Page 57

Chapter

4

Connector Data and Feature Descriptions

This chapter illustrates drive connectors and indicators, including connector pinouts, and provides descriptions for Kinetix® 6000 drive features. Topic

Page

2094 IAM/AM Module Connector Data

58

Control Signal Specifications

67

Power and Relay Specifications

71

Feedback Specifications

78

For the Kinetix 6000M integrated drive-motor (IDM) unit and IDM power interface module (IPIM) connector locations and signal descriptions, refer to the Kinetix 6000M Integrated Drive-Motor System User Manual, publication 2094-UM003.

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

57

Page 58

Chapter 4

Connector Data and Feature Descriptions

Use these illustrations to identify the connectors and indicators for the IAM/AM modules. Sercos interface and Ethernet network connectors for the Kinetix 6000M IPIM module are also shown. For the remainder of the IPIM module features and indicators, refer to the Kinetix 6000M Integrated DriveMotor System User Manual, publication 2094-UM003.

2094 IAM/AM Module Connector Data

Although the physical size of the 400V-class module is larger than the 200V-class module, the location of the features and indicators is identical. Figure 23 - Integrated Axis Module Features and Indicators

Kinetix 6000 IAM Module, Top View (2094-AC05-M01-S module is shown) CTRL 2

L2 L1

1 2

CONT ENCONT EN+

1

58

RX

MBRK MBRK + COM PWR DBRK DBRK +

DPI

1 2 3 4

U

L3

6

1 2 3 4 5 6

W V

15

Kinetix 6000 IAM Module, Front View (2094-AC05-M01-S module is shown)

CTRL 1 DCDC+

1 2 3 4 5 6 7 8 9

4 5 6

2

1 2 3

3

1 2

4

14

5

16 17 18

7

19 TX

BAUD RATE

8

13

9 10 11

12

20

Item

Description

Item

Description

1

Safe torque-off (STO) connector

11

Sercos receive (Rx) connector

2

Contactor enable (CED) connector

12

Mounting screw

3

DC bus/AC input power (IPD) connector

13

I/O (IOD) connector

4

Control power (CPD) connector

14

Sercos node address switch

5

Motor cable shield clamp

15

Seven-segment fault status indicator

6

Motor power (MP) connector

16

Drive status indicator

7

Motor/resistive brake (BC) connector

17

COMM status indicator

8

Sercos communication rate and optical power switches

18

Bus status indicator

9

Sercos transmit (Tx) connector

19

Motor feedback (MF) connector

10

DPI connector

20

Auxiliary feedback (AF) connector

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

Page 59

Connector Data and Feature Descriptions

Chapter 4

Figure 24 - Axis Module Features and Indicators

W V U 1 2 3 4 5 6 7 8 9

1

MBRK MBRK + COM PWR DBRK DBRK +

RX

TX

Kinetix 6000 AM Module, Front View (2094-AM01-S module is shown)

3

1 2 3 4 5 6

2

1 2 3 4

Kinetix 6000 AM Module, Top View (2094-AM01-S module is shown)

11 12 13 14

4 2094-SEPM-B24-S IPIM Module, Top View

BAUD RATE

15

5 10

6 7 8

16

9 2094-SEPM-B24-S IPIM Module, Bottom View

Item

Description

Item

Description

1

Safe torque-off (STO) connector

9

Mounting screw

2

Motor cable shield clamp

10

I/O (IOD) connector

3

Motor power (MP) connector

11

Seven-segment fault status indicator

4

Motor/resistive brake (BC) connector

12

Drive status indicator

5

Sercos communication rate and optical power switches

13

COMM status indicator

6

Sercos transmit (Tx) connector (1)

14

Bus status indicator

7

Sercos receive (Rx) connector (1)

15

Motor feedback (MF) connector

8

Ethernet (PORT1 and PORT 2) connectors (2)

16

Auxiliary feedback (AF) connector

(1) The Rx and Tx Sercos connectors on the Kinetix 6000M IPIM module are in the same position as on the Kinetix 6000 AM modules. For the remainder of the IPIM module features and indicators, refer to the Kinetix 6000M Integrated Drive-Motor System User Manual, publication 2094-UM003. (2) The Kinetix 6000M IPIM module has two Ethernet ports. These ports are used only for connecting to the EtherNet/IP network for Logix5000™ programming.

