Page 61
Chapter
Chapter
Objectives
VIM2 Sys tern Components
5
Connection and Power-up
This chapter provides guidelines for installation and connection of the VIM2 module and peripheral system components, describes power-up indications and checks, and describes the VIM2 LED indicators and swingarm I/O.
The procedures in this chapter relate only to those components that are part of the VIM2 machine vision system, namely: l
VIM2 module, Cat. No. 2803-VIM2.
l
1771 I/O rack: PLC 1771 I/O rack 1771-PSC rack (standalone)
l
Chassis power supply (any of a number of suitable power supplies)
l
External 12.5 VDC power supply (one of several suitable power supplies, depending on line input voltage)
l
Monochrome video monitor: g-inch, 115 VAC, Cat. No. 2801-N9. g-inch, 230 VAC, Cat. No. 2801-N20. 12-inch, 115 VAC, Cat. No. 2801-N6.
l
Light pen, Cat. No. 2801-N7 l
Camera: Cat. No. 2801-YC Cat. No. 2801-YD l
Interconnecting wires and cables
Additional components may be required for some installations. These will be identified where appropriate this chapter.
Connecting the V/M2 System Components in
Before you install your VIM2 system at its factory-floor site, you may find it useful to connect the basic components temporarily on a workbench or tabletop, where you can perform a connection and power-up check. There you can also get acquainted with the VIM2 user interface and the functional features, and review the set-up techniques presented in this manual.
Page 62
Chapter 5-2
Requirements for /nsta//ation of the VIM2 Modde installation Into an Installed 1771 II0 Rack
5
Connection and Power-up
This section discusses requirements for installing the VIM2 module into a 1771 r/O rack, or a standalone rack, such as the Allen-Bradley Cat.. No. 1771-PSC.
Installation of a VIM2 module into an installed 1771 I/O rack is dependent upon two requirements: availability of slot space and availability of sufficient power. Availability of Space The VIM.2 module requires a module group (two adjacent vacant slots) in which to be mounted. If your existing 1771 I/O rack does not have two adjacent empty slots, you have two options: 1) acquire a larger rack; 2) acquire an additional rack. See your local Allen-Bradley representative for details.
Availability of Sufficient Power If your existing I/O rack has the required space, next determine whether the existing power supply has enough current to satisfy the VIM2 module. The VIM2 module requires 3 amps of current (maximum) in order to operate. To determine if your power source has sufficient current, subtract the total amount of current consumed by each individual component in the rack (see individual unit documentation), other than the VIM2 module, from the total amount of current output from your power source (see power supply documentation:). If the resultant number is greater than or equal to 3 amps, sufficient current is available. Total Current Output
- Total Current Consumed
= Available
Current
If your existing 1771 I/O rack does not have enough power, you have two options: 1) employ a larger power supply; 2) acquire an additional rack with power supply. See your local Allen-Bradley representative for details.
If your I/O rack meets power and space requirements, can install your VIM2 module (see “VIM2 Module Installation” in this section).
you
Page 63
Chapter
Connection and Power-up
5
5-3
Requirement5 for installation Into a 1771 Standalone II0 Rack
A standalone I/O rack (such as catalog number 1771-PSC) has four slots, two for the VIM2 module and two for an inrack power supply (catalog number 1771-P3). Since the standalone unit is self-contained, there will always be enough space and current. For additional rack installation information refer to the documentation accompanying your standalone rack.
/IO Rack Installation
For information on I/O rack installation, see documents 1771-4.5, “Mounting Instructions for 1771 I/O Chassis and Power Supply,” and 1770-4.1 “Grounding and Wiring Guidelines.” Read these documents before installing rack.
A t l
CAUTION: Ground loops can seriously impair the performance of the VIM2 module. Ensure that proper grounding procedures are followed. Refer to Cat. No. 1770-4.1, “Grounding and Wiring Guidelines” for correct grounding procedures.
Power Supply Installation
Many PLC system power supplies are available for use by the VIM2 module. For information on the installation of specific power supplies, refer to the documentation accompanying that power supply as well as Cat. No. 17704.1, “Grounding and Wiring Guidelines.”
VIM2 Module Installation
This section provides guidelines module.
A t l for installing the VIM2
WARNING: Remove system power before attempting installation of VIM2 module. Failure to do so may result in electrical shock.
Use of Keying Bands Keying bands are shipped with each I/O chassis. Use of keying bands is recommended. Use of keying bands helps to prevent installation of a module in the wrong slot. Keying bands can be installed and replaced with needle-nose pliers.
Page 64
Chapter 5-4
VIM2 Moduk lnstalla tion
5
Connection and Power-up
Install keying bands before installing the VIM2 module, as follows:
(continued)
1. Each VIM2 module plugs into two addressing slots on the backplane (two per slot) - determine which two slots the VIM2 module will occupy. 2. Install two keying bands on the top right socket of the two slots used by the VIM2 module. The socket has guide numbers along the right side to aid in the positioning of the keying bands. Install keying bands between numbers 16 - 18 and 26 - 28 for the VIM2 module (see Figure 5.1).
