Page 116

Chapter 5 Using the RS–232 Ports

Set/Read Configurable Statistics (cont’d)

The block signature is 2 bytes long. The number of samples is a 2 byte integer. The maximum and minimum values are each 4 bytes. The format of the data depends upon the operation (e.g. pixel count is an integer and linear gaging is a 16.16 fixed point value). Refer to page C–24 for data formats. The average and standard deviation are also 4 bytes each but are always 16.16 fixed point values. Therefore, each tool statistic consists of 18 bytes with the exception of reference windows which contain 18 bytes for each feature or a total of 54 bytes. The statistics block is transmitted as two hexadecimal characters for each byte. The total number of bytes including the block signature should not exceed 128 bytes. The statistics block is read once for every number of specified samples. This means that if you read the statistics block five times with a sample number of 50, 250 triggers will have to be processed before the five reads are completed. The following shows the format of the returned data: Statistics Block Returned Data Format*

*Data is transmitted without spaces, spacing added for clarity.

Trigger Operation Command

Use the trigger operation command to initiate an inspection by a toolset. Use the following commands: 09

04

Triggers an inspection using toolset 1. 09

05

Triggers an inspection using toolset 2. This function can only be executed once per command. If the BCC is not valid, the CVIM module will respond with a DLE NAK and the command will not be executed. If the BCC is valid, the CVIM module will respond with a DLE ACK. Then the CVIM module will validate the command structure. If the command is 5–46

Page 117

Chapter 5 Using the RS-232 Ports valid, the CVIM module will execute the command and return the data. If the command structure is invalid, the CVIM module will not execute the command or respond. Note: When using this command you should make sure that the CVIM module is configured for a “hosted trigger source”.

Unlock Command

Use the unlock command to enable the user interface (monitor and keyboard) so that a user can access the SETUP. This command has the following structure:

If the BCC is not valid, the CVIM module will respond with a DLE NAK and the command will not be executed. If the BCC is valid, the CVIM module will respond with a DLE ACK. Then the CVIM module will validate the command structure. If the command is valid, the CVIM module will execute the command. If the command structure is invalid, the CVIM module will not execute the command or respond.

Write Configuration Blocks

Use the write command to write data to configuration blocks. Note: You can also write to the monitor display to select what is displayed. Refer to Select Image Displayed. This command has the following structure:

Where the flags specify the configuration blocks being written to. There are 135 configuration blocks. Refer to the following diagram.

5–47

Page 118

Chapter 5 Using the RS–232 Ports

Write Configuration Blocks (cont’d)

8

32

56

80

7

31

55

79

104 103

128 127

6

30

54

78

Write Configuration Block Command Bytes 3–29

Byte 3

Byte 4

Byte 5

Bits 7 – 0

Bits 7 – 0

Bits 7 – 0

5

4

3

2

1

16

15

13

12

11

10

9

24

23

22

21

20

19

18

17

43

42

41

67

66

65

91

90

89

116 115 114

113

Byte 6

Byte 7

Byte 8

Bits 7 – 0

Bits 7 – 0

Bits 7 – 0

29

28

27

26

25

40

39

38

37

36

35

34

33

48

47

46

45

44

Byte 9

Byte 10

Byte 11

Bits 7 – 0

Bits 7 – 0

Bits 7 – 0

53

52

51

50

49

64

63

62

61

60

59

58

57

72

71

70

69

68

Byte 12

Byte 13

Byte 14

Bits 7 – 0

Bits 7 – 0

Bits 7 – 0

77

76

75

74

73

88

87

86

85

84

83

82

81

96

95

94

93

92

Byte 15

Byte 16

Byte 17

Bits 7 – 0

Bits 7 – 0

Bits 7 – 0

102 101

100

99

98

97

112 111

110 109

108 107 106 105

Byte 18

Byte 19

Bits 7 – 0

Bits 7 – 0

126 125

124 123 122 121

136 135

Set individual bits to select blocks 1 through 136.

