Page 155
Appendix B Discrete Bit Results
Discrete Bit Outputs (cont’d)
Note: When using the backplane, don’t write directly to word 2. Write to word 1023. The CVIM will copy the data from word 1023 to word 2. Note: When communicating with a device through the Pyramid Integrator backplane, CVIM module results are posted in shared memory immediately after processing. When communicating with a device through the other ports, results are only available at the end of the inspection program. Table B.3 Discrete Bit Outputs
Word #
PI Backplane
Bit #
RS–232 and Remote I/O
D E C I M A L
O C T A L
PI
PLC
Definition
2
0
0–7
0–7
Not Used
2
0
8
10
Lock Request
Usage
Notes
0 = No Change 1 = Lock
Do not set bits 8 and 9 at the same time. If you set both bits, the CVIM will be unlocked. You must reset this bit to 0, then back to 1 to repeat a lock request.
2
0
9
11
Unlock Request
0 = No Change 1 = Unlock
You must reset this bit to 0, then back to 1 to repeat an unlock request.
2
0
10
12
Host Trigger Toolset 1
0 = No Trigger 1 = Trigger
You must reset this bit to 0, then back to 1 to repeat a trigger request.
2
0
11
13
Host Trigger Toolset 2
0 = No Trigger 1 = Trigger
You must reset this bit to 0, then back to 1 to repeat a trigger request.
2
0
12
14
Light Pen Request
0 = No Request 1 = Request
Bit 12 commands are specified in: Output words 1 and 6 (Remote I/O) Output words 3 and 8 (Backplane) You must reset bit to 0, then back to 1 to repeat a light pen request.
B–10
Page 156
Appendix B Discrete Bit Results
Table B.3 Discrete Bit Outputs Word #
PI Backplane
2
Bit #
RS–232 and Remote I/O
0
D E C I M A L
O C T A L
PI
PLC
13
15
Definition
Usage
I/O Request
0 = No Request 1 = Request
Notes
Bit 13 commands are specified in: Output words 2, 4, and 5 (Remote I/O) Output words 4, 6, and 7 (Backplane) You must reset bit to 0, then back to 1 to repeat an I/O request.
2
0
14
16
Configuration Move
0 = No Request 1 = Request
Bit 14 commands are specified in: Output word 2 (Remote I/O) Output word 4 (Backplane) You must reset bit to 0, then back to 1 to repeat a configuration move request.
2
0
15
17
Not Used
B–11
Page 157
Appendix B Discrete Bit Results
Discrete Bit Outputs (cont’d) Table B.3 Discrete Bit Outputs Word#
PI Backplane
3
Bit#
RS–232 and Remote I/O
1
D E C I M A L
O C T A L
PI
PLC
0–7
0–7
Definition
Usage
Runtime Display Control
00000000 = No Change 00000001 = Display Image Only 00000010 = Display Failed Tool 00000100 = Display All Tools 00001000 = Display I/O Page 00010000 = Display Results Page 00100000 = Display Statistics 1 Page 01000000 = Display Statistic 2 Page
B–12
Notes
Page 158
Appendix B Discrete Bit Results
Table B.3 Discrete Bit Outputs Word#
PI Backplane
3
Bit#
RS–232 and Remote I/O
1
D E C I M A L
O C T A L
PI
PLC
8 – 15
10 – 17
Definition
Usage
Freeze on Reject Control
00000000 = No Change
Notes
00000001 = Go On Reject 00000010 = Freeze First Reject 00000100 = Freeze All Rejects 00001000 = Freeze Next Image 00010000 = Halt On Reject 4
2
N/A
0–3
Toolset Flag Select
Not Applicable to Backplane
0000 = Not Valid
Bits 0 – 3 control which set of toolset results are assigned to discrete input words 1 through 7.
0001 = Toolset 1 0010 = Toolset 2
4
2
4–5
4–5
Discrete I/O Control
00 = No Change
Bits 4 through 7 refer to the local I/O module (Catalog Number 1771–JMB).
