The text of a manual · part 15 of 33
Kinetix 6000 Multi-axis Servo Drives User Manual: Ch5 - Connect the Kinetix 6000 Drive System, pages 119 to 127
Pages 119 to 127 of 290, from Kinetix 6000 Multi-axis Servo Drives User Manual
The original document is the PDF (21 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 2094-BM01 and Allen-Bradley 2094-PRF
Page 119
Connect the Kinetix 6000 Drive System
Chapter 5
Flying-lead Feedback Cable Pinouts Refer to the following tables for the motor-to-drive feedback cable pinout used in your application. Table 87 - 2090-XXxFMP-Sxx Feedback Cable (1) Bayonet Connector Pin
High-resolution Feedback
Rotary Motors
MPL-B3xxx…MPL-B9xxx-M/Sx2xAA MPL-A5xxx-M/Sx2xAA 1326AB-Bxxx-M2L/S2L
MPL-A3xxx-M/Sx2xAA MPL-A4xxx-M/Sx2xAA MPL-A45xxx-M/Sx2xAA
MPL-A3xxx-Hx2xAA MPL-A4xxx-Hx2xAA MPL-A45xxx-Hx2xAA
A
Sin+
Sin+
AM+
1
B
Sin-
Sin-
AM-
2
C
Cos+
Cos+
BM+
3
D
Cos-
Cos-
BM-
4
E
Data+
Data+
IM+
5
F
Data-
Data-
IM-
10
K
Reserved
EPWR_5V
EPWR_5V
14
L
Reserved
ECOM
ECOM
6
N
EPWR_9V
Reserved
Reserved
7
P
ECOM
Reserved
Reserved
6
R
TS+
TS+
TS+
11
S
TS-
TS-
TS-
–
T
Reserved
Reserved
S1
12
U
Reserved
Reserved
S2
13
V
Reserved
Reserved
S3
8
Incremental Feedback Drive MF Connector Pin
(1) These cables are available as standard (catalog number 2090-XXNFMP-Sxx) and continuous-flex (catalog number 2090-XXTFMP-Sxx).
Table 88 - 2090-CFBM7DF-CEAAxx Feedback Cable
Table 89 - 2090-CDNFDMP-Sxx Feedback Cable
Motor DIN Connector Pin
Resolver Feedback MPL-Bxxxx-Rx7xAA MPM-xxxxxx-2
Drive MF Connector Pin
Motor Bayonet Connector Pin
Resolver Feedback MPL-Bxxxx-Rx2xAA
Drive MF Connector Pin
1
S2
1
A
S2
1
2
S4
2
B
S4
2
3
S1
3
C
S1
3
4
S3
4
D
S3
4
5
R1
5
G
R1
5
6
R2
10
H
R2
10
11
EPWR_9V
7
N
EPWR_9V
7
12
ECOM
6
P
ECOM
6
13
TS+
11
R
TS+
11
14
TS-
6
S
TS-
6
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
119
Page 120
Chapter 5
Connect the Kinetix 6000 Drive System
Table 90 - 2090-XXNFMF-Sxx or 2090-CFBMxDF-xxAxxx Feedback Cables Circular DIN Connector Pin
High-resolution Feedback MPL-B15xxx…MPL-B2xxx-V/Ex4/7xAA MPF/MPS-Bxxx-M/S MPF-A5xxx-M/S
Rotary Motors
MPL-B3xxx…MPL-B9xxx-M/Sx7xAA MPL-A5xxx-M/Sx7xAA MPM-A165xxx…MPM-A215xxx MPM-Bxxxxx-M/S
Incremental Feedback
MPL-A15xxx…MPL-A2xxx-V/Ex4/7xAA MPF/MPS-A3xx-M/S MPF/MPS-A4xx-M/S MPF/MPS-A45xx-M/S MPS-A5xxx-M/S RDB-Bxxxxx-3/7 MPL-A3xxx-M/Sx7xAA MPL-A4xxx-M/Sx7xAA MPL-A45xxx-M/Sx7xAA MPM-A115xxx…MPM-A130xxx-M/S
MPL-A15xxx-Hx4/7xAA MPL-A2xxx-Hx4/7xAA MPL-B15xxx-Hx4/7xAA MPL-B2xxx-Hx4/7xAA MPL-A3xxx-Hx7xAA MPL-A4xxx-Hx7xAA MPL-A45xxx-Hx7xAA
Drive MF Connector Pin
Linear Motors
N/A
LDC-Cxxxx and LDL-xxxx
LDC-Cxxxx and LDL-xxxx
Linear Actuators
MPAS-Bxxxxx-VxxSxA MPAR-Bxxxx, MPAI-Bxxxx
MPAS-Axxxxx-VxxSxA MPAR-Axxxx, MPAI-Axxxx
MPAS-A/Bxxxxx-ALMx2C LDAT-Sxxxxxx-xBx
1
Sin+
Sin+
AM+
1
2
Sin-
Sin-
AM-
2
3
Cos+
Cos+
BM+
3
4
Cos-
Cos-
BM-
4
5
Data+
Data+
IM+
5
6
Data-
Data-
IM-
10
Reserved
CLK+ (1)
Reserved
9
8
Reserved
CLK- (1)
Reserved
15
9
Reserved
EPWR_5V
EPWR_5V
14
10
Reserved
ECOM
ECOM
6
11
EPWR_9V
Reserved
Reserved
7
12
ECOM
Reserved
Reserved
6
13
TS+
TS+
TS+
11
14
TS-
TS-
TS-
–
15
Reserved
Reserved
S1
12
16
Reserved
Reserved
S2
13
17
Reserved
Reserved
S3
8
7
(1) Applies to RDB-Bxxxxx-3/7 direct-drive motors only.
