Spec sheet · Allen-Bradley
PHOTOSWITCH Series 9000 On/Off and Timing Photoelectric Sensors Installation Instructions
Spec sheet8 pagesPDF 670 KB
Installation instructions and specifications for Allen-Bradley PHOTOSWITCH Series 9000 on/off and timing photoelectric sensors.
What this file really is
The old site listed this file as a spec sheet for the Allen-Bradley 42DRU-5200 and 42GRF-9000-QD. The file is named as a 42DRU-5200 spec sheet, but it is the installation instructions for the PHOTOSWITCH Series 9000 sensors and does not mention the 42DRU-5200.
Names · 1 model
The models it names
Filed with · 1 model
Also filed with these models on the old site
Summary
What is in it
Installation instructions for the PHOTOSWITCH Series 9000 family of on/off and timing photoelectric sensors, covering polarized retroreflective, retroreflective, transmitted beam, ClearSight, diffuse and fiber optic versions. It gives specifications and catalog numbers by supply voltage and output type, wiring diagrams for cable and quick disconnect models, typical response curves, dimensions, mounting accessories and temperature notes, then explains fiber installation, alignment, light/dark operate selection, teach mode and timer settings.
Its parts
- Specifications
- Wiring Diagrams
- Typical Response Curves
- Dimensions
- Accessories
- Operational Notes
- Configuring the Sensor
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
Allen-Bradley installation instructions (August 2014) for the PHOTOSWITCH Series 9000 on/off and timing photoelectric sensors, catalog numbers beginning 42G. They give specifications, wiring diagrams, response curves, dimensions, accessories and the steps to align and configure the sensors, including the fiber optic, teach and timing versions. The sheet covers only the Series 9000 and does not describe the 42DRU-5200.
- Device
- PHOTOSWITCH Series 9000 photoelectric sensor, on/off and timing versions, in three connection types p. 1, 6
- Operating temperature
- -34°C to +70°C (-29°F to +158°F), except solid state and relay output models p. 1
- Humidity
- 5% to 95% relative humidity p. 1
- Enclosure rating
- The sheet states NEMA 3, 4X, 6P, 12, 13, IP67 p. 1
- Housing and lens
- Valox housing, acrylic lens p. 1
- Sensitivity
- Single-turn potentiometer; factory default is maximum sensitivity p. 1, 6
- Indicators
- Yellow: power; green: output; red: margin/SCP p. 1, 6
- Protections
- False pulse on all versions; short circuit and overload on solid state output versions; reverse polarity on DC versions p. 1
- Supply versions
- 10-40V DC NPN and PNP; 10-55V DC/20-40V AC SPDT EM relay; 70-264V DC/60-264V AC SPDT EM relay; 70-264V AC/DC solid state isolated N.O.; relay load 2A/132V AC, 1A/264V AC, 1A/150V DC p. 1
- DC output wiring
- White wire NPN, black wire PNP; load on the black or white wire gives sourcing or sinking respectively p. 2
- Mounting hardware
- Hardware kit #129-130 supplied: plastic mounting nut, lock washer, two M5 x 0.8 x 53 screws and nuts p. 5
- Brackets
- Swivel/tilt assembly #60-2439 (#60-2681 for ClearSight 9000); vertical height brackets #60-2721 (4 in), #60-2722 (6 in), #60-2723 (8 in), #60-2724 (10 in) p. 5
- Cordsets
- 889 Series cordsets and patchcords for quick disconnect models p. 6
- Timing range
- Timing models: short (0 to 1.5 sec) or long (0 to 15 sec) by DIP switch, set with two 15-turn knobs; timers nonretriggerable p. 7
What this sheet walks you through
- Wiring cable and quick disconnect models p. 2, 6
- Installing fiber optic cables on 42GxF versions p. 6
- Choosing light-operate or dark-operate mode and setting sensitivity p. 6
- Aligning transmitted beam, retroreflective and diffuse versions p. 6, 7
- Teaching the 42GSP-9000 its light and dark conditions p. 7
- Setting ON, OFF and one-shot delays on timing models p. 7, 8
- Mounting the sensor and choosing brackets p. 4, 5
- Setting the switch on 42GRL transmitted beam sources p. 7
Good to know
- Turning the sensitivity knob past its minimum or maximum stop damages it. p. 6
- The cover must be closed tightly after setup to keep the stated environmental ratings. p. 6
- Solid state (42Gxx-9xx3) and relay (42Gxx-9xx2) models lose temperature range at higher supply voltage: 220V AC limits ambient to +55°C. p. 5
- A mounting subject to vibration or shifting may cause intermittent operation. p. 5
Questions this sheet answers
What is the operating temperature of an Allen-Bradley Series 9000 photoelectric sensor?
-34°C to +70°C (-29°F to +158°F). Solid state and relay output models have a lower limit at higher supply voltages, for example +55°C at 220V AC. p. 1, 5
How do I install the fiber optic cable on a Series 9000 sensor?
Set the locking lever to UNLOCKED, insert the cable until the internal clip engages, then rotate the lever to LOCK. p. 6
What does the red LED mean on a Series 9000 photoelectric sensor?
On means the margin is above 2.5 times the signal needed; flashing means output SCP is active. p. 6
Which cordsets fit Series 9000 quick disconnect sensors?
The sheet recommends the 889 Series of cordsets and patchcords. p. 6
What delay range do the 42GT timing sensors have?
Short (0 to 1.5 sec) or long (0 to 15 sec), chosen by DIP switch and set with two 15-turn knobs. p. 7
Contents
Chapters and sections
Each line opens the PDF at its page.
The whole text · 1 part
Read the sheet here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file


