Page 57
Chapter
4
Connector Data and Feature Descriptions
This chapter illustrates drive connectors and indicators, including connector pinouts, and provides descriptions for Kinetix® 6000 drive features. Topic
Page
2094 IAM/AM Module Connector Data
58
Control Signal Specifications
67
Power and Relay Specifications
71
Feedback Specifications
78
For the Kinetix 6000M integrated drive-motor (IDM) unit and IDM power interface module (IPIM) connector locations and signal descriptions, refer to the Kinetix 6000M Integrated Drive-Motor System User Manual, publication 2094-UM003.
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
57
Page 58
Chapter 4
Connector Data and Feature Descriptions
Use these illustrations to identify the connectors and indicators for the IAM/AM modules. Sercos interface and Ethernet network connectors for the Kinetix 6000M IPIM module are also shown. For the remainder of the IPIM module features and indicators, refer to the Kinetix 6000M Integrated DriveMotor System User Manual, publication 2094-UM003.
2094 IAM/AM Module Connector Data
Although the physical size of the 400V-class module is larger than the 200V-class module, the location of the features and indicators is identical. Figure 23 - Integrated Axis Module Features and Indicators
Kinetix 6000 IAM Module, Top View (2094-AC05-M01-S module is shown) CTRL 2
L2 L1
1 2
CONT ENCONT EN+
1
58
RX
MBRK MBRK + COM PWR DBRK DBRK +
DPI
1 2 3 4
U
L3
6
1 2 3 4 5 6
W V
15
Kinetix 6000 IAM Module, Front View (2094-AC05-M01-S module is shown)
CTRL 1 DCDC+
1 2 3 4 5 6 7 8 9
4 5 6
2
1 2 3
3
1 2
4
14
5
16 17 18
7
19 TX
BAUD RATE
8
13
9 10 11
12
20
Item
Description
Item
Description
1
Safe torque-off (STO) connector
11
Sercos receive (Rx) connector
2
Contactor enable (CED) connector
12
Mounting screw
3
DC bus/AC input power (IPD) connector
13
I/O (IOD) connector
4
Control power (CPD) connector
14
Sercos node address switch
5
Motor cable shield clamp
15
Seven-segment fault status indicator
6
Motor power (MP) connector
16
Drive status indicator
7
Motor/resistive brake (BC) connector
17
COMM status indicator
8
Sercos communication rate and optical power switches
18
Bus status indicator
9
Sercos transmit (Tx) connector
19
Motor feedback (MF) connector
10
DPI connector
20
Auxiliary feedback (AF) connector
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
Page 59
Connector Data and Feature Descriptions
Chapter 4
Figure 24 - Axis Module Features and Indicators
W V U 1 2 3 4 5 6 7 8 9
1
MBRK MBRK + COM PWR DBRK DBRK +
RX
TX
Kinetix 6000 AM Module, Front View (2094-AM01-S module is shown)
3
1 2 3 4 5 6
2
1 2 3 4
Kinetix 6000 AM Module, Top View (2094-AM01-S module is shown)
11 12 13 14
4 2094-SEPM-B24-S IPIM Module, Top View
BAUD RATE
15
5 10
6 7 8
16
9 2094-SEPM-B24-S IPIM Module, Bottom View
Item
Description
Item
Description
1
Safe torque-off (STO) connector
9
Mounting screw
2
Motor cable shield clamp
10
I/O (IOD) connector
3
Motor power (MP) connector
11
Seven-segment fault status indicator
4
Motor/resistive brake (BC) connector
12
Drive status indicator
5
Sercos communication rate and optical power switches
13
COMM status indicator
6
Sercos transmit (Tx) connector (1)
14
Bus status indicator
7
Sercos receive (Rx) connector (1)
15
Motor feedback (MF) connector
8
Ethernet (PORT1 and PORT 2) connectors (2)
16
Auxiliary feedback (AF) connector
(1) The Rx and Tx Sercos connectors on the Kinetix 6000M IPIM module are in the same position as on the Kinetix 6000 AM modules. For the remainder of the IPIM module features and indicators, refer to the Kinetix 6000M Integrated Drive-Motor System User Manual, publication 2094-UM003. (2) The Kinetix 6000M IPIM module has two Ethernet ports. These ports are used only for connecting to the EtherNet/IP network for Logix5000™ programming.
