The text of a manual · part 14 of 33
Kinetix 6000 Multi-axis Servo Drives User Manual: Ch5 - Connect the Kinetix 6000 Drive System, pages 110 to 118
Pages 110 to 118 of 290, from Kinetix 6000 Multi-axis Servo Drives User Manual
The original document is the PDF (21 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 2094-BM01 and Allen-Bradley 2094-PRF
Page 110
Chapter 5
Connect the Kinetix 6000 Drive System
These cables contain three-phase power wires and brake wires. The brake wires have a shield braid (shown below as gray) that folds back under the cable clamp before the conductors are attached to the motor brake (BC) connector. Thermal switch wires are included in the feedback cable. Refer to Axis Module/Rotary Motor Wiring Examples beginning on page 198 for interconnect diagrams. Figure 58 - Motor Power Terminations (cables with brake wires)
Motor Cable Shield Clamp
MP-Series Cable Brake Wires
Kinetix 6000 IAM/AM Module (IAM module is shown)
DCDC+
W V U
L3 L2 L1
1 2 3 4
CTRL 2 CTRL 1
CONT ENCONT EN+
RX
DPI
1 2 3 4 5 6
MBRK MBRK + COM PWR DBRK DBRK +
Motor Power (MP) Connector
TX
Resistive/Motor Brake (BC) Connector
BAUD RATE
The cable shield clamp shown above is mounted to an IAM module. Cables attach to the clamp on each AM module in the same way.
110
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
Page 111
Connect the Kinetix 6000 Drive System
Chapter 5
The 1326AB (resolver) power cables (catalog number 1326-CPx1T-L-xxx) contain the three-phase wires, brake wires, and thermal switch wires. To improve the EMC performance of your system, route the wires as shown. Refer to Axis Module/Rotary Motor Wiring Examples beginning on page 198 for interconnect diagrams. Figure 59 - Motor Power Terminations (1326-CPx1T-L-xxx cable) MF-16 MF-17
Thermal Switch Wires
MF-S Terminal Block (mounted on DIN rail) Refer to page 35 for treatment of painted panels.
Motor Cable Shield Clamp
Thermal Switch Wires
Kinetix 6000 IAM/AM Module (IAM module is shown)
DCDC+
W V U
L3 L2 L1
MBRK MBRK + COM PWR DBRK DBRK +
CONT ENCONT EN+
Keep wires separated as much as possible.
1 2 3 4
CTRL 1 CTRL 2
RX
DPI
Motor Power (MP) Connector 1 2 3 4 5 6
Low-profile motor feedback connector (2090-K6CK-D15MF) pins 16, 17, and S provide filtering for 1326-CPx1T-L-xxx cables (refer to page 126 for an illustration).
TX
Resistive/Motor Brake (BC) Connector BAUD RATE
The cable shield clamp shown above is mounted to an IAM module. Cables attach to the clamp on each AM module in the same way. IMPORTANT
We recommend securing the cable shield in the clamp with a tie wrap to improve stress relief.
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
111
Page 112
Chapter 5
Connect the Kinetix 6000 Drive System
Cable shield and lead preparation is provided with most Allen-Bradley® cable assemblies. Follow these guidelines if your motor power cable shield and wires require preparation. Figure 60 - Cable Shield and Lead Preparation Strip Length (see table below)
U Outer Insulation
V W
Motor Power Cable Exposed Braid 25.4 mm (1.0 in.)
105 mm (4.1 in.) 130 mm (5.1 in.)
Refer to Axis Module/Rotary Motor Wiring Examples beginning on page 198 for interconnect diagrams. Table 74 - Motor Power (MP) Connector Servo Motor
MP Connector (IAM/AM module)
1326AB (resolver)
All Other Motors
MP Pin
Signal
1 / Black
U / Brown
1
U
2 / Black
V / Black
2
V
3 / Black
W / Blue
3
W
Green/Yellow
Green/Yellow
4
Table 75 - Termination Specifications IAM/AM Module Cat. No. 2094-AC05-Mxx-x, 2094-AMP5-x, 2094-AM01-x, 2094-AC09-M02-x, 2094-AM02-x, 2094-BC01-Mxx-x, 2094-BMP5-x, 2094-BM01-x 2094-BC02-M02-x, 2094-BM02-x
112
Recommended Wire Size mm2 (AWG)
Strip Length mm (in.)
