Page 281

Index Numerics 1756-MxxSE 142 1768-M04SE 142 1784-PM16SE 142 2090-K6CK-D15F 117, 124, 125 2090-K6CK-D15M 117, 124, 125, 198 2090-K6CK-D15MF 111, 117, 124, 126, 205 2090-K6CK-D26M 117, 124, 126 2090-K6CK-KENDAT 63, 78, 117, 124, 125 2094 power rail 52 26-pin I/O connector 163

A AC line filters noise reduction 47 selection 27 acceleration feedback 240 reference 237 acronyms 11 actual position feedback 237 actuators LDAT 209 MPAI 208 MPAR 208 MPAS 207 additional bus capacitance calculating 229 example 230 additional resources 12 analog outputs 69 analog test points DAC0 163 DAC1 163 applying power 155 atune fault 170 aux fdbk noise fault 169 aux feedback AQB 169 aux feedback loss 169 auxiliary encoder error 168 feedback pinouts 64 specifications 79 auxiliary feedback encoders 81 axis module axis properties 151, 153 catalog number 20 configuring 136 connector designators 59 mounting 54 remove from power rail 182 replacing on power rail 183 series change 13 status indicators 172 wiring requirements 98 axis unstable 175

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

B backplane comm 170 bandwidth 160 Kop 240 base node address example with double-wide modules 140 example with IDM system 141 example with two ControlLogix chassis 139 example with two power rails 138 base node address, sercos 136 baud rate 137 bayonet connector 107 block diagrams converter 215 inverter 214 shunt module 216 blown fuse 167 bonding EMI (electromagnetic interference) 34 examples 35 high-frequency energy 36 subpanels 36 braided strap 95 brake relay 71 building your own cables 84 bus overcurrent 170 overvoltage 168 regulator 148 status indicator 156, 172 undervoltage 168

C cables building your own cables 84 categories 45 CE requirements 22 fiber-optic cable length 130 noise zones 37 routing 26 shield clamp 116 shield, EMC 109, 110, 111 CAN init 170 capacitance values 229 catalog number axis module 20 integrated axis module 20 IPIM module 20 shunt module 20 slot-filler module 20 CB1, CB2, CB3 155 CE compliance 22 changing parameters DriveExplorer 162 HIM 163 circuit breaker LIM 155 selection 28

281

Page 282

Index clamp 116 comm status indicator 156, 172 common bus (refer to DC common bus) compatibility IDM system 21 network 21 compliant mechanical loads 246 configuration 238 configuring AM 136 axis properties 151 baud rate, IAM 137 delay times 153 drive modules 146 feedback only axis 148 IAM 136 optical power level 137 configuring sercos base node address 136 IDM system 135 sercos module 142, 144 connecting Ethernet cables 134 external shunt resistor 127 feedback 117 I/O 117 IPIM module 128 motor shield clamp 116 panel-mounted breakout kit 123 premolded feedback cables 122 resistive brake module 129 sercos cables 130 connector designators axis module 59 integrated axis module 59 connector locations axis module 59 integrated axis module 58 contactor enable relay 70 control power input specifications 77 ControlFLASH firmware upgrade 217 software kit 218 troubleshooting 224 verify upgrade 225, 234 controller properties 142 conventions used in this manual 11 conversion tab 152 converter 215 CPLD FLT 171 cycle time 145

D DAC0 163 DAC1 163 data rate 145 type 147 date/time tab 143

282

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

DC common bus capacitance values 229 common bus flt 171 configuring 148 follower IAM 18, 88 fuse requirements 89 interconnect diagram 193, 194, 195, 196 leader IAM 18, 88 precharge 18, 88, 228 setting the add bus cap parameter 231 total bus capacitance 18 typical installation 18 delay times 153 digital I/O not working correctly 167 digital inputs 67 DIN-style connector 107 dip switches 145 disable drive 177 download program 154 drive compatibility 21 enable fault 169 overcurrent 167 overtemp 169, 170 status indicator 156, 172 tab 151 undervoltage 169 DriveExplorer software 162, 231

E earth ground 95 EMC cable shield 109, 110, 111 motor ground termination 105 EMI (electromagnetic interference) bonding 34 EN ISO 13849 272 enable time synchronization 143 enclosure requirements 26 selection 30 encoder communication fault 168 encoders 81 erratic operation 176 error codes 167 establishing communication 172 EtherNet/IP connecting cables 134 PORT1 and PORT2 connectors 134 external shunt resistor 48 wiring 127