Figure 5.1 Installation of Kevinq Bands
2 4 6 8 $!E ._.........: ::m
Install Keying Bands in these two locations
:.:.:.:.;; ;zz;; :.:.:.:.:.:.: .................. II::::$$::::: I 1.
10 12 14 16 18 20 22 24 26 28
Top Right Backplane Socket
30 32 34 36
Page 65
Chapter
VIM2 Module Installation (continued)
5
Connection and Power-up 5-5
Setting the I/O Chassis Configuration Plug Many 1771 I/O chassis contain a “configuration plug.“This is a stake-pin jumper located on the chassis backplane near the PLC controller slot. Set the configuration plug to the Y (left) position - covering the middle and left prongs - or to the N (right) position - covering the middle and right prongs -depending on the presence of a PLC and power supplies, as follows (refer to Figure 5.2): Set to Y when either - You are using an in-rack power supply module, or - You are using the VIM2 module(s) in the chassis with no PLC processor present. Set to N when - You are using both an external power supply and a PLC controller. Figure 5.2 C&figuration
PIIug Settings on 1771 I/O chassis backalane
L
Y
USING POWER SUPPLY MODULE IN THIS CHASSIS? -
Page 66
Chapter 5-6
VIM2 Module Installation (continued)
5
Connection and Power- up
VIM2 Module Installation To install the VIM2 module into the 1771 chassis (see Figure 5.3): 1. Lift open the module locking latch at the top of the chassis slot. 2. Insert the module into the slots, sliding the module along the plastic guides on the top and bottom of each slot. Note: Do not force the module into its backplane socket. Apply firm and even pressure to seat it into its sockets. 3. After the VIM2 module is seated in place, close the module locking latch. At this point the VI1M2 module has been installed. Next you will connect the video camera, video monitor, camera power supply (to the swingarm), and swingarm.
Figure 5.3 installation of the VIM2 Module
Page 67
Chapter
Camera Component hstalla tion
5
Connection and Power-up 5-7
This section describes installation procedures for the video camera, cable, lens, and extension tube. Lenses You have the option of using any of several lenses depending upon your application needs. See Chapter 4 for information regarding lens characteristics and specifications; also refer to the Product Data sheet, Publication No. 2801-2.6. See Figure 5.4 for an illustration of camera and lens configurations. All lenses include an installation and maintenance instruction booklet. Consult your local AllenBradley representative for additional information. Camera Extension Tubes The optional camera extension tubes (see Figure 5.4) are used to alter the image focal length. This allows you to use the lenses at shorter distances. See Chapter 4 for lens extension information. Installation instructions are provided with each unit.
Page 68
Chapter 5-8
Connection and Power-up
5
Camera Component Installation (con hued) Figure 5.4 Camera Confiaurations
TVDid
C-MOUNT LENS Cat. No. 2801-K
Camera
Extension Tube 2801 -Nl (Optional)
PHOTOGRAPHIC LENS
Cat. No. 2801-K
C-MOUNT Lens 2801-NLl (25 mm) 2801 -NL2 (I 2.5 mm) 2801 -NL5 (12 - 75 mm zoom) 2801 -NL6 (50 mm)
C-MOUNT To PHOTOGRAPHIC Len5 Adapter 2801 -N2
Camera
Extension Tube 2801-Nl (Optional)
Lens ’ 2801-NL3 (105 mm) 2801-NL4 (55 mm) 2801-NL8 (35 - 70 mm zoom) 2801 -NL9 (60 mm)
Page 69
Connection and Power-up
Chapter 5
Camera Component lnstalla tion (continued)
5-9
Connecting the Camera to the VIM2 Module
Connect the camera to the VIM2 module through the 12-pin camera connector cable. Connector cables are offered in various lengths; refer to the Product Data sheet, publication no. 2801-2.4, for connector cable information. To connect the camera cable: 1. Plug the male end of the cable into the CAMERA input jack on the face of the VIM2 module (see Figure 5.6). 2. Plug the other end of the cable into the 12-pin output jack on the back of the camera (see Figure 5.5) which is labeled VISION SYSTEM. If resistance is encountered realign the pins and try again. 3. To remove the cable from its connection, slide the collar of the connector back towards you while pulling the cable out of its jack. Figure 5.5 Camera I/O Locations
Camera Rear View r
DC In/Ext. Svnc. Insert Cam&a Cable Connector i
Video Out i No Connections
Note: In order to operate, the video camera requires an external 12.5 VDC power source, which must be connected to the VW2 module swingarm. See the section covering connection of the camera power supply under “Swingarm Installation,” this chapter.