Motor power cable depends on motor/ drive combination. 10 (0.38)
Torque Value N•m (lb•in)
0.5…0.6 (4.4…5.3)
6 (10) max
2094-AC16-M03-x, 2094-AM03-x 2094-AC32-M05-x, 2094-AM05-x
10 (8) max
10 (0.38)
1.2…1.5 (10.6…13.2)
2094-BC04-M03-x, 2094-BM03-x
10 (8) max
10 (0.38)
1.2…1.5 (10.6…13.2)
2094-BC07-M05-x, 2094-BM05-x
30 (3) max
16 (0.63)
2.4…3.0 (21.6…26.5)
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
Page 113
Connect the Kinetix 6000 Drive System
Chapter 5
Wire the Motor/Resistive Brake (BC) Connector This example applies to AM modules and the inverter section of IAM modules. Figure 61 - IAM/AM Module (BC connector)
KMBR K+ B MR COM R PW KDBR K+ DBR
1
2
3
4
5
6
Kinetix 6000 IAM/AM Module (IAM module is shown)
Motor/Resistive Brake (BC) Connector
24V DC Brake Input Power Connections IMPORTANT
If your system includes a LIM module, you can source the 24V DC from the LIM module (P1L or PSL connector).
Table 76 - Motor/Resistive Brake (BC) Connector 2094-ALxxS, 2094-BLxxS, or 2094-XL75S-Cx LIM Module
2094-AL09 and 2094-BL02 LIM Module
BC Connector (IAM/AM modules)
P1L Pin
Signal
PSL Pin
Signal
BC Pin
Signal
1
IO_PWR2
1
MBRK PWR
3
PWR
2
IO_COM2
2
MBRK COM
4
COM
RBM Module Connections Table 77 - Motor/Resistive Brake (BC) Connector RBM Module I/O Connections
BC Connector (IAM/AM modules)
TB3 Pin
Signal
MP Pin
Signal (1)
6
COIL_A1
1
DBRK+
7
COIL_A2
2
DBRK-
(1) Firmware revision 1.071 or later is required to use the DBRK outputs on the Kinetix 6000 IAM/AM module.
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
113
Page 114
Chapter 5
Connect the Kinetix 6000 Drive System
Motor Brake Connections The procedure for wiring your motor brake varies slightly, depending on the motor family. The cables compatible with your motor or actuator depend on the connectors installed on the motor or actuator. Refer to MP-Series Motor and Actuator Connectors on page 107 for more information on circular DIN and bayonet connectors. Table 78 - Motor Brake Cable Compatibility - Bayonet Connectors Motor Series MPL-A/B3xxx-xx2xAA, MPL-A/B4xxx-xx2xAA, MPL-A/B45xxx-xx2xAA, MPL-A/B5xxx-xx2xAA, MPL-B6xxx-xx2xAA, MPL-B8xxx-xx2xAA, MPL-B9xxx-xx2xAA
Connector Type
Brake Wires
Cable Cat. No.
Bayonet
The motor has a brake connector. Brake wires are in the brake cable.
2090-UXxBMP-18Sxx brake cable (1)
P-LOK
The motor has a brake connector. Brake wires are in the brake cable.
1326AB (M2L/S2L) F-Series 1326AB (resolver)
Straight brake connector kit 9101-0330 1326-CPx1T-L-xxx power cable
(1) For Bulletin MPL and 1326AB motors equipped with bayonet connectors. These cables are available as standard (catalog number 2090-UXNBMP-18Sxx) and continuous-flex (catalog number 2090-UXTBMP-18Sxx).
Table 79 - Motor Brake Cable Compatibility - Threaded DIN and Circular Plastic Connectors Connector Type
Brake Wires
Cable Cat. No.
