For the Allen-Bradley 2094-BM01 and Allen-Bradley 2094-PRF

Page 110

Chapter 5

Connect the Kinetix 6000 Drive System

These cables contain three-phase power wires and brake wires. The brake wires have a shield braid (shown below as gray) that folds back under the cable clamp before the conductors are attached to the motor brake (BC) connector. Thermal switch wires are included in the feedback cable. Refer to Axis Module/Rotary Motor Wiring Examples beginning on page 198 for interconnect diagrams. Figure 58 - Motor Power Terminations (cables with brake wires)

Motor Cable Shield Clamp

MP-Series Cable Brake Wires

Kinetix 6000 IAM/AM Module (IAM module is shown)

DCDC+

W V U

L3 L2 L1

1 2 3 4

CTRL 2 CTRL 1

CONT ENCONT EN+

RX

DPI

1 2 3 4 5 6

MBRK MBRK + COM PWR DBRK DBRK +

Motor Power (MP) Connector

TX

Resistive/Motor Brake (BC) Connector

BAUD RATE

The cable shield clamp shown above is mounted to an IAM module. Cables attach to the clamp on each AM module in the same way.

110

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

Page 111

Connect the Kinetix 6000 Drive System

Chapter 5

The 1326AB (resolver) power cables (catalog number 1326-CPx1T-L-xxx) contain the three-phase wires, brake wires, and thermal switch wires. To improve the EMC performance of your system, route the wires as shown. Refer to Axis Module/Rotary Motor Wiring Examples beginning on page 198 for interconnect diagrams. Figure 59 - Motor Power Terminations (1326-CPx1T-L-xxx cable) MF-16 MF-17

Thermal Switch Wires

MF-S Terminal Block (mounted on DIN rail) Refer to page 35 for treatment of painted panels.

Motor Cable Shield Clamp

Thermal Switch Wires

Kinetix 6000 IAM/AM Module (IAM module is shown)

DCDC+

W V U

L3 L2 L1

MBRK MBRK + COM PWR DBRK DBRK +

CONT ENCONT EN+

Keep wires separated as much as possible.

1 2 3 4

CTRL 1 CTRL 2

RX

DPI

Motor Power (MP) Connector 1 2 3 4 5 6

Low-profile motor feedback connector (2090-K6CK-D15MF) pins 16, 17, and S provide filtering for 1326-CPx1T-L-xxx cables (refer to page 126 for an illustration).

TX

Resistive/Motor Brake (BC) Connector BAUD RATE

The cable shield clamp shown above is mounted to an IAM module. Cables attach to the clamp on each AM module in the same way. IMPORTANT

We recommend securing the cable shield in the clamp with a tie wrap to improve stress relief.

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

111

Page 112

Chapter 5

Connect the Kinetix 6000 Drive System

Cable shield and lead preparation is provided with most Allen-Bradley® cable assemblies. Follow these guidelines if your motor power cable shield and wires require preparation. Figure 60 - Cable Shield and Lead Preparation Strip Length (see table below)

U Outer Insulation

V W

Motor Power Cable Exposed Braid 25.4 mm (1.0 in.)

105 mm (4.1 in.) 130 mm (5.1 in.)

Refer to Axis Module/Rotary Motor Wiring Examples beginning on page 198 for interconnect diagrams. Table 74 - Motor Power (MP) Connector Servo Motor

MP Connector (IAM/AM module)

1326AB (resolver)

All Other Motors

MP Pin

Signal

1 / Black

U / Brown

1

U

2 / Black

V / Black

2

V

3 / Black

W / Blue

3

W

Green/Yellow

Green/Yellow

4

Table 75 - Termination Specifications IAM/AM Module Cat. No. 2094-AC05-Mxx-x, 2094-AMP5-x, 2094-AM01-x, 2094-AC09-M02-x, 2094-AM02-x, 2094-BC01-Mxx-x, 2094-BMP5-x, 2094-BM01-x 2094-BC02-M02-x, 2094-BM02-x

112

Recommended Wire Size mm2 (AWG)

Strip Length mm (in.)