Table 23 - Kinetix 6000 IAM/AM Module Connectors Designator
Description
Connector
Module
IOD
User I/O (drive)
26-pin high-density D-shell (female)
IAM/AM
MF
Motor feedback
15-pin high-density D-shell (female)
IAM/AM
AF
Auxiliary feedback
15-pin high-density D-shell (male)
IAM/AM
CPD
Control input power (drive)
2-position plug/header
IAM
IPD
VAC input power (drive) and DC bus
6-position plug/header
IAM
CED
Contactor enable
2-position plug/header
IAM
MP
Motor power
4-position plug/header
IAM/AM
BC
Motor/Resistive brake
6-position plug/header
IAM/AM
STO
Safe torque-off
9-position plug/header
IAM/AM
Tx and Rx
Sercos transmit and receive
Sercos fiber-optic (2)
IAM/AM
DPI
DPI
DPI
IAM
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
59
Page 60
Chapter 4
Connector Data and Feature Descriptions
Safe Torque-off Connector Pinout Each 2094-xCxx-Mxx-S IAM module and 2094-xMxx-S AM module ships with the (9-pin) wiring-plug header and motion-allowed jumper installed in the safe torque-off (STO) connector. With the motion-allowed jumper installed, the safe torque-off feature is not used. Figure 25 - Motion-allowed Jumper
Kinetix 6000 IAM/AM Module (AM module is shown)
1
1 2
3 4
5 6
7 8
Motion-allowed Jumper 9
Safe Torque-off (STO) Connector
Wiring Plug Header
Headers in this table extend the safe torque-off (STO) connector signals for use in wiring single and multiple safe torque-off drive configurations, or to defeat (not use) the safe torque-off feature. Table 24 - IAM/AM Safe Torque-off 9-pin (STO) Connector Safe Torque-off (STO) Connector Pin
Description
Signal
1
One side of the normally-closed monitoring contact of relay 2
FDBK2+
2
Other side of the normally-closed monitoring contact of relay 2
FDBK2-
One side of the normally-closed monitoring contact of relay 1
FDBK1+
Other side of the normally-closed monitoring contact of relay 1
FDBK1-
Safety enable 2 input
SAFETY ENABLE2+
6
Return for safety enable power (both inputs)
SAFETY ENABLE-
7
Safety enable 1 input
SAFETY ENABLE1+
Power for continuous enable of the safety function, 500 mA max
24V+
Power return used for continuous enable of safety function
24V_COM
3 4 5
8 9
Applies to These STO Connector Headers
• Wiring plug header used in single-drive applications • First-drive wiring header (catalog number 2090-XNSM-W) used in multiple-drive applications
• Wiring plug header • Motion-allowed jumper
IMPORTANT
Pins STO-8 and STO-9 (24V+) are used by only the motion-allowed jumper. When wiring to the wiring-plug header, the 24V supply must come from an external source.
Refer to the Kinetix Safe Torque-off Feature Safety Reference Manual, publication GMC-RM002, for more information on wiring safe torque-off headers.
60
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
Page 61
Connector Data and Feature Descriptions
Chapter 4
I/O Connector Pinout Table 25 - IAM/AM I/O 26-pin (IOD) Connector IOD Pin
Description
Signal
IOD Pin
Description
Signal
1
Hardware enable 24V DC power supply
+24V_PWR
14
High speed registration 1 input
REG1
2
Hardware enable input
ENABLE
15
Common for registration
REG_COM
3
Common
+24V_COM
16
24V registration power
REG_24V
4
Home switch 24V DC power supply
+24V_PWR
17
High speed registration 2 input
REG2
5
Home switch input
HOME
18
Common for registration
REG_COM
6
Common
+24V_COM
19
Reserved
–
7
Positive overtravel 24V DC power supply
+24V_PWR
20
Reserved
–
8
Positive overtravel limit switch input
OT+
21
Reserved
–
9
Common
+24V_COM
22
Reserved
–
10
Negative overtravel 24V DC power supply
+24V_PWR
23
Analog output 0
DAC0
11
Negative overtravel limit switch input
OT-
24
Analog output common
DAC_COM
12
Common
+24V_COM
25
Analog output 1
DAC1
13
24V registration power
REG_24V
26
Analog output common
DAC_COM
IMPORTANT
Signals +24V_PWR and +24V_COM are a 24V DC source you can use only for the inputs listed above.
