The text of a manual · part 25 of 33
Kinetix 6000 Multi-axis Servo Drives User Manual: AppA - Interconnect Diagrams, pages 207 to 216
Pages 207 to 216 of 290, from Kinetix 6000 Multi-axis Servo Drives User Manual
The original document is the PDF (21 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 2094-BM01 and Allen-Bradley 2094-PRF
Page 207
Interconnect Diagrams
Appendix A
These examples apply to Kinetix 6000 drives with Allen-Bradley linear motors and actuators.
Axis Module/Linear Motor/ Actuator Wiring Examples
Figure 104 - AM Module with MP-Series Integrated Linear Stages MPAS-A/Bxxxxx-VxxSxA Ballscrew Linear Stages with High Resolution Feedback
IAM (inverter) or AM Module Note 15
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Cable Shield Clamp
Shield
Note 10
Motor Power (MP) Connector
W V U
4 3 2 1
Motor Feedback (MF) Connector
MBRK MBRK +
DBRK DBRK +
C B
W
GND V Three-phase
Brown
A
U Motor Power
Black
5
Motor Feedback
G F
User Supplied 24V DC
3
PWR
Blue Black
White
4
COM
D
6
2
BR-
1
BR+
2090-K6CK-D15M Connector Kit BLACK WHITE/BLACK
1 2
3 4
SIN+ SINCOS+ COS-
RED WHITE/RED
3 4
5 6 9 10 11 13
DATA+ DATA+5VDC ECOM +9VDC TS
GREEN WHITE/GREEN
5 10 14 6 7 11
1 2
Green/Yellow
2090-CPxM7DF-16AAxx (standard) or 2090-CPxM7DF-16AFxx (continuous-flex) Power Cable Note 16
Motor/Resistive Brake (BC) Connector
Refer to table on page 188 for note information.
BR+
Thermostat 12
Refer to low-profile connector illustration (lower left) for proper grounding technique.
COM
Motor Brake
2090-CFBM7DF-CEAAxx (standard) or 2090-CFBM7DF-CEAFxx (continuous-flex) (flying-lead) Feedback Cable Notes 16, 19, 20
MPAS-A/Bxxxxx-ALMx2C Direct Drive Linear Stages with Incremental Feedback
W
A
U
V
GND
Three-phase Motor Power Motor Feedback
Grounding Technique for Feedback Cable Shield
2090-K6CK-D15M Low-profile Connector Kit
2090-K6CK-D15M Connector Kit 1 2
D C B
ORANGE WHITE/ORANGE
14
BR-
Resistive Brake Connections
2090-CPWM7DF- 16AAxx (standard) or 2090-CPWM7DF-16AFxx (continuous-flex) Power Cable Note 16
GRAY WHITE/GRAY
Thermostat
BLACK WHITE/BLACK
1 2
3 4
AM+ AMBM+ BM-
RED WHITE/RED
3 4
5 6 9 10 11 13
IM+ IM+5VDC ECOM – TS
GREEN WHITE/GREEN GRAY WHITE/GRAY
5 10 14 6
ORANGE WHITE/ORANGE
11
14 15 16 17 12
S1 S2 S3
Clamp Exposed shield secured under clamp.
WHITE/BLUE YELLOW WHITE/YELLOW
12 13 8
COM Refer to low-profile connector illustration (lower left) for proper grounding technique.
Clamp Screws (2) Turn clamp over to hold small cables secure.
Refer to Low Profile Connector Kit Installation Instructions, publication 2094-IN007, for connector kit specifications.
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
2090-XXNFMF-Sxx (standard) or 2090-CFBM7DF-CDAFxx (continuous-flex) (flying-lead) Feedback Cable Note 16
207
Page 208
Appendix A
Interconnect Diagrams
Figure 105 - AM Module with MP-Series Electric Cylinders MPAR-A/Bxxxxx (series B) and MPAI-A/Bxxxxx Electric Cylinders with High Resolution Feedback
IAM (inverter) or AM Module Note 15
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Cable Shield Clamp
Refer to table on page 188 for note information.