Motor power cable depends on motor/ drive combination. 10 (0.38)

Torque Value N•m (lb•in)

0.5…0.6 (4.4…5.3)

6 (10) max

2094-AC16-M03-x, 2094-AM03-x 2094-AC32-M05-x, 2094-AM05-x

10 (8) max

10 (0.38)

1.2…1.5 (10.6…13.2)

2094-BC04-M03-x, 2094-BM03-x

10 (8) max

10 (0.38)

1.2…1.5 (10.6…13.2)

2094-BC07-M05-x, 2094-BM05-x

30 (3) max

16 (0.63)

2.4…3.0 (21.6…26.5)

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

Page 113

Connect the Kinetix 6000 Drive System

Chapter 5

Wire the Motor/Resistive Brake (BC) Connector This example applies to AM modules and the inverter section of IAM modules. Figure 61 - IAM/AM Module (BC connector)

KMBR K+ B MR COM R PW KDBR K+ DBR

1

2

3

4

5

6

Kinetix 6000 IAM/AM Module (IAM module is shown)

Motor/Resistive Brake (BC) Connector

24V DC Brake Input Power Connections IMPORTANT

If your system includes a LIM module, you can source the 24V DC from the LIM module (P1L or PSL connector).

Table 76 - Motor/Resistive Brake (BC) Connector 2094-ALxxS, 2094-BLxxS, or 2094-XL75S-Cx LIM Module

2094-AL09 and 2094-BL02 LIM Module

BC Connector (IAM/AM modules)

P1L Pin

Signal

PSL Pin

Signal

BC Pin

Signal

1

IO_PWR2

1

MBRK PWR

3

PWR

2

IO_COM2

2

MBRK COM

4

COM

RBM Module Connections Table 77 - Motor/Resistive Brake (BC) Connector RBM Module I/O Connections

BC Connector (IAM/AM modules)

TB3 Pin

Signal

MP Pin

Signal (1)

6

COIL_A1

1

DBRK+

7

COIL_A2

2

DBRK-

(1) Firmware revision 1.071 or later is required to use the DBRK outputs on the Kinetix 6000 IAM/AM module.

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

113

Page 114

Chapter 5

Connect the Kinetix 6000 Drive System

Motor Brake Connections The procedure for wiring your motor brake varies slightly, depending on the motor family. The cables compatible with your motor or actuator depend on the connectors installed on the motor or actuator. Refer to MP-Series Motor and Actuator Connectors on page 107 for more information on circular DIN and bayonet connectors. Table 78 - Motor Brake Cable Compatibility - Bayonet Connectors Motor Series MPL-A/B3xxx-xx2xAA, MPL-A/B4xxx-xx2xAA, MPL-A/B45xxx-xx2xAA, MPL-A/B5xxx-xx2xAA, MPL-B6xxx-xx2xAA, MPL-B8xxx-xx2xAA, MPL-B9xxx-xx2xAA

Connector Type

Brake Wires

Cable Cat. No.

Bayonet

The motor has a brake connector. Brake wires are in the brake cable.

2090-UXxBMP-18Sxx brake cable (1)

P-LOK

The motor has a brake connector. Brake wires are in the brake cable.

1326AB (M2L/S2L) F-Series 1326AB (resolver)

Straight brake connector kit 9101-0330 1326-CPx1T-L-xxx power cable

(1) For Bulletin MPL and 1326AB motors equipped with bayonet connectors. These cables are available as standard (catalog number 2090-UXNBMP-18Sxx) and continuous-flex (catalog number 2090-UXTBMP-18Sxx).

Table 79 - Motor Brake Cable Compatibility - Threaded DIN and Circular Plastic Connectors Connector Type

Brake Wires

Cable Cat. No.

MPS-A/Bxxx, MPAS-A/Bxxx, MPMA-A/Bxxx, MPAR-A/B1xxx, MPAR-A/B2xxx (series A)

Circular (threaded) DIN

The motor/actuator does not have a brake connector. Brake wires are included in the power cable.