Figure 26 - Pin Orientation for 26-pin I/O (IOD) Connector
Pin 26
Pin 19 Pin 10
Pin 18 Pin 9
Pin 1
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
61
Page 62
Chapter 4
Connector Data and Feature Descriptions
Motor Feedback Connector Pinout Table 26 - Stegmann Hiperface (SRS/SRM) MF Pin
Description
Signal
MF Pin
Description
Signal
1
Sine differential input+
SIN+
9
Reserved
–
2
Sine differential input-
SIN-
10
Hiperface data channel
DATATS+
3
Cosine differential input+
COS+
11
Motor thermal switch (normally closed) (2)
4
Cosine differential input-
COS-
12
Reserved
–
5
Hiperface data channel
DATA+
13
Reserved
–
6
Common
ECOM
14
Encoder power (+5V)
EPWR_5V (1)
7
Encoder power (+9V)
EPWR_9V (1)
15
Reserved
–
8
Reserved
–
(1) Determine which power supply your encoder requires and connect to only the specified supply. Do not make connections to both. (2) Not applicable unless the motor has integrated thermal protection. Common (TS-) signal for thermal switch is tied to MF-6 (ECOM) in Bulletin 2090 cables.
Table 27 - TTL or Sine/Cosine with Index Pulse and Hall Commutation MF Pin
Description
Signal
MF Pin
Description
Signal
1
AM+ / Sine differential input+
AM+ / SIN+
9
Reserved
–
2
AM- / Sine differential input-
AM- / SIN-
10
Index pulse-
IMTS+
3
BM+ / Cosine differential input+
BM+ / COS+
11
Motor thermal switch (normally closed) (2)
4
BM- / Cosine differential input-
BM- / COS-
12
Single-ended 5V hall effect commutation
S1
5
Index pulse+
IM+
13
Single-ended 5V hall effect commutation
S2
6
Common
ECOM
14
Encoder power (+5V)
EPWR_5V (1)
7
Encoder power (+9V)
EPWR_9V (1)
15
Reserved
–
8
Single-ended 5V hall effect commutation
S3
(1) Determine which power supply your encoder requires and connect to only the specified supply. Do not make connections to both. (2) Not applicable unless the motor has integrated thermal protection. Common (TS-) signal for thermal switch is tied to MF-6 (ECOM) in Bulletin 2090 cables.
ATTENTION: To avoid damage to components, determine which power supply your encoder requires and connect to either the 5V or 9V supply, but not both. Table 28 - Resolver Transmitter (transformation ratio = 0.25) MF Pin
Description
Signal
MF Pin
Description
Signal
1
Sine differential input+
S2
9
Reserved
–
2
Sine differential input-
S4
10
Resolver excitation
R2 TS+
3
Cosine differential input+
S1
11
Motor thermal switch (normally closed) (1) (2)
4
Cosine differential input-
S3
12
Reserved
–
5
Resolver excitation
R1
13
Reserved
–
6
Common
ECOM
14
Reserved
–
7
Reserved
–
15
Reserved
–
8
Reserved
–
(1) Not applicable unless the motor has integrated thermal protection. Common (TS-) signal for thermal switch is tied to MF-6 (ECOM) in Bulletin 2090 cables. (2) If using 1326AB (resolver-based) motors, use 2090-K6CK-D15MF Low-profile Connector Kits that connect the filtered thermal switch (pins 16 and 17) to MF-11 and MF-6.
62
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
Page 63
Connector Data and Feature Descriptions
Chapter 4
Kinetix 6000 drives do not support Heidenhain EnDat high-resolution feedback; however, you can use the 2090-K6CK-KENDAT feedback module to convert Heidenhain EnDat high-resolution feedback to Stegmann Hiperface. Pin numbers in the table below refer to pins in the feedback module. IMPORTANT
Only 2094-xCxx-Mxx-S and 2094-xMxx-S drives with firmware revision 1.116 or later support the use of 2090-K6CK-KENDAT feedback modules for Heidenhain EnDat feedback.