F fault action tab 152

Page 283

Index fault action 178 programmable 178 fault codes IDM system 166 feedback cables and pinouts 117 cables, CE 22 feedback only axis 148 gain (Kof) 240 motor feedback connector 59 power supply 80 tab 152 fiber-optic Rx and Tx connectors 130 signals 68 fiber-optic cables drive-to-drive 132 drive-to-IPIM 133 firmware upgrade 217 verify upgrade 225, 234 follow error 168 follower IAM 18, 88 fuse selection 28

G gains 240 ground fault 168 jumper setting 89 grounded power configuration 85 grounding multiple subpanels 96

H hardware enable input 157, 159 overtravel 167 headers motion allowed jumper 60 HF bonding 34 high-frequency energy 36 resonances 251 HIM 162 hookup fault 170 tab 157 human interface module (HIM) 162

IDM system compatibility 21 configuring sercos 135 firmware upgrade 217 interconnect diagram 212 system overview 17 IDN calculate value 256 change values 253, 266 load observer 237 read value 254 read/write messages 250 write value 257 Ifbk HW fault 169 illegal hall state 168 input connector pinouts, IAM 65 gain (Kou) 240 power source 156 input power wiring 3-phase delta 86 determining input power 85 ground jumper setting 89 grounded power configuration 85 high/low resistance 86 ungrounded power configuration 87 installing drive accessories AC line filters 47 external shunt resistor 48 low-profile connector kits 124 motor brake 50 RBM 50 thermal switch 50 installing your drive 25 bonding examples 35 bonding subpanels 36 cable categories 45 circuit breakers 28 clearance requirements 33 enclosure selection 30 fuse selection 28 HF bonding 34 line filter 27 noise zones 37 system mounting requirements 26 transformer 27 integral bandwidth (Koi) 240

I I/O connections 117 I/O connector 163 pinouts, AM 61 pinouts, IAM 61 specifications 67 IDM fault codes 166 Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

283

Page 284

Index integrated axis module axis properties 151, 153 catalog number 20 configuring 136 connector designators 59 connector locations 58 interconnect diagram 189, 190, 192, 193, 194, 195, 196 mounting 54 removing from power rail 182 replace on power rail 183 series change 13 status indicators 172 wiring BC connector 113 wiring CED connector 103 wiring CPD connector 100 wiring IPD connector 101 wiring MP connector 105 wiring requirements 97, 98 wiring STO connector 104 interconnect diagrams 2094 with 1326AB 205 2094 with F-Series motor 206 2094 with LDAT 209 2094 with LDC-Series 210, 211 2094 with LDL-Series 210, 211 2094 with MPAI 208 2094 with MPAR 208 2094 with MPAS 207 2094 with MPL 198 2094 with MPL motor 199 2094 with MPL/MPM 202 2094 with MPL/MPM/MPF 201 2094 with MPL/MPS 200 2094 with RDD-Series 203 2094 with TL-Series motor 204 IDM system 212 notes 188, 270 power, DC common bus 193, 194, 195, 196 power, IAM with LIM 189, 190 power, IAM without LIM 192 RBM 270 shunt module 2094 197 passive 197 interpreting status indicators 166 inverter 214 IPIM module catalog number 20 compatibility 21 fault 171 mounting 54 removing from power rail 183 wiring 128 IPM fault 167

K Kinetix 6000M system compatibility 21

L leader IAM 18, 88 284

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017 line filter selection 27 line interface module circuit breakers 155 interconnect diagram 189, 190, 192 three-phase power 156 linear motors LDC-Series 210, 211 LDL-Series 210, 211 load inertia ratio 237 load observer acceleration feedback 240 reference 237 actual position feedback 237 auto-tuning 248 bandwidth (Kop) 240 configuration 238 feedback gain (Kof) 240 gains 240 auto-tune 244 compliant mechanical loads 246 high-frequency resonances 251 manual tuning 248 out-of-box 242 rigid mechanical loads 245 IDN read/write messages 250 input gain (Kou) 240 integral bandwidth (Koi) 240 load inertia ratio 237 mechanical load 237 no auto-tuning 248 torque estimate 237 velocity estimate 238 feedback 238 logic power status indicator 155 Logix Designer application 14, 142, 162, 218, 231 low profile connector kits wiring 124

M manual tuning 248 mechanical load 237 memory init 170 module mismatch 170 mounting order 52 properties drive modules 146 sercos module 144 monitor system variables 163 Motion Analyzer 12 motion group properties 150 motion-allowed jumper 60, 104 motor encoder error 168 feedback loss 167 jumps when first enabled 167 overtemp 167

