Kinetix 6000 Multi-axis Servo Drives User Manual: AppB - Upgrade the Drive Firmware

Pages 217 to 226 of 290, from Kinetix 6000 Multi-axis Servo Drives User Manual

The original document is the PDF (21 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 2094-BM01 and Allen-Bradley 2094-PRF

Page 217

Appendix

B

Upgrade the Drive Firmware

This appendix provides procedures for upgrading Kinetix® 6000 drive firmware by using ControlFLASH™ software.

Upgrade Kinetix 6000M System Firmware

Topic

Page

Upgrade Kinetix 6000M System Firmware

217

Upgrade Drive Firmware with ControlFLASH Software

218

Upgrading firmware for the Kinetix 6000M integrated drive-motor (IDM) system is done by using ControlFLASH software. The procedure for upgrading the IDM units uses the Sercos interface, similar to the axis modules. However, upgrading firmware on the IPIM module is accomplished over the EtherNet/IP network. IMPORTANT

DriveExplorer™ software does not apply to Kinetix 6000M firmware upgrades.

For the firmware upgrade procedure specific to the IDM system, refer to the Kinetix 6000M Integrated Drive-Motor System User Manual, publication 2094-UM003.

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

217

Page 218

Appendix B

Upgrade the Drive Firmware

Upgrade Drive Firmware with ControlFLASH Software

Upgrading axis module firmware by using ControlFLASH software involves configuring your controller communication, selecting the drive to upgrade, and upgrading the firmware.

Before You Begin You need the following software and information before you begin. Description

Cat. No.

Firmware Revision or Software Version

RSLogix 5000® software or Studio 5000 Logix Designer®

RSLogix 5000 software

15.x or later

Logix Designer application

21.x or later

1756-MxxSE

15.32 or later

1756-L60M03SE

15.4 or later

CompactLogix™ Sercos module

1768-M04SE

15.35 or later

SoftLogix™ Sercos PCI card

1784-PM16SE

15.33 or later

ControlLogix® Sercos module

RSLinx® software

2.50 or later

ControlFLASH software kit (1)

4.00.09 or later

Catalog number of the targeted IAM/AM module you want to upgrade Network path to the targeted IAM/AM module. (1) Download the ControlFLASH kit from http://support.rockwellautomation.com/controlflash. Contact Rockwell Automation Technical Support at (440) 646-5800 for assistance. For more ControlFLASH information (not drive specific), refer to the ControlFLASH Firmware Upgrade Kit User Manual, publication 1756-UM105.

IMPORTANT

Control power must be present at CPD-1 and CPD-2 prior to upgrading your target drive. The seven-segment status indicator on the target IAM (inverter) module or AM module must be displaying a fixed 2, 3, or 4 before beginning this procedure.

ATTENTION: To avoid personal injury or damage to equipment during the firmware upgrade due to unpredictable motor activity, do not apply threephase AC or common-bus DC input power to the drive.

218

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

Page 219

Upgrade the Drive Firmware

Appendix B

Configure Logix5000 Communication This procedure assumes that your communication method to the Logix5000™ controller is using the Ethernet protocol. It is also assumed that your Logix5000 Ethernet module has already been configured. For more information, refer to the ControlLogix System User Manual, publication 1756-UM001. Follow these steps to configure Logix5000 communication. 1. Open your RSLinx Classic software. 2. From the Communications pull-down menu, choose Configure Drivers. The Configure Drivers dialog box opens.

3. From the Available Drive Types pull-down menu, choose Ethernet devices. 4. Click Add New. The Add New RSLinx Classic Driver dialog box opens. 5. Type the new driver name.

6. Click OK. The Configure driver dialog box opens.

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

219

Page 220

Appendix B

Upgrade the Drive Firmware

7. Type the IP address of your Logix5000 Ethernet module. The IP address shown is an example. Yours will be different. 8. Click OK. The new Ethernet driver appears under Configured Drivers.

9. Click Close. 10. Minimize the RSLinx application dialog box.

220

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

Page 221

Upgrade the Drive Firmware

Appendix B

Upgrade Firmware Follow these steps to select the drive module to upgrade. 1. Open your ControlFLASH software. You can access the ControlFLASH software by either of these methods: • From the Tools menu in the Logix Designer application, choose ControlFLASH. • Choose Start>Programs>FLASH Programming Tools> ControlFLASH. The Welcome to ControlFLASH dialog box opens.

2. Click Next. The Catalog Number dialog box opens.

3. Select your drive module. In this example, the 2094-BC01-MP5 IAM module is selected. 4. Click Next.

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

221

Page 222

Appendix B

Upgrade the Drive Firmware

The Select Device to Update dialog box opens.

5. Expand your Ethernet node, Logix5000 backplane, and EtherNet/IP network module. 6. Select the servo drive to upgrade. 7. Click OK. The Firmware Revision dialog box opens.

8. Select the firmware revision to upgrade. 9. Click Next.

222

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

Page 223

Upgrade the Drive Firmware

Appendix B

The Summary dialog box opens.

10. Confirm the drive catalog number and firmware revision. 11. Click Finish. This ControlFLASH warning dialog box opens.

12. Click Yes (only if you are ready). This ControlFLASH warning dialog box opens.

13. Acknowledge the warning and click OK.

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

223

Page 224

Appendix B

Upgrade the Drive Firmware

The Progress dialog box opens and upgrading begins.

The drive module seven-segment status indicator changes from the fixed 2, 3, or 4 to F, which indicates that upgrading is in progress. After the upgrade information is sent to the drive, the drive resets and performs diagnostic checking. 14. Wait for the Progress dialog box to time out.

15. The Update Status dialog box opens and indicates success or failure as described below. Upgrading Status

If

Success

1. Update complete appears in a GREEN Status dialog box. 2. Go to step 16.

Failure

1. Update failure appears in a RED Status dialog box. 2. Refer to ControlFLASH Firmware Upgrade Kit Quick Start, publication 1756-QS105, for troubleshooting information.

16. Click OK.

224

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

Page 225

Upgrade the Drive Firmware

Appendix B

Verify the Firmware Upgrade Follow these steps to verify your firmware upgrade was successful. TIP

Verifying the firmware upgrade is optional.

1. Open your RSLinx software. 2. From the Communications pull-down menu, choose RSWho.

3. Expand your Ethernet node, Logix5000 backplane, and EtherNet/IP network module. 4. Right-click the drive module and choose Device Properties. The Device Properties dialog box opens.

5. Verify the new firmware revision level. 6. Click Close.

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

225

Page 226

Appendix B

Upgrade the Drive Firmware

Notes:

226

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017