Table 23 - Kinetix 6000 IAM/AM Module Connectors Designator

Description

Connector

Module

IOD

User I/O (drive)

26-pin high-density D-shell (female)

IAM/AM

MF

Motor feedback

15-pin high-density D-shell (female)

IAM/AM

AF

Auxiliary feedback

15-pin high-density D-shell (male)

IAM/AM

CPD

Control input power (drive)

2-position plug/header

IAM

IPD

VAC input power (drive) and DC bus

6-position plug/header

IAM

CED

Contactor enable

2-position plug/header

IAM

MP

Motor power

4-position plug/header

IAM/AM

BC

Motor/Resistive brake

6-position plug/header

IAM/AM

STO

Safe torque-off

9-position plug/header

IAM/AM

Tx and Rx

Sercos transmit and receive

Sercos fiber-optic (2)

IAM/AM

DPI

DPI

DPI

IAM

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

59

Page 60

Chapter 4

Connector Data and Feature Descriptions

Safe Torque-off Connector Pinout Each 2094-xCxx-Mxx-S IAM module and 2094-xMxx-S AM module ships with the (9-pin) wiring-plug header and motion-allowed jumper installed in the safe torque-off (STO) connector. With the motion-allowed jumper installed, the safe torque-off feature is not used. Figure 25 - Motion-allowed Jumper

Kinetix 6000 IAM/AM Module (AM module is shown)

1

1 2

3 4

5 6

7 8

Motion-allowed Jumper 9

Safe Torque-off (STO) Connector

Wiring Plug Header

Headers in this table extend the safe torque-off (STO) connector signals for use in wiring single and multiple safe torque-off drive configurations, or to defeat (not use) the safe torque-off feature. Table 24 - IAM/AM Safe Torque-off 9-pin (STO) Connector Safe Torque-off (STO) Connector Pin

Description

Signal

1

One side of the normally-closed monitoring contact of relay 2

FDBK2+

2

Other side of the normally-closed monitoring contact of relay 2

FDBK2-

One side of the normally-closed monitoring contact of relay 1

FDBK1+

Other side of the normally-closed monitoring contact of relay 1

FDBK1-

Safety enable 2 input

SAFETY ENABLE2+

6

Return for safety enable power (both inputs)

SAFETY ENABLE-

7

Safety enable 1 input

SAFETY ENABLE1+

Power for continuous enable of the safety function, 500 mA max

24V+

Power return used for continuous enable of safety function

24V_COM

3 4 5

8 9

Applies to These STO Connector Headers

• Wiring plug header used in single-drive applications • First-drive wiring header (catalog number 2090-XNSM-W) used in multiple-drive applications

• Wiring plug header • Motion-allowed jumper

IMPORTANT

Pins STO-8 and STO-9 (24V+) are used by only the motion-allowed jumper. When wiring to the wiring-plug header, the 24V supply must come from an external source.

Refer to the Kinetix Safe Torque-off Feature Safety Reference Manual, publication GMC-RM002, for more information on wiring safe torque-off headers.

60

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

Page 61

Connector Data and Feature Descriptions

Chapter 4

I/O Connector Pinout Table 25 - IAM/AM I/O 26-pin (IOD) Connector IOD Pin

Description

Signal

IOD Pin

Description

Signal

1

Hardware enable 24V DC power supply

+24V_PWR

14

High speed registration 1 input

REG1

2

Hardware enable input

ENABLE

15

Common for registration

REG_COM

3

Common

+24V_COM

16

24V registration power

REG_24V

4

Home switch 24V DC power supply

+24V_PWR

17

High speed registration 2 input

REG2

5

Home switch input

HOME

18

Common for registration

REG_COM

6

Common

+24V_COM

19

Reserved

–

7

Positive overtravel 24V DC power supply

+24V_PWR

20

Reserved

–

8

Positive overtravel limit switch input

OT+

21

Reserved

–

9

Common

+24V_COM

22

Reserved

–

10

Negative overtravel 24V DC power supply

+24V_PWR

23

Analog output 0

DAC0

11

Negative overtravel limit switch input

OT-

24

Analog output common

DAC_COM

12

Common

+24V_COM

25

Analog output 1

DAC1

13

24V registration power

REG_24V

26

Analog output common

DAC_COM

IMPORTANT

Signals +24V_PWR and +24V_COM are a 24V DC source you can use only for the inputs listed above.