2090-K6CK-D15M Connector Kit
Shield
Note 10
Motor Power (MP) Connector
W V U
4 3 2 1
Motor Feedback (MF) Connector
D
Blue
C B
W
Black
GND V Three-phase
Brown
A
U Motor Power
Motor Feedback
Refer to Table 114 for motor power cable. Notes 16, 18
Motor/Resistive Brake (BC) Connector MBRK MBRK + COM PWR DBRK DBRK +
6
Black
5
White
4
G F
User Supplied 24V DC
3 2
BR-
1
BR+
BLACK WHITE/BLACK
1 2
3 4
SIN+ SINCOS+ COS-
RED WHITE/RED
3 4
5 6 9 10 11 13
DATA+ DATA+5VDC ECOM +9VDC TS
GREEN WHITE/GREEN
5 10 14 6 7 11
1 2
Green/Yellow
Thermostat 12
Refer to low-profile connector illustration (lower left) for proper grounding technique.
COM
Motor Brake
Refer to Table 114 for (flying-lead) motor feedback cable. Notes 16, 19, 20
Resistive Brake Connections
MPAR-A/Bxxxxx (series A) Electric Cylinders with High Resolution Feedback Grounding Technique for Feedback Cable Shield
2090-K6CK-D15M Connector Kit
2090-K6CK-D15M Low-profile Connector Kit C B
W
GND
V
Three-phase
A
U Motor Power
Motor Feedback
Clamp Screws (2) Turn clamp over to hold small cables secure.
Refer to Low Profile Connector Kit Installation Instructions, publication 2094-IN007, for connector kit specifications.
BLACK WHITE/BLACK
1 2
RED WHITE/RED
3 4
DATA+ DATA-
GREEN WHITE/GREEN
+5VDC ECOM +9VDC TS
GRAY WHITE/GRAY
5 10 14 6 7 11
G
BR-
F
BR+
3 4 5 6 9 10 11 13
ORANGE WHITE/ORANGE
14
Thermostat
12
Motor Brake
208
SIN+ SINCOS+ COS-
1 2
D
Clamp Exposed shield secured under clamp.
ORANGE WHITE/ORANGE
14
BRBR+
GRAY WHITE/GRAY
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
COM
Refer to low-profile connector illustration (left) for proper grounding technique. Refer to Table 114 for (flying-lead) motor feedback cable. Notes 16, 19, 20
Page 209
Interconnect Diagrams
Appendix A
Frame
Table 114 - MP-Series Electric Cylinder Power and Feedback Cables Power Cable Cat. No.
Feedback Cable Cat. No.
32
2090-XXNPMF-16Sxx (standard) or 2090-CPxM4DF-16AFxx (continuous-flex)
2090-XXNFMF-Sxx (standard) or 2090-CFBM4DF-CDAFxx (continuous-flex)
2090-CPxM7DF-16AAxx (standard) or 2090-CPxM7DF-16AFxx (continuous-flex)
2090-CFBM7DF-CEAAxx (standard) or 2090-CFBM7DF-CEAFxx (continuous-flex)
2090-CPxM7DF-14AAxx (standard) or 2090-CPxM7DF-14AFxx (continuous-flex)
2090-CFBM7DF-CEAAxx (standard) or 2090-CFBM7DF-CEAFxx (continuous-flex)
MP-Series Electric Cylinder Cat. No. MPAR-A/B1xxx (series A) (1) MPAR-A/B2xxx (series A)
40
MPAR-A/B1xxx (series B)
32
MPAR-A/B2xxx (series B)
40
MPAR-A/B3xxx
63
MPAI-A/B2xxxx
64
MPAI-A/B3xxxx
83
MPAI-A/B4xxxx
110
MPAI-B5xxxx
144
MPAI-A5xxxx
144
(1) Bulletin MPAR (series A) electric cylinders have threaded (M4) connectors and require threaded (M4) cable connectors.
Figure 106 - AM Module with LDAT-Series Linear Thrusters IAM (inverter) or AM Module Note 15
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Cable Shield Clamp
Shield
Note 10
Motor Power (MP) Connector
Refer to table on page 188 for note information.
LDAT-Sxxxxxx-xBx Linear Thrusters with Incremental Feedback
W V U
Motor Feedback (MF) Connector
4 3 2 1
Green/Yellow
D
Blue Black
C B
Brown
A
2090-CPWM7DF-xxAAxx (standard) or 2090-CPWM7DF-xxAFxx (continuous-flex) Motor Power Cable Notes 16, 18
2090-K6CK-D15M Connector Kit 1 2
BLACK WHITE/BLACK
1 2
RED WHITE/RED
3 4
GREEN WHITE/GREEN
GND
3 4
AM+ AMBM+ BM-
U Three-phase
5 6 9 10 11 13
IM+ IM+5VDC ECOM – TS
GRAY WHITE/GRAY
5 10 14 6
ORANGE WHITE/ORANGE
11
S1
WHITE/BLUE
S2 S3
YELLOW WHITE/YELLOW
W V
Motor Power Motor Feedback
Thermostat
14 15 16 17 12
12 13 8
COM Refer to low-profile connector illustration (lower left) for proper grounding technique.