Table 91 - 2090-CFBM6DF-CBAAxx Feedback Cable
120
Rotary Motor Incremental Feedback Connector Pin TLY-Axxxx-H
Drive MF Connector Pin
Rotary Motor Incremental Feedback Connector Pin TLY-Axxxx-H
Drive MF Connector Pin
9
AM+
1
15
S1
12
10
AM-
2
17
S2
13
11
BM+
3
19
S3
8
12
BM-
4
22
EPWR_5V
14
13
IM+
5
23
ECOM
6
14
IM-
10
24
Shield
Connector housing
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
Page 121
Connect the Kinetix 6000 Drive System
Chapter 5
Table 92 - 2090-XXNFHF-Sxx Feedback Cable Rotary Motor Connector Pin
Incremental Feedback F-Series Motors
Drive MF Connector Pin
A
AM+
1
B
AM-
2
C
BM+
3
D
BM-
4
E
IM+
5
F
IM-
10
G
Reserved
–
H
Reserved
–
J
EPWR_5VM
14
K
EPWR_5VM
14
L
ECOMM
6
M
ECOMM
6
N
S2
13
P
S3
8
R
TS+
11
S
TS-
6
T
S1
12
Table 93 - 1326-CCUT-L-xxx Feedback Cable
Table 94 - 1326-CPx1T-L-xxx Power Cable
Rotary Motor Connector Pin
Resolver Feedback 1326AB-Bxxxx-21
Drive MF Connector Pin (1)
Rotary Motor Connector Pin
Thermal Switch Connections 1326AB-Bxxxx-21
Drive MF Connector Pin (2)
A
R1
5
5
TS+
16
B
R2
10
9
TS-
17
C
–
–
–
Shield
S
D
S1
3
E
S3
4
F
–
–
G
S2
1
H
S4
2
(1) For termination of individual drain wires, use Low Profile connector kit (catalog number 2090-K6CK-D15MF) and reference figure on page 126. (2) Thermal switch wires (5 and 9) are in the motor power cable (catalog number1326-CPx1T-L-xxx). Use Low Profile connector kit (catalog number 2090-K6CK-D15MF) and reference figure on page 126.
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
121
Page 122
Chapter 5
Connect the Kinetix 6000 Drive System
Wiring the Feedback and I/O Connectors
These procedures assume you have mounted your Kinetix 6000 system, completed all power wiring, and are ready to connect your feedback and I/O cables. For This Connection
Go to
Premolded cable
Connect Premolded Motor Feedback Cables on page 122.
Panel-mounted breakout board
Connect Panel-mounted Breakout Board Kits on page 123.
Low-profile connector
Wire Low-profile Connector Kits on page 124.
Connect Premolded Motor Feedback Cables Motor feedback cables with premolded connectors plug directly into 15-pin motor feedback (MF) connectors on either the IAM or AM modules (no wiring is necessary). IMPORTANT
When using Bulletin 2090 cables with premolded connectors, tighten the mounting screws (finger tight) to improve system performance.
Figure 63 - IAM/AM Module (MF connector)
Kinetix 6000, Side View (IAM module is shown)
Kinetix 6000, Front View (IAM module is shown)
2090-CFBM7DD-CDAAxx Cable (premolded connector)
Motor Feedback (MF) Connector
122
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
Page 123
Connect the Kinetix 6000 Drive System
Chapter 5
Connect Panel-mounted Breakout Board Kits The 2090-UXBK-D15xx panel-mounted breakout board kit includes a DINrail breakout board and cable. The cable connects between the breakout board and the motor feedback (MF) connector. Wires from your flying-lead motor feedback cable connect to the terminals. Figure 64 - IAM/AM Module (MF connector)
Kinetix 6000, Side View (IAM module is shown)
Kinetix 6000, Front View (IAM module is shown)
2090-UXBC-D15xx Breakout Cable Motor Feedback (MF) Connector
Refer to CN2 Motor Feedback Breakout Board Installation Instructions, publication 2090-IN006, for connector breakout board specifications.