01 = Disable Outputs 10 = Enable Outputs 4
2
6–7
6–7
Forced I/O Control
00 = No Change 01 = Disable Forces 10 = Enable Forces
Bits 6 and 7 act upon the bitmap you set up in words: 4 and 5 (Remote I/O) 6 and 7 (Backplane)
B–13
Page 159
Appendix B Discrete Bit Results
Discrete Bit Outputs (cont’d) Table B.3 Discrete Bit Outputs Word#
PI Backplane
4
Bit#
RS–232 and Remote I/O
2
D E C I M A L
O C T A L
PI
PLC
8 – 11
10 – 13
Definition
Usage
Configuration Move Control
0000 = No Request
Notes
0001 = EEPROM to RAM 0010 = RAM to EEPROM 0100 = RAM Card to RAM 1000 = RAM to RAM Card 4
2
12 – 15
14 – 17
RAM Card Index
0000 = RAM Card Configuration 1 1111 = RAM Card Configuration 16
B–14
Bits 12 through 15 are numeric fields which specify RAM card locations 1 through 16.
Page 160
Appendix B Discrete Bit Results
Table B.3 Discrete Bit Outputs Word #
PI Backplane
5
Bit #
RS–232 and Remote I/O
3
D E C I M A L
O C T A L
PI
PLC
N/A
0–2
Definition
Usage
Block Transfer Type
000 = Invalid Request
Reference only. Not used for Backplane.
001 = Results Block 010 = Configuration Block 100 = Template Block 101 = Statistics Block – See Notes
Notes
This word only applies to Remote I/O interface. To send programmable block transfer to the CVIM, set bits 0, 1, and 2 to equal 111 and then send a block transfer write. No other bits (last block, toolset, or block number) need to be sent. After sending a configuration block or template block to the CVIM, you should check the condition of the configuration fault bit (Word 0, Discrete Bit Inputs) To send programmable statistics , set bits 0, 1, and 2 to equal 101 and then send a block transfer write to the CVIM. No other bits (last block , toolset, or block number) need to be sent.
111 = Programmable Block Transfer – See Notes 5
3
N/A
3
Last Block Flag
Reference only. Not used for Backplane. 5
Reference only. Not used for Backplane.
Bit 3 only applies to block transfer writes.
1 = Last Block 3
N/A
4–7
Toolset Request
0000 = No Toolset 0001 = Toolset 1 0010 = Toolset 2
Bits 4 through 7 only apply to results block.
3
N/A
10 – 17
Block Transfer Block Number
0 = Invalid Number See Notes
Results block numbers may be from 1 to 4. Configuration block numbers may be from 1 to 136. Template block numbers may be from 1 to 255 (variable).
Reference only. Not used for Backplane. 5
0 = Not Last Block
B–15
Page 161
Appendix B Discrete Bit Results
Discrete Bit Outputs (cont’d) Table B.3 Discrete Bit Outputs Word#
PI Backplane
B–16
Bit#
RS–232 and Remote I/O
D E C I M A L
O C T A L
PI
PLC
Definition
Usage
Notes
6
4
0
0
Local I/O Output 1 Force ON
0 = No Force 1 = Force On
Refers to Catalog Number 1771–JMB Local I/O Board.
6
4
1
1
Local I/O Output 2 Force ON
0 = No Force 1 = Force On
Refers to Catalog Number 1771–JMB Local I/O Board.
6
4
2
2
Local I/O Output 3 Force ON
0 = No Force 1 = Force On
Refers to Catalog Number 1771–JMB Local I/O Board.
6
4
3
3
Local I/O Output 4 Force ON
0 = No Force 1 = Force On
Refers to Catalog Number 1771–JMB Local I/O Board.
6
4
4
4
Local I/O Output 5 Force ON
0 = No Force 1 = Force On
Refers to Catalog Number 1771–JMB Local I/O Board.
6
4
5
5
Local I/O Output 6 Force ON
0 = No Force 1 = Force On
Refers to Catalog Number 1771–JMB Local I/O Board.
6
4
6
6
Local I/O Output 7 Force ON
0 = No Force 1 = Force On
Refers to Catalog Number 1771–JMB Local I/O Board.
6
4
7
7
Local I/O Output 8 Force ON
0 = No Force 1 = Force On
Refers to Catalog Number 1771–JMB Local I/O Board.
6
4
8
10
Local I/O Output 9 Force ON
0 = No Force 1 = Force On
Refers to Catalog Number 1771–JMB Local I/O Board.
6
4
9
11
Local I/O Output 10 Force ON
0 = No Force 1 = Force On
Refers to Catalog Number 1771–JMB Local I/O Board.
6
4
10
12
Local I/O Output 11 Force ON
0 = No Force 1 = Force On
Refers to Catalog Number 1771–JMB Local I/O Board.