MPS-A/Bxxx, MPAS-A/Bxxx, MPMA-A/Bxxx, MPAR-A/B1xxx, MPAR-A/B2xxx (series A)
Circular (threaded) DIN
The motor/actuator does not have a brake connector. Brake wires are included in the power cable.
2090-XXNPMF-xxSxx (standard) or 2090-CPBM4DF-xxAFxx (continuous-flex)
TLY-Axxxx-H
Circular Plastic
The motor/actuator does not have a brake connector. Brake wires are included in the power cable.
2090-CPBM6DF-16AAxx power cable
Motor Series MPL-A/B15xxx-xx4xAA, MPL-A/B2xxx-xx4xAA
Table 80 - Motor Brake Cable Compatibility - SpeedTec DIN Connectors Connector Type
Motor Series
Brake Wires
Cable Cat. No. (1)
MPL-A/B15xxx-xx7xAA, MPL-A/B2xxx-xx7xAA MPL-A/B3xxx-xx7xAA, MPL-A/B4xxx-xx7xAA, MPL-A/B45xxx-xx7xAA, MPL-A/B5xxx-xx7xAA, MPL-B6xxx-xx7xAA, MPL-B8xxx-xx7xAA MPL-B9xxx-xx7xAA
The motor/actuator does not Circular have a brake connector. (SpeedTec) DIN Brake wires are included in the power cable.
MPM-A/Bxxx, MPF-A/Bxxx, MPS-A/Bxxx
2090-CPBM7DF-xxAAxx (standard) or 2090-CPBM7DF-xxAFxx (continuous-flex)
MPAS-A/Bxxx, MPAR-A/B1xxx, MPAR-A/B2xxx (series B), MPAR-A/B3xxx, MPAI-A/Bxxx (1) You must remove the motor-side o-ring when using 2090-CFBM7xx-xxAxxx cables.
IMPORTANT
114
Use surge suppression when controlling a brake coil. Refer to Controlling a Brake Example on page 213.
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
Page 115
Connect the Kinetix 6000 Drive System
Chapter 5
Figure 62 - Brake Cable Preparation Outer Insulation Strip Length 10 mm (0.375 in.) Brake Cable 105 mm (4.1 in.)
Table 81 - Motor/Resistive Brake (BC) Connector BC Connector (IAM/AM module)
Motor Brake Wires 2090-UXxBMP-18Sxx Brake Cable
2090-XXNPMF-xxSxx 2090-CPBMxDF-xxAFxx Power Cable
2090-CPBM6DF-16AAxx Power Cable
1326-CPx1T-L-xxx Power Cable
BC Pin
Signal
A / BR+
F/+ / BR+/MBRK+
7 / MBRK+
6 / B1
5
MBRK+
C / BR-
G/- / BR-/MBRK-
9 / MBRK-
4 / B2
6
MBRK-
Recommended Wire Size mm2 (AWG)
Strip Length mm (in.)
Torque Value N•m (lb•in)
0.75 (18)
10 (0.38)
0.22…0.25 (1.9…2.2)
Table 82 - Termination Specifications BC Connector (IAM/AM module) BC Pin
Signal
BC-6 BC-5 BC-4 BC-3 BC-2 BC-1
MBRKMBRK+ COM PWR DBRKDBRK+
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
115
Page 116
Chapter 5
Connect the Kinetix 6000 Drive System
Apply the Motor Cable Shield Clamp
This procedure assumes you have completed wiring your motor power (MP) connector and are ready to apply the cable shield clamp. TIP
Your drive can be equipped with either the pivot-open or slide-open cable clamp.
Follow these steps to apply the motor cable shield clamp. 1. Depress the spring loaded clamp. Screwdriver Tip 3.5 mm (0.14 in.)
The pivot-open cable clamp was designed to replace the slide-open cable clamp. Pivot-open clamp features include: • Screwdriver not required for depressing the spring • Tie wrap not required or recommended
Pry clamp back with thumb.