IMPORTANT
2090-UXBB-D15 Panel-mounted Breakout Board Wire Terminations
The panel-mounted breakout board kit (2090-UXBK-D15xx) is not compatible with 1326-CCUT-L-xxx cable.
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
123
Page 124
Chapter 5
Connect the Kinetix 6000 Drive System
Wire Low-profile Connector Kits The 2090-K6CK-xxxx low-profile connector kits are suitable for terminating flying-lead motor feedback, auxiliary feedback, and I/O connections. They also apply to I/O connections on the 2094-AL09 and 2094-BL02 LIM modules. Table 95 - Low-profile Connector Kits Connector Kit Cat. No.
Description
Cable Compatibility
2090-K6CK-KENDAT
Low-profile feedback module for EnDat to Hiperface conversion (15-pin, male, D-sub). Use with any Kinetix 6000 IAM/AM module and Bulletin RDB direct-drive motor with EnDat high-resolution feedback.
2090-XXNFMF-Sxx, 2090-CFBM7DF-CDAFxx
2090-K6CK-D15M
Low-profile connector kit for motor feedback (15-pin, male, D-sub). Use with any Kinetix 6000 IAM/AM module and compatible motors with incremental or high-resolution feedback.
2090-XXxFMP-Sxx, 2090-XXNFMF-Sxx, 2090-XXNFHF-Sxx, 2090-CFBMxDF-CxAxxx
2090-K6CK-D15M
Low-profile connector kit for motor feedback (15-pin, male, D-sub). Use with Kinetix 6000 IAM/AM module and MPL-Bxxxx-R (resolver feedback) motors.
2090-CDNFDMP-Sxx 2090-CFBM7DF-CEAAxx 2090-CFBM7DF-CEAFxx
2090-K6CK-D15MF
Low-profile connector kit for motor feedback (15-pin, male, D-sub) with filter. Use with Kinetix 6000 IAM/AM module and 1326ABxxxx-21 (resolver feedback) motors.
1326-CCUT-L-xxx
2090-K6CK-D15F
Low-profile connector kit for auxiliary feedback (15-pin, female, D-sub). Use with any Kinetix 6000 IAM/AM module for auxiliary feedback applications.
Customer Supplied
2090-K6CK-D26M
Low-profile connector kit for I/O (26-pin, male, D-sub). Use with any Kinetix 6000 IAM/AM module or 2094-AL09 and 2094-BL02 LIM module for making I/O connections.
Customer supplied
Figure 65 - IAM/AM Module (IOD/MF/AF connectors)
Kinetix 6000, Side View (IAM module is shown)
Kinetix 6000, Front View (IAM module is shown)
2090-Kxxx-Dxxx Low-profile Connector Kit with flying-lead Feedback or I/O Cable
I/O (IOD) Connector
Motor Feedback (MF) Connector
124
Auxiliary Feedback (AF) Connector
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
Page 125
Connect the Kinetix 6000 Drive System
Chapter 5
Figure 66 - Wiring (15-pin) Flying-lead Feedback Cable Connections 2090-K6CK-D15M and 2090-K6CK-D15F Connector Kit 15-pin (male) Motor Feedback Low-profile Connector
Bare Wires Wire Insulation Foil Shield
Pin 10 Pin 5
Outer Insulation
Bulletin 2090 Feedback Cable
2090-K6CK-D15x Low-profile Connector Kit Shield Clamp Exposed Braid Under Clamp
0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
Mounting Screws
Braided Shield
Turn clamp over to hold small wires secure.
15-pin (female) Auxiliary Feedback Low-profile Connector
Pin 15
Pin 1
Pin 1
Pin 11 Pin 6
Pin 5 Pin 10
Tie Wrap
Refer to Chapter 4 for feedback signal descriptions.
Pin 6 Pin 11 Pin 15
Refer to Appendix A for the motor feedback interconnect drawing for your application.
Refer to Low Profile Connector Kit Installation Instructions, publication 2094-IN007, for connector kit specifications. Bulletin 2090 Feedback Cable
Figure 67 - Wiring (15-pin) Flying-lead Feedback Cable Connections 2090-K6CK-KENDAT Feedback Module
Wire Insulation Foil Shield
Pin 10 Pin 5 Mounting Screws
Braided Shield
Pin 11 Pin 6
Bulletin 2090 Feedback Cable 2090-K6CK-KENDAT Low-profile Feedback Module
Shield Clamp Exposed Braid Under Clamp
Turn clamp over to hold small wires secure.
