measured in turns) 4096 Turns 2048 Turns 1024 Turns

-2048

78

-1024

-512

-256

-128

-64

0 +64 Position at Power Down

+128

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

+256

+512

+1024

+2048

Page 79

Connector Data and Feature Descriptions

Chapter 4

Motor Feedback Specifications AM, BM, and IM input encoder signals are filtered by using analog and digital filtering. The inputs also include illegal state change detection. Figure 38 - AM, BM, and IM Motor Encoder Input Circuits +5 V 1k Ω

+

10k Ω 56 pF

1k Ω -

+

1k Ω 56 pF

1k Ω 56 pF 1k Ω 1k Ω

100 pF 1k Ω

56 pF

10k Ω

1k Ω 56 pF 10k Ω

1k Ω

56 pF 100 pF

10k Ω

Drive

Drive AM and BM Channel Inputs

IM Channel Input

Table 52 - Motor Encoder Feedback Specifications Attribute

Value

Encoder types

Incremental, A quad B, sine/cosine, intelligent, resolver, and absolute

Maximum input frequency Commutation feedback

500 kHz (TTL input) per channel 250 kHz (sine/cosine input) Hall sensor

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

79

Page 80

Chapter 4

Connector Data and Feature Descriptions

Table 53 - AM, BM, and IM Input Specifications for TTL Encoders Parameter

Description

Min

Max

AM, BM, and IM On-state input voltage

Input voltage difference between the plus (+) input and the minus (-) input that is detected as an on-state.

+1.0V

+7.0V

AM, BM, and IM Off-state input voltage

Input voltage difference between the plus (+) input and the minus (-) input that is detected as an off-state.

-1.0V

-7.0V

Common mode input voltage

Potential difference between any encoder signal and logic ground.

-7.0V

+12.0V

DC current draw

Current draw into the + or - input.

-30 mA

30 mA

AM, BM input signal frequency

Frequency of the AM or BM signal inputs. The count frequency is 4 times this frequency, because the circuitry counts all four transitions.

–

500 kHz

IM pulse width

Pulse width of the index input signal. Because the index is active for a percentage of a revolution, the speed determines the pulse width.

125 nS

–

AM, BM phase error 250 KHz line frequency

Amount that the phase relationship between the AM and BM inputs can deviate from the nominal 90°.

-22.5°

+22.5°

AM, BM phase error 100 KHz line frequency

Amount that the phase relationship between the AM and BM inputs can deviate from the nominal 90°.

-45°

+45°

Table 54 - AM, BM, and IM Input Specifications for Sine/Cosine Encoders Parameter

Description

Min

Max

Sine/cosine input signal frequency

Frequency of the Sine or Cosine signal inputs.

–

250 kHz

Sine/cosine input voltage

Peak-to-peak input voltages of the Sine or Cosine inputs.

0.8V (p-p)

1.2V (p-p)

Table 55 - Specifications for Heidenhain EnDat Encoders Command Set

Order Designation

Description

EnDat 2.2

EnDat 01

1V p-p Sin/Cos, <2 MHz clock frequency

Feedback Power Supply Specifications The IAM and AM power circuit board generates +5V and +9V DC for motor and auxiliary feedback power. Short circuit protection and separate common mode filtering for each channel is included.

80

Supply

Reference

+5V DC +9V DC

Voltage

Current mA

Min

Nominal

Max

Min

Max

EPWR_5V

4.9

5.25

5.4

0

400

EPWR_9V

8.3

9.1

9.9

0

275

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

Page 81

Connector Data and Feature Descriptions

Chapter 4

Auxiliary Position Feedback Encoders Allen-Bradley Bulletin 842HR, 844D, 847H, and 847T encoders are the preferred encoders for auxiliary feedback connections. Table 56 - Allen-Bradley Auxiliary Feedback Encoders Cat. No.

Description

842HR-MJDZ115FWYD (multi-turn) 842HR-SJDZ115FWYD (single-turn)

Size 25, sine/cosine (serial), square flange, 3/8 in. solid shaft with flat, 5…12V DC, digital RS-485 interface, M23, 17-pin connector

844D-B5CC1FW 844D-B5CC1CS 844D-B5CC1DR 847H-DN1A-RH01024 847H-DN1A-RH02048 847H-DN1A-RH05000 847T-DN1A-RH01024 847T-DN1A-RH02048

HS35, hollow-shaft incremental encoders, rear (through-shaft), 5/8 inch, tether, 3/8 in. bolt on a 2.5…4.0 in. diameter, 10-pin connector, 5V DC in, 5V DC DLD out Size 25, incremental encoder, standard square flange , 3/8 inch diameter shaft with flat, 4.5…5.5V line driver, TTL (B-Leads-A, CW, Z gated with BN), MS connector, 10-pin Size 20, incremental encoder, standard square flange , 3/8 inch diameter shaft with flat, 4.5…5.5V line driver, TTL (B-Leads-A, CW, Z gated with BN), MS connector, 10-pin

Refer to the Kinetix Motion Accessories Technical Data, publication KNX-TD004, for more information on these Allen-Bradley encoders.

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

81

Page 82

Chapter 4

Connector Data and Feature Descriptions

Notes:

82

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017