Page 285

Index motors acceleration or deceleration anomalies 175 brake 50 cable length 22, 26 feedback pinouts 62, 119 feedback specifications 79 ground termination 105 interconnect diagram 1326AB 205 F-Series 206 MPL 198, 199 MPL/MPM 202 MPL/MPM/MPF 201 MPL/MPS 200 RDD-Series 203 TL-Series 204 motor and feedback tab 152 MPL connectors bayonet 107 DIN-style 107 overheating 176 power and brake pinouts 66 power wiring 3-phase and brake 110 3-phase only 109 3-phase, brake, thermal switch 111 TL-Series 106 shield clamp wiring 116 testing 157 tuning 157 velocity 175 mounting brackets 51 mounting your drive 54 2094 power rail 52 axis module 54 IAM module 54 IPIM module 54 module mounting order 52 mounting brackets 51 shunt module 54 slot-filler module 54 MPL connectors bayonet 107 DIN-style 107 mtr fdbk noise fault 169

N network compatibility 21 node address 146 noise abnormal 176 feedback 175 reduction 47 zones 37 NV mem init 170

O objects init 170 optical power level 137 overspeed fault 168

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

P panel mounted breakout kit 123 requirements 26 parameters drive IDN 266 peak enhancement 266 system variables 162 drive, IDN 253 load observer 237 peak enhancement 260 peak enhancement definition of terms 75 enable peak enhancement 259 example 261 example calculation 264 inverter overload curve 76 load duty cycle 75 peak current ratings 74 peak overload support 74 software/firmware 74 specifications 74 pinouts auxiliary feedback connector 64 I/O connector IAM/AM 61 input connector, IAM 65 motor and brake connector 66 motor feedback connector 62, 119 safe torque-off connector IAM/AM 60 planning your installation 25 PORT 1 status indicator 156 PORT 2 status indicator 156 power cables, CE 22 cycling 73 dissipation 32 indicator not on 167 phase loss 169 power rail connecting braided strap 95 removing 184 replacing 185 power supply, feedback 80 power up 155 precharge 18, 88, 228 fault 169 timeout flt 171 premolded feedback cables 122 publications, related 12

R RBM 50 related publications 12 relay output 213 remove modules from power rail 182

285

Page 286

Index replace modules on power rail 183 resistive brake module interconnect diagrams 270 wiring 129 rigid mechanical loads 245 routing power and signal wiring 84 RSLinx software 218 RSLogix 5000 software 218, 231

S safe torque-off HW fault 169 motion-allowed jumper 60, 104 pinouts, AM 60 pinouts, IAM 60 wiring 104 safety lock status indicator 156 SCANport comm 170 SCANport/DPI adapter 162, 231 selection AC line filters 27 self sense fault 169 sercos connecting cables 130 connections 68 init 170 module 142 module properties 144 ring fault 169 same addr 169 series change 13 peak enhancement specifications 74 setting the add bus cap parameter 231 seven-segment status indicator 156 shield clamp 116 shunt module 216 bus status indicator 174 catalog number 20 fault 171 interconnect diagram 2094 197 passive 197 mounting 54 removing from power rail 183 shunt fault status indicator 174 temperature status indicator 174 time out 170 troubleshooting 173 wiring requirements 98 shutdown 177 slot-filler module catalog number 20 mounting 54 removing from power rail 183 software DriveExplorer 162, 231 Logix Designer application 14, 142 overtravel 168 286

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017 specifications analog outputs 69 auxiliary feedback encoders 81 brake relay 71 contactor enable relay 70 control power input 77 digital inputs 67 feedback motor and auxiliary 79 power supply 80 peak enhancement 74 power cycling 73 dissipation 32 sercos connections 68 status indicators 156, 166, 172 bus status 172 comm status 172 drive status 172 logic power 155 sercos interface module 156 seven-segment 156 status only 177 stop motion 177 Studio 5000 Logix Designer 14, 142 surge suppression 114 switches base node address 136 baud rate 137 optical power level 137 system components 14 ground 95 mounting requirements 26 system block diagrams converter 215 inverter 214 shunt module 216 system overview DC common bus 18 sercos 19 with LIM 15 without LIM 16

T task init 170 test axes hookup tab 157 thermal switch 50 torque estimate 237 total bus capacitance 18 calculating 228 example 230 training 11 transformer sizing 27 transmit power level 145