Screwdriver Tip in Slot Pivot-open Cable Clamp
Slide-open Cable Clamp
2. Position the exposed portion of the cable braid directly in line with the clamp. 3. Release the spring, making sure the cable and cable braid are held secure by the clamp. 4. Attach tie wrap (slide-open clamp only) around cable and clamp for additional strain relief.
Exposed Braid (under clamp)
Motor Cable
Outer Insulation Horizontal Cable Clamp Orientation Examples Cable Clamp Outer Insulation
Tie Wrap
Slide-open Cable Clamp Exposed Braid (under clamp)
Vertical Cable Clamp Orientation Example Motor Cable
Vent holes on top of IAM/AM module. Outer Insulation
Exposed Braid (under clamp)
Motor Cable Pivot-open Cable Clamp
Vent holes on top of IAM/AM module.
5. Repeat step 1 through step 4 for each IAM, AM, or IPIM module.
116
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
Page 117
Connect the Kinetix 6000 Drive System
Chapter 5
Factory made cables with premolded connectors are designed to minimize EMI and are recommended over hand-built cables to improve system performance. However, other options are available for building your own feedback and I/O cables.
Feedback and I/O Cable Connections
Table 83 - Options for Connecting Motor Feedback and I/O Connection Option
Connector Kit Cat. No.
Cable
Using this Type of Cable
Premolded connector
N/A
Motor feedback
2090-K6CK-D15M
Motor feedback
Refer to Table 84 and Table 85 for the flying-lead cable available for your motor.
2090-K6CK-D26M
I/O interface
User-supplied flying-lead cable.
2090-K6CK-D15F
Auxiliary feedback
User-supplied flying-lead cable.
Low-profile connector kit
Low-profile connector kit
2090-K6CK-D15MF
1326-CCUT-L-xxx flying-lead feedback cable.
Low-profile feedback module
2090-K6CK-KENDAT
Panel-mounted breakout board kit
2090-UXBK-D15xx (1)
Motor feedback
Refer to Table 84…Table 86 for the flying-lead cable available for your motor.
Motor feedback
Refer to Table 84…Table 86 for the flying-lead cable available for your motor.
(1) Not compatible with 1326-CCUT-L-xxx cable.
The procedure for wiring your motor feedback varies slightly, depending on the motor family. The cables compatible with your motor or actuator depend on the connectors installed on the motor or actuator. Refer to MP-Series Motor and Actuator Connectors on page 107 for more information on circular DIN and bayonet connectors. Table 84 - Motor Feedback Cable Compatibility - Bayonet Connectors Motor/Actuator
Connector Type
Feedback Type
MPL-A/Bxxxx-S/Mx2xAA
High-resolution encoder
MPL-A3xxx-Hx2xAA MPL-A4xxx-Hx2xAA MPL-A45xxx-Hx2xAA
Incremental encoder
MPL-B3xxx-Rx2xAA MPL-B4xxx-Rx2xAA MPL-B45xxx-Rx2xAA
Bayonet
Motor resolver
Feedback Cable Premolded
Flying-lead
2090-UXNFBMP-Sxx
2090-XXxFMP-Sxx (1)
N/A
2090-CDNFDMP-Sxx
1326AB-Bxxxx-M2L/S2L
High-resolution encoder 2090-UXNFBMP-Sxx
2090-XXxFMP-Sxx (1)
1326AB-Bxxxx-21
Motor resolver
N/A
1326-CCUT-L-xxx
F-Series
Incremental encoder
2090-UXNFBHF-Sxx
2090-XXNFHF-Sxx
(1) For Bulletin MPL and 1326AB (M2L/S2L) motors equipped with bayonet connectors. These cables are available as standard (catalog number 2090-XXNFMP-Sxx) and continuous-flex (catalog number 2090-XXTFMP-Sxx).
Refer to Flying-lead Feedback Cable Pinouts beginning on page 119 for the motor-to-drive feedback cable pinout used in your application. Refer to MP-Series Motor and Actuator Connectors on page 107 for more information on circular DIN and bayonet connectors.