Pin 15
Pin 1
13 12 11 10 9 8 7 6 5 4 3 2 1
Outer Insulation
15-pin (male) Motor Feedback Low-profile Connector
Status Indicator
Bare Wires
Refer to Chapter 4 for feedback signal descriptions. Refer to Appendix A for the motor feedback interconnect drawing for your application. Refer to Low Profile EnDat Feedback Modules Installation Instructions, publication 2090-IN020, for connector kit specifications. Bulletin 2090 Feedback Cable
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
125
Page 126
Chapter 5
Connect the Kinetix 6000 Drive System
Figure 68 - Wiring (15-pin) Flying-lead Feedback Cable Connections 2090-K6CK-D15MF Connector Kit Bare Wires Drain Wire Wire Insulation Foil Shield
15-pin (male) Motor Feedback Low-profile Connector
Mounting Screws
Braided Shield
Pin 11 Pin 6
Pin 1
Drain wire (only with 1326-CCUT-L-xxx cable) folded back under clamp. 2090-K6CK-D15MF Low-profile Connector Kit Shield Clamp
Refer to Chapter 4 for feedback signal descriptions. Refer to Appendix A for the motor feedback interconnect diagram for your application.
Tie Wrap
Refer to Low Profile Connector Kit Installation Instructions, publication 2094-IN007, for connector kit specifications. 17 16 S
Exposed Braid under clamp
Turn clamp over to hold small wires secure.
Pin 15
1326-CCUT-L-xxx Cable 0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
Outer Insulation
Pin 10 Pin 5
Pins S, 16, and 17 are included on only 2090-K6CK-D15MF Low-profile connector kits and used for thermal switch connections to 1326AB (resolver) motors. After filtering, these pins connect to MF-11 and MF-6.
1326-CCUT-L-xxx Feedback Cable
IMPORTANT
Thermal Switch Wires
The purpose of the cable shield clamp is to provide a proper ground and improve system performance, not stress relief. Clamping the exposed braid under the shield clamp is critical. Turn clamp over, if necessary, to be sure of a proper ground.
Figure 69 - Wiring (26-pin) Flying-lead I/O Cable Connections 2090-K6CK-D26M Connector Kit Pin 18 Pin 9
Pin 26
Mounting Screws
Pin 19 Pin 10
12 11 10
9 8 7 6 5 4 3 2 1
2090-K6CK-D26M Low Profile Connector Kit)
S 26 25 24 S 23 22 21 20 19 18 17 16 15 14 13
Pin 1
26-pin (male) I/O Low Profile Connector
Refer to Low Profile Connector Kit Installation Instructions, publication 2094-IN007, for connector kit specifications. Tie Wrap Slot
Turn clamp over to hold small wires secure. Three Conductor I/O Cables
126
Discrete I/O Wire
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
Page 127
Connect the Kinetix 6000 Drive System
External Shunt Module Connections
Chapter 5
Follow these guidelines when wiring your external active or passive shunt module. IMPORTANT
When tightening screws to secure the wires, refer to the tables beginning on page 97 for torque values.
IMPORTANT
To improve system performance, run wires and cables in the wireways as established in Chapter 2.
Table 96 - Shunt Module Wiring Use This Shunt Module
Cat. No.
With This Drive Module
Do This
Power rail mounted shunt module.
2094-BSP2
N/A
• Verify the internal shunt jumper is in place between RC-2 and RC-3 (refer to Figure 70). • Verify the thermal switch jumper is in place between TS-1 and TS-2 (refer to Figure 70).
2094-BSP2 Shunt module
• Remove the internal shunt jumper between RC-2 and RC-3. • Remove the thermal switch jumper between TS-1 and TS-2 (if your shunt module includes a thermal switch). • Refer to External Shunt Modules on page 48 for noise zone considerations. • Refer to Shunt Module Wiring Examples on page 197. • Refer to the installation instructions provided with your Bulletin 1394 shunt module, publication 2090-IN004.
Cable Shield Clamp
External Shunt Resistor (RC) Connector
COL INT DC+
External Thermal Switch (TS) Connector
TS2 TS1
COL INT DC+
TS2 TS1
Jumpers (1)
1 2
Kinetix 6000 Shunt Module, Top View (catalog number 2094-BSP2)
1 2 3
Figure 70 - Shunt Module Jumper Settings
1 2 3
1394-SRxxxx
1 2
External passive shunt module connected to the power rail shunt module.
(1) These are the default jumper settings.
Rockwell Automation Publication 2094-UM001J-EN-P - March 2017
127