Figure 26 - Pin Orientation for 26-pin I/O (IOD) Connector

Pin 26

Pin 19 Pin 10

Pin 18 Pin 9

Pin 1

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

61

Page 62

Chapter 4

Connector Data and Feature Descriptions

Motor Feedback Connector Pinout Table 26 - Stegmann Hiperface (SRS/SRM) MF Pin

Description

Signal

MF Pin

Description

Signal

1

Sine differential input+

SIN+

9

Reserved

–

2

Sine differential input-

SIN-

10

Hiperface data channel

DATATS+

3

Cosine differential input+

COS+

11

Motor thermal switch (normally closed) (2)

4

Cosine differential input-

COS-

12

Reserved

–

5

Hiperface data channel

DATA+

13

Reserved

–

6

Common

ECOM

14

Encoder power (+5V)

EPWR_5V (1)

7

Encoder power (+9V)

EPWR_9V (1)

15

Reserved

–

8

Reserved

–

(1) Determine which power supply your encoder requires and connect to only the specified supply. Do not make connections to both. (2) Not applicable unless the motor has integrated thermal protection. Common (TS-) signal for thermal switch is tied to MF-6 (ECOM) in Bulletin 2090 cables.

Table 27 - TTL or Sine/Cosine with Index Pulse and Hall Commutation MF Pin

Description

Signal

MF Pin

Description

Signal

1

AM+ / Sine differential input+

AM+ / SIN+

9

Reserved

–

2

AM- / Sine differential input-

AM- / SIN-

10

Index pulse-

IMTS+

3

BM+ / Cosine differential input+

BM+ / COS+

11

Motor thermal switch (normally closed) (2)

4

BM- / Cosine differential input-

BM- / COS-

12

Single-ended 5V hall effect commutation

S1

5

Index pulse+

IM+

13

Single-ended 5V hall effect commutation

S2

6

Common

ECOM

14

Encoder power (+5V)

EPWR_5V (1)

7

Encoder power (+9V)

EPWR_9V (1)

15

Reserved

–

8

Single-ended 5V hall effect commutation

S3

(1) Determine which power supply your encoder requires and connect to only the specified supply. Do not make connections to both. (2) Not applicable unless the motor has integrated thermal protection. Common (TS-) signal for thermal switch is tied to MF-6 (ECOM) in Bulletin 2090 cables.

ATTENTION: To avoid damage to components, determine which power supply your encoder requires and connect to either the 5V or 9V supply, but not both. Table 28 - Resolver Transmitter (transformation ratio = 0.25) MF Pin

Description

Signal

MF Pin

Description

Signal

1

Sine differential input+

S2

9

Reserved

–

2

Sine differential input-

S4

10

Resolver excitation

R2 TS+

3

Cosine differential input+

S1

11

Motor thermal switch (normally closed) (1) (2)

4

Cosine differential input-

S3

12

Reserved

–

5

Resolver excitation

R1

13

Reserved

–

6

Common

ECOM

14

Reserved

–

7

Reserved

–

15

Reserved

–

8

Reserved

–

(1) Not applicable unless the motor has integrated thermal protection. Common (TS-) signal for thermal switch is tied to MF-6 (ECOM) in Bulletin 2090 cables. (2) If using 1326AB (resolver-based) motors, use 2090-K6CK-D15MF Low-profile Connector Kits that connect the filtered thermal switch (pins 16 and 17) to MF-11 and MF-6.

62

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

Page 63

Connector Data and Feature Descriptions

Chapter 4

Kinetix 6000 drives do not support Heidenhain EnDat high-resolution feedback; however, you can use the 2090-K6CK-KENDAT feedback module to convert Heidenhain EnDat high-resolution feedback to Stegmann Hiperface. Pin numbers in the table below refer to pins in the feedback module. IMPORTANT

Only 2094-xCxx-Mxx-S and 2094-xMxx-S drives with firmware revision 1.116 or later support the use of 2090-K6CK-KENDAT feedback modules for Heidenhain EnDat feedback.

