Manual · Allen-Bradley
Bulletin 5370 CVIM Configurable Vision Input Module Communications Manual
Manual202 pagesPDF 723 KB
Communications manual for the Allen-Bradley Bulletin 5370 CVIM Configurable Vision Input Module: local I/O, remote I/O, RS-232 and backplane.
Names · 1 model
The models it names
Filed with · 1 model
Also filed with these models on the old site
Summary
What is in it
Allen-Bradley communications manual for the Bulletin 5370 Configurable Vision Input Module (CVIM), catalog 5370-CVIM Series A or B. It explains how a host device reads inspection results and reads or writes configuration data over local I/O, the remote I/O link (node adapter) with PLC-2, PLC-3 and PLC-5 controllers, the RS-232 ports using ASCII and DF1 commands, and the Pyramid Integrator backplane. Appendices describe the discrete bits, results blocks and configuration blocks.
Its parts
- Using this Manual
- Introduction
- Using Local I/O
- Using the Remote I/O Link (Node Adapter)
- Using the RS-232 Ports
- Using the Pyramid Integrator Backplane
From the manual
Key facts from this manual
Each line names its page in the PDF.
This is the Allen-Bradley communications manual for the Bulletin 5370 CVIM Configurable Vision Input Module (5370-CVIM Series A or B, firmware revision C03 or later). It explains how a PLC, computer or terminal reads inspection results and loads configurations through the remote I/O link, the RS-232 ports, local I/O or the Pyramid Integrator backplane, with ASCII and DF1 commands and sample programs.
- Covered hardware
- 5370-CVIM Series A or B with firmware revision C03 or later p. 9
- Communication ports
- Remote I/O (node adapter), RS-232 ports A and B, Pyramid Integrator backplane, local I/O board p. 13, 17
- Remote I/O link
- Up to 10,000 ft at 57.6K baud, 5,000 ft at 115.2K, 2,500 ft at 230.4K (230.4K only between PLC-5/250 controllers in other racks) p. 38
- Remote I/O cable
- Twin-axial cable 1770-CD to the RIO port p. 38
- Remote I/O image
- Appears as a full I/O rack (128 input and 128 output bits) plus a block transfer module in group 0, slot 0 p. 43
- Remote I/O hosts
- PLC-2, PLC-3 and PLC-5 controllers, or computers with the 6008-SI IBM bus scanner p. 15
- RS-232 ports
- Ports A and B on the 2801-N21 or 2801-N27 I/O Interface Box, which plugs into the MODULE I/O port p. 72
- Serial settings
- 300 to 19.2K baud; 8 data bits, 1 stop bit, no parity; ASCII or DF1 protocol p. 74
- Local I/O
- 1771-JMB I/O board in a 2801-N21 or 2801-N27 interface box, linked by 2801-NC17 cable; one trigger input and up to 14 outputs p. 13, 15
- Series A I/O connector
- Pins 1 and 2 trigger inputs; pins 3 to 16 output lines 1 to 14; pins 23 to 26 RS-232 A (TXD, RTS, RXD, CTS) p. 31
- Backplane
- Pyramid Integrator shared memory of 1024 words, shared with a PLC-5/250, MicroVAX or Resource Manager p. 15, 134
- Memory
- RAM, EEPROM, RAM card or external host memory; a 512K RAM card holds 16 configurations p. 16, 91
- Discrete bits
- 128 bits read by the host (faults, busy, pass/fail/warning) and 128 bits it sets (trigger, toolset, display) p. 16
- Software
- DATAMYTE and Dataliner devices need USER-PAK Software 5370-UPK p. 15
What this manual walks you through
- Planning output line assignments and connections for local I/O p. 20
- RS-232 connector pinouts on the 2801-N27 and 2801-N21 interface boxes p. 29, 30
- Connecting the CVIM to a PLC-5 or scanner over remote I/O p. 38, 39
- Setting baud rate, host and protocol for the RS-232 ports p. 74
- Cabling a PC to the RS-232 port p. 73
- ASCII command reference (trigger, read results, load and save configurations) p. 91, 92
- Setting up communication over the Pyramid Integrator backplane p. 135
Good to know
- With the 2801-N27 interface box and Series A CVIM hardware, only RS-232 port A is active. p. 72
- Only one port can be the host at a time; only the host can control the module, trigger inspections and load configurations. p. 134
- If the CVIM is the last node on a remote I/O network, the line must be terminated. p. 43
- Over the backplane, results are posted right after processing; on the other ports only at the end of the inspection program. p. 135
Questions this manual answers
What baud rates does the CVIM RS-232 port support?