Page 287

Index troubleshooting bus status indicator 172 comm status indicator 172 ControlFLASH 224 disable drive 177 drive status indicator 172 error codes 167 fault action 178 general atune fault 170 aux fdbk noise fault 169 aux feedback AQB 169 aux feedback loss 169 auxiliary encoder error 168 backplane comm 170 blown fuse 167 bus overcurrent 170 bus overvoltage 168 bus undervoltage 168 CAN init 170 common bus flt 171 CPLD FLT 171 digital I/O not working correctly 167 drive enable fault 169 drive overcurrent 167 drive overtemp 169, 170 drive undervoltage 169 encoder communication fault 168 follow error 168 ground fault 168 hardware overtravel 167 hookup fault 170 Ifbk HW fault 169 illegal hall state 168 IPIM module flt 171 IPM fault 167 memory init 170 module mismatch 170 motor encoder error 168 motor feedback loss 167 motor jumps when first enabled 167 motor overtemp 167 mtr fdbk noise fault 169 NV mem init 170 objects init 170 overspeed fault 168 power indicator not on 167 power phase loss 169 precharge fault 169 precharge timeout flt 171 safe torque-off HW fault 169 SCANport comm 170 self sense fault 169 sercos init 170 sercos ring fault 169 sercos same addr 169 shunt module fault 171 shunt time out 170 software overtravel 168 task init 170 unknown axis 169 general system anomalies 175 abnormal noise 176 axis unstable 175 erratic operation 176 feedback noise 175 Rockwell Automation Publication 2094-UM001J-EN-P - March 2017 motor acceleration or deceleration 175 motor overheating 176 motor velocity 175 no rotation 176 Logix/drive fault behavior 177 programmable fault action 178 safety precautions 165 shunt module 173 bus status indicator 174 shunt fault status indicator 174 temperature status indicator 174 shutdown 177 status only 177 stop motion 177 tune axes bandwidth 160 tune tab 159 typical installation DC common bus 18 IDM system 17 sercos 19 with LIM 15 without LIM 16

U ungrounded power configuration 87 units tab 152 unknown axis 169 using analog test points 163

V velocity estimate 238 feedback 238

W wiring building your own cables 84 earth ground 95 Ethernet cables 134 external shunt resistor 127 ground jumper setting 89 grounded power configuration 85 I/O connections 117 IAM BC connector 113 CED connector 103 CPD connector 100 IPD connector 101 MP connector 105 STO connector 104 input power type 85 IPIM module 128 low profile connectors 124 motor cable shield clamp 116 motor power 106, 109, 110, 111 requirements 83 IAM 97 IAM/AM 98

287

Page 288

Index shunt module 98 resistive brake module 129 routing power and signal wiring 84 safe torque-off feature 104 sercos fiber optic cables 130 ungrounded power configuration 87 wiring guidelines 99

288

Rockwell Automation Publication 2094-UM001J-EN-P - March 2017

Page 289

This page is a scan with no text; see it in the PDF.

Page 290

.

Rockwell Automation Support Use the following resources to access support information. Technical Support Center

Knowledgebase Articles, How-to Videos, FAQs, Chat, User Forums, and Product Notification Updates.

https://rockwellautomation.custhelp.com/

Local Technical Support Phone Numbers

Locate the phone number for your country.

http://www.rockwellautomation.com/global/support/get-support-now.page

Direct Dial Codes

Find the Direct Dial Code for your product. Use the code to route your call directly to a technical support engineer.

http://www.rockwellautomation.com/global/support/direct-dial.page

Literature Library

Installation Instructions, Manuals, Brochures, and Technical Data.

http://www.rockwellautomation.com/global/literature-library/overview.page

Product Compatibility and Download Center (PCDC)

Get help determining how products interact, check features and capabilities, and find associated firmware. http://www.rockwellautomation.com/global/support/pcdc.page

Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete the How Are We Doing? form at http://literature.rockwellautomation.com/idc/groups/literature/documents/du/ra-du002_-en-e.pdf.

Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page. Allen-Bradley, CompactLogix, ControlFLASH, ControlLogix, DriveExplorer, Guardmaster, HPK-Series, Integrated Architecture, Kinetix, LDC-Series, LDL-Series, Logix5000, MP-Series, RDD-Series, Rockwell Automation, Rockwell Software, RSLinx, RSLogix 5000, SCANport, SoftLogix, Studio 5000 Logix Designer, Studio 5000, and TL-Series are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.

Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400

Publication 2094-UM001J-EN-P - March 2017 Supersedes Publication 2094-UM001I-EN-P - July 2015

Copyright © 2017 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.