5–48

14

134 133

132 131 130 129

120 119

118 117

Page 119

Chapter 5 Using the RS-232 Ports

This function can only be executed once per command. Each configuration block is sent in a separate data packet (Header/Data/Trailer). Refer to Appendix D for a description of the configuration blocks. You cannot use this command when the CVIM module is in the setup mode. After writing to the CVIM module, the CVIM module will validate all of the configuration blocks (refer to Chapter 4 for a description of memory validation). Example:

This example writes the data into configuration block #3. If the BCC is not valid, the CVIM module will respond with a DLE NAK and the command will not be executed. If the BCC is valid, the CVIM module will respond with a DLE ACK. Then the CVIM module will validate the command structure. If the command is valid, the CVIM module will execute the command. If the command structure is invalid, the CVIM module will not execute the command or respond. Note: We recommend that you check the discrete bit ‘‘Configuration Fault’’ after loading a configuration. Refer to Appendix B. Since no data is returned with this command, the load operation may fail and you could detect this by checking the fault bit. You can check this bit by using the read discrete bit results command for toolset #1.

5–49

Page 120

Chapter 5 Using the RS–232 Ports

Command Summary

After you have become familiar with the DF1 commands, you can use the following command summary as a quick reference guide. Table 5.B DF1 Command Summary Command Deactivate Forces Echo Data

01 00 nn Data 14

Disable Outputs

15

Force Outputs

02 06 Flags Flags Data

Load Configuration From Credit Card to RAM*

Field Descriptions

0C

Enable Outputs

Load Configuration From EEPROM to RAM nn = times repeated Data = Hexadecimal string

Flags indicate outputs Data = 00 (on) or 01 (off)

03 00

03 01 Data

Lock

04

Unlock

0A

Data = 01 (area 1) 02 (area 2) DDD 15(area 15) 16(area 16)

Read Output Condition

05 00 nn 06 Flags Flags nn = times repeated Flags indicate outputs

Read Configuration

06 07 Flags

Flags indicate blocks

Read Discrete Bit Results

07 00 nn 04 07 00 nn 05

First discrete bit results Second discrete bit results nn = times repeated

*

5–50

Command Structure

The number of configurations that can be stored on a RAM card depends upon the card size (512K card can hold 16 configurations).

Page 121

Chapter 5 Using the RS-232 Ports

Table 5.B DF1 Command Summary (Cont’d) Command

Command Structure

Field Descriptions n= x= y=

07 00 n x y z z=

Read Results Block

Save to EEPROM from RAM times repeated 04 (Toolset 1) 05 (Toolset 5) 16(Gages) 17 (Window) 18 (Reference Line) 19 (Reference Window 1A (Light Probe) Window, Gage, Reference Line, or Reference Window No.

07 00 n 10 Data

Toolset 1 Results n = times repeated Data = Block Number(s) 1, 2, 3 or 4

07 00 n 15 Data

Toolset 2 Results n = times repeated Data = Block Number(s) 1, 2, 3 or 4

07 00 n 04

Toolset 1 discrete bit results n = times repeated

07 00 n 05

Toolset 2 discrete bit results n = times repeated

07 00 n 08

Read Status

08 00

Save to RAM Card from RAM

08 01 Data

Data = 01 (area 1) 02 (area 2) DDD 15(area 15) 16(area 16)

Set ConfigurabIe Results

OD Flags

Flags indicate specific tools

Set ConfigurabIe Statistics

16 00 n Flags

Flags indicate specific tools n = times repeated

Read ConfigurabIe Statistics

17 00 n

Trigger Inspection Write Configuration Block

09 0B 07 Flags Data n = times repeated Trigger Flags indicate blocks

5–51

Page 122

Chapter 5 Using the RS–232 Ports

Command Summary (cont‘d)