6
4
11
13
Local I/O Output 12 Force ON
0 = No Force 1 = Force On
Refers to Catalog Number 1771–JMB Local I/O Board.
6
4
12
14
Local I/O Output 13 Force ON
0 = No Force 1 = Force On
Refers to Catalog Number 1771–JMB Local I/O Board.
6
4
13
15
Local I/O Output 14 Force ON
0 = No Force 1 = Force On
Refers to Catalog Number 1771–JMB Local I/O Board.
6
4
14 – 15
16 – 17
Not Used
Page 162
Appendix B Discrete Bit Results
Table B.3 Discrete Bit Outputs Word#
PI Backplane
Bit#
RS–232 and Remote I/O
D E C I M A L
O C T A L
PI
PLC
Definition
Usage
Notes
7
5
0
0
Local I/O Output 1 Force OFF
0 = No Force 1 = Force Off
Refers to Catalog Number 1771–JMB Local I/O Board.
7
5
1
1
Local I/O Output 2 Force OFF
0 = No Force 1 = Force Off
Refers to Catalog Number 1771–JMB Local I/O Board.
7
5
2
2
Local I/O Output 3 Force OFF
0 = No Force 1 = Force Off
Refers to Catalog Number 1771–JMB Local I/O Board.
7
5
3
3
Local I/O Output 4 Force OFF
0 = No Force 1 = Force Off
Refers to Catalog Number 1771–JMB Local I/O Board.
7
5
4
4
Local I/O Output 5 Force OFF
0 = No Force 1 = Force Off
Refers to Catalog Number 1771–JMB Local I/O Board.
7
5
5
5
Local I/O Output 6 Force OFF
0 = No Force 1 = Force Off
Refers to Catalog Number 1771–JMB Local I/O Board.
7
5
6
6
Local I/O Output 7 Force OFF
0 = No Force 1 = Force Off
Refers to Catalog Number 1771–JMB Local I/O Board.
7
5
7
7
Local I/O Output 8 Force OFF
0 = No Force 1 = Force Off
Refers to Catalog Number 1771–JMB Local I/O Board.
7
5
8
10
Local I/O Output 9 Force OFF
0 = No Force 1 = Force Off
Refers to Catalog Number 1771–JMB Local I/O Board.
7
5
9
11
Local I/O Output 10 Force OFF
0 = No Force 1 = Force Off
Refers to Catalog Number 1771–JMB Local I/O Board.
7
5
10
12
Local I/O Output 11 Force OFF
0 = No Force 1 = Force Off
Refers to Catalog Number 1771–JMB Local I/O Board.
7
5
11
13
Local I/O Output 12 Force OFF
0 = No Force 1 = Force Off
Refers to Catalog Number 1771–JMB Local I/O Board.
7
5
12
14
Local I/O Output 13 Force OFF
0 = No Force 1 = Force Off
Refers to Catalog Number 1771–JMB Local I/O Board.
7
5
13
15
Local I/O Output 14 Force OFF
0 = No Force 1 = Force Off
Refers to Catalog Number 1771–JMB Local I/O Board.
7
5
14 – 15
16 – 17
Not Used
B–17
Page 163
Appendix B Discrete Bit Results
Discrete Bit Outputs (cont’d) Table B.3 Discrete Bit Outputs Word#
PI Backplane
B–18
Bit#
RS–232 and Remote I/O
D E C I M A L
O C T A L
PI
PLC
Definition
Usage
Notes
8
6
0–1
0–1
Toolset Display Control
8
6
2
2
Not Used
8
6
3
3
Resume Control
0 = No Change 1 = Resume
Use in conjunction with light pen request: Word 0 bit 12 (Remote) Word 2 bit 12 (Backplane)
8
6
4–5
4–5
Page Control
00 = No Change 01 = Page Up 10 = Page Down
Use in conjunction with light pen request: Word 0 bit 12 (Remote) Word 2 bit 12 (Backplane)
8
6
6
6
Reset Statistics
0 = No Change 1 = Reset
Use in conjunction with light pen request: Word 0 bit 12 (Remote) Word 2 bit 12 (Backplane)
8
6
7
7
Reset Counters
0 = No Change 1 = Reset
Use in conjunction with light pen request: Word 0 bit 12 (Remote) Word 2 bit 12 (Backplane)
8
6
8 – 15
10 – 17
Not Used
00 = No Change 01 = Display Toolset 1 10 = Display Toolset 2