From 300 to 19.2K baud, with a fixed format of 8 data bits, 1 stop bit and no parity. p. 74
What cable connects a CVIM to a remote I/O network?
Twin-axial cable 1770-CD, from the RIO port to the next device on the network. p. 38
How many outputs does the CVIM local I/O board have?
Sixteen discrete lines: fourteen outputs, one trigger input, and one unused line. p. 13
How many CVIM configurations fit on a RAM card?
It depends on the card size; a 512K card holds 16 configurations. p. 91
Which PLCs can communicate with the CVIM?
PLC-2, PLC-3 and PLC-5 controllers over the remote I/O port, and a PLC-5/250 over the Pyramid Integrator backplane. p. 15
Contents
Chapters and sections
Each line opens the PDF at its page.
- 5370-ND002, Bulletin 5370 CVIM Configurable Vision Input Module Communications Manual1
- Important User Information2
- 1 - Using this Manual9
- 2 - Introduction13
- Chapter Objectives13
- How is Data Stored in the CVIM Module?13
- How Does the Host Device Read Configuration/Results Information?13
- Remote I/O (Node Adapter)15
- RS–232 Ports15
- Local I/O15
- Pyramid Integrator Backplane15
- What Types of Information can be Communicated?16
- Discrete Bit Information16
- Results Blocks17
- Configuration Blocks17
- Communications Cables17
- Memory Addressing17
- Host Designation19
- Multiple Hosts19
- 3 - Using Local I/O20
- Chapter Objectives20
- Equipment Connections20
- Planning Output Line Assignments21
- Using the Output Line Planning Sheet21
- Using Output Signal Timing Data25
- Planning Output Line Connections29
- Connections to RS–232 Ports (2801-N27 Interface Box)29
- Connections to RS–232 Port (2801-N21 Interface Box)30
- CVIM Module I/O Interface Box Connections31
- Connections to 1771-JMB Interface34
- 4 - Using the Remote I/O Link38
117 more lines, from page 38 on
- Chapter Objectives38
- Remote I/O Communications38
- What Functions can be Performed over the Remote I/O Network?43
- Obtaining Inspection Result Information44
- CVIM Module Configuration Instructions44
- Accessing Discrete Bit Information45
- Example Program for Accessing/Setting Discrete Bit Data48
- Accessing Results and Configuration Information51
- Transferring Results Blocks52
- Configuring Results Block 4 and Statistics Block Formats53
- Converting Results Data54
- Transferring Configuration Blocks56
- Transferring Template Blocks57
- Example Program for Accessing Results Data58
- Example Program For Accessing Configuration Data62
- Example 6008–SI Program66
- 5 - Using the RS-232 Ports71
- Chapter Objectives71
- RS–232 Communications71
- ASCII and DF1 Protocols71
- Equipment Connections72
- What Functions can be performed over the RS-232 Interfaces?73
- CVIM Module Configuration Instructions74
- ASCII Protocol75
- Overview75
- ASCII Character Set75
- Command Structure76
- XON/XOFF Flow Control77
- Deactivate Forces77
- Echoing Data77
- Enable/Disable Outputs78
- Forcing Local I/O78
- Loading Configurations79
- Lock Command79
- Read Output Status80
- Read Configuration Blocks80
- Read Inspection Results82
- Save Configuration84
- Select Image Displayed85
- Set Configurable Results86
- Set/Read Configurable Statistics87