Table 29 - Heidenhain EnDat Pin

Description

Signal

Pin

Description

Signal

1

Sine differential input+

SIN+

8

Serial data clock signal -

CLK-

2

Sine differential input-

SIN-

9

Serial data differential signal+

DATA+

3

Cosine differential input+

COS+

10

Serial data differential signal -

DATA-

11

Motor thermal switch+ (1)

TS+ TS–

4

Cosine differential input-

COS-

5

Encoder power (+5V)

EPWR_5V

12

Motor thermal switch- (2)

6

Common

ECOM

13

Reserved

7

Serial data clock signal +

CLK+

(1) Not applicable unless the motor has integrated thermal protection. (2) When used with Allen-Bradley® motors and Bulletin 2090 cables, pin 12 is reserved.

IMPORTANT

Combined motor-power cable length for all axes on the same DC bus must not exceed 240 m (787 ft) with 460V systems or 160 m (525 ft) with 230V systems. Drive-to-motor power cables must not exceed 90 m (295.5 ft). System performance was tested at these cable length specifications. These limitations also apply when meeting CE requirements.

Figure 27 - Pin Orientation for 15-pin Motor Feedback (MF) Connector

Pin 15 Pin 11 Pin 6

Pin 10 Pin 5 Pin 1

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

63

Page 64

Chapter 4

Connector Data and Feature Descriptions

Auxiliary Feedback Connector Pinout For TTL devices, the position count increases when A leads B. For sinusoidal devices, the position count increases when cosine leads sine. Table 30 - Stegmann Hiperface (SRS and SRM only) AF Pin

Description

Signal

AF Pin

Description

Signal

1

Sine differential input+

SIN+

9

Reserved

–

2

Sine differential input-

SIN-

10

Hiperface data channel

DATA-

3

Cosine differential input+

COS+

11

Reserved

–

4

Cosine differential input-

COS-

12

Reserved

–

5

Hiperface data channel

DATA+

13

Reserved

–

6

Common

ECOM

14

Encoder power (+5V)

EPWR_5V (1)

7

Encoder power (+9V)

EPWR_9V (1)

15

Reserved

–

8

Reserved

–

(1) Determine which power supply your encoder requires and connect to only the specified supply. Do not make connections to both.

Table 31 - TTL or Sine/Cosine with Index Pulse AF Pin

Description

Signal

AF Pin

Description

Signal

1

A+ / Sine differential input+

A+ / SIN+

9

Reserved

–

2

A- / Sine differential input-

A- / SIN-

10

Index pulse-

I-

3

B+ / Cosine differential input+

B+ / COS+

11

Reserved

–

4

B- / Cosine differential input-

B- / COS-

12

Reserved

–

5

Index pulse+

I+

13

Reserved

–

6

Common

ECOM

14

Encoder power (+5V)

EPWR_5V (1)

7

Encoder power (+9V)

EPWR_9V (1)

15

Reserved

–

8

Reserved

–

(1) Determine which power supply your encoder requires and connect to only the specified supply. Do not make connections to both.

ATTENTION: To avoid damage to components, determine which power supply your encoder requires and connect to either the 5V or 9V supply, but not both.

Figure 28 - Pin Orientation for 15-pin Auxiliary Feedback (AF) Connector Pin 6 Pin 11 Pin 15

64

Pin 1 Pin 5 Pin 10

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

Page 65

Connector Data and Feature Descriptions

Chapter 4

IAM Input Connector Pinout Table 32 - Control Power Connector CPD Pin 1 2

Description Control power VAC input

Signal CTRL 2 CTRL 1

Table 33 - DC Bus and Input Power Connector IPD Pin

Description

Signal

1

DC-

2

An integral, unregulated power supply, consisting of AC line input, three-phase bridge rectifier, and filter capacitors.

3

Chassis ground.

4 5

DC+

L3 Three-phase input power.

6

L2 L1

Table 34 - Contactor Enable Connector CED Pin

Description

Signal

1

Relay-driven dry contact used in the control string for a threephase power contactor.

CONT EN-

2

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

CONT EN+