Grounding Technique for Feedback Cable Shield
2090-XXNFMF-Sxx (standard) or 2090-CFBM7DF-CDAFxx (continuous-flex) (flying-lead) Feedback Cable Note 16
2090-K6CK-D15M Low-profile Connector Kit Clamp Exposed shield secured under clamp. Clamp Screws (2) Turn clamp over to hold small cables secure.
Refer to Low Profile Connector Kit Installation Instructions, publication 2094-IN007, for connector kit specifications.
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
209
Page 210
Appendix A
Interconnect Diagrams
Figure 107 - AM Module with LDC-Series™ or LDL-Series™ Linear Motors (cable connectors) IAM (inverter) or AM Module
LDC-Cxxxxxx-xHTx1 or LDL-xxxxxxx-xHTx1 Linear Motor Coil with Sin/Cos or TTL External Encoder and Cable Connectors
Note 15
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Cable Shield Clamp
SHIELD
Note 10
Motor Power (MP) Connector
Motor Feedback (MF) Connector
W V U
4 3 2 1
GND
GREEN/YELLOW
Thermostat
W
BLACK
C B
BROWN
A
U Motor Power
BLUE
2090-CPWM7DF-xxAAxx (standard) or 2090-CPWM7DF-xxAFxx (continuous-flex) Motor Power Cable Notes 16, 18
V Three-phase
Motor Feedback
Refer to table on page 188 for note information.
2090-K6CK-D15M Connector Kit
12 13 14 15 16 17 10 9 6 5 4 3 2 1
TS
WHT/ORANGE
11
S1 S2 S3 ECOM +5VDC IMIM+ COS- (BM-) COS+ (BM+) SIN- (AM-) SIN+ (AM+)
WHT/BLUE
12 13 8
YELLOW WHT/YELLOW
WHT/GREEN GREEN
6 14 10 5
WHT/RED RED
4 3
WHT/BLACK BLACK
2 1
WHT/GRAY GRAY
2090-XXNFMF-Sxx (standard) or 2090-CFBM7DF-CDAFxx (continuous-flex) (flying-lead) Feedback Cable Note 16 Refer to low-profile connector illustration (lower left) for proper grounding technique.
1 4 2 5 3 6 8 7
Grounding Technique for Feedback Cable Shield
SIN+ (AM+) SIN- (AM-) COS+ (BM+) COS- (BM-) IM+ IMPOWER COM
2090-K6CK-D15M Low-profile Connector Kit
Clamp Exposed shield secured under clamp. Clamp Screws (2) Turn clamp over to hold small cables secure.
Refer to Low Profile Connector Kit Installation Instructions, publication 2094-IN007, for connector kit specifications.
210
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
External Sin/Cos or (TTL) Encoder
Page 211
Interconnect Diagrams
Appendix A
Figure 108 - AM Module with LDC-Series or LDL-Series Linear Motors (flying-lead cables) IAM (inverter) or AM Module
Refer to table on page 188 for note information.
Note 15
LDC-Cxxxxxx-xHTx0 or LDL-xxxxxxx-xHTx0 Linear Motor Coil with Sin/Cos or TTL External Encoder and Flying-lead Cables
Cable Shield Clamp Note 10
Motor Power (MP) Connector
Kinetix 6000 IAM or AM Module
2090-K6CK-D15M Connector Kit
Motor Feedback (MF) Connector
4 3 2 1
W V U
GREEN/YELLOW
W V U
BLACK
W
WHITE
V
RED
U
TS+ TS-
BLACK BLACK
POWER S1 S2 S3 COM 11 12 13 8 1 2 3 4 5 10 14 6
TS+ S1 S2 S3 SIN+ (AM+) (AM-) SINCOS+ (BM+) (BM-) COSIM+ IMPOWER COM
GND
Three-phase Motor Power Thermostat
RED WHITE BLUE ORANGE
Hall Effect Module
BLACK
SIN+ (AM+) (AM-) SINCOS+ (BM+) (BM-) COSIM+ IMPOWER COM
External Sin/Cos or (TTL) Encoder
Wire as shown using cable type appropriate for your application.