Table 5.B DF1 Command Summary (Cont’d) Command

Write Display

Command Structure

0B 02 Data

OB 13 Data

OB 14 Data

5–52

Field Descriptions Data = 0B–Image Only Toolset 1 0C–Failed Tools Toolset 1 0D–All Tools Toolset 1 0E–l/O Page Toolset 1 0F–Results Page Toolset 1 10–Stats 1 Page Toolset 1 11–Stats 2 Page Toolset 1 12–Page Up Same Display Toolset 1 13–Page Down Same Display 15–Image Only Toolset 2 16–Failed Tools 17–All Tools Toolset 2 18–l/O Page Toolset 2 19–Results Page Toolset 2 1A–Stats 1 Page Toolset 2 1B–Stats 2 Page Toolset 2 1C–Page Up Same Display Toolset 2 1D–Page Down Same Display Toolset 2 Data = 0B–Go On Reject Toolset 1 0C–Freeze On First Reject Toolset 1 0D–Freeze On All Reject Toolset 1 0E–Freeze On Next Inspection Toolset 1 0F–Halt On Reject Toolset 1 15–Go On Reject Toolset 2 16–Freeze On First Reject Toolset 2 17–Freeze On All Reject Toolset 2 18–Freeze On Next Inspection Toolset 2 19–Halt On Reject Toolset 2 Data = 0B–Resume Toolset 1 0C–Reset Statistics Toolset 1 0D–Reset Counters Toolset 1 12–Page Up Toolset 1 13–Page Down Toolset 1 15–Resume Toolset 2 16–Reset Statistics Toolset 2 17–Reset Counters Toolset 2 18–Page Up Toolset 2 19–Page Down Toolset 2

Page 123

Chapter 5 Using the RS-232 Ports

DF1 Programming Example

The following is a sample DF1 program written in C. The program configures the host computer’s serial port for 9600 Baud communications. The program then displays a menu which prompts the user to select one of the following operations: 0. Echo the word “HELLO” to test the communications port. 1. Trigger the CVIM module to perform an inspection using toolset #1. 2. Read the discrete bit results for toolset 1. 3. Read the results block #1 for toolset 1. 4. Read gage #1 statistics for toolset 1. 5. Trigger the CVIM module to perform an inspection using toolset #2. 6. Read the discrete bit results for toolset 2. 7. Read the results block #1 for toolset 2. 8. Read gage #1 statistics for toolset 2. 9. Read configuration block n. 10.. Write configuration block n. 11.. Change display to results page, toolset 1. 12. Page up, toolset 1 display. 13. Page down, toolset 1 display. 14.. Change display to results page, toolset 2. 15. Page up, toolset 2 display. 16. Page down, toolset 2 display. The program demonstrates a simple implementation of the DF1 protocol. Your actual application program may require some enhancements such as increased error checking or time–out conventions. The sample program begins on the next page.

5–53

Page 124

Chapter 5 Using the RS–232 Ports

DF1 Programming Example (cont’d) /* CVIM RS–232 Communication example program using DF1 protocol */ /* Copyright Allen–Bradley 12-5-89 jrm, aes */ This sample program was compiled using Microsoft C Version 5.1 */ #include <stdio.h> #include <stdlib.h> #include <bios.h> #define STX 0x02 #define ETX 0x03 #define ENQ 0x05 #define DLE 0x10 #define ACK 0x06 #define NAK 0x15

/* Start of Text character */ /* End of Text character */ /* Enquire */ /* Data Link Escape (Control char) */ /* Positive acknowledgement */ /* Negative acknowledgement */

#define COMMFLAGS 0x8E00

/* defines bits to check for comm error */

#define MAX BUFFER

128 /* define storage for configuration data */ unsigned char config [135] [MAX BUFFER] configlen [135] template [256] [MAX BUFFER] templen [256[ unsigned char last_response = 0; void main() { int x, op_num, portnum, err, replen, reslen, numblocks; unsigned char reply[200], results[MAX BUFFER]; /* Get Serial port number from user */ printf (”Enter port number (1 for COM1 or 2 for COM2):”); scanf (”%d”, &portnum)); /* make portnum either 0 or 1 */ portnum = (portnum – 1) & 0x01; /* Open comm channel to at 9600 baud */ _bios_serialcom (_COM_INIT, portnum–1, _COM_CHR8 | _COM_STOP1 | _COM_NOPARITY | _COM_9600);

5–54