2090-XXNPMF-xxSxx (standard) or 2090-CPBM4DF-xxAFxx (continuous-flex)

TLY-Axxxx-H

Circular Plastic

The motor/actuator does not have a brake connector. Brake wires are included in the power cable.

2090-CPBM6DF-16AAxx power cable

Motor Series MPL-A/B15xxx-xx4xAA, MPL-A/B2xxx-xx4xAA

Table 80 - Motor Brake Cable Compatibility - SpeedTec DIN Connectors Connector Type

Motor Series

Brake Wires

Cable Cat. No. (1)

MPL-A/B15xxx-xx7xAA, MPL-A/B2xxx-xx7xAA MPL-A/B3xxx-xx7xAA, MPL-A/B4xxx-xx7xAA, MPL-A/B45xxx-xx7xAA, MPL-A/B5xxx-xx7xAA, MPL-B6xxx-xx7xAA, MPL-B8xxx-xx7xAA MPL-B9xxx-xx7xAA

The motor/actuator does not Circular have a brake connector. (SpeedTec) DIN Brake wires are included in the power cable.

MPM-A/Bxxx, MPF-A/Bxxx, MPS-A/Bxxx

2090-CPBM7DF-xxAAxx (standard) or 2090-CPBM7DF-xxAFxx (continuous-flex)

MPAS-A/Bxxx, MPAR-A/B1xxx, MPAR-A/B2xxx (series B), MPAR-A/B3xxx, MPAI-A/Bxxx (1) You must remove the motor-side o-ring when using 2090-CFBM7xx-xxAxxx cables.

IMPORTANT

114

Use surge suppression when controlling a brake coil. Refer to Controlling a Brake Example on page 213.

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

Page 115

Connect the Kinetix 6000 Drive System

Chapter 5

Figure 62 - Brake Cable Preparation Outer Insulation Strip Length 10 mm (0.375 in.) Brake Cable 105 mm (4.1 in.)

Table 81 - Motor/Resistive Brake (BC) Connector BC Connector (IAM/AM module)

Motor Brake Wires 2090-UXxBMP-18Sxx Brake Cable

2090-XXNPMF-xxSxx 2090-CPBMxDF-xxAFxx Power Cable

2090-CPBM6DF-16AAxx Power Cable

1326-CPx1T-L-xxx Power Cable

BC Pin

Signal

A / BR+

F/+ / BR+/MBRK+

7 / MBRK+

6 / B1

5

MBRK+

C / BR-

G/- / BR-/MBRK-

9 / MBRK-

4 / B2

6

MBRK-

Recommended Wire Size mm2 (AWG)

Strip Length mm (in.)

Torque Value N•m (lb•in)

0.75 (18)

10 (0.38)

0.22…0.25 (1.9…2.2)

Table 82 - Termination Specifications BC Connector (IAM/AM module) BC Pin

Signal

BC-6 BC-5 BC-4 BC-3 BC-2 BC-1

MBRKMBRK+ COM PWR DBRKDBRK+

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

115

Page 116

Chapter 5

Connect the Kinetix 6000 Drive System

Apply the Motor Cable Shield Clamp

This procedure assumes you have completed wiring your motor power (MP) connector and are ready to apply the cable shield clamp. TIP

Your drive can be equipped with either the pivot-open or slide-open cable clamp.

Follow these steps to apply the motor cable shield clamp. 1. Depress the spring loaded clamp. Screwdriver Tip 3.5 mm (0.14 in.)

The pivot-open cable clamp was designed to replace the slide-open cable clamp. Pivot-open clamp features include: • Screwdriver not required for depressing the spring • Tie wrap not required or recommended

Pry clamp back with thumb.

Screwdriver Tip in Slot Pivot-open Cable Clamp

Slide-open Cable Clamp

2. Position the exposed portion of the cable braid directly in line with the clamp. 3. Release the spring, making sure the cable and cable braid are held secure by the clamp. 4. Attach tie wrap (slide-open clamp only) around cable and clamp for additional strain relief.