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
117
Page 118
Chapter 5
Connect the Kinetix 6000 Drive System
Table 85 - Motor Feedback Cable Compatibility - Threaded DIN/Plastic Connectors Motor/Actuator
Connector Type
MPL-A/B15xxx-V/Ex4xAA MPL-A/B2xxx-V/Ex4xAA MPL-A/B15xxx-Hx4xAA MPL-A/B2xxx-Hx4xAA MPS-A/Bxxxx-S/M
Feedback Type
Feedback Cable (1) Premolded
Flying-lead
N/A
2090-XXNFMF-Sxx (standard) or 2090-CFBM4DF-CDAFxx (continuous-flex)
2090-CFBM6DD-CCAAxx
2090-CFBM6DF-CBAAxx
High-resolution encoder
Circular (threaded) DIN
MPAS-A/Bxxxxx-V/A
Incremental encoder
High-resolution encoder
MPAR-A/B1xxxx-V and MPAR-A/B2xxxx-V (series A) TLY-Axxxx-H
Circular Plastic
Incremental encoder
(1) You must remove the motor-side o-ring when using 2090-CFBM7xx-xxAxxx cables.
Table 86 - Motor Feedback Cable Compatibility - SpeedTec DIN Connectors Motor/Actuator
Connector Type
Feedback Type
Premolded
Flying-lead
2090-CFBM7DD-CEAAxx (standard) or 2090-CFBM7DD-CEAFxx (continuous-flex)
2090-CFBM7DF-CEAAxx (standard) or 2090-CFBM7DF-CEAFxx (continuous-flex)
Incremental encoder
N/A
2090-XXNFMF-Sxx (standard) or 2090-CFBM7DF-CDAFxx (continuous-flex)
Motor resolver
N/A
2090-CFBM7DF-CEAAxx (standard) or 2090-CFBM7DF-CEAFxx (continuous-flex)
2090-CFBM7DD-CEAAxx (standard) or 2090-CFBM7DD-CEAFxx (continuous-flex)
2090-CFBM7DF-CEAAxx (standard) or 2090-CFBM7DF-CEAFxx (continuous-flex)
N/A
2090-XXNFMF-Sxx (standard) or 2090-CFBM7DF-CDAFxx (continuous-flex)
MPL-A/B15xxx-V/Ex7xAA MPL-A/B2xxx-V/Ex7xAA
High-resolution encoder
MPL-A/B15xxx-Hx7xAA MPL-A/B2xxx-Hx7xAA
Incremental encoder
MPL-A/B3xxx-S/Mx7xAA, MPL-A/B4xxx-S/Mx7xAA, MPL-A/B45xxx-S/Mx7xAA, MPL-A/B5xxx-S/Mx7xAA, MPL-B6xxx-S/Mx7xAA, MPL-B8xxx-S/Mx7xAA MPL-B9xxx-S/Mx7xAA
Circular (SpeedTec) DIN
MPL-A/B3xxx-Hx7xAA (1) MPL-A/B4xxx-Hx7xAA (1) MPL-A/B45xxx-Hx7xAA (1) LDAT-Sxxxxxx-xBx (1) MPL-B3xxx-Rx7xAA MPL-B4xxx-Rx7xAA MPL-B45xxx-Rx7xAA
Circular (SpeedTec) DIN
Feedback Cable (2)
High-resolution encoder
MPM-A/Bxxxxx-2 MPF-A/Bxxxx-S/M MPS-A/Bxxxx-S/M MPM-A/Bxxxxx-S/M MPAS-A/Bxxxxx-V MPAR-A/B1xxxx-V and MPAR-A/B2xxxx-V (series B) MPAR-A/B3xxxx-M MPAI-A/BxxxxxM3
High-resolution encoder Circular (SpeedTec) DIN
RDB-Bxxxx-7/3 MPAS-A/Bxxxxx-A
Incremental encoder
LDC-Cxxxx or LDL-xxxxx (1)
Sin/Cos encoder or TTL encoder
(1) These motors/linear thrusters are equipped with SpeedTec DIN connectors, however, the feedback option requires the additional conductors supplied with the cables listed. (2) You must remove the motor-side o-ring when using 2090-CFBM7xx-xxAxxx cables.
118
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017