- Trigger Operation89
- Unlock Command89
- Write Configuration (W) Write Configuration (WC)89
- Command Summary91
- Explanation of ASCII Programming Example93
- ASCII Programming Example95
- DF1 Protocol96
- What is DF1?96
- DF1 Character Set96
- Command Structure97
- ACK/NAK, BCC Characters98
- Block Check Character98
- Deactivate Forces100
- Echoing Data100
- Enable/Disable Outputs101
- Forcing Local I/O101
- Loading Configurations102
- Lock Command103
- Read Output Status103
- Read Configuration Block Command104
- Read Results Command108
- Save Command111
- Select Image Displayed111
- Set Configurable Results114
- Set/Read Configurable Statistics115
- Trigger Operation Command116
- Unlock Command117
- Write Configuration Blocks117
- Command Summary120
- DF1 Programming Example123
- 6 - Using the Pyramid Integrator Backplane134
- Chapter Objectives134
- What Information can be Accessed?134
- Host Designation134
- What Functions can be Performed Over the Backplane?135
- CVIM Module Configuration Instructions135
- Obtaining Inspection Result Information Using a PLC-5/250136
- Manipulating Configuration Data Using a PLC-5/250137
- Sample PLC–5/250 Program139
- Obtaining Inspection Result Information Using a MicroVAX Information Processor141
- A - Results/Configuration Data Overview142
- B - Discrete IIO Results Bits (Host Input & Output Bits)146
- C - Numerical Results Data164
- D - Configuration Data180
- Configuration Block Overview180
- Configuration Block #1181
- Configuration Blocks 2 & 3183
- Configuration Blocks 4–6184
- Configuration Blocks 7 – 9185
- Configuration Blocks 10 – 41186
- Configuration Blocks 42 – 65188
- Configuration Blocks 66 – 68189
- Configuration Blocks 69–71190
- Configuration Blocks 72–103191
- Configuration Blocks 104–127193
- Configuration Blocks 128–135194
- Template Blocks 136–194
- E - ASCII Conversion Table195
- Glossary196
- Index199
- Back Cover202
The whole text · 25 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 81-8
- 1 - Using this Manual9-12
- 2 - Introduction13-19
- 3 - Using Local I/O, pages 20 to 2820-28
- 3 - Using Local I/O, pages 29 to 3729-37
- 4 - Using the Remote I/O Link, pages 38 to 4638-46
- 4 - Using the Remote I/O Link, pages 47 to 5547-55
- 4 - Using the Remote I/O Link, pages 56 to 6456-64
- 4 - Using the Remote I/O Link, pages 65 to 7065-70
- 5 - Using the RS-232 Ports, pages 71 to 7971-79
- 5 - Using the RS-232 Ports, pages 80 to 8880-88
- 5 - Using the RS-232 Ports, pages 89 to 9789-97
- 5 - Using the RS-232 Ports, pages 98 to 10698-106
- 5 - Using the RS-232 Ports, pages 107 to 115107-115
- 5 - Using the RS-232 Ports, pages 116 to 124116-124
- 5 - Using the RS-232 Ports, pages 125 to 133125-133
- 6 - Using the Pyramid Integrator Backplane134-141
- A - Results/Configuration Data Overview142-145
- B - Discrete IIO Results Bits (Host Input & Output Bits), pages 146 to 154146-154
- B - Discrete IIO Results Bits (Host Input & Output Bits), pages 155 to 163155-163
- C - Numerical Results Data, pages 164 to 171164-171
- C - Numerical Results Data, pages 172 to 179172-179
- D - Configuration Data180-194
- Pages 195 to 198195-198
- Pages 199 to 202199-202
The file