Exposed Braid (under clamp)

Motor Cable

Outer Insulation Horizontal Cable Clamp Orientation Examples Cable Clamp Outer Insulation

Tie Wrap

Slide-open Cable Clamp Exposed Braid (under clamp)

Vertical Cable Clamp Orientation Example Motor Cable

Vent holes on top of IAM/AM module. Outer Insulation

Exposed Braid (under clamp)

Motor Cable Pivot-open Cable Clamp

Vent holes on top of IAM/AM module.

5. Repeat step 1 through step 4 for each IAM, AM, or IPIM module.

116

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

Page 117

Connect the Kinetix 6000 Drive System

Chapter 5

Factory made cables with premolded connectors are designed to minimize EMI and are recommended over hand-built cables to improve system performance. However, other options are available for building your own feedback and I/O cables.

Feedback and I/O Cable Connections

Table 83 - Options for Connecting Motor Feedback and I/O Connection Option

Connector Kit Cat. No.

Cable

Using this Type of Cable

Premolded connector

N/A

Motor feedback

2090-K6CK-D15M

Motor feedback

Refer to Table 84 and Table 85 for the flying-lead cable available for your motor.

2090-K6CK-D26M

I/O interface

User-supplied flying-lead cable.

2090-K6CK-D15F

Auxiliary feedback

User-supplied flying-lead cable.

Low-profile connector kit

Low-profile connector kit

2090-K6CK-D15MF

1326-CCUT-L-xxx flying-lead feedback cable.

Low-profile feedback module

2090-K6CK-KENDAT

Panel-mounted breakout board kit

2090-UXBK-D15xx (1)

Motor feedback

Refer to Table 84…Table 86 for the flying-lead cable available for your motor.

Motor feedback

Refer to Table 84…Table 86 for the flying-lead cable available for your motor.

(1) Not compatible with 1326-CCUT-L-xxx cable.

The procedure for wiring your motor feedback varies slightly, depending on the motor family. The cables compatible with your motor or actuator depend on the connectors installed on the motor or actuator. Refer to MP-Series Motor and Actuator Connectors on page 107 for more information on circular DIN and bayonet connectors. Table 84 - Motor Feedback Cable Compatibility - Bayonet Connectors Motor/Actuator

Connector Type

Feedback Type

MPL-A/Bxxxx-S/Mx2xAA

High-resolution encoder

MPL-A3xxx-Hx2xAA MPL-A4xxx-Hx2xAA MPL-A45xxx-Hx2xAA

Incremental encoder

MPL-B3xxx-Rx2xAA MPL-B4xxx-Rx2xAA MPL-B45xxx-Rx2xAA

Bayonet

Motor resolver

Feedback Cable Premolded

Flying-lead

2090-UXNFBMP-Sxx

2090-XXxFMP-Sxx (1)

N/A

2090-CDNFDMP-Sxx

1326AB-Bxxxx-M2L/S2L

High-resolution encoder 2090-UXNFBMP-Sxx

2090-XXxFMP-Sxx (1)

1326AB-Bxxxx-21

Motor resolver

N/A

1326-CCUT-L-xxx

F-Series

Incremental encoder

2090-UXNFBHF-Sxx

2090-XXNFHF-Sxx

(1) For Bulletin MPL and 1326AB (M2L/S2L) motors equipped with bayonet connectors. These cables are available as standard (catalog number 2090-XXNFMP-Sxx) and continuous-flex (catalog number 2090-XXTFMP-Sxx).

Refer to Flying-lead Feedback Cable Pinouts beginning on page 119 for the motor-to-drive feedback cable pinout used in your application. Refer to MP-Series Motor and Actuator Connectors on page 107 for more information on circular DIN and bayonet connectors.

