The text of a manual · part 26 of 47
Bulletin 2803 VIM Vision Input Module User Manual: 11 - Using the X / Y Float Gages, pages 221 to 226
Pages 221 to 226 of 404, from Bulletin 2803 VIM Vision Input Module User Manual
The original document is the PDF (26 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 2803-VIM2
Page 221
Using the Xl Y Float Gages
Chapter II
Shift Registration
7 1-17
The VIM2 module has a capability called shift registration which allows you to permanently adjust line gages and windows according to a new nominal part position during setup. Use shift registration during setup when you change the nominal workpiece position for your inspection, and you want to readjust the line gage and window positions accordingly. Shift registration. works just like shift compensation, except that, instead of adjusting line gages and windows for a single inspection, shift registration permanently repositions the line gages and windows in your configuration. To use shift registration, you must first configure the VIM2 module for shift compensation, as described earlier in this chapter. In order to make use of shift registration, line gages and windows must be set to Flout status (i.e., shift compensation enabled), as with shift compensation. The positions of any line gages or windows which are set for A~ZOF status (shift compensation disabled), and the positions of truin-thru-thelens windows, are not affected by shift registration. Note: Shift registration is a viable option only when the workpiece position shift is within the feasible limits of the X/Y shift compensation; that is, when the amount of position shift detected does not force the shift any of the vision tools off the inspected image. Or, if “mode 1” (same frame compensation) of brightness compensation is selected, do not allow any vision tools to shift into the top 48 rows of the image. In order to use Shift Registration, and pick the Registration icon.
Your Action Pick the Registration icon on the Setup menu to access the Registration menu.
return to the Setup menu,
Comment The Registration menu.
icon is the second to last icon on the Setup
Setup Menu
IR Registration Menu
Registration Icon
Store Registration /con t
Registration
/con
Page 222
Chapter 7 1-78
Shift Registration (continued)
11
After you have accessed the Registration menu, applying shift registration requires just two steps - picking the Shift Registration icon, then picking the Store Registration icon. Comment
Your Action Pick the Shift Registration icon on the Registration menu.
Using the X / Y f/oat Gages
After you have accessed the Registration menu, picking the Shift Registration icon (the icon color is inverted when picked) causes shift registration to take effect immediately. That is, if the float gages detect a workpiece position which is different from the learned nominal position, the newly detected position becomes the nominal position. Each line gage or window which is configured for float (shift compensation enabled) is then repositioned in the same amount and direction as the workpiece shift. The shift of tool positions is displayed on the monitor. Note: If you decide not to use the new line gage and tool positions, pick the Shift Registration icon again, or simply pick the OK icon to exit the Registration menu without picking the Store Registration icon. The shift registration will be cancelled. If you decide to use the new nominal workpiece position, pick the Store Registration icon.
Pick the Store Registration icon to saue the new parameters.
Picking the Store Registration icon stores the new nominal position and line gage and window positions as part of the current working configuration. Here are some additional points regarding the use of the Store Registration icon: l l l l l
Picking the Store Registration icon will also store the new lighting parameters if brightness registration is enabled (see Chapter 8 for brightness registration information). If brightness registration is already enabled when you are engaging shift registration, shift registration will be implemented based on the brightness compensated image(s). Picking the Store Registration icon before enabling shift (or brightness) registration will have no effect, except that the Store Registration icon will flash. If the amount of shift will move any of the tools offscreen (or, when same frame compensation is selected, into the top 48 rows of the image), picking the Shift Registration icon will have no effect, except that the Shift Registration icon will flash. Acceptance range limits for the registered tools are not affected by shift registration. This means that you will have to return to the Line Gage menu and adjust the acceptance ranges for those line gages which measure position (blob center position, blob edge position, etc.).
Page 223
Chapter
Shift Registration (continued)
11
Using the Xl Y Float Gages 1 l-79
Example Shift Compensation Note: This example refers to threshold image 2 acquired by using the target pattern included with this manual and following the “Quick Start Procedure” in Chapter 6. Suppose, for example, that the black rectangle in threshold image 2 (see diagram below) represents a workpiece in the learned nominal position. Suppose that you place two line gages and a window as shown over the threshold image.
You also use float gages X and Y, and you set the float gage sequence to Y 1/X2, so that any shift detected by the Y gage is applied to the X gage. You enable shift compensation for each line gage and window. Suppose now that you change the nominal workpiece position for your inspection to a position slightly above that of the old position, so that it appears shifted, as shown below, on the monitor:
New workpiece position
-
Original workpiece position
Page 224
Using the Xl Y Float Gages
Chapter 11
I I-20
Shift
Registration (continued)
Your Action Pick the Registr,ation icon on the Setup menu to access the Registration menu.
Example Shift Compensation
(continued)
With the workpiece placed in the new position, use shift registration as follows: Comment The Registration menu.
icon is the second to last icon on the Setup
Setup Menu ~Yy+ll umle+l°K~
I
Regristration icon
Registration
Menu
Registration
Icon
A
Registration Icon v
With the Registration Menu displayed on the monitor, all the enabled tools are displayed on the screen as well - in their original positions:
-
Window2
As you can see, the original positions of the line gages and window are no longer adequate for the most part, and must be adjusted to comply with the position change.
Page 225
Chapter
Shift Registration
11
Using the Xl Y Float Gages
Example
17-27
Shift Compensation fcontinuedl
(continued)
Your Action Pick the Shift Registration icon on the Regist,ration menu.
Shift Registration
Comment After you have accessed the Registration menu, picking the Shift Registration icon (the icon color is inverted when picked) causes shift registration to take effect.
Icon
Line gages and window are repositioned in the same amount and direction as the workpiece shift. The shift of tool positions is displayed on the monitor.
The positions of line gages and window are shifted. Note the position of the Y gage has not changed in this case.
Note the position of the Y gage has not changed in this case, but the X gage is shifted vertically. This is because the float gage sequence selection was set to YI/XZ, so that the vertical change detected by the Y gage is applied to the X gage.
Page 226
Using the Xl Y Float Gages
Chapter II
II-22
Example Shift Compensation
Shift R’egistra tion
Your Action
Comment
Pick the Shift Registration icon again.
Shift Registration Icon
Pick the Shift Registration icon again.
(continued)
If you decide not to use the new line gage and tool positions, pick the Shift Registration icon again, or simply pick the OK icon to exit the Registration menu without picking the Store Registration icon (as described below). The shift registration will be cancelled.
(continued)
Picking the Shift Registration icon a second time cancels the shift registration (the Shift Registration icon color reverts to its original color). All line gages and windows revert to their original positions.
Y You can enable the shift registration the Shift Registration icon again.
again by simply pick
If you decide to use the new nominal workpiece position, pick the Store Registration icon while the Shift Registration is enabled. Pick the Store Registration icon to save the new parameters.
Picking the Store Registration icon stores the new nominal position and line gage and window positions as part of the current working configuration.
’
Store Registration
Icon