Table 29 - Heidenhain EnDat Pin
Description
Signal
Pin
Description
Signal
1
Sine differential input+
SIN+
8
Serial data clock signal -
CLK-
2
Sine differential input-
SIN-
9
Serial data differential signal+
DATA+
3
Cosine differential input+
COS+
10
Serial data differential signal -
DATA-
11
Motor thermal switch+ (1)
TS+ TS–
4
Cosine differential input-
COS-
5
Encoder power (+5V)
EPWR_5V
12
Motor thermal switch- (2)
6
Common
ECOM
13
Reserved
7
Serial data clock signal +
CLK+
(1) Not applicable unless the motor has integrated thermal protection. (2) When used with Allen-Bradley® motors and Bulletin 2090 cables, pin 12 is reserved.
IMPORTANT
Combined motor-power cable length for all axes on the same DC bus must not exceed 240 m (787 ft) with 460V systems or 160 m (525 ft) with 230V systems. Drive-to-motor power cables must not exceed 90 m (295.5 ft). System performance was tested at these cable length specifications. These limitations also apply when meeting CE requirements.
Figure 27 - Pin Orientation for 15-pin Motor Feedback (MF) Connector
Pin 15 Pin 11 Pin 6
Pin 10 Pin 5 Pin 1
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
63
Page 64
Chapter 4
Connector Data and Feature Descriptions
Auxiliary Feedback Connector Pinout For TTL devices, the position count increases when A leads B. For sinusoidal devices, the position count increases when cosine leads sine. Table 30 - Stegmann Hiperface (SRS and SRM only) AF Pin
Description
Signal
AF Pin
Description
Signal
1
Sine differential input+
SIN+
9
Reserved
–
2
Sine differential input-
SIN-
10
Hiperface data channel
DATA-
3
Cosine differential input+
COS+
11
Reserved
–
4
Cosine differential input-
COS-
12
Reserved
–
5
Hiperface data channel
DATA+
13
Reserved
–
6
Common
ECOM
14
Encoder power (+5V)
EPWR_5V (1)
7
Encoder power (+9V)
EPWR_9V (1)
15
Reserved
–
8
Reserved
–
(1) Determine which power supply your encoder requires and connect to only the specified supply. Do not make connections to both.
Table 31 - TTL or Sine/Cosine with Index Pulse AF Pin
Description
Signal
AF Pin
Description
Signal
1
A+ / Sine differential input+
A+ / SIN+
9
Reserved
–
2
A- / Sine differential input-
A- / SIN-
10
Index pulse-
I-
3
B+ / Cosine differential input+
B+ / COS+
11
Reserved
–
4
B- / Cosine differential input-
B- / COS-
12
Reserved
–
5
Index pulse+
I+
13
Reserved
–
6
Common
ECOM
14
Encoder power (+5V)
EPWR_5V (1)
7
Encoder power (+9V)
EPWR_9V (1)
15
Reserved
–
8
Reserved
–
(1) Determine which power supply your encoder requires and connect to only the specified supply. Do not make connections to both.
ATTENTION: To avoid damage to components, determine which power supply your encoder requires and connect to either the 5V or 9V supply, but not both.
Figure 28 - Pin Orientation for 15-pin Auxiliary Feedback (AF) Connector Pin 6 Pin 11 Pin 15
64
Pin 1 Pin 5 Pin 10
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
Page 65
Connector Data and Feature Descriptions
Chapter 4
IAM Input Connector Pinout Table 32 - Control Power Connector CPD Pin 1 2
Description Control power VAC input
Signal CTRL 2 CTRL 1
Table 33 - DC Bus and Input Power Connector IPD Pin
Description
Signal
1
DC-
2
An integral, unregulated power supply, consisting of AC line input, three-phase bridge rectifier, and filter capacitors.
3
Chassis ground.
4 5
DC+
L3 Three-phase input power.
6
L2 L1
Table 34 - Contactor Enable Connector CED Pin
Description
Signal
1
Relay-driven dry contact used in the control string for a threephase power contactor.
CONT EN-
2
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
CONT EN+