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

117

Page 118

Chapter 5

Connect the Kinetix 6000 Drive System

Table 85 - Motor Feedback Cable Compatibility - Threaded DIN/Plastic Connectors Motor/Actuator

Connector Type

MPL-A/B15xxx-V/Ex4xAA MPL-A/B2xxx-V/Ex4xAA MPL-A/B15xxx-Hx4xAA MPL-A/B2xxx-Hx4xAA MPS-A/Bxxxx-S/M

Feedback Type

Feedback Cable (1) Premolded

Flying-lead

N/A

2090-XXNFMF-Sxx (standard) or 2090-CFBM4DF-CDAFxx (continuous-flex)

2090-CFBM6DD-CCAAxx

2090-CFBM6DF-CBAAxx

High-resolution encoder

Circular (threaded) DIN

MPAS-A/Bxxxxx-V/A

Incremental encoder

High-resolution encoder

MPAR-A/B1xxxx-V and MPAR-A/B2xxxx-V (series A) TLY-Axxxx-H

Circular Plastic

Incremental encoder

(1) You must remove the motor-side o-ring when using 2090-CFBM7xx-xxAxxx cables.

Table 86 - Motor Feedback Cable Compatibility - SpeedTec DIN Connectors Motor/Actuator

Connector Type

Feedback Type

Premolded

Flying-lead

2090-CFBM7DD-CEAAxx (standard) or 2090-CFBM7DD-CEAFxx (continuous-flex)

2090-CFBM7DF-CEAAxx (standard) or 2090-CFBM7DF-CEAFxx (continuous-flex)

Incremental encoder

N/A

2090-XXNFMF-Sxx (standard) or 2090-CFBM7DF-CDAFxx (continuous-flex)

Motor resolver

N/A

2090-CFBM7DF-CEAAxx (standard) or 2090-CFBM7DF-CEAFxx (continuous-flex)

2090-CFBM7DD-CEAAxx (standard) or 2090-CFBM7DD-CEAFxx (continuous-flex)

2090-CFBM7DF-CEAAxx (standard) or 2090-CFBM7DF-CEAFxx (continuous-flex)

N/A

2090-XXNFMF-Sxx (standard) or 2090-CFBM7DF-CDAFxx (continuous-flex)

MPL-A/B15xxx-V/Ex7xAA MPL-A/B2xxx-V/Ex7xAA

High-resolution encoder

MPL-A/B15xxx-Hx7xAA MPL-A/B2xxx-Hx7xAA

Incremental encoder

MPL-A/B3xxx-S/Mx7xAA, MPL-A/B4xxx-S/Mx7xAA, MPL-A/B45xxx-S/Mx7xAA, MPL-A/B5xxx-S/Mx7xAA, MPL-B6xxx-S/Mx7xAA, MPL-B8xxx-S/Mx7xAA MPL-B9xxx-S/Mx7xAA

Circular (SpeedTec) DIN

MPL-A/B3xxx-Hx7xAA (1) MPL-A/B4xxx-Hx7xAA (1) MPL-A/B45xxx-Hx7xAA (1) LDAT-Sxxxxxx-xBx (1) MPL-B3xxx-Rx7xAA MPL-B4xxx-Rx7xAA MPL-B45xxx-Rx7xAA

Circular (SpeedTec) DIN

Feedback Cable (2)

High-resolution encoder

MPM-A/Bxxxxx-2 MPF-A/Bxxxx-S/M MPS-A/Bxxxx-S/M MPM-A/Bxxxxx-S/M MPAS-A/Bxxxxx-V MPAR-A/B1xxxx-V and MPAR-A/B2xxxx-V (series B) MPAR-A/B3xxxx-M MPAI-A/BxxxxxM3

High-resolution encoder Circular (SpeedTec) DIN

RDB-Bxxxx-7/3 MPAS-A/Bxxxxx-A

Incremental encoder

LDC-Cxxxx or LDL-xxxxx (1)

Sin/Cos encoder or TTL encoder

(1) These motors/linear thrusters are equipped with SpeedTec DIN connectors, however, the feedback option requires the additional conductors supplied with the cables listed. (2) You must remove the motor-side o-ring when using 2090-CFBM7xx-xxAxxx cables.

118

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017