Grounding Technique for Feedback Cable Shield
2090-K6CK-D15M Low-profile Connector Kit
Clamp Exposed shield secured under clamp. Clamp Screws (2) Turn clamp over to hold small cables secure.
Refer to Low Profile Connector Kit Installation Instructions, publication 2094-IN007, for connector kit specifications.
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
211
Page 212
Appendix A
Interconnect Diagrams
Kinetix 6000M Integrated Drive-Motor Wiring Example
This example applies to Kinetix 6000 drives with Kinetix 6000M integrated drive-motor (IDM) systems.
ATTENTION: When using the Kinetix 6000M IDM system, with Kinetix 6000 drives, the IPIM module only forwards the safetyfeedback monitoring signals to the adjacent (downstream) drive on the power rail. To avoid personal injury due to unexpected motion, make sure that the safety-feedback connections are fed through each drive on the power rail so that safety devices can recognize when the Kinetix 6000 drive opens the feedback contactor in the cascaded safety string. Figure 109 - IPIM Module with IDM Unit 2094-SEPM-B24-S Kinetix 6000M IPIM Module
MDF-SBxxxxx-Qx8xB-S Kinetix 6000M IDM Unit 2090-CHBIFS8-12AAxx Hybrid Cable
Cable Shield Clamp DC Bus Connector
DCDC+
Inter-module Communication Connector
SH1 42+ 42SH2 CNCN+ OUT RTN SH3 SE1 SESE2
1 2 3
Hybrid Cable Input Connector
Grey Green Brown
2 3 4 5 6 7 8 9 10 11 12
Blue White/Blue Drain White/Brown Brown White/Pink Pink Drain Orange Violet Yellow
B
B
A
A
C D
C D
8 7 9 10
8 7 9 10
4 5 6
4 5 6
2090-CNSSPxS-AAxx Network Cable
Network Cable Output Connector
TX+ RTN_RXRTN_RX+ TXREF
F2+ F2F1+ F1SE2 SESE1 24+ 24-
Safe Torque Off Connector
Enable Input Connector
EtherNet/IP Connectors (2)
212
TD+ TDRD+ RD-
+ EN –
Blue White/Brown Brown White/Blue Green
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
2090-CTHP8 Terminator
1 2 3 4
2090-CTSRP Terminator
2090-CTSRP Terminator or 2090-CNSxPxS-AAxx Network Cable to Next IDM Unit
I/O 24V+ OvertravelI/O 24V COM Registration 2 Shield
To Sensor
Digital Input Connector 2
1 2 3 4 5
I/O 24V+ Overtravel+ I/O 24V COM Registration 1 Shield
To Sensor
Digital Input Connector 3
1 2 3 4 5
I/O 24V+ Reserved I/O 24V COM Home Shield
To Sensor
To Safe Torque Off Control Circuit
To Ethernet Module or Switch
8 7 9 10
1 2 3 4 5
Digital Input Connector 1
1 +24V 2 3 COM
TX+ RTN_RX+ RTN_RXTXREF
2090-CTHP8 Terminator or 2090-CHBP8S8-12AAxx Hybrid Cable to Next IDM Unit
Network Cable Output Connector
Network Cable Input Connector
1 2 3 4 5 6 7 8 9
1 2 3 6
RX+ RTN_TXRTN_TX+ RXREF
Hybrid Cable Output Connector
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
Page 213
Interconnect Diagrams
Controlling a Brake Example
Appendix A
The relay output of the Kinetix 6000 (MBRK± BC-5 and BC-6) is suitable for directly controlling a motor brake, subject to the relay voltage limit of 30V DC, and the relay current limit as shown below. Table 115 - Brake Relay Current Limit Brake Current Value, max
Kinetix 6000 IAM/AM Module
Series A
2094-AC05-Mxx-x, 2094-AC09-M02-x, 2094-AMP5-x, 2094-AM01-x, 2094-AM02-x 2094-BC01-Mxx-x, 2094-BC02-M02-x, 2094-BMP5-x, 2094-BM01-x, 2094-BM02-x
Series B
Series C
N/A 1.0 A 3.0 A 3.0 A
2094-AC16-M03-x, 2094-AC32-M05-x, 2094-AM03-x, 2094-AM05-x
1.3 A
N/A
2094-BC04-M03-x, 2094-BC07-M05-x, 2094-BM03-x, 2094-BM05-x
3.0 A
3.0 A
Table 116 - Coil Currents Rated at <1.0 A Compatible Brake Motors/Actuators (1)
Coil Current
Compatible Brake Motors
MPL-x1510, MPL-x1520, MPL-x1530
0.43…0.53 A
TLY-A110T-H, TLY-A120T-H, and TLY-A130T-H
0.18…0.22 A
MPL-x210, MPL-x220, MPL-x230
0.46…0.56 A
TLY-A220T-H and TLY-A230T-H
0.333…0.407 A
TLY-A2530P-H, TLY-A2540P-H, and TLY-A310M-H
0.351…0.429 A
1326AB-B4xxx
0.88 A
F-4030, F-4050, and F-4075
0.69 A
MPL/MPF-x310, MPL/MPF-x320, MPL/MPF-x330
0.45…0.55 A
MPS-x330, MPM-x115, MDF-SB1003 MPL-x420, MPL-x430, MPL-x4520, MPL-x4530, MPL-x4540, MPL-x4560 MPF-x430, MPF-x4530, MPF-x4540
Coil Current
0.576…0.704 A
MPS-x4540, MPM-x130, MDF-SB1153, MDF-SB1304
Table 117 - Coil Currents Rated at >1.0 A and ≤ 1.3 A Compatible Brake Motors (1) MPL-xB520, MPL-xB540, MPL-x560, MPL-x580 MPF-x540, MPS-B560, MPM-x165
Coil Current 1.05…1.28 A
Compatible Brake Motors
Coil Current
F-6100, F-6200, and F-6300
1.30 A
1326AB-B5xxx, and 1326AB-B7xxx
1.20 A
(1) Use of the variable x indicates this specification applies to 230V and 460V motors.
Table 118 - Coil Currents Rated at >1.3 A and ≤ 3.0 A Compatible Brake Motors
Coil Current
MPL-B640, MPL-B660, MPL-B680
1.91…2.19 A
MPL-B860, MPL-B880
2.05…2.50 A
MPM-x215
1.84…2.25 A
MPL-B960, MPL-B980
N/A
IMPORTANT
Because the coil current for MPL-B960 and MPL-B980 motors is rated 3.85…4.70 A, an external relay must be used.
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
213
Page 214
Appendix A
Interconnect Diagrams
System Block Diagrams
This section provides block diagrams of the Kinetix 6000 drive modules. For block diagrams of the LIM module and RBM module, refer to Additional Resources on page 12 for the documentation available for those products.
Inverter Section
V
CTRL 2
DC-
214
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
CAN (2)
GSHUNT (2)
CONV_ID (5)
SYSOK
POWER RAIL
DC+
CTRL 1
Common Mode Choke (460V only)
Chassis
SMPS
FUSE_OK
+/-12V (Control) +24V (Customer I/O) +9V, +5V (Motor Feedback)
MBRK PWR DBRK
Motor/Resistive Brake Connections
U
Three-phase Motor Output
W
Shunt Circuit (460V only)
Motor Shield Clamp
Figure 110 - IAM/AM Module (inverter) Block Diagram
Page 215
CTRL1
EMC Filter (1)
95C
CONV_OT
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
DROK/ CONT_EN
CONT_EN1
CTRL2
CONT_EN2
Control Power AC Input
Rectifier Circuit (2)
DC-
DC+
L2
L3 Vcc
DC Link Inductor (3)
L1
DCL2
L2
L1
Three-phase AC Input
DCL1
Control Power Loss Detector
120K
Shunt Circuit (2)
DC-
DC+
(1) EMC filter present only on 460V converters. (2) Rectifier and shunt circuits present only on 230V converters. (3) Internal DC link inductor present on 460V converters. Connectors for external DC link inductor present on 230V converters. (4) Ground jumper shown in default configuration (grounded facility power).
Chassis
Ground Jumper (4)
Gnd Flt CT
Common Bus Power Connections
Vsns
GSHUNT
SYS_OK
CTRL+
CTRL-
DC-
CHASSIS
DC+
POWER RAIL
Interconnect Diagrams Appendix A
Figure 111 - IAM Module (converter) Block Diagram
215
Page 216
Appendix A
Interconnect Diagrams
Figure 112 - Shunt Module Block Diagram
DC+
POWER RAIL
Internal or External Shunt Resistor
DC-
SYSOK
Shunt Circuit CTRL 1
GSHUNT (2)
CTRL 2
SMPS +5V (Control) +/-15V (IGBT) 24V (